Перевод: с английского на русский

с русского на английский

not-and+circuit

  • 61 auto-cutout

    1. автоматический выключатель

     

    автоматический выключатель
    Механический коммутационный аппарат
    1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
    (МЭС 441-14-20)
    [ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]

    автоматический выключатель
    -
    [IEV number 442-05-01]

    EN

    circuit breaker
    a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

    circuit breaker

    A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
    NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
    Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
    Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
    Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
    Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
    [National Electrical Cod]

    FR

    disjoncteur
    appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

      1)  Должно быть контактный коммутационный аппарат
    [Интент] 
    КЛАССИФИКАЦИЯ

      0067 Автоматические выключатели ABB   0068 Модульные автоматические выключатели
    1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
    Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
    Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).

    [Интент]
    Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
    [
    Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Электромагнитный расцепитель;
    5 - Сердечник
    6 - Катушка
    7 - Контактные зажимы автоматического выключателя

    Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
    На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
    Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).

    Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем. 

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Тепловой расцепитель
    5 - Биметаллическая пластина
    6 - Нагревательный элемент
    7 - Контактные зажимы автоматического выключателя

    Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
    [Интент]

    Недопустимые, нерекомендуемые

    Тематики

    Классификация

    >>>

    Обобщающие термины

    Действия

    EN

    DE

    FR

    Смотри также

    Англо-русский словарь нормативно-технической терминологии > auto-cutout

  • 62 automatic cutout

    1. автоматический выключатель

     

    автоматический выключатель
    Механический коммутационный аппарат
    1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
    (МЭС 441-14-20)
    [ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]

    автоматический выключатель
    -
    [IEV number 442-05-01]

    EN

    circuit breaker
    a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

    circuit breaker

    A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
    NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
    Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
    Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
    Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
    Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
    [National Electrical Cod]

    FR

    disjoncteur
    appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

      1)  Должно быть контактный коммутационный аппарат
    [Интент] 
    КЛАССИФИКАЦИЯ

      0067 Автоматические выключатели ABB   0068 Модульные автоматические выключатели
    1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
    Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
    Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).

    [Интент]
    Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
    [
    Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Электромагнитный расцепитель;
    5 - Сердечник
    6 - Катушка
    7 - Контактные зажимы автоматического выключателя

    Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
    На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
    Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).

    Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем. 

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Тепловой расцепитель
    5 - Биметаллическая пластина
    6 - Нагревательный элемент
    7 - Контактные зажимы автоматического выключателя

    Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
    [Интент]

    Недопустимые, нерекомендуемые

    Тематики

    Классификация

    >>>

    Обобщающие термины

    Действия

    EN

    DE

    FR

    Смотри также

    Англо-русский словарь нормативно-технической терминологии > automatic cutout

  • 63 gear

    1. распределительный щит
    2. распределительное устройство
    3. оборудование
    4. инструменты
    5. входить в сцепление
    6. аппаратура

     

    аппаратура
    -
    [Интент]

    FR


    Тематики

    • аппарат, изделие, устройство...

    EN

     

    входить в сцепление
    приводить в движение механизм


    [ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]

    Тематики

    Синонимы

    EN

     

    оборудование
    Совокупность связанных между собой частей или устройств, из которых по крайней мере одно движется, а также элементы привода, управления и энергетические узлы, которые предназначены для определенного применения, в частности для обработки, производства, перемещения или упаковки материала. К термину «оборудование» относят также машину и совокупность машин, которые так устроены и управляемы, что они функционируют как единое целое для достижения одной и той же цели.
    [ГОСТ ЕН 1070-2003]

    оборудование
    -

    [IEV number 151-11-25 ]

    оборудование
    Оснащение, материалы, приспособления, устройства, механизмы, приборы, инструменты и другие принадлежности, используемые в качестве частей электрической установки или в соединении с ней.
    [ ГОСТ Р МЭК 60204-1-2007]

    EN

    equipment
    single apparatus or set of devices or apparatuses, or the set of main devices of an installation, or all devices necessary to perform a specific task
    NOTE – Examples of equipment are a power transformer, the equipment of a substation, measuring equipment.
    [IEV number 151-11-25 ]

    equipment
    material, fittings, devices, components, appliances, fixtures, apparatus, and the like used as part of, or in connection with, the electrical equipment of machines
    [IEC 60204-1-2006]

    FR

    équipement, m
    matériel, m
    appareil unique ou ensemble de dispositifs ou appareils, ou ensemble des dispositifs principaux d'une installation, ou ensemble des dispositifs nécessaires à l'accomplissement d'une tâche particulière
    NOTE – Des exemples d’équipement ou de matériel sont un transformateur de puissance, l’équipement d’une sous-station, un équipement de mesure.
    [IEV number 151-11-25]

    Тематики

    EN

    DE

    FR

     

    распределительное устройство
    Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [РД 34.20.185-94]

    распределительное устройство

    Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
    Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
    [ ГОСТ 24291-90]
    [ ГОСТ Р 53685-2009]

    электрическое распределительное устройство
    распределительное устройство
    Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
    Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
    [ОСТ 45.55-99]

    распределительное устройство
    Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [ПОТ Р М-016-2001]
    [РД 153-34.0-03.150-00]

    устройство распределительное
    Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    EN

    switching substation
    a substation which includes switchgear and usually busbars, but no power transformers
    [IEV number 605-01-02]

    FR

    poste de sectionnement
    poste de coupure

    poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
    [IEV number 605-01-02]

    В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
    На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]


    КЛАССИФИКАЦИЯ

    В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:

    • по назначению:
      • генерирующие,
      • преобразовательно-распределительные,
      • потребительские.

        Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;

     Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласно ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:

    для электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
    для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.

    Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.

    Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.

    Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.

    Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.

    • по способу управления ПС могут быть:
      • только с телесигнализацией,
      • телеуправляемыми с телесигнализацией,
      • с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).


    Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.

    В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.

    В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
     



    Several different classifications of switchgear can be made:

    A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.

    Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.

    [Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
    [ http://en.wikipedia.org/wiki/High_voltage_switchgear]

    Тематики

    Синонимы

    EN

    DE

    FR

     

    распределительный щит
    Комплектное устройство, содержащее различную коммутационную аппаратуру, соединенное с одной или более отходящими электрическими цепями, питающееся от одной или более входящих цепей, вместе с зажимами для присоединения нейтральных и защитных проводников.
    [ ГОСТ Р МЭК 60050-826-2009]

    щит распределительный
    Электротехническое устройство, объединяющее коммутационную, регулирующую и защитную аппаратуру, а также контрольно-измерительные и сигнальные приборы
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    распределительный щит

    [А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]

    EN

    distribution board
    assembly containing different types of switchgear and controlgear associated with one or more outgoing electric circuits fed from one or more incoming electric circuits, together with terminals for the neutral and protective conductors.
    [IEV number 826-16-08]

    FR

    tableau de répartition, m
    ensemble comportant différents types d'appareillage associés à un ou plusieurs circuits électriques de départ alimentés par un ou plusieurs circuits électriques d'arrivée, ainsi que des bornes pour les conducteurs neutre et de protection.
    [IEV number 826-16-08]

    Параллельные тексты EN-RU

    Distribution switchboards, including the Main LV Switchboard (MLVS), are critical to the dependability of an electrical installation. They must comply with well-defined standards governing the design and construction of LV switchgear assemblies

    A distribution switchboard is the point at which an incoming-power supply divides into separate circuits, each of which is controlled and protected by the fuses or switchgear of the switchboard. A distribution switchboard is divided into a number of functional units, each comprising all the electrical and mechanical elements that contribute to the fulfilment of a given function. It represents a key link in the dependability chain.

    Consequently, the type of distribution switchboard must be perfectly adapted to its application. Its design and construction must comply with applicable standards and working practises.

    [Schneider Electric]

    Распределительные щиты, включая главный распределительный щит низкого напряжения (ГРЩ), играют решающую роль в обеспечении надежности электроустановки. Они должны отвечать требованиям соответствующих стандартов, определяющих конструкцию и порядок изготовления НКУ распределения электроэнергии.

    В распределительном щите выполняется прием электроэнергии и ее распределение по отдельным цепям, каждая из которых контролируется и защищается плавкими предохранителями или автоматическими выключателями.
    Распределительный щит состоит из функциональных блоков, включающих в себя все электрические и механические элементы, необходимые для выполнения требуемой функции. Распределительный щит представляет собой ключевое звено в цепи обеспечения надежности.

    Тип распределительного щита должен соответствовать области применения. Конструкция и изготовление распределительного щита должны удовлетворять требованиям применимых стандартов и учитывать накопленную практику применения.

    [Перевод Интент]

     

    5654

    Рис. Schneider Electric

    With Prisma Plus G you can be sure to build 100% Schneider Electric switchboards that are safe, optimised:

    > All components (switchgear, distribution blocks, prefabricated connections, etc.) are perfectly rated and coordinated to work together;

    > All switchboard configurations, even the most demanding ones, have been tested.

    You can prove that your switchboard meets the current standards, at any time.

    You can be sure to build a reliable electrical installation and give your customers full satisfaction in terms of dependability and safety for people and the installation.

    Prisma Plus G with its discreet design, blends harmoniously into all tertiary and industrial buildings, including in entrance halls and passageways.

    With Prisma Plus G you can build just the right switchboard for your customer, sized precisely to fit costs and needs.

    With this complete, prefabricated and tested system, it's easy to upgrade your installation and still maintain the performance levels.

    > The wall-mounted and floor-standing enclosures combine easily with switchboards already in service.

    > Devices can be replaced or added at any time.

    [Schneider Electric]

    С помощью оболочек Prisma Plus G можно создавать безопасные распределительные щиты, на 100 % состоящие из изделий Schneider Electric:

    > все изделия (коммутационная аппаратура, распределительные блоки, готовые заводские соединения и т. д.) полностью совместимы механически и электрически;

    > все варианты компоновки распределительных щитов, в том числе для наиболее ответственных применений, прошли испытания.

    В любое время вы можете доказать, что ваши распределительные щиты полностью соответствуют требованиям действующих стандартов.

    Вы можете быть полностью уверены в том, что создаете надежные электроустановки, удовлетворяющие всем требованиям безопасности для людей и оборудования

    Благодаря строгому дизайну, распределительные щиты Prisma Plus G гармонично сочетаются с интерьером любого общественного или промышленного здания. Они хорошо смотрятся и в вестибюле, и в коридоре.

    Применяя оболочки Prisma Plus G можно создавать распределительные щиты, точно соответствующие требованиям заказчика как с точки зрения технических характеристик, так и стоимости.

    С помощью данной испытанной системы, содержащей все необходимые компоненты заводского изготовления можно легко модернизировать существующую электроустановку и поддерживать её уровни производительности.

    > Навесные и напольные оболочки можно легко присоединить к уже эксплуатируемым распределительным щитам.

    > Аппаратуру можно заменять или добавлять в любое время.

    [Перевод Интент]

     

    The switchboard, central to the electrical installation.

    Both the point of arrival of energy and a device for distribution to the site applications, the LV switchboard is the intelligence of the system, central to the electrical installation.

    [Schneider Electric]

    Распределительный щит – «сердце» электроустановки.

    Низковольтное комплектное устройство распределения является «сердцем» электроустановки, поскольку именно оно принимает электроэнергию из сети и распределяет её по территориально распределенным нагрузкам.

    [Перевод Интент]

    Тематики

    EN

    DE

    FR

    Англо-русский словарь нормативно-технической терминологии > gear

  • 64 contact

    1. устанавливать контакт
    2. силовой прием
    3. приводить в контакт
    4. контактный элемент
    5. контактный (вторичный) случай
    6. контактный
    7. контакт

     

    контакт (1)
    -
    [IEV number 151-12-15 ]

    контакт (контактного коммутационного аппарата)
    Токопроводящие части, предназначенные для установления непрерывности цепи при их соприкосновении и в результате их движения относительно друг друга в процессе оперирования размыкающие или замыкающие цепь либо, если это шарнирные или скользящие контакты, поддерживающие непрерывность цепи.
    МЭК 60050(441-15-05).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    контакт
    Токоведущая часть аппарата, которая во время операции размыкает и замыкает цепь, или в случае скользящих или шарнирных контактов сохраняет непрерывность цепи
    [РД 34.45-51.300-97]

    EN

    contact (1)
    set of conductive elements for establishing electric circuit continuity when they touch each other and which, due to their relative motion during an operation, open or close an electric circuit or, in the case of some hinged or sliding elements, maintain circuit continuity
    NOTE – See also the concept "electric contact" in 151-12-03.
    [IEV number 151-12-15 ]

    contact (of a mechanical switching device)
    conductive parts designed to establish circuit continuity when they touch and which, due to their relative motion during an operation, open or close a circuit or, in the case of hinged or sliding contacts, maintain circuit continuity
    [IEV number 441-15-05]

    FR

    contact (1), m
    ensemble d'éléments conducteurs destinés à établir la continuité d'un circuit électrique lorsqu'ils se touchent et qui, par leur mouvement relatif pendant la manœuvre, ouvrent ou ferment un circuit électrique ou, dans le cas de certains éléments pivotants ou glissants, maintiennent la continuité du circuit
    NOTE – Voir aussi le concept "contact électrique" en 151-12-03.
    [IEV number 151-12-15 ]

    contact (d'un appareil de connexion)
    pièces conductrices destinées à établir la continuité d'un circuit lorsqu'elles se touchent et qui, par leur mouvement relatif pendant la manoeuvre, ouvrent et ferment un circuit ou, dans le cas de contacts pivotants ou glissants, maintiennent la continuité du circuit
    [IEV number 441-15-05]

    2

     

    контакт (2)
    -
    [IEV number 151-12-16]

    EN

    contact (2)
    conductive element intended to make an electric contact
    [IEV number 151-12-16]

    FR

    contact (2), m
    élément conducteur destiné à établir un contact électrique
    [IEV number 151-12-16]

    Тематики

    • контакт
    • электротехника, основные понятия

    Действия

    EN

    DE

    FR

     

    контактный (вторичный) случай
    контактное лицо
    контакт инфекционного заболевания

    Лицо, контактировавшее с источником инфекции. См. также Acquaintance network (группа лиц, контактировавших с источником возбудителя инфекции).
    [Англо-русский глоссарий основных терминов по вакцинологии и иммунизации. Всемирная организация здравоохранения, 2009 г.]

    Тематики

    • вакцинология, иммунизация

    Синонимы

    EN

     

    контактный элемент
    Деталь аппарата для цепей управления (неподвижная или подвижная, проводящая или изолированная) для замыкания или размыкания единственного пути прохождения тока в цепи.
    Примечания:
    1. Контактный элемент и механизм передачи усилия могут быть объединены в единый узел, но чаще один или несколько элементов могут быть скомбинированы с одним или несколькими механизмами передачи усилия, и их конструкция может быть разной.
    2. В состав контактных элементов не входят катушки и магниты управления.
    [ ГОСТ 50030.5.1-2005]


    контактный элемент
    контакт (2)
    -
    [IEV number 151-12-16]

    EN

    contact member
    contact (2)
    conductive element intended to make an electric contact
    [IEV number 151-12-16]

    FR

    élément de contact, m
    contact (2), m
    élément conducteur destiné à établir un contact électrique
    [IEV number 151-12-16]

    0247
    [IEV number 444-04-06]

    EN

    1. Contact set - контактная группа
    2. Ouput circuit - выходная цепь
      contact circuit - цепь контакта
      contact - контакт
    3. Contact member - контактный элемент
    4. Contact point - рабочая поверхность контакт-детали, контакт-деталь

    FR

    1. Jeu de contacts - контактная группа
    2. Circuit de sortie - выходная цепь
      circuit de contact - цепь контакта
      contact - контакт
    3. Element de contact - контактный элемент
    4. Piece de contact - рабочая поверхность контакт-детали, контакт-деталь

    [Перевод Интент]

    Примечания
    1 - Контактный элемент такой конструкции как на рисунке слева называют также конактная пружина.
    2 - По существу, контактный элемент, это одна из частей контакта,
    т. е. в замыкающем, размыкающем и переключающем контактах любой подвижный и неподвижный контакт является контактным элементом.

    [Интент]

     

     

     

     

    Тематики

    Синонимы

    EN

    DE

    FR

     

    приводить в контакт

    [А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]

    Тематики

    EN

     

    силовой прием
    Тактика, которую используют хоккеисты для того, чтобы вывести противника из игры или отобрать у него шайбу. Использование силового приема разрешается только, если противник, к которому этот прием применяется, владеет шайбой или был последним, кто ее касался. Хоккеист, применяющий силовой прием, может использовать только бедра или плечи, и может совершать удар только в область выше колена и ниже шеи противника. В женском хоккее с шайбой силовой прием считается нарушением, и, как правило, не допускается в любительских и детских лигах.
    [Департамент лингвистических услуг Оргкомитета «Сочи 2014». Глоссарий терминов]

    EN

    bodycheck(ing)
    contact
    Tactic used by a hockey player to physically remove an opponent from the puck or the play. A bodycheck is legal only if the player being checked has the puck or was the last person to touch it. The bodychecker may only use the hips or shoulder, and must make the hit above the opponent's knees and below the neck. In women's ice hockey, any body checking is a penalty and is also usually not allowed in amateur leagues and leagues with young children.
    [Департамент лингвистических услуг Оргкомитета «Сочи 2014». Глоссарий терминов]

    Тематики

    EN

     

    устанавливать контакт

    [А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]

    контактировать
    -
    [Интент]

    Штыри калибра должны быть изготовлены из проводящего материала.
    Соответствующий калибр должен вставляться во входное отверстие каждого гнезда приборной розетки соединителя с усилием, не превышающим 5 Н.
    Когда этот калибр полностью вставлен, самая длинная вилка («калибр - контакт») должна устанавливать контакт, а самая короткая вилка («калибр - неконтакт») не должна устанавливать контакт.

    [ ГОСТ Р 51325. 1-99 ( МЭК 60320-1-94)]

    ... которые в нормальных условиях не контактируют с электролитом
    [ ГОСТ 15596-82]

    необходимо учитывать повышенную температуру воздуха внутри электрической машины или аппарата, повышенную температуру оболочки, с которой контактирует изоляция провода.
    [ ГОСТ 15963-79]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    Англо-русский словарь нормативно-технической терминологии > contact

  • 65 PSC-assembly

    1. силовое комплектное устройство распределения и управления
    2. НКУ распределения и управления

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

     

    силовое комплектное устройство распределения и управления
    СНКУ

    Низковольтное комплектное устройство распределения и управления, применяемое для распределения и управления энергией всех типов нагрузок промышленного, коммерческого и аналогичного назначений, не предназначенное для управления не квалифицированным персоналом.
    [ ГОСТ Р МЭК 61439.2-2012]

    EN

    power switchgear and controlgear assembly
    PSC-assembly

    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    NOTE It is not excluded for a PSC-assembly to be located in an area accessible to ordinary persons.
    [IEC 61439-2, ed. 2.0 (2011-08)]

    FR

    ensemble d'appareillage de puissance
    ensemble EAP
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    NOTE Il n’est pas exclu d’implanter un ensemble EAP dans une zone accessible aux personnes ordinaires.
    [IEC 61439-2, ed. 2.0 (2011-08)]

    Тематики

    • НКУ (шкафы, пульты,...)

    Синонимы

    EN

    FR

    Англо-русский словарь нормативно-технической терминологии > PSC-assembly

  • 66 switchgear

    1. распределительное устройство
    2. коммутационное устройство
    3. коммутационная аппаратура
    4. аппаратура распределения

     

    аппаратура распределения
    Общий термин для коммутационных аппаратов и их комбинаций с относящимися к ним устройствами управления, измерения, защиты и регулирования, а также для узлов, в которых такие аппараты и устройства соединяются с соответствующими фидерами, комплектующим оборудованием, оболочками и опорными конструкциями, предназначенных, в принципе, для использования в системах производства, передачи, распределения и преобразования электрической энергии.
    МЭК 60050(441-11-02).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    EN

    switchgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures, intended in principle for use in connection with generation, transmission, distribution and conversion of electric energy
    [IEV number 441-11-02]

    FR

    appareillage de connexion
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les supports correspondants, destinés en principe à être utilisés dans le domaine de la production, du transport, de la distribution et de la transformation de l'énergie électrique
    [IEV number 441-11-02]

     

    Тематики

    • аппарат, изделие, устройство...

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte für Energieverteilung

    FR

     

    коммутационная аппаратура
    коммутационное оборудование


    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

     

    коммутационное устройство
    Устройство, предназначенное для обеспечения или прерывания подачи электрического тока в электрические цепи.
    Примечание - Коммутационное устройство может выполнять одну или обе эти функции.
    [ГОСТ ЕН 1070-2003]

    коммутационное устройство
    -
    [IEV number 442-01-46]

    EN

    switching device
    a device designed to make or break the current in one or more electric circuits
    Source: 441-14-01 MOD
    [IEV number 442-01-46]

    switchgear

    any of several devices used for opening and closing electric circuits, esp those that pass high currents
    [Collins]

    FR

    dispositif de coupure
    appareil destiné à établir ou à interrompre le courant dans un ou plusieurs circuits électriques
    Source: 441-14-01 MOD
    [IEV number 442-01-46]

    Параллельные тексты EN-RU

    distribution board

    assembly containing different types of switchgear and controlgear associated with one or more outgoing electric circuits fed from one or more incoming electric circuits, together with terminals for the neutral and protective conductors.

    [IEV number 826-16-08]

    распределительная панель

    НКУ, состоящее из коммутационных устройств или устройств защиты (например, плавких предохранителей), присоединенных к одной или нескольким выходным цепям с питанием от одной или нескольких входящих цепей, а также зажимов для нейтрального проводника и проводников цепей защиты. Оно может также содержать сигнальные устройства и другие устройства контроля.

    [ ГОСТ Р 51321. 3-99 ( МЭК 60439-3-90)]


    Тематики

    • аппарат, изделие, устройство...

    EN

    DE

    FR

     

    распределительное устройство
    Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [РД 34.20.185-94]

    распределительное устройство

    Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
    Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
    [ ГОСТ 24291-90]
    [ ГОСТ Р 53685-2009]

    электрическое распределительное устройство
    распределительное устройство
    Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
    Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
    [ОСТ 45.55-99]

    распределительное устройство
    Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [ПОТ Р М-016-2001]
    [РД 153-34.0-03.150-00]

    устройство распределительное
    Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    EN

    switching substation
    a substation which includes switchgear and usually busbars, but no power transformers
    [IEV number 605-01-02]

    FR

    poste de sectionnement
    poste de coupure

    poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
    [IEV number 605-01-02]

    В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
    На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]


    КЛАССИФИКАЦИЯ

    В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:

    • по назначению:
      • генерирующие,
      • преобразовательно-распределительные,
      • потребительские.

        Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;

     Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласно ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:

    для электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
    для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.

    Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.

    Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.

    Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.

    Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.

    • по способу управления ПС могут быть:
      • только с телесигнализацией,
      • телеуправляемыми с телесигнализацией,
      • с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).


    Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.

    В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.

    В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
     



    Several different classifications of switchgear can be made:

    A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.

    Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.

    [Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
    [ http://en.wikipedia.org/wiki/High_voltage_switchgear]

    Тематики

    Синонимы

    EN

    DE

    FR

    Англо-русский словарь нормативно-технической терминологии > switchgear

  • 67 assembly equipped with devices limiting internal arc effects

    1. НКУ с устройствами ограничения воздействия внутренней дуги

     

    НКУ с устройствами ограничения воздействия внутренней дуги
    -
    [Интент]

    Параллельные тексты EN-RU

    Assemblies equipped with devices limiting internal arc effects (active protection)

    A design philosophy which is completely different from that just considered consists in guaranteeing the resistance to internal arcing by installing devices limiting the arc.

    The approaches in that direction can be of two different types:
    • limiting the destructive effects of the arc, once it has occured, by means of arc detectors
    • limiting the destructive effects of the arc, once it has occured, by means of overpressure detectors.

    The first possibility consists in installing in the assembly arc detectors which sense the light flux associated with the electric arc phenomenon.

    Once the arc has been detected, these devices send an opening signal to the incoming circuit-breaker, thus guaranteeing tripping times of the order of 1-2 ms, therefore shorter than those proper of the circuit-breaker.

    The operating logic of an arc detector is the following: the occurrence of an arc inside the switchboard is detected by the arc detector because an intense light radiation is associated with this phenomenon.

    The arcing control system detects the event and sends a tripping signal to the circuit-breaker.

    All the above with trip times of a few milliseconds and supplanting the tripping of the CB overcurrent relay which, for example, could be delayed due to current selectivity questions.

    Figure 1 shows the possible positions where this device can be installed inside a switchboard.

    The ideal solution is that which provides the installation of at least one detector for each column, with the consequent reduction to a minimum of the length of the optical fibers carrying the signal.

    In order to prevent from an unwanted tripping caused by light sources indepent of the arc (lamps, solar radiation etc.), an additional current sensor is often positioned at the incoming of the main circuit-breaker.

    Only in the event of an arc, both the incoming sensor which detects an “anomalous” current due to the arc fault as well as the sensor detecting the light radiation as sociated with the arc enable the system to intervene and allow the consequent opening of the circuit-breaker.

    The second possibility consists in installing overpressure sensors inside the switchboard.

    As previously described, the overpressure wave is one of the other effects occurring inside an assembly in case of arcing.

    As a consequence it is possible to install some pressure sensors which are able to signal the pressure peak associated with the arc ignition with a delay of about 10-15 ms.

    The signal operates on the supply circuit-breaker without waiting for the trip times of the selectivity protections to elapse, which are necessarily longer.

    Such a system does not need any electronic processing device, since it acts directly on the tripping coil of the supply circuit-breaker.

    Obviously it is essential that the device is set at fixed trip thresholds.

    When an established internal overpressure is reached, the arc detector intervenes.

    However, it is not easy to define in advance the value of overpressure generated by an arc fault inside a switchboard.

    [ABB]

    НКУ с устройствами ограничения воздействия внутренней дуги (активная защита)

    Для решения этой задачи используются совершенно другие, отличающиеся от ранее рассмотренных, принципы, заключающиеся в том, что противодействие внутренней дуге обеспечивается применением устройств, ограничивающих саму дугу.

    Существует два типа решения проблемы в этом направлении:
    • ограничение разрушающего воздействия дуги после того, как ее обнаружат специальные устройства
    • ограничение разрушающего воздействия дуги после того, как специальные устройства обнаружат возникновение избыточного давления.

    В первом случае в НКУ устанавливают устройства обнаружения дуги, реагирующие на световой поток, сопровождающий явление электрической дуги.

    При обнаружении дуги данные устройства посылают сигнал управления на размыкание вводного автоматического выключателя. Гарантируемое время реакции составляет 1-2 мс, что меньше времени срабатывания автоматического выключателя.

    Логика работы устройства обнаружения дуги следующая: Дуга, возникшая внутри НКУ, обнаруживается датчиком, реагирующим на интенсивное световое излучение, которым сопровождается горение дуги.

    Обнаружив дугу, система управления посылает сигнал автоматическому выключателю.

    Время срабатывания датчика и системы управления составляет несколько миллисекунд, что меньше времени срабатывания автоматического выключателя, осуществляющего защиту от сверхтока, который обычно для обеспечения требуемой селективности срабатывает с задержкой.

    На рис. 1 показаны места возможной установки устройства защиты внутри НКУ.

    Идеальным решением является установка, по крайней мере, одного устройства защиты в каждый шкаф многошкафного НКУ.

    Это позволит до минимума сократить длину оптоволоконных кабелей передачи сигнала.

    Для предотвращения ложного срабатывания от других источников света (т. е. не от дуги), например, таких как лампы, солнечное излучение и т. п., дополнительно в главной цепи вводного автоматического выключателя устанавливают датчик тока.

    Только при наличии двух событий, а именно: срабатывания датчика света и обнаружения аномального увеличения тока, система управления считает, что возникла электрическая дуга и подает команду на отключение вводного автоматического выключателя.

    Второе решение заключается в установке внутри НКУ датчика избыточного давления.

    Как было описано ранее, одним из характерных проявлений электрической дуги, возникшей внутри НКУ, является ударная волна.

    Это означает, что можно установить несколько датчиков давления, задачей которых является обнаружение импульса давления (с задержкой 10…15 мс), обусловленного зажиганием дуги.

    Сигнал от датчиков давления поступает на вводной автоматический выключатель, который срабатывает без задержки на обеспечение селективности.

    Такая система не нуждается в электронном устройстве обработки информации, поскольку воздействует непосредственно на независимый расцепитель автоматического выключателя.

    Вполне понятно, что такое устройство имеет фиксированный порог срабатывания.

    Датчик-реле дуги сработает, как только будет достигнуто заданное значение избыточного давления.

    Следует иметь в виду, что не так легко заранее определить значение избыточного давления, которое будет создано при зажигании дуги внутри НКУ.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    Англо-русский словарь нормативно-технической терминологии > assembly equipped with devices limiting internal arc effects

  • 68 co-ordination

    1. координация (контакторов и пускателей) с устройствами защиты от короткого замыкания

     

    координация (контакторов и пускателей) с устройствами защиты от короткого замыкания
    -

    7.2.5 Координация с аппаратами защиты от коротких замыканий

    7.2.5.1 Работоспособность в условиях короткого замыкания (номинальный условный ток короткого замыкания)

    ... Допускается координация двух типов — 1 или 2....
    Координация типа 1 требует, чтобы в условиях короткого замыкания контактор или пускатель не создавали опасности для людей или оборудования, хотя они могут оказаться непригодными для дальнейшей эксплуатации без ремонта и замены частей.
    Координация типа 2 требует, чтобы в условиях короткого замыкания контактор или пускатель не создавали опасности для людей или оборудования и оставались пригодными для дальнейшей эксплуатации. Возможность сваривания контактов допускается, и в этом случае изготовитель должен рекомендовать меры по обслуживанию аппаратов.
    [ ГОСТ Р 50030.4.1-2002 (МЭК 60947-4-1-2000)]

    Параллельные тексты EN-RU

    Co-ordination type 1 and type 2

    The co-ordination typologies admitted by the Standard with reference to the behavior of the protection device against short-circuit towards the starter components are classified as “type 1” and “type 2”.

    Under short-circuit conditions, the coordination of type “1” allows the contactor and the overload relay to be damaged; as a consequence they could not be able to operate without repairing or replacement of parts.
    However, the Standard prescribes that these devices do not cause damages to people or installations, for example with parts of the components ejected outside the enclosure.

    Under short-circuit conditions, the coordination of type “2” allows the risk of contact welding, provided that the contacts themselves can be easily separated (for example through a screwdriver) without important deformations.
    This type of coordination requires that the contactor or the starter do not cause damages to people or installation and that they are able to resume operation after restoring of the standard conditions.

    From the definition of the two coordination typologies it is possible to deduce how “type 1” coordination permits the use of devices of lower sizes, thus with an initial cost saving and reduced dimensions, but to the disadvantage of a high safety and however with subsequent costs for maintenance and replacement in case of faults.
    “Type 2” coordination meets higher safety requirements and the possible greater initial cost can be amortized considering that, in case of fault, the switching and protection equipment could start operating again without being replaced.

    [ABB]

    Координация типа 1 и 2 с аппаратами защиты от коротких замыканий

    Стандарт определяет два типа координации компонентов пускателя с аппаратами защиты от короткого замыкания: тип 1 и тип 2.

    Координация типа 1. В условиях короткого замыкания допускается повреждение контактора и теплового реле, в результате чего они могут оказаться непригодными для дальнейшей эксплуатации без ремонта и замены частей. При этом данные устройства не должны создавать опасности для людей и оборудования, например, вследствие вылета частей пускателя из оболочки.


    Координация типа 2. В условиях короткого замыкания допускает сваривание контактов при условии, что они могут быть легко разъединены (например, отверткой) без заметной деформации. Контактор и тепловое реле не должны создавать опасности для людей и оборудования и должны оставаться пригодными для дальнейшей эксплуатации после восстановления нормальных условий.

    Из определения двух типов координации можно сделать вывод, что координация типа 1 позволяет использовать устройства, рассчитанные на меньшие рабочие токи, обеспечивая таким образом экономию на первоначальных затратах и сокращение размеров устройств, но снижая при этом уровень безопасности и приводя впоследствии к расходам на техническое обслуживание и замену в случае возникновения неисправности.
    Координация типа 2 отвечает более высоким требованиям безопасности и имеет большие первоначальные расходы, которые могут быть компенсированы тем, что в случае возникновения неисправности эксплуатация коммутационных и защитных аппаратов может быть продолжена без замены их частей.

    [Перевод Интент]

     

    Тематики

    EN

    Англо-русский словарь нормативно-технической терминологии > co-ordination

  • 69 switching substation

    1. распределительное устройство
    2. подстанция
    3. переключательный пункт
    4. (электрическое) распределительное устройство

     

    переключательный пункт

    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    Тематики

    • электротехника, основные понятия

    EN

     

    подстанция
    Электроустановка, предназначенная для преобразования и распределения электрической энергии.
    [ ГОСТ 19431-84]

    подстанция
    Подстанцией (ПС) называется электроустановка, служащая для преобразования и распределения электроэнергии и состоящая из трансформаторов или других преобразователей энергии, распределительных устройств, устройств управления и вспомогательных сооружений.
    [РД 34.20.185-94]

    подстанция

    Электроустановка, предназначенная для приема, преобразования и распределения электрической энергии, состоящая из трансформаторов или других преобразователей электрической энергии, устройств управления, распределительных и вспомогательных устройств по ГОСТ 19431.
    [ ГОСТ 24291-90]

    подстанция электрическая
    Группа установок и оборудования, размещаемая в здании или на открытой площадке, предназначенная для преобразования параметров передаваемой электроэнергии или распределения её
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    электрическая подстанция
    Электроустановка, предназначенная для преобразования и распределения электрической энергии.
    [ПОТ Р М-016-2001]
    [РД 153-34.0-03.150-00]

    EN

    substation (of a power system)
    a part of an electrical system, con-fined to a given area, mainly including ends of transmission or distribution lines, electrical switchgear and controlgear, buildings and transformers. A substation generally includes safety or control devices (for example protection)
    NOTE – The substation can be qualified according to the designation of the system of which it forms a part. Examples: transmission substation (transmission system), distribution substation, 400 kV or 20 kV substation.
    [IEV number 601-03-02 ]

    FR

    poste (d'un réseau électrique)
    partie d'un réseau électrique, située en un même lieu, comprenant principalement les extrémités des lignes de transport ou de distribution, de l'appareillage électrique, des bâtiments, et, éventuellement, des transformateurs. Un poste comprend généralement les dispositifs destinés à la sécurité et à la conduite du réseau (par exemple les protections)
    NOTE – Selon le type de réseau auquel appartient le poste, il peut être qualifié par la désignation du réseau. Exemples: poste de transport (réseau de transport), poste de distribution, poste à 400 kV, poste à 20 kV.
    [IEV number 601-03-02 ]

    Подстанции с трансформаторами, преобразующие электрическую энергию только по напряжению, называются трансформаторными; а преобразующие электроэнергию по напряжению и другим параметрам (изменение частоты, выпрямление тока), — преобразовательными. На ПС могут устанавливаться два и более, как правило, трехфазных трансформатора. Установка более двух трансформаторов принимается на основе технико-экономических расчетов, а также в случаях, когда на ПС применяется два средних напряжения. При отсутствии трехфазного трансформатора необходимой мощности, а также при транспортных ограничениях возможно применение группы однофазных трансформаторов. Подстанция, как правило, состоит из нескольких РУ разных ступеней напряжения, соединенных между собой трансформаторной (автотрансформаторной) связью;
    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]

    Тематики

    Синонимы

    EN

    DE

    FR

     

    распределительное устройство
    Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [РД 34.20.185-94]

    распределительное устройство

    Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
    Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
    [ ГОСТ 24291-90]
    [ ГОСТ Р 53685-2009]

    электрическое распределительное устройство
    распределительное устройство
    Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
    Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
    [ОСТ 45.55-99]

    распределительное устройство
    Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [ПОТ Р М-016-2001]
    [РД 153-34.0-03.150-00]

    устройство распределительное
    Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    EN

    switching substation
    a substation which includes switchgear and usually busbars, but no power transformers
    [IEV number 605-01-02]

    FR

    poste de sectionnement
    poste de coupure

    poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
    [IEV number 605-01-02]

    В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
    На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]


    КЛАССИФИКАЦИЯ

    В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:

    • по назначению:
      • генерирующие,
      • преобразовательно-распределительные,
      • потребительские.

        Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;

     Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласно ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:

    для электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
    для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.

    Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.

    Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.

    Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.

    Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.

    • по способу управления ПС могут быть:
      • только с телесигнализацией,
      • телеуправляемыми с телесигнализацией,
      • с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).


    Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.

    В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.

    В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
     



    Several different classifications of switchgear can be made:

    A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.

    Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.

    [Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
    [ http://en.wikipedia.org/wiki/High_voltage_switchgear]

    Тематики

    Синонимы

    EN

    DE

    FR

    3 (электрическое) распределительное устройство; РУ

    Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.

    Примечание. К устройствам управления относятся аппараты и связывающие их элементы, обеспечивающие контроль, измерение, сигнализацию и выполнение команд

    605-01-02**

    de Schaltstation

    en switching substation

    fr poste de sectionnement, poste de coupure

    Источник: ГОСТ 24291-90: Электрическая часть электростанции и электрической сети. Термины и определения оригинал документа

    Англо-русский словарь нормативно-технической терминологии > switching substation

  • 70 fault

    1. ток повреждения
    2. сверхток
    3. сброс
    4. сбой
    5. разлом
    6. повреждение (цепи, линии, устройства)
    7. повреждение (во взрывозащите)
    8. повреждение
    9. ошибка
    10. отказ
    11. ненормальный режим работы
    12. неисправность
    13. неисправное состояние
    14. нарушение
    15. короткое замыкание
    16. дизъюктивное нарушение
    17. дефект
    18. выход из строя
    19. аварийное сообщение

     

    аварийное сообщение
    -

    Параллельные тексты EN-RU

    The system offers diagnostic and statistics functions and configurable warnings and faults, allowing better prediction of component maintenance, and provides data to continuously improve the entire system.
    [Schneider Electric]

    Система (управления электродвигателем) предоставляет оператору различную диагностическую и статистическую информацию и позволяет сконфигурировать предупредительные и аварийные сообщения, что дает возможность лучше планировать техническое обслуживание и постоянно улучшать систему в целом.
    [Перевод Интент]

    Various alarm notifications are available to indicate a compromised security state such as forced entry and door position.
    [APC]

    Устройство может формировать различные аварийные сообщения о нарушении защиты, например, о несанкционированном проникновении или об изменении положения двери.
    [Перевод Интент]


    Тематики

    EN

     

    выход из строя

    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    выход системы из строя
    вследствие отказа аппаратного или программного обеспечения либо средств связи
    [Англо-русский толковый словарь терминов и сокращений по ВТ, Интернету и программированию. © 1998-2007 гг., Э.М. Пройдаков, Л.А. Теплицкий. 13,8 тыс. статей.]

    выход из строя
    -

    [Интент]

    Единичные выходы из строя в процессе испытаний элементов электронной техники (микросхем, электровакуумных и полупроводниковых приборов, конденсаторов, резисторов, кварцевых резонаторов и т.д.), а также ламп накаливания и предохранителей не могут служить основанием для прекращения испытаний, если это не вызвано недостатком конструкции прибора.

    При повторных выходах из строя тех же элементов испытания следует считать неудовлетворительными.
    [ ГОСТ 24314-80]

    При выходе из строя отдельно стоящих вентиляторов на двигателях мельниц, дымососов, мельничных вентиляторов, вентиляторов первичного воздуха и т.д. необходимо при первой возможности, но не позже чем его допускается заводской инструкцией, отключить двигатель 6 кВ для ремонта вентилятора охлаждения двигателя.
    [РД 34.20.565]

    Судовая электрическая сеть, предназначенная для передачи электроэнергии при выходе из строя линий электропередачи силовой сети или исчезновении напряжения
    [ ГОСТ 22652-77]

    Тематики

    Синонимы

    EN

     

    дизъюктивное нарушение
    Относительное перемещение частей пластов вдоль плоскости их разрыва (геол.)
    [ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]

    Тематики

    EN

     

    короткое замыкание
    Случайное или намеренное соединение резистором или импедансом со сравнительно низким сопротивлением двух или более точек в цепи, нормально находящихся под различным напряжением.
    Случайное или намеренное низкоимпедансное или низкоомное соединение двух или более точек электрической цепи, нормально находящихся под разными электрическими потенциалами. (вариант компании Интент)
    МЭК 60050(151-03-41) [2].
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    короткое замыкание
    Случайный или преднамеренный проводящий путь между двумя или более проводящими частями, принуждающий различия электрических потенциалов между этими проводящими частями становиться равными или близкими к нулю.
    Короткое замыкание обычно возникает в аварийном режиме электроустановки здания при повреждении изоляции токоведущих частей, находящихся под разными электрическими потенциалами, и возникновении между этими частями электрического контакта, имеющего пренебрежимо малое полное сопротивление. Короткое замыкание также может быть следствием ошибочных действий, совершаемых персоналом при монтаже и эксплуатации электроустановки здания, когда соединяют между собой проводящие части, которые в нормальном режиме находятся под разными электрическими потенциалами.
    Короткое замыкание характеризуется током короткого замыкания, который, многократно превышая номинальный ток электрической цепи, может вызвать возгорание её элементов и явиться причиной пожара в здании. Поэтому в электроустановках зданий всегда проводят мероприятия, направленные на снижение вероятности возникновения короткого замыкания, а также выполняют защиту от короткого замыкания с помощью устройств защиты от сверхтока.
    [ http://www.volt-m.ru/glossary/letter/%CA/view/27/]

    короткое замыкание
    Случайное или преднамеренное соединение двух или более проводящих частей, вызывающее снижение разности электрических потенциалов между этими частями до нуля или значения, близкого к нулю.
    [ ГОСТ Р МЭК 60050-195-2005]

    короткое замыкание
    КЗ

    замыкание, при котором токи в ветвях электроустановки, примыкающих к месту его возникновения, резко возрастают, превышая наибольший допустимый ток продолжительного режима
    [Методические указания по защите распределительных электрических сетей напряжением 0,4-10 кВ от грозовых перенапряжений]

    EN

    short-circuit
    accidental or intentional conductive path between two or more conductive parts forcing the electric potential differences between these conductive parts to be equal to or close to zero
    Source: 151-03-41 MOD
    [IEV number 195-04-11]

    FR

    court-circuit
    chemin conducteur accidentel ou intentionnel entre deux ou plusieurs parties conductrices forçant les différences de potentiel électriques entre ces parties conductrices à être nulles ou proches de zéro
    Source: 151-03-41 MOD
    [IEV number 195-04-11]

    Параллельные тексты EN-RU

    A short-circuit is a low impedance connection between two conductors at different voltages.
    [ABB]

    Короткое замыкание представляет собой низкоомное соединение двух проводников, находящихся под разными потенциалами.
    [Перевод Интент]

    Тематики

    Синонимы

    • КЗ

    EN

    DE

    FR

     

    нарушение
    [Департамент лингвистических услуг Оргкомитета «Сочи 2014». Глоссарий терминов]

    EN

    fault
    Another term for offense.
    [Департамент лингвистических услуг Оргкомитета «Сочи 2014». Глоссарий терминов]

    Тематики

    EN

     

    неисправное состояние
    Состояние объекта, при котором он не соответствует хотя бы одному из требований нормативно-технической и (или) конструкторской (проектной) документации.
    [ ГОСТ 27.002-89]
    [ОСТ 45.152-99]

    неисправное состояние
    неисправность

    По ГОСТ 13377-75
    [ ГОСТ 24166-80]

    неисправное состояние
    Состояние системы тревожной сигнализации, препятствующее реагированию системы на наличие опасности в соответствии с требованиями стандартов.
    [ ГОСТ Р 50775-95]
    [МЭК 839-1-1-88]

    Тематики

    Обобщающие термины

    Синонимы

    EN

    DE

    FR

     

    неисправность
    отказ в работе

    Состояние машины, характеризующееся неспособностью выполнять заданную функцию, исключая случаи проведения профилактического технического обслуживания, других запланированных действий или недостаток внешних ресурсов (например, отключение энергоснабжения).
    Примечание 1
    Неисправность часто является результатом повреждения самой машины, однако она может иметь место и без повреждения.
    Примечание 2
    На практике термины «неисправность», «отказ» и «повреждение» часто используются как синонимы.
    [ ГОСТ Р ИСО 12100-1:2007]

    неисправность

    Состояние оборудования, характеризуемое его неспособностью выполнять требуемую функцию, исключая профилактическое обслуживание или другие планово-предупредительные действия, а также исключая неспособность выполнять требуемую функцию из-за недостатка внешних ресурсов.
    Примечание - Неисправность часто является следствием отказа самого оборудования, но может существовать и без предварительного отказа.
    [ГОСТ ЕН 1070-2003]

    неисправность
    Состояние технического объекта (элемента), характеризуемое его неспособностью выполнять требуемую функцию, исключая периоды профилактического технического обслуживания или другие планово-предупредительные действия, или в результате недостатка внешних ресурсов.
    Примечания
    1 Неисправность является часто следствием отказа самого технического объекта, но может существовать и без предварительного отказа.
    2 Английский термин «fault» и его определение идентичны данному в МЭК 60050-191 (МЭС 191-05-01) [1]. В машиностроении чаще применяют французский термин «defaut» или немецкий термин «Fehler», чем термины «panne» и «Fehlzusstand», которые употребляют с этим определением.
    [ ГОСТ Р ИСО 13849-1-2003]

    Тематики

    EN

    DE

    FR

     

    ненормальный режим работы электротехнического изделия
    Режим работы электротехнического изделия (электротехнического устройства, электрооборудования), при котором значение хотя бы одного из параметров режима выходит за пределы наибольшего или наименьшего рабочего значения.
    [ ГОСТ 18311-80]


    К ненормальным относятся режимы, связанные с отклонениями от допустимых значений величин тока, напряжения и частоты, опасные для оборудования или устойчивой работы энергосистемы.

    Рассмотрим наиболее характерные ненормальные режимы.

    а) Перегрузка оборудования, вызванная увеличением тока сверх номинального значения. Номинальным называется максимальный ток, допускаемый для данного оборудования в течение неограниченного времени.
    Если ток, проходящий по оборудованию, превышает номинальное значение, то за счет выделяемого им дополнительного тепла температура токоведущих частей и изоляции через некоторое время превосходит допустимую величину, что приводит к ускоренному износу изоляции и ее повреждению. Время, допустимое для прохождения повышенных токов, зависит от их величины. Характер этой зависимости показан на рис. 1-3 и определяется конструкцией оборудования и типом изоляционных материалов. Для предупреждения повреждения оборудования при его перегрузке необходимо принять меры к разгрузке или отключению оборудования.

    б) Качания в системах возникают при выходе из синхронизма работающих параллельно генераторов (или электростанций) А и В (рис. 1-2, б). При качаниях в каждой точке системы происходит периодическое изменение («качание») тока и напряжения. Ток во всех элементах сети, связывающих вышедшие из синхронизма генераторы А и В, колеблется от нуля до максимального значения, во много раз превышающего нормальную величину. Напряжение падает от нормального до некоторого минимального значения, имеющего разную величину в каждой точке сети. В точке С, называемой электрическим центром качаний, оно снижается до нуля, в остальных точках сети напряжение падает, но остается больше нуля, нарастая от центра качания С к источникам питания А и В. По характеру изменения тока и напряжения качания похожи на к. з. Возрастание тока вызывает нагревание оборудования, а уменьшение напряжения нарушает работу всех потребителей системы. Качание — очень опасный ненормальный режим, отражающийся на работе всей энергосистемы.

    в) Повышение напряжения сверх допустимого значения возникает обычно на гидрогенераторах при внезапном отключении их нагрузки. Разгрузившийся гидрогенератор увеличивает частоту вращения, что вызывает возрастание э. д. с. статора до опасных для его изоляции значений. Защита в таких случаях должна снизить ток возбуждения генератора или отключить его.
    Опасное для изоляции оборудования повышение напряжения может возникнуть также при одностороннем отключении или включении длинных линий электропередачи с большой емкостной проводимостью.
    Кроме отмеченных ненормальных режимов, имеются и другие, ликвидация которых возможна при помощи релейной защиты.

    [Чернобровов Н. В. Релейная защита. Учебное пособие для техникумов]

    Тематики

    Синонимы

    EN

     

    отказ
    Нарушение способности оборудования выполнять требуемую функцию.
    Примечания
    1. После отказа оборудование находится в неисправном состоянии.
    2. «Отказ» является событием, в отличие от «неисправности», которая является состоянием.
    3. Это понятие, как оно определено, не применяют к оборудованию объекту, состоящему только из программных средств.
    4. На практике термины «отказ» и «неисправность» часто используют как синонимы.
    [ГОСТ ЕН 1070-2003]
    [ ГОСТ Р ИСО 13849-1-2003]
    [ ГОСТ Р МЭК 60204-1-2007]

    отказ
    Событие, заключающееся в нарушении работоспособного состояния объекта.
    [ ГОСТ 27.002-89]
    [ОСТ 45.153-99]
    [СТО Газпром РД 2.5-141-2005]
    [СО 34.21.307-2005]

    отказ
    Событие, заключающееся в нарушении работоспособного состояния машины и (или) оборудования вследствие конструктивных нарушений при проектировании, несоблюдения установленного процесса производства или ремонта, невыполнения правил или инструкций по эксплуатации.
    [Технический регламент о безопасности машин и оборудования]

    EN

    failure
    the termination of the ability of an item to perform a required function
    NOTE 1 – After failure the item has a fault.
    NOTE 2 – "Failure" is an event, as distinguished from "fault", which is a state.
    NOTE 3 – This concept as defined does not apply to items consisting of software only.
    [IEV number 191-04-01]
    NOTE 4 - In practice, the terms fault and failure are often used synonymously
    [IEC 60204-1-2006]

    FR

    défaillance
    cessation de l'aptitude d'une entité à accomplir une fonction requise
    NOTE 1 – Après défaillance d'une entité, cette entité est en état de panne.
    NOTE 2 – Une défaillance est un passage d'un état à un autre, par opposition à une panne, qui est un état.
    NOTE 3 – La notion de défaillance, telle qu'elle est définie, ne s'applique pas à une entité constituée seulement de logiciel.
    [IEV number 191-04-01]

    Тематики

    Обобщающие термины

    EN

    DE

    FR

     

    повреждение
    Повреждение любого элемента, разделения, изоляции или соединения между элементами, не являющихся неповреждаемыми по МЭК 60079-11 [8], при проведении испытаний на искробезопасность.
    [ ГОСТ Р МЭК 60050-426-2006]


    Тематики

    EN

     

    повреждение (цепи, линии, устройства)
    -

    [Интент]

    Тематики

    EN

     

    разлом

    [ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    EN

    fault
    A fracture or a zone of fractures along which there has been displacement of the sides relative to one another parallel to the fracture. (Source: BJGEO)
    [http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    Тематики

    EN

    DE

    FR

     

    сбой
    Самоустраняющийся отказ или однократный отказ, устраняемый незначительным вмешательством оператора.
    [ ГОСТ 27.002-89]
    [ОСТ 45.153-99]
    [СТО Газпром РД 2.5-141-2005]

    сбой
    Ненормальный режим, который может вызвать уменьшение или потерю способности функционального блока выполнять требуемую функцию.
    Примечание
    МЭС 191-05-01 определяет «сбой» как состояние, характеризуемое неспособностью выполнить необходимую функцию, исключая неспособности, возникающие во время профилактического ухода или других плановых мероприятий, либо в результате недостатка внешних ресурсов. Иллюстрация к этим двум точкам зрения показана на рисунке [ ИСО / МЭК 2382-14-01-10].
    3743
    [ ГОСТ Р МЭК 61508-4-2007]

    Тематики

    Обобщающие термины

    EN

     

    сброс
    Разрывное нарушение, при котором сместитель падает в сторону опущенного крыла (висячее крыло опущено относительно лежачего).
    [ Словарь геологических терминов и понятий. Томский Государственный Университет]

    Тематики

    • геология, геофизика

    Обобщающие термины

    EN

     

    сверхток
    Любой ток, превышающий номинальный
    МЭК 60050(441-11-06).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    [ ГОСТ Р 50345-99( МЭК 60898-95)]

    сверхток
    Электрический ток, превышающий номинальный электрический ток.
    Сверхток представляет собой любой электрический ток, величина которого превышает номинальный ток какого-либо элемента электроустановки здания или используемого в ней электрооборудования, например: номинальный ток электрической цепи, допустимый длительный ток проводника, номинальный ток автоматического выключателя и т. д. В нормативной и правовой документации различают два основных вида сверхтока – ток перегрузки и ток короткого замыкания.
    Появление сверхтока в каком-либо элементе электроустановки здания может привести к его перегреву, возгоранию и, как следствие, к возникновению пожара в здании. Поэтому в электроустановках зданий выполняют защиту от сверхтока.
    [ http://www.volt-m.ru/glossary/letter/%D1/view/59/]

    сверхток
    сверхток в электротехническом изделии
    Ток, значение которого превосходит наибольшее рабочее значение тока электротехнического изделия (устройства).
    [ ГОСТ 18311-80]

    сверхток
    Электрический ток, превышающий номинальный электрический ток.
    Примечание - Для проводников номинальный ток считается равным длительному допустимому току.
    [ ГОСТ Р МЭК 60050-826-2009]

    Сверхток может оказывать или может не оказывать вредные воздействия в зависимости от его величины и продолжительности. Сверхтоки могут возникать в результате перегрузок в электроприемниках или при повреждениях, таких как короткие замыкания или замыканиях на землю
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    сверхток
    Любой ток, превышающий номинальное значение. Для проводов номинальным значением является допустимый ток.
    [ ГОСТ Р МЭК 60204-1-2007]

    EN

    overcurrent
    electric current exceeding the rated electric current
    NOTE – For conductors, the rated current is considered as equal to the current-carrying capacity
    [IEV number 826-11-14]


    over-current
    <>current exceeding the rated current
    <>[IEC 61095, ed. 2.0 (2009-02)]


    over-current
    electric current the value of which exceeds a specified limiting value
    [IEV number 151-15-28]
    [IEV number 442-01-20]

    FR

    surintensité, f
    courant électrique supérieur au courant électrique assigné
    NOTE – Pour des conducteurs, on considère que le courant assigné est égal au courant admissible.
    [IEV number 826-11-14]


    surintensité
    courant supérieur au courant assigné
    [IEC 61095, ed. 2.0 (2009-02)]
    [IEV number 442-01-20]
    surintensité, f
    courant électrique dont la valeur dépasse une valeur limite spécifiée
    [IEV number 151-15-28]

    Параллельные тексты EN-RU

    The design of LV installations leads to basic protection devices being fitted for three types of faults:

    • overloads
    • short-circuits
    • insulation faults
    [Schneider Electric]

    Низковольтные электроустановки должны быть оснащены устройствами защиты трех типов:

    • от перегрузки;
    • от короткого замыкания;
    • от токов утечки.

    [Перевод Интент]

    Примечание
    .
    Слово fault в данном случае пришлось опустить, поскольку:
    - его нельзя перевести как "неисправность", т. к. возникновение 
    перегрузки ( overload) не является неисправностью;
    - его нельзя перевести как "сверхток", т. к. ток утечки не является сверхтоком
    .

    The chosen switchgear must withstand and eliminate faults at optimised cost with respect to the necessary performance.
    [Schneider Electric]

    Выбранная аппаратура распределения должна иметь такие характеристики, чтобы рентабельно выдерживать и ограничивать сверхтоки.
    [Перевод Интент]

     

    Тематики

    Синонимы

    EN

    DE

    FR

     

    ток повреждения
    Ток, возникающий в результате пробоя или перекрытия изоляции.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    ток повреждения
    Ток, который протекает через данную точку повреждения в результате повреждения изоляции.
    [ ГОСТ Р МЭК 60050-826-2009]

    EN

    fault current
    current resulting from an insulation failure, the bridging of insulation or incorrect connection in an electrical circuit
    [IEC 61439-1, ed. 2.0 (2011-08)]

    fault current

    current which flows across a given point of fault resulting from an insulation fault
    [IEV number 826-11-11]

    FR

    courant de défaut
    courant résultant d'un défaut de l'isolation, du contournement de l’isolation ou d’un raccordement incorrect dans un circuit électrique
    [IEC 61439-1, ed. 2.0 (2011-08)]

    courant de défaut, m

    courant s'écoulant en un point de défaut donné, consécutivement à un défaut de l'isolation
    [IEV number 826-11-11]

    Тематики

    EN

    DE

    • Fehlerstrom, m

    FR

    • courant de défaut, m

    3.7.2 повреждение (fault): Повреждение любого элемента, разделения, изоляции или соединения между элементами, не являющимися по настоящему стандарту не повреждаемыми, от которых зависит искробезопасность цепи.

    Источник: ГОСТ Р 52350.11-2005: Электрооборудование для взрывоопасных газовых сред. Часть 11. Искробезопасная электрическая цепь "I" оригинал документа

    3.16 неисправность (fault): Состояние объекта, характеризующееся неспособностью исполнять требуемую функцию, исключая время профилактического технического обслуживания или других запланированных действий, или простои из-за недостатка внешних ресурсов

    Примечание - Неисправность часто является результатом отказа объекта, но может существовать и без отказа.

    Источник: ГОСТ Р 51901.6-2005: Менеджмент риска. Программа повышения надежности оригинал документа

    3.6 неисправность (fault): Состояние элемента, характеризующееся неспособностью исполнять требуемую функцию, исключая период технического обслуживания, ремонта или других запланированных действий, а также из-за недостатка внешних ресурсов.

    Примечание - Неисправность часто является результатом отказа элемента, но может существовать и без предшествующего отказа.

    Источник: ГОСТ Р 51901.5-2005: Менеджмент риска. Руководство по применению методов анализа надежности оригинал документа

    3.5 неисправность (fault): Состояние объекта, когда один из его элементов или группа элементов проявляют признаки деградации или нарушения работы, что может привести к отказу машины.

    Примечания

    1 Неисправность часто является следствием отказа, но может иметь место и при его отсутствии.

    2 Состояние объекта не рассматривают как неисправное, если оно возникло вследствие запланированных процедур или нехватки внешних ресурсов.

    Источник: ГОСТ Р ИСО 13379-2009: Контроль состояния и диагностика машин. Руководство по интерпретации данных и методам диагностирования оригинал документа

    3.3 неисправность (fault): Состояние объекта, при котором он не способен выполнять требуемую функцию, за исключением такой неспособности при техническом обслуживании или других плановых мероприятиях или вследствие нехватки внешних ресурсов.

    Примечания

    1 Неисправность часто является следствием отказа объекта, но может иметь место и без него.

    2 В настоящем стандарте термин «неисправность» используется наряду с термином «отказ» по историческим причинам.

    Источник: ГОСТ Р 51901.12-2007: Менеджмент риска. Метод анализа видов и последствий отказов оригинал документа

    3.1.30 ошибка (fault): Разность между погрешностью весоизмерительного датчика и основной погрешностью весоизмерительного датчика (см. 3.1.34).

    Источник: ГОСТ Р 8.726-2010: Государственная система обеспечения единства измерений. Датчики весоизмерительные. Общие технические требования. Методы испытаний оригинал документа

    3.6 дефект (fault): Неисправность или ошибка в компоненте технического обеспечения, программного обеспечения или системы

    [МЭК 61513, пункт 3.22]

    Примечание 1 - Дефекты могут подразделяться на случайные, например, в результате ухудшения аппаратных средств из-за старения, и систематические, например, ошибки в программном обеспечении, которые вытекают из погрешностей проектирования.

    Примечание 2 - Дефект (в особенности дефект проекта) может остаться необнаруженным в системе до тех пор, пока не окажется, что полученный результат не соответствует намеченной функции, то есть возникает отказ.

    Примечание 3 - См. также «ошибка программного обеспечения» и «случайный дефект».

    Источник: ГОСТ Р МЭК 62340-2011: Атомные станции. Системы контроля и управления, важные для безопасности. Требования по предотвращению отказов по общей причине оригинал документа

    3.2 неисправность (fault): Состояние объекта, когда один из его элементов или группа элементов проявляет признаки деградации или нарушения работы, что может привести к отказу машины.

    Примечание - Неисправность может привести к отказу.

    Источник: ГОСТ Р ИСО 17359-2009: Контроль состояния и диагностика машин. Общее руководство по организации контроля состояния и диагностирования оригинал документа

    3.17 дефект (fault): Неисправность или ошибка в компоненте технического обеспечения, программного обеспечения или системы.

    [МЭК 61513, пункт 3.22]

    Источник: ГОСТ Р МЭК 60880-2010: Атомные электростанции. Системы контроля и управления, важные для безопасности. Программное обеспечение компьютерных систем, выполняющих функции категории А оригинал документа

    3.6.1 сбой (fault): Ненормальный режим, который может вызвать уменьшение или потерю способности функционального блока выполнять требуемую функцию.

    Примечание - МЭС 191-05-01 определяет «сбой» как состояние, характеризуемое неспособностью выполнить необходимую функцию, исключая неспособности, возникающие во время профилактического ухода или других плановых мероприятий, либо в результате недостатка внешних ресурсов. Иллюстрация к этим двум точкам зрения показана на рисунке 4 [ИСО/МЭК 2382-14-01-10].

    Источник: ГОСТ Р МЭК 61508-4-2007: Функциональная безопасность систем электрических, электронных, программируемых электронных, связанных с безопасностью. Часть 4. Термины и определения оригинал документа

    3.22 дефект (fault): Дефект в аппаратуре, программном обеспечении или в компоненте системы (см. рисунок 3).

    Примечание 1 -Дефекты могут быть результатом случайных отказов, которые возникают, например, из-за деградации аппаратуры в результате старения; возможны систематические дефекты, например, в результате дефектов в программном обеспечении, возникающих из-за ошибок при проектировании.

    Примечание 2 - Дефект (особенно дефекты, связанные с проектированием) может оставаться незамеченным, пока сохраняются условия, при которых он не отражается на выполнении функции, т.е. пока не произойдет отказ.

    Примечание 3 - См. также «дефект программного обеспечения».

    Источник: ГОСТ Р МЭК 61513-2011: Атомные станции. Системы контроля и управления, важные для безопасности. Общие требования оригинал документа

    4.10.1 ошибка (fault): Разность между погрешностью показаний и погрешностью прибора.

    Источник: ГОСТ Р ЕН 1434-1-2011: Теплосчетчики. Часть 1. Общие требования

    Англо-русский словарь нормативно-технической терминологии > fault

  • 71 assembly

    1. узел оборудования
    2. сборочная единица
    3. сборка (монтаж)
    4. сборка
    5. подузел
    6. НКУ распределения и управления
    7. конструкция
    8. клеевое соединение
    9. ассемблирование

     

    ассемблирование
    Компиляция программ с языка ассемблера.
    [ ГОСТ 19781-90]

    Тематики

    • обеспеч. систем обраб. информ. программное

    EN

     

    клеевое соединение
    Ндп.
    клеенное соединение
    Соединение частей изделия склеиванием.
    [ ГОСТ 28780-90]

    Недопустимые, нерекомендуемые

    Тематики

    EN

     

    конструкция
    Устройство, взаимное расположение частей и состав машины, механизма или сооружения.
    [ http://sl3d.ru/o-slovare.html]

    Параллельные тексты EN-RU

    The new valve profile is design to ensure smooth and precise control at low capacities for improved part load performances.
    [Lennox]

    Вентиль новой конструкции обеспечивает плавное и точное регулирование при низкой производительности холодильного контура, что увеличивает его эффективность при неполной нагрузке.
    [Интент]


    Тематики

    EN

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

     

    подузел
    узел
    сборная деталь
    собранный узел
    блок
    агрегат


    [ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]

    Тематики

    Синонимы

    EN

     

    сборка
    Процесс соединения и закрепления элементов и деталей в готовые узлы, монтажные блоки, конструкции или изделия
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    сборка
    Образование соединений составных частей изделия.
    Примечания:
    1. Примером видов сборки является клепка, сварка заготовок и т.д.
    2. Соединение может быть разъемным или неразъемным
    [ГОСТ 3.1109-82]

    Тематики

    EN

    DE

    FR

     

    сборка (монтаж)

    [А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]

    Тематики

    EN

     

    узел оборудования
    компоновочный узел
    компоновка
    ассемблирование


    [Л.Г.Суменко. Англо-русский словарь по информационным технологиям. М.: ГП ЦНИИС, 2003.]

    Тематики

    Синонимы

    EN

    3.2.10 сборочная единица (assembly): Изделие, которое разлагаемо на множество комплектующих или других сборочных единиц с точки зрения конкретного приложения предметной области;

    Источник: ГОСТ Р ИСО 10303-1-99: Системы автоматизации производства и их интеграция. Представление данных об изделии и обмен этими данными. Часть 1. Общие представления и основополагающие принципы оригинал документа

    3.3.1 конструкция (assembly) предназначена для того, чтобы:

    а) удерживать каскетку на голове;

    б) поглощать кинетическую энергию, возникающую при ударе, и распределять усилие по поверхности головы.

    Примечание - Внутренняя оснастка может состоять из элементов, указанных в 3.3.2 - 3.3.5.

    Источник: ГОСТ Р 12.4.245-2007: Система стандартов безопасности труда. Каскетки защитные. Общие технические требования. Методы испытаний оригинал документа

    Англо-русский словарь нормативно-технической терминологии > assembly

  • 72 DS

    1. цифровой стабилизатор
    2. Релаксация
    3. расширение спектра по методу прямой последовательности
    4. распределенное тестирование на одном уровне
    5. разъединитель
    6. прямая последовательность
    7. проектный стандарт
    8. пораженная секунда
    9. пароохладитель
    10. набор данных
    11. дуплексное разнесение
    12. динамическое рассеивание
    13. динамическое переключение
    14. двухсторонняя дискета
    15. водосточная труба
    16. вниз по потоку
    17. барабанный переключатель

     

    барабанный переключатель

    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    Тематики

    • электротехника, основные понятия

    EN

     

    вниз по потоку

    [А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]

    Тематики

    EN

     

    водосточная труба

    [А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]

    Тематики

    EN

     

    двухсторонняя дискета

    [Е.С.Алексеев, А.А.Мячев. Англо-русский толковый словарь по системотехнике ЭВМ. Москва 1993]

    Тематики

    EN

     

    динамическое переключение
    динамическая коммутация


    [Е.С.Алексеев, А.А.Мячев. Англо-русский толковый словарь по системотехнике ЭВМ. Москва 1993]

    Тематики

    Синонимы

    EN

     

    динамическое рассеивание

    [Е.С.Алексеев, А.А.Мячев. Англо-русский толковый словарь по системотехнике ЭВМ. Москва 1993]

    Тематики

    EN

     

    дуплексное разнесение
    (Радио)частотный разнос между соответствующими радиостволами прямого и обратного направлений (МСЭ-R F.746-7).
    [ http://www.iks-media.ru/glossary/index.html?glossid=2400324]

    Тематики

    • электросвязь, основные понятия

    EN

     

    набор данных
    Идентифицированная совокупность физических записей, организованная одним из установленных в системе обработки данных способов и представляющая файлы или части файлов в среде хранения.
    [ ГОСТ 20886-85]

    набор данных
    Множество элементов данных, объединенных в отдельное целое для решения определенной задачи.
    Чаще всего набор данных представляется в виде файла, сообщения либо блока данных.
    [Гипертекстовый энциклопедический словарь по информатике Э. Якубайтиса]
    [ http://www.morepc.ru/dict/]

    набор данных
    НД
    -
    [ ГОСТ Р МЭК 61850-7-2-2009]

      НАБОР ДАННЫХ (НД)

    НД представляет собой набор ссылок на данные внутри информационной модели устройства. В НД могут быть включены как отдельные атрибуты данных (например, запись PTOC1.Str.general будет соответствовать одному логическому сигналу пуска защиты), так и логические узлы целиком (например PTOC1). Устройства могут поддерживать различное количество наборов данных. Кроме того, устройства могут иметь фиксированные (то есть когда набор данных нельзя изменить) либо конфигурируемые наборы данных. Также возможны различные степени свободы конфигурации наборов данных: изменение данных, изменение наименования и т.п. Использование наборов данных проиллюстрировано на рис. 3. При рассмотрении контроллера присоединения, на который заведены сигналы о положении всех разъединителей и заземлителей рассматриваемого присоединения, в устройстве должны присутствовать логические узлы, соответствующие каждому из аппаратов (в нашем случае – XSWI1...5). Примером набора данных может служить DATASET с наименованием SwitchPositions, включающий в себя элементы данных Pos каждого из указанных логических узлов. В дальнейшем составленный набор данных может использоваться, например, для сохранения событий в журнале при каждом изменении положения коммутационного аппарата (с использованием сервиса Log), отправки отчета о событии (с использованием сервиса Report) либо быстрого сообщения о событии (с использованием сервиса GOOSE).   Рис. 3. Использование наборов данных  

    При описании информационной модели устройства в нотации МЭК 61850-6 для размещения описаний наборов данных используется системный логический узел LLN0. Наличие логического узла LLN0 является обязательным для каждого логического устройства. При этом не в каждом логическом устройстве могут размещаться наборы данных, поэтому при проектировании и наладке коммуникаций по МЭК 61850 требуется внимательно проверять размещение наборов данных в логических устройствах. Информацию о том, в каком логическом устройстве должны размещаться наборы данных,обычно предоставляет производитель в сопроводительной документации. Подробнее информация об этом будет рассмотрена в будущих публикациях, затрагивающих язык конфигурирования SCL, описанный шестой главой стандарта.

    [ http://www.news.elteh.ru/arh/2012/77/04.php]

    Тематики

    EN

     

    пароохладитель

    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    Тематики

    • электротехника, основные понятия

    EN

     

    пораженная секунда
    (МСЭ-T G.705).
    [ http://www.iks-media.ru/glossary/index.html?glossid=2400324]

    Тематики

    • электросвязь, основные понятия

    EN

     

    проектный стандарт
    Проектный стандарт еще не определен окончательно, но уже опубликован. Проектные стандарты CiA неизменны в течение одного года.
    [ http://can-cia.com/fileadmin/cia/pdfs/CANdictionary-v2_ru.pdf]

    Тематики

    EN

     

    прямая последовательность
    Метод расширения спектра при передаче сигнала, основанный на умножении информационной последовательности на опорный псевдослучайный сигнал с заведомо известными свойствами. При приеме полезная информация выделяется из сигнала известной структуры с помощью алгоритмов свертки.
    [Л.М.Невдяев. Мобильная связь 3-го поколения. Москва, 2000 г.]

    Тематики

    EN

     

    разъединитель
    Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
    Примечание.
    1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
    Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.

    0043 Условное обозначение контакта разъединителя

    [ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]

    разъединитель
    Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
    Примечания
    1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
    2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
    3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
    4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
    [ ГОСТ Р 52726-2007]

    EN

    disconnector
    a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
    NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
    [IEV number 441-14-05]

    disconnector

    IEV 441-14-05 is applicable with the following additional notes:
    NOTE 1
    "Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
    "No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
    NOTE 2
    For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
    [IEC 62271-102]

    FR

    sectionneur
    appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
    NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
    [IEV number 441-14-05]

    Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:

    • изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
    • иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
    • быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
    • обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;

    [ ГОСТ Р МЭК 60204-1-2007]


    Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
    Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
    Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
    Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:

    1. Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
    2. Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
    3. Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
    4. Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
    5. Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
    6. Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.

    [ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]


    Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
    [ http://relay-protection.ru/content/view/46/8/1/1/]


    Параллельные тексты EN-RU

    b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
    [IEC 60204-1-2006]

    б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
    [Перевод Интент]

    Тематики

    • высоковольтный аппарат, оборудование...
    • релейная защита
    • электротехника, основные понятия

    Классификация

    >>>

    EN

    DE

    FR

    Смотри также

     

    распределенное тестирование на одном уровне
    Абстрактный метод тестирования, при котором верхний тестер располагается в тестируемой системе, а точка наблюдения и контроля (PCO) находится на верхней границе сервиса (IUT) для тестирования на одном из уровней протокола. Тестовые события описываются в терминах абстрактных примитивов сервиса (ASP) на верхнем уровне над IUT и ASP и/или PDU для нижнего тестера PCO. 
    [ http://www.lexikon.ru/dict/net/index.html]

    Тематики

    EN

     

    расширение спектра по методу прямой последовательности
    Метод формирования широкополосного сигнала, при котором исходный двоичный сигнал преобразуется в псевдослучайную последовательность для манипуляции несущей. В эфир передается шумоподобный сигнал, обладающий всеми свойствами аддитивного белого шума. Расширение спектра сигнала в n раз с использованием DSSS позволяет уменьшить спектральную плотность мощности сигнала во столько же раз (МСЭ-R SM.1055).
    [ http://www.iks-media.ru/glossary/index.html?glossid=2400324]

    Тематики

    • электросвязь, основные понятия

    EN

     

    цифровой стабилизатор

    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    Тематики

    • электротехника, основные понятия

    EN

    Англо-русский словарь нормативно-технической терминологии > DS

  • 73 distribution

    1. распределительное устройство
    2. распределительная сеть
    3. распределение характеристики
    4. распределение (в биотехнологии)
    5. внедрение (в практику)

     

    внедрение
    1. Процесс планомерного перевода объекта (предприятия или организации, системы управления, отдельного процесса или его элемента) из существующего состояния в новое, предусмотренное проектом.
    2. Распространение нововведений, достижение практического использования прогрессивных идей, изобретений, результатов научных исследований.
    [ http://www.lexikon.ru/dict/buh/index.html]

    Тематики

    EN

     

    распределительная сеть
    Часть энергетической системы, которая предназначена для распределения электроэнергии и работает, как правило, на напряжении до 110 кВ.
    [ ГОСТ Р 54325-2011 (IEC/TS 61850-2:2003)]

    Тематики

    EN

     

    распределительное устройство
    Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [РД 34.20.185-94]

    распределительное устройство

    Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
    Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
    [ ГОСТ 24291-90]
    [ ГОСТ Р 53685-2009]

    электрическое распределительное устройство
    распределительное устройство
    Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
    Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
    [ОСТ 45.55-99]

    распределительное устройство
    Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [ПОТ Р М-016-2001]
    [РД 153-34.0-03.150-00]

    устройство распределительное
    Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    EN

    switching substation
    a substation which includes switchgear and usually busbars, but no power transformers
    [IEV number 605-01-02]

    FR

    poste de sectionnement
    poste de coupure

    poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
    [IEV number 605-01-02]

    В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
    На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]


    КЛАССИФИКАЦИЯ

    В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:

    • по назначению:
      • генерирующие,
      • преобразовательно-распределительные,
      • потребительские.

        Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;

     Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласно ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:

    для электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
    для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.

    Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.

    Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.

    Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.

    Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.

    • по способу управления ПС могут быть:
      • только с телесигнализацией,
      • телеуправляемыми с телесигнализацией,
      • с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).


    Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.

    В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.

    В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
     



    Several different classifications of switchgear can be made:

    A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.

    Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.

    [Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
    [ http://en.wikipedia.org/wiki/High_voltage_switchgear]

    Тематики

    Синонимы

    EN

    DE

    FR

    3.1.2.1 распределение характеристики (distribution): Распределение вероятностей наблюдаемой характеристики, описывающее ее вероятностное поведение.

    Примечание 1 - Распределение вероятностей наблюдаемой характеристики может быть представлено, например, в виде ранжированных результатов наблюдений или гистограммы, построенной по результатам наблюдений. Распределение вероятностей позволяет описать все свойства наблюдаемой характеристики за исключением последовательности, в которой получены данные.

    Примечание 2 - Распределение характеристики зависит от преобладающих условий получения данных. Таким образом, для получения достоверной информации о распределении характеристики необходимо установить условия получения данных.

    Примечание 3 - Важно знать вид распределения (нормальное, лог-нормальное и т.п.) до прогнозирования или оценки показателя воспроизводимости процесса, показателей его функционирования (пригодности), индексов или доли несоответствующих единиц продукции.

    [3534-2:2006, пункт 2.5.1]

    Источник: ГОСТ Р ИСО 21747-2010: Статистические методы. Статистики пригодности и воспроизводимости процесса для количественных характеристик качества оригинал документа

    Англо-русский словарь нормативно-технической терминологии > distribution

  • 74 disconnect switch

    1. разъединитель
    2. размыкающий переключатель
    3. выключатель-разъединитель

     

    выключатель-разъединитель
    Выключатель в разомкнутом положении, удовлетворяющий требованиям к разъединителю.
    МЭК 60050(441-14-12).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    EN

    switch-disconnector
    a switch which, in the open position, satisfies the isolating requirements specified for a disconnector
    [IEV number 441-14-12]

    FR

    interrupteur-sectionneur
    interrupteur qui, dans sa position d'ouverture, satisfait aux conditions d'isolement spécifiées pour un sectionneur
    [IEV number 441-14-12]

    004

    Тематики

    • аппарат, изделие, устройство...

    EN

    DE

    FR

     

    размыкающий переключатель

    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    Тематики

    • электротехника, основные понятия

    EN

     

    разъединитель
    Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
    Примечание.
    1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
    Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.

    0043 Условное обозначение контакта разъединителя

    [ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]

    разъединитель
    Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
    Примечания
    1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
    2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
    3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
    4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
    [ ГОСТ Р 52726-2007]

    EN

    disconnector
    a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
    NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
    [IEV number 441-14-05]

    disconnector

    IEV 441-14-05 is applicable with the following additional notes:
    NOTE 1
    "Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
    "No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
    NOTE 2
    For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
    [IEC 62271-102]

    FR

    sectionneur
    appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
    NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
    [IEV number 441-14-05]

    Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:

    • изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
    • иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
    • быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
    • обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;

    [ ГОСТ Р МЭК 60204-1-2007]


    Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
    Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
    Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
    Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:

    1. Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
    2. Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
    3. Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
    4. Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
    5. Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
    6. Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.

    [ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]


    Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
    [ http://relay-protection.ru/content/view/46/8/1/1/]


    Параллельные тексты EN-RU

    b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
    [IEC 60204-1-2006]

    б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
    [Перевод Интент]

    Тематики

    • высоковольтный аппарат, оборудование...
    • релейная защита
    • электротехника, основные понятия

    Классификация

    >>>

    EN

    DE

    FR

    Смотри также

    Англо-русский словарь нормативно-технической терминологии > disconnect switch

  • 75 isolating switch

    1. разъединитель
    2. выключатель-разъединитель

     

    выключатель-разъединитель
    Выключатель в разомкнутом положении, удовлетворяющий требованиям к разъединителю.
    МЭК 60050(441-14-12).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    EN

    switch-disconnector
    a switch which, in the open position, satisfies the isolating requirements specified for a disconnector
    [IEV number 441-14-12]

    FR

    interrupteur-sectionneur
    interrupteur qui, dans sa position d'ouverture, satisfait aux conditions d'isolement spécifiées pour un sectionneur
    [IEV number 441-14-12]

    004

    Тематики

    • аппарат, изделие, устройство...

    EN

    DE

    FR

     

    разъединитель
    Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
    Примечание.
    1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
    Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.

    0043 Условное обозначение контакта разъединителя

    [ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]

    разъединитель
    Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
    Примечания
    1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
    2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
    3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
    4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
    [ ГОСТ Р 52726-2007]

    EN

    disconnector
    a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
    NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
    [IEV number 441-14-05]

    disconnector

    IEV 441-14-05 is applicable with the following additional notes:
    NOTE 1
    "Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
    "No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
    NOTE 2
    For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
    [IEC 62271-102]

    FR

    sectionneur
    appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
    NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
    [IEV number 441-14-05]

    Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:

    • изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
    • иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
    • быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
    • обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;

    [ ГОСТ Р МЭК 60204-1-2007]


    Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
    Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
    Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
    Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:

    1. Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
    2. Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
    3. Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
    4. Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
    5. Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
    6. Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.

    [ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]


    Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
    [ http://relay-protection.ru/content/view/46/8/1/1/]


    Параллельные тексты EN-RU

    b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
    [IEC 60204-1-2006]

    б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
    [Перевод Интент]

    Тематики

    • высоковольтный аппарат, оборудование...
    • релейная защита
    • электротехника, основные понятия

    Классификация

    >>>

    EN

    DE

    FR

    Смотри также

    Англо-русский словарь нормативно-технической терминологии > isolating switch

  • 76 disconnect

    1. разъединить
    2. разъединитель
    3. отключение абонента
    4. отключать от сети
    5. выключать

     

    выключать

    [А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]

    Тематики

    EN

     

    отключать от сети
    -
    [Интент]

    Электродвигатель должен быть немедленно (аварийно) отключен от сети в следующих случаях:...
    [Правила эксплуатации электроустановок потребителей]

    Коммутационные аппараты в цепях электродвигателей должны отключать от сети одновременно все проводники, находящиеся под напряжением.
    [ПУЭ]

    Тематики

    EN

     

    отключение абонента
    Процедура интерфейса, выполняющаяся при сбросе исполнителем сигналов управления занятостью линий и шин интерфейса.
    [ ГОСТ Р 50304-92 ]

    Тематики

    • системы для сопряж. радиоэлектр. средств интерфейсные

    Обобщающие термины

    EN

     

    разъединитель
    Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
    Примечание.
    1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
    Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.

    0043 Условное обозначение контакта разъединителя

    [ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]

    разъединитель
    Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
    Примечания
    1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
    2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
    3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
    4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
    [ ГОСТ Р 52726-2007]

    EN

    disconnector
    a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
    NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
    [IEV number 441-14-05]

    disconnector

    IEV 441-14-05 is applicable with the following additional notes:
    NOTE 1
    "Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
    "No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
    NOTE 2
    For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
    [IEC 62271-102]

    FR

    sectionneur
    appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
    NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
    [IEV number 441-14-05]

    Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:

    • изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
    • иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
    • быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
    • обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;

    [ ГОСТ Р МЭК 60204-1-2007]


    Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
    Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
    Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
    Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:

    1. Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
    2. Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
    3. Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
    4. Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
    5. Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
    6. Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.

    [ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]


    Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
    [ http://relay-protection.ru/content/view/46/8/1/1/]


    Параллельные тексты EN-RU

    b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
    [IEC 60204-1-2006]

    б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
    [Перевод Интент]

    Тематики

    • высоковольтный аппарат, оборудование...
    • релейная защита
    • электротехника, основные понятия

    Классификация

    >>>

    EN

    DE

    FR

    Смотри также

     

    разъединить

    [ http://www.iks-media.ru/glossary/index.html?glossid=2400324]

    Тематики

    • электросвязь, основные понятия

    EN

    Англо-русский словарь нормативно-технической терминологии > disconnect

  • 77 panel

    1. филенка
    2. подкомиссия
    3. плата (с монтажом)
    4. панель (элемент здания)
    5. НКУ распределения и управления
    6. монтажная панель
    7. заготовка печатной платы

     

    заготовка печатной платы
    заготовка

    Материал основания печатной платы определенного размера, который подвергается обработке на всех производственных операциях.
    [ ГОСТ 20406-75]

    заготовка печатной платы
    Базовый материал печатной платы определенного размера, подвергаемый обработке в процессе изготовления печатной платы.
    [ ГОСТ Р 53386-2009]

    Тематики

    Синонимы

    EN

    FR

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

     

    панель
    Крупный элемент сборных конструкций в виде пластинки, размеры которого соответствуют основным объёмно-планировочным членениям сооружения
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    Тематики

    EN

    DE

    FR

     

    плата (с монтажом)

    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    Тематики

    • электротехника, основные понятия

    EN

     

    подкомиссия
    группа экспертов
    специальный комитет (комиссия)


    [ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]

    Тематики

    Синонимы

    EN

     

    филенка
    Выделенный тонкими профилированными рамками участок, щиток из тонких досок, фанеры или пластика, закрывающий просвет в каркасе полотна двери
    [ http://na-dveri.ru/polezno-znati/termini-i-opredeleniya.html]

    Тематики

    EN

     

    монтажная панель
    Панель, служащая для размещения комплектующих элементов и предназначенная для установки в НКУ.
    Примечание - Если этот конструктивный элемент содержит аппаратуру, то он может рассматриваться как отдельное самостоятельное НКУ.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    монтажная панель
    Панель, предназначенная для размещения комплектующих элементов, устанавливаемая в НКУ
    [ ГОСТ Р МЭК 61439.1-2013]

    монтажная панель
    Отдельный внутренний комплектующий элемент оболочки, предназначенный для установки и крепления на нем аппаратуры распределения и управления.
    [ ГОСТ Р 52796- 2007( МЭК 62208: 2002)]

    EN

    mounting plate
    separate internal accessory of the enclosure intended for the mounting of electrical components
    [IEC 62208, ed. 1.0 (2002-11)]

    FR

    platine
    élément interne séparé de l'enveloppe destiné au montage de l'appareillage
    [IEC 62208, ed. 1.0 (2002-11)]

    0093

    0094

    Установка неперфорированной монтажной панели в оболочку шкафа

    Неразборная сварная оболочка ящика с установленной перфорированной оцинкованной монтажной панелью

    На предприятии, выполняющем электромонтаж НКУ, монтажную панель обычно извлекают из оболочки, выполняют электромонтаж, а затем монтажную панель с установленными аппаратами и выполненным электромонтажом вставляют в оболочку.
    [Интент]


     

    Недопустимые, нерекомендуемые

    Тематики

    • НКУ (шкафы, пульты,...)

    Обобщающие термины

    EN

    FR

    Англо-русский словарь нормативно-технической терминологии > panel

  • 78 electrical switchboard

    1. НКУ распределения и управления

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

    Англо-русский словарь нормативно-технической терминологии > electrical switchboard

  • 79 low voltage switchboard

    1. НКУ распределения и управления

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

    Англо-русский словарь нормативно-технической терминологии > low voltage switchboard

  • 80 LV switchgear assembly

    1. НКУ распределения и управления

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

    Англо-русский словарь нормативно-технической терминологии > LV switchgear assembly

См. также в других словарях:

  • NOT-AND circuit — loginis IR NE grandynas statusas T sritis radioelektronika atitikmenys: angl. NAND circuit; NOT AND circuit vok. logische NAND Schaltung, f rus. логическая схема И НЕ, f pranc. circuit ET NON, m …   Radioelektronikos terminų žodynas

  • circuit ET-NON — loginis IR NE grandynas statusas T sritis radioelektronika atitikmenys: angl. NAND circuit; NOT AND circuit vok. logische NAND Schaltung, f rus. логическая схема И НЕ, f pranc. circuit ET NON, m …   Radioelektronikos terminų žodynas

  • Circuit total limitation — (CTL) is one of the present day standards for electrical panels sold in the United States according to the National Electrical Code. The 1965 edition of the NEC, article 384 15 was the first reference to the circuit total limitation of… …   Wikipedia

  • Circuit of the Americas — Location Travis County, near Austin, Texas Time zone UTC 6 (standard) / 5 (DST) Coordinates …   Wikipedia

  • Circuit City Stores — This article is about the defunct company that operated from 1949 to 2009. For the online retailer owned by Systemax, see CircuitCity.com. Circuit City Stores, Inc. The final 2001 2009 logo Former type Public …   Wikipedia

  • Circuit rider (religious) — This page refers to a position within the Methodist Church. For other uses, see Circuit rider (disambiguation). Illustration from The Circuit Rider: A Tale of the Heroic Age by Edward Eggleston depicting a Methodist circuit rider on horseback.… …   Wikipedia

  • Circuit City Stores, Inc. v. Adams — Circuit City Stores, Inc. v. Adams …   Wikipedia

  • Circuit bending — Probing for bends using a jeweler s screwdriver and alligator clips Circuit bending is the creative customization of the circuits within electronic devices such as low voltage, battery powered guitar effects, children s toys and small digital… …   Wikipedia

  • Circuit integrity — fireproofing of cable trays in Lingen/Ems, Germany using calcium silicate board system qualified to DIN 4102 …   Wikipedia

  • Circuit Park Zandvoort — Zandvoort today Location Burgemeester van Alphenstraat 108, 2041 KP Zandvoort, Netherlands Time zone CET (UTC+01) Major events …   Wikipedia

  • Circuit switching — is a methodology of implementing a telecommunications network in which two network nodes establish a dedicated communications channel (circuit) through the network before the nodes may communicate. The circuit guarantees the full bandwidth of the …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»