121 level
1) уровень2) тлв. совокупность параметров изображения или их комбинаций3) степень4) порог5) регулировка•- acceptance-quality level
- acoustic noise level
- adaptation level
- addressing level
- alpha-geometric level
- alphamosaic level
- ambient level
- ambient-noise level
- amplitude levels
- audio-signal output level
- automatic white level
- average picture level
- band-power level
- band-pressure level
- base level
- black level
- blanking level
- call-tone level
- carrier-noise level
- channel level
- channel switching level
- channel-noise level
- chromatic level
- circuit-noise level
- coding level
- controlled level
- C-scale sound level
- current sensitivity level
- damage level
- data link level
- datum level
- defined level
- detail level
- digitization level
- effective recombination level
- electromagnetic interference level
- energy saving level
- foreground level
- frequency-modulated noise level on carrier
- hearing level
- HF-signal level
- hierarchical levels
- high level
- higher-order hierarchical level
- illuminance level
- input signal level
- integration level
- interference level
- internal sound level
- interrupt level
- link level
- load compensating level
- load compensation level
- logical 0 low level
- logical 1 high level
- loudness level
- lower order hierarchical level
- main level
- maximum acceptable signal level
- maximum record level
- maximum signal level
- measuring transmission level
- metallic level
- minimum-signal level
- noise level
- noise-emission level
- noise-generation level
- nondistorted peak level
- operating level
- optical recording level
- output signal level
- overload level
- peak level
- pedestal level
- pressure spectrum level
- printthrough level
- priority level
- privilege level
- protective level
- quantization level
- rated transmission level
- receiver overload level
- reference-black level
- reference-white level
- regenerator section level
- relative-signal level
- relative-transmission level
- representation level
- restriction level level
- rumble level
- side-lobe level
- sidetone level
- signal level
- sound intensity level
- sound level
- sound pressure level
- source sound level
- spectral voice level
- spectrum level
- speech interference level
- speech level
- SSB-equipment reference level
- susceptibility level
- sync level
- synchronous level
- telephone-network computerization level
- television level
- testing level
- through level
- transmission level
- transmission-path level
- trigger level
- virtual channel level
- virtual path level
- zero level
- zero-transmission levelEnglish-Russian dictionary of telecommunications and their abbreviations > level
-
122 U/I characteristic
внешняя характеристика (источника электропитания)
-
Рис. ABB
Rectangular current limiting
Рис. ABB
Triangular current limitingPower supplies with a U/I characteristic perform current limiting to typically 1.1 to 1.2 times the rated current at constant output voltage. This current is still available in case of an overload or a short circuit. In this case, the power supply either immediately cuts the output voltage to zero (rectangular current limiting) or performs slow lowering of the output voltage, what, however, can possibly lead to a further increase of the output current (triangular current limiting).
Since the current does not sag in case of an overload, this method enables reliable starting of high loads.
[ABB]Тематики
EN
- U/I characteristic
Англо-русский словарь нормативно-технической терминологии > U/I characteristic
-
123 co-ordination
- координация (контакторов и пускателей) с устройствами защиты от короткого замыкания
координация (контакторов и пускателей) с устройствами защиты от короткого замыкания
-7.2.5 Координация с аппаратами защиты от коротких замыканий
7.2.5.1 Работоспособность в условиях короткого замыкания (номинальный условный ток короткого замыкания)
... Допускается координация двух типов — 1 или 2....
Координация типа 1 требует, чтобы в условиях короткого замыкания контактор или пускатель не создавали опасности для людей или оборудования, хотя они могут оказаться непригодными для дальнейшей эксплуатации без ремонта и замены частей.
Координация типа 2 требует, чтобы в условиях короткого замыкания контактор или пускатель не создавали опасности для людей или оборудования и оставались пригодными для дальнейшей эксплуатации. Возможность сваривания контактов допускается, и в этом случае изготовитель должен рекомендовать меры по обслуживанию аппаратов.
[ ГОСТ Р 50030.4.1-2002 (МЭК 60947-4-1-2000)]Параллельные тексты EN-RU
Co-ordination type 1 and type 2
The co-ordination typologies admitted by the Standard with reference to the behavior of the protection device against short-circuit towards the starter components are classified as “type 1” and “type 2”.
Under short-circuit conditions, the coordination of type “1” allows the contactor and the overload relay to be damaged; as a consequence they could not be able to operate without repairing or replacement of parts.
However, the Standard prescribes that these devices do not cause damages to people or installations, for example with parts of the components ejected outside the enclosure.
Under short-circuit conditions, the coordination of type “2” allows the risk of contact welding, provided that the contacts themselves can be easily separated (for example through a screwdriver) without important deformations.
This type of coordination requires that the contactor or the starter do not cause damages to people or installation and that they are able to resume operation after restoring of the standard conditions.
From the definition of the two coordination typologies it is possible to deduce how “type 1” coordination permits the use of devices of lower sizes, thus with an initial cost saving and reduced dimensions, but to the disadvantage of a high safety and however with subsequent costs for maintenance and replacement in case of faults.
“Type 2” coordination meets higher safety requirements and the possible greater initial cost can be amortized considering that, in case of fault, the switching and protection equipment could start operating again without being replaced.
[ABB]Координация типа 1 и 2 с аппаратами защиты от коротких замыканий
Стандарт определяет два типа координации компонентов пускателя с аппаратами защиты от короткого замыкания: тип 1 и тип 2.
Координация типа 1. В условиях короткого замыкания допускается повреждение контактора и теплового реле, в результате чего они могут оказаться непригодными для дальнейшей эксплуатации без ремонта и замены частей. При этом данные устройства не должны создавать опасности для людей и оборудования, например, вследствие вылета частей пускателя из оболочки.
Координация типа 2. В условиях короткого замыкания допускает сваривание контактов при условии, что они могут быть легко разъединены (например, отверткой) без заметной деформации. Контактор и тепловое реле не должны создавать опасности для людей и оборудования и должны оставаться пригодными для дальнейшей эксплуатации после восстановления нормальных условий.
Из определения двух типов координации можно сделать вывод, что координация типа 1 позволяет использовать устройства, рассчитанные на меньшие рабочие токи, обеспечивая таким образом экономию на первоначальных затратах и сокращение размеров устройств, но снижая при этом уровень безопасности и приводя впоследствии к расходам на техническое обслуживание и замену в случае возникновения неисправности.
Координация типа 2 отвечает более высоким требованиям безопасности и имеет большие первоначальные расходы, которые могут быть компенсированы тем, что в случае возникновения неисправности эксплуатация коммутационных и защитных аппаратов может быть продолжена без замены их частей.
[Перевод Интент]Тематики
EN
Англо-русский словарь нормативно-технической терминологии > co-ordination
-
124 co-ordination type 2
- координация типа 2 (пускателя) с устройством защиты от короткого замыкания
координация типа 2 (пускателя) с устройством защиты от короткого замыкания
-Параллельные тексты EN-RU
Co-ordination type 1 and type 2
The co-ordination typologies admitted by the Standard with reference to the behavior of the protection device against short-circuit towards the starter components are classified as “type 1” and “type 2”.
Under short-circuit conditions, the coordination of type “1” allows the contactor and the overload relay to be damaged; as a consequence they could not be able to operate without repairing or replacement of parts. However, the Standard prescribes that these devices do not cause damages to people or installations, for example with parts of the components ejected outside the enclosure.
Under short-circuit conditions, the coordination of type “2” allows the risk of contact welding, provided that the contacts themselves can be easily separated (for example through a screwdriver) without important deformations.
This type of coordination requires that the contactor or the starter do not cause damages to people or installation and that they are able to resume operation after restoring of the standard conditions.
[ABB]Координация типа 1 и 2 с аппаратом защиты от короткого замыкания
Стандарт определяет два типа координации компонентов пускателя с аппаратами защиты от короткого замыкания: тип 1 и тип 2.
Координация типа 1. В условиях короткого замыкания допускается повреждение контактора и теплового реле, в результате чего они могут оказаться непригодными для дальнейшей эксплуатации без ремонта и замены частей. При этом данные устройства не должны создавать опасности для людей и оборудования, например, вследствие вылета частей пускателя из оболочки.
Координация типа 2. В условиях короткого замыкания допускает сваривание контактов при условии, что они могут быть легко разъединены (например, отверткой) без заметной деформации. Контактор или пускатель не должны создавать опасности для людей и оборудования и должны оставаться пригодными для дальнейшей эксплуатации после восстановления нормальных условий.
[Перевод Интент]Тематики
EN
Англо-русский словарь нормативно-технической терминологии > co-ordination type 2
-
125 coordination of type 2
- координация типа 2 (пускателя) с устройством защиты от короткого замыкания
координация типа 2 (пускателя) с устройством защиты от короткого замыкания
-Параллельные тексты EN-RU
Co-ordination type 1 and type 2
The co-ordination typologies admitted by the Standard with reference to the behavior of the protection device against short-circuit towards the starter components are classified as “type 1” and “type 2”.
Under short-circuit conditions, the coordination of type “1” allows the contactor and the overload relay to be damaged; as a consequence they could not be able to operate without repairing or replacement of parts. However, the Standard prescribes that these devices do not cause damages to people or installations, for example with parts of the components ejected outside the enclosure.
Under short-circuit conditions, the coordination of type “2” allows the risk of contact welding, provided that the contacts themselves can be easily separated (for example through a screwdriver) without important deformations.
This type of coordination requires that the contactor or the starter do not cause damages to people or installation and that they are able to resume operation after restoring of the standard conditions.
[ABB]Координация типа 1 и 2 с аппаратом защиты от короткого замыкания
Стандарт определяет два типа координации компонентов пускателя с аппаратами защиты от короткого замыкания: тип 1 и тип 2.
Координация типа 1. В условиях короткого замыкания допускается повреждение контактора и теплового реле, в результате чего они могут оказаться непригодными для дальнейшей эксплуатации без ремонта и замены частей. При этом данные устройства не должны создавать опасности для людей и оборудования, например, вследствие вылета частей пускателя из оболочки.
Координация типа 2. В условиях короткого замыкания допускает сваривание контактов при условии, что они могут быть легко разъединены (например, отверткой) без заметной деформации. Контактор или пускатель не должны создавать опасности для людей и оборудования и должны оставаться пригодными для дальнейшей эксплуатации после восстановления нормальных условий.
[Перевод Интент]Тематики
EN
Англо-русский словарь нормативно-технической терминологии > coordination of type 2
-
126 coordination type 2
- координация типа 2 (пускателя) с устройством защиты от короткого замыкания
координация типа 2 (пускателя) с устройством защиты от короткого замыкания
-Параллельные тексты EN-RU
Co-ordination type 1 and type 2
The co-ordination typologies admitted by the Standard with reference to the behavior of the protection device against short-circuit towards the starter components are classified as “type 1” and “type 2”.
Under short-circuit conditions, the coordination of type “1” allows the contactor and the overload relay to be damaged; as a consequence they could not be able to operate without repairing or replacement of parts. However, the Standard prescribes that these devices do not cause damages to people or installations, for example with parts of the components ejected outside the enclosure.
Under short-circuit conditions, the coordination of type “2” allows the risk of contact welding, provided that the contacts themselves can be easily separated (for example through a screwdriver) without important deformations.
This type of coordination requires that the contactor or the starter do not cause damages to people or installation and that they are able to resume operation after restoring of the standard conditions.
[ABB]Координация типа 1 и 2 с аппаратом защиты от короткого замыкания
Стандарт определяет два типа координации компонентов пускателя с аппаратами защиты от короткого замыкания: тип 1 и тип 2.
Координация типа 1. В условиях короткого замыкания допускается повреждение контактора и теплового реле, в результате чего они могут оказаться непригодными для дальнейшей эксплуатации без ремонта и замены частей. При этом данные устройства не должны создавать опасности для людей и оборудования, например, вследствие вылета частей пускателя из оболочки.
Координация типа 2. В условиях короткого замыкания допускает сваривание контактов при условии, что они могут быть легко разъединены (например, отверткой) без заметной деформации. Контактор или пускатель не должны создавать опасности для людей и оборудования и должны оставаться пригодными для дальнейшей эксплуатации после восстановления нормальных условий.
[Перевод Интент]Тематики
EN
Англо-русский словарь нормативно-технической терминологии > coordination type 2
-
127 type 2 coordination
- координация типа 2 (пускателя) с устройством защиты от короткого замыкания
координация типа 2 (пускателя) с устройством защиты от короткого замыкания
-Параллельные тексты EN-RU
Co-ordination type 1 and type 2
The co-ordination typologies admitted by the Standard with reference to the behavior of the protection device against short-circuit towards the starter components are classified as “type 1” and “type 2”.
Under short-circuit conditions, the coordination of type “1” allows the contactor and the overload relay to be damaged; as a consequence they could not be able to operate without repairing or replacement of parts. However, the Standard prescribes that these devices do not cause damages to people or installations, for example with parts of the components ejected outside the enclosure.
Under short-circuit conditions, the coordination of type “2” allows the risk of contact welding, provided that the contacts themselves can be easily separated (for example through a screwdriver) without important deformations.
This type of coordination requires that the contactor or the starter do not cause damages to people or installation and that they are able to resume operation after restoring of the standard conditions.
[ABB]Координация типа 1 и 2 с аппаратом защиты от короткого замыкания
Стандарт определяет два типа координации компонентов пускателя с аппаратами защиты от короткого замыкания: тип 1 и тип 2.
Координация типа 1. В условиях короткого замыкания допускается повреждение контактора и теплового реле, в результате чего они могут оказаться непригодными для дальнейшей эксплуатации без ремонта и замены частей. При этом данные устройства не должны создавать опасности для людей и оборудования, например, вследствие вылета частей пускателя из оболочки.
Координация типа 2. В условиях короткого замыкания допускает сваривание контактов при условии, что они могут быть легко разъединены (например, отверткой) без заметной деформации. Контактор или пускатель не должны создавать опасности для людей и оборудования и должны оставаться пригодными для дальнейшей эксплуатации после восстановления нормальных условий.
[Перевод Интент]Тематики
EN
Англо-русский словарь нормативно-технической терминологии > type 2 coordination
-
128 overfreight
ˈəuvəˈfreɪt = overload перегрузка перегружать, нагружать сверх меры - to * a boat перегрузить лодку (техническое) форсировать (режим работы) ;
перегружать - to * an electric circuit перегружать электросеть - to * an electric circuit перегружать электросеть overfreight = oberload overfreight = oberloadБольшой англо-русский и русско-английский словарь > overfreight
См. также в других словарях:
Circuit training — is a form of conditioning combining resistance training and high intensity aerobics. It is designed to be easy to follow and target strength building as well as muscular endurance. An exercise circuit is one completion of all prescribed exercises … Wikipedia
circuit breaker — circuit breakers also circuit breaker N COUNT A circuit breaker is a device which can stop the flow of electricity around a circuit by switching itself off if anything goes wrong. There is an internal circuit breaker to protect the instrument… … English dictionary
Circuit breaker — For other uses, see Circuit breaker (disambiguation). An air circuit breaker for low voltage (less than 1000 volts) power distribution switchgear … Wikipedia
Overload (Pakistani band) — This article is about the band. For the band s self titled album, see Overload (Overload album). Overload Overload perform in a concert in Carlton Hotel, Karachi. Background information … Wikipedia
overload — o|ver|load [ˌəuvəˈləud US ˌouvərˈloud] v past participle overloaded or overladen [ ˈleıdn] [T] 1.) to put too many things or people on or into something ▪ Be careful not to overload the washing machine. be/become overloaded with sth ▪ The bus was … Dictionary of contemporary English
circuit — noun 1 path for an electric current ADJECTIVE ▪ short ▪ The lights were not working because of a short circuit. ▪ closed ▪ integrated, printed ▪ … Collocations dictionary
overload — {{Roman}}I.{{/Roman}} noun Overload is used after these nouns: ↑information {{Roman}}II.{{/Roman}} verb PREPOSITION ▪ with ▪ Their staff are heavily overloaded with work. PHRASES ▪ … Collocations dictionary
overload — 1. verb a) to load excessively b) to provide too much power to a circuit 2. noun a) An excessive load. Code an overload of the insertion operator for the Rectangle class … Wiktionary
circuit breaker — A device that takes the place of a fixed fuse in an electrical circuit. In the event of an overload, the circuit breaker “pops out” it can be reset by pushing it in. Normally referred to by its short form, CB … Aviation dictionary
Circuit Breaker — A device used to interrupt or break an electrical circuit when an overload condition exists; usually installed in the positive circuit; used to protect electrical equipment … Energy terms
Short circuit — A short circuit (sometimes abbreviated to short or s/c) allows a current along a different path from the one intended. The electrical opposite of a short circuit is an open circuit , which is an infinite resistance between two nodes. It is common … Wikipedia