1 load break cut-out
-
2 disconnecting switch
English-german engineering dictionary > disconnecting switch
-
3 load break interrupter switch
English-german engineering dictionary > load break interrupter switch
-
4 load break non-fused interrupter switch
English-german engineering dictionary > load break non-fused interrupter switch
-
5 load break switch
load break switch ELEK Lastabschalter m, Lasttrenner m, Lasttrennschalter m, Leistungstrennschalter m -
6 load disconnecting switch
English-german engineering dictionary > load disconnecting switch
-
7 load break switch
English-German dictionary of Electrical Engineering and Electronics > load break switch
-
8 load-interrupter switch
load-interrupter switch Lasttrennschalter mEnglish-German dictionary of Electrical Engineering and Electronics > load-interrupter switch
-
9 switch disconnector
English-German dictionary of Electrical Engineering and Electronics > switch disconnector
-
10 SDF
- функция передачи данных службы
- топливо, полученное из твёрдых отходов
- синхронный поток данных
- расчётное затопление активной зоны ядерного реактора в результате водосброса
- кратковременный отказ (оборудования)
- выключатель-разъединитель-предохранитель
- аппаратное обеспечение диагностической системы
аппаратное обеспечение диагностической системы
—
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
выключатель-разъединитель-предохранитель
Выключатель-разъединитель, у которого один или несколько полюсов имеют последовательно соединенный плавкий предохранитель и образуют с ним единое устройство.
(МЭС 441-14-16)
[ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]EN
switch-disconnector-fuse
switch-disconnector in which one or more poles have a fuse in series in a composite unit.
[IEV number 441-14-16]FR
linterrupteur-sectionneur à fusibles
interrupteur-sectionneur dans lequel un ou plusieurs pôles comportent un fusible en série dans un appareil combiné
[IEV number 441-14-16]Тематики
- аппарат, изделие, устройство...
Обобщающие термины
EN
- SDF
- switch disconnector and fuse unit
- switch disconnector fuses
- switch-disconnector fuse
- switch-disconnector-fuse
- switch-disconnector-fuses
DE
FR
кратковременный отказ (оборудования)
—
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
расчётное затопление активной зоны ядерного реактора в результате водосброса
—
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
синхронный поток данных
—
[Е.С.Алексеев, А.А.Мячев. Англо-русский толковый словарь по системотехнике ЭВМ. Москва 1993]Тематики
EN
топливо, полученное из твёрдых отходов
—
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
функция передачи данных службы
—
[Л.Г.Суменко. Англо-русский словарь по информационным технологиям. М.: ГП ЦНИИС, 2003.]Тематики
EN
Англо-русский словарь нормативно-технической терминологии > SDF
-
11 disconnect switch
выключатель-разъединитель
Выключатель в разомкнутом положении, удовлетворяющий требованиям к разъединителю.
МЭК 60050(441-14-12).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
switch-disconnector
a switch which, in the open position, satisfies the isolating requirements specified for a disconnector
[IEV number 441-14-12]FR
interrupteur-sectionneur
interrupteur qui, dans sa position d'ouverture, satisfait aux conditions d'isolement spécifiées pour un sectionneur
[IEV number 441-14-12]Тематики
- аппарат, изделие, устройство...
EN
DE
FR
размыкающий переключатель
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
разъединитель
Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
Примечание.
1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.
Условное обозначение контакта разъединителя
[ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]
разъединитель
Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
Примечания
1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
[ ГОСТ Р 52726-2007]EN
disconnector
a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
[IEV number 441-14-05]
disconnector
IEV 441-14-05 is applicable with the following additional notes:
NOTE 1
"Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
"No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
NOTE 2
For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
[IEC 62271-102]FR
sectionneur
appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
[IEV number 441-14-05]Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:
- изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
- иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
- быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
- обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;
Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:- Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
- Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
- Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
- Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
- Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
- Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.
[ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]
Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
[ http://relay-protection.ru/content/view/46/8/1/1/]
Параллельные тексты EN-RU
b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
[IEC 60204-1-2006]
б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
[Перевод Интент]
Тематики
- высоковольтный аппарат, оборудование...
- релейная защита
- электротехника, основные понятия
Классификация
>>>EN
- disconnect
- disconnect device
- disconnect switch
- disconnecting device
- disconnecting switch
- disconnector
- DS
- isolating facility
- isolating switch
- isolator
- main disconnect device
DE
FR
Смотри также
Англо-русский словарь нормативно-технической терминологии > disconnect switch
12 isolating switch
выключатель-разъединитель
Выключатель в разомкнутом положении, удовлетворяющий требованиям к разъединителю.
МЭК 60050(441-14-12).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
switch-disconnector
a switch which, in the open position, satisfies the isolating requirements specified for a disconnector
[IEV number 441-14-12]FR
interrupteur-sectionneur
interrupteur qui, dans sa position d'ouverture, satisfait aux conditions d'isolement spécifiées pour un sectionneur
[IEV number 441-14-12]Тематики
- аппарат, изделие, устройство...
EN
DE
FR
разъединитель
Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
Примечание.
1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.
Условное обозначение контакта разъединителя
[ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]
разъединитель
Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
Примечания
1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
[ ГОСТ Р 52726-2007]EN
disconnector
a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
[IEV number 441-14-05]
disconnector
IEV 441-14-05 is applicable with the following additional notes:
NOTE 1
"Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
"No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
NOTE 2
For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
[IEC 62271-102]FR
sectionneur
appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
[IEV number 441-14-05]Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:
- изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
- иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
- быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
- обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;
Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:- Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
- Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
- Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
- Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
- Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
- Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.
[ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]
Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
[ http://relay-protection.ru/content/view/46/8/1/1/]
Параллельные тексты EN-RU
b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
[IEC 60204-1-2006]
б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
[Перевод Интент]
Тематики
- высоковольтный аппарат, оборудование...
- релейная защита
- электротехника, основные понятия
Классификация
>>>EN
- disconnect
- disconnect device
- disconnect switch
- disconnecting device
- disconnecting switch
- disconnector
- DS
- isolating facility
- isolating switch
- isolator
- main disconnect device
DE
FR
Смотри также
Англо-русский словарь нормативно-технической терминологии > isolating switch
13 switch disconnector
выключатель-разъединитель
Выключатель в разомкнутом положении, удовлетворяющий требованиям к разъединителю.
МЭК 60050(441-14-12).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
switch-disconnector
a switch which, in the open position, satisfies the isolating requirements specified for a disconnector
[IEV number 441-14-12]FR
interrupteur-sectionneur
interrupteur qui, dans sa position d'ouverture, satisfait aux conditions d'isolement spécifiées pour un sectionneur
[IEV number 441-14-12]Тематики
- аппарат, изделие, устройство...
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > switch disconnector
14 switch-disconnector
выключатель-разъединитель
Выключатель в разомкнутом положении, удовлетворяющий требованиям к разъединителю.
МЭК 60050(441-14-12).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
switch-disconnector
a switch which, in the open position, satisfies the isolating requirements specified for a disconnector
[IEV number 441-14-12]FR
interrupteur-sectionneur
interrupteur qui, dans sa position d'ouverture, satisfait aux conditions d'isolement spécifiées pour un sectionneur
[IEV number 441-14-12]Тематики
- аппарат, изделие, устройство...
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > switch-disconnector
15 trip free switch
выключатель-разъединитель
Выключатель в разомкнутом положении, удовлетворяющий требованиям к разъединителю.
МЭК 60050(441-14-12).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
switch-disconnector
a switch which, in the open position, satisfies the isolating requirements specified for a disconnector
[IEV number 441-14-12]FR
interrupteur-sectionneur
interrupteur qui, dans sa position d'ouverture, satisfait aux conditions d'isolement spécifiées pour un sectionneur
[IEV number 441-14-12]Тематики
- аппарат, изделие, устройство...
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > trip free switch
16 switch disconnector and fuse unit
выключатель-разъединитель-предохранитель
Выключатель-разъединитель, у которого один или несколько полюсов имеют последовательно соединенный плавкий предохранитель и образуют с ним единое устройство.
(МЭС 441-14-16)
[ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]EN
switch-disconnector-fuse
switch-disconnector in which one or more poles have a fuse in series in a composite unit.
[IEV number 441-14-16]FR
linterrupteur-sectionneur à fusibles
interrupteur-sectionneur dans lequel un ou plusieurs pôles comportent un fusible en série dans un appareil combiné
[IEV number 441-14-16]Тематики
- аппарат, изделие, устройство...
Обобщающие термины
EN
- SDF
- switch disconnector and fuse unit
- switch disconnector fuses
- switch-disconnector fuse
- switch-disconnector-fuse
- switch-disconnector-fuses
DE
FR
Англо-русский словарь нормативно-технической терминологии > switch disconnector and fuse unit
17 switch disconnector fuses
выключатель-разъединитель-предохранитель
Выключатель-разъединитель, у которого один или несколько полюсов имеют последовательно соединенный плавкий предохранитель и образуют с ним единое устройство.
(МЭС 441-14-16)
[ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]EN
switch-disconnector-fuse
switch-disconnector in which one or more poles have a fuse in series in a composite unit.
[IEV number 441-14-16]FR
linterrupteur-sectionneur à fusibles
interrupteur-sectionneur dans lequel un ou plusieurs pôles comportent un fusible en série dans un appareil combiné
[IEV number 441-14-16]Тематики
- аппарат, изделие, устройство...
Обобщающие термины
EN
- SDF
- switch disconnector and fuse unit
- switch disconnector fuses
- switch-disconnector fuse
- switch-disconnector-fuse
- switch-disconnector-fuses
DE
FR
Англо-русский словарь нормативно-технической терминологии > switch disconnector fuses
18 switch-disconnector fuse
выключатель-разъединитель-предохранитель
Выключатель-разъединитель, у которого один или несколько полюсов имеют последовательно соединенный плавкий предохранитель и образуют с ним единое устройство.
(МЭС 441-14-16)
[ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]EN
switch-disconnector-fuse
switch-disconnector in which one or more poles have a fuse in series in a composite unit.
[IEV number 441-14-16]FR
linterrupteur-sectionneur à fusibles
interrupteur-sectionneur dans lequel un ou plusieurs pôles comportent un fusible en série dans un appareil combiné
[IEV number 441-14-16]Тематики
- аппарат, изделие, устройство...
Обобщающие термины
EN
- SDF
- switch disconnector and fuse unit
- switch disconnector fuses
- switch-disconnector fuse
- switch-disconnector-fuse
- switch-disconnector-fuses
DE
FR
Англо-русский словарь нормативно-технической терминологии > switch-disconnector fuse
19 switch-disconnector-fuse
выключатель-разъединитель-предохранитель
Выключатель-разъединитель, у которого один или несколько полюсов имеют последовательно соединенный плавкий предохранитель и образуют с ним единое устройство.
(МЭС 441-14-16)
[ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]EN
switch-disconnector-fuse
switch-disconnector in which one or more poles have a fuse in series in a composite unit.
[IEV number 441-14-16]FR
linterrupteur-sectionneur à fusibles
interrupteur-sectionneur dans lequel un ou plusieurs pôles comportent un fusible en série dans un appareil combiné
[IEV number 441-14-16]Тематики
- аппарат, изделие, устройство...
Обобщающие термины
EN
- SDF
- switch disconnector and fuse unit
- switch disconnector fuses
- switch-disconnector fuse
- switch-disconnector-fuse
- switch-disconnector-fuses
DE
FR
Англо-русский словарь нормативно-технической терминологии > switch-disconnector-fuse
20 switch-disconnector-fuses
выключатель-разъединитель-предохранитель
Выключатель-разъединитель, у которого один или несколько полюсов имеют последовательно соединенный плавкий предохранитель и образуют с ним единое устройство.
(МЭС 441-14-16)
[ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]EN
switch-disconnector-fuse
switch-disconnector in which one or more poles have a fuse in series in a composite unit.
[IEV number 441-14-16]FR
linterrupteur-sectionneur à fusibles
interrupteur-sectionneur dans lequel un ou plusieurs pôles comportent un fusible en série dans un appareil combiné
[IEV number 441-14-16]Тематики
- аппарат, изделие, устройство...
Обобщающие термины
EN
- SDF
- switch disconnector and fuse unit
- switch disconnector fuses
- switch-disconnector fuse
- switch-disconnector-fuse
- switch-disconnector-fuses
DE
FR
Англо-русский словарь нормативно-технической терминологии > switch-disconnector-fuses
См. также в других словарях:
Lasttrennschalter — Scherentrennschalter („Trenner“) in einer Freiluftschaltanlage für 380 kV Kombination aus Drehtrenn und Erdungstrennschalter in einer Freiluftschal … Deutsch Wikipedia
Hochspannungsschalter — sind elektrische Schalter für Spannungen über 1 kV. Schalter für Spannungen unterhalb von 1 kV werden Niederspannungsschalter genannt. Bei den Hochspannungsschaltern unterscheidet man Leistungsschalter, Lasttrennschalter und Trenner.… … Deutsch Wikipedia
Abschaltstrom — Der Ausschaltstrom oder Abschaltstrom ist der Strom, für den ein Schalter, ein Relais oder ein Schützkontakt, ein Lasttrennschalter oder ein Leistungsschalter beim Abschalten des Stromes spezifiziert sind. Bei Sicherungen (Schmelzsicherungen und… … Deutsch Wikipedia
Bogenentladung — Lichtbogen zwischen zwei Stahlnägeln Ein Lichtbogen ist eine sich selbst erhaltende Gasentladung zwischen zwei Elektroden, die eine ausreichend hohe elektrische Potentialdifferenz (=Spannung) aufweisen, um durch Stoßionisation die benötigte hohe… … Deutsch Wikipedia
DIN-VDE-Normen Teil 1 — Anmerkung: Diese Liste kann keinen Anspruch auf Aktualität erheben. Eine aktuelle Liste dieser Normen kann auf der Website vom VDE Verlag abgerufen werden. Liste der VDE Normen von VDE 0000 bis 0199 VDE 0022 2008 08 Satzung für das… … Deutsch Wikipedia
Feinsicherung — Eine Schmelzsicherung ist eine Überstromschutzeinrichtung, die einen Stromkreis bei zu hoher Stromstärke durch die thermische Wirkung des Stroms unterbricht und dadurch zerstört wird. Da sie im Gegensatz zu vielen anderen Sicherungen nach… … Deutsch Wikipedia
Leistungsschalter — sind spezielle Schalter, die für hohe Ströme ausgelegt sind. Sie können nicht nur Betriebsströme und geringe Überlastströme schalten, sondern auch bei Fehlern hohe Überlastströme und Kurzschlussströme (GLS bis 800 Kiloampere) einschalten, diese… … Deutsch Wikipedia
Liste der Schaltzeichen (Elektrik/Elektronik) — In diesem Artikel oder Abschnitt fehlen folgende wichtige Informationen: Es fehlen u. a. Schaltzeichen und graphischen Symbole für Akkumulatoren und Primärzellen Koppelstufen Wählerelemente Fernsprecher Sende und Empfangseinrichtunge … Deutsch Wikipedia
NH-Trenner — Eine Schmelzsicherung ist eine Überstromschutzeinrichtung, die einen Stromkreis bei zu hoher Stromstärke durch die thermische Wirkung des Stroms unterbricht und dadurch zerstört wird. Da sie im Gegensatz zu vielen anderen Sicherungen nach… … Deutsch Wikipedia
Schaltvermögen — Der Ausschaltstrom oder Abschaltstrom ist der Strom, für den ein Schalter, ein Relais oder ein Schützkontakt, ein Lasttrennschalter oder ein Leistungsschalter beim Abschalten des Stromes spezifiziert sind. Bei Sicherungen (Schmelzsicherungen und… … Deutsch Wikipedia
Schmelzsicherung — IEC Symbol Eine Schmelzsicherung ist eine Überstromschutzeinrichtung, die durch das Abschmelzen eines Schmelzleiters den Stromkreis unterbricht, wenn die Stromstärke einen bestimmten Wert während einer ausreichenden Zeit überschreitet. Bisweilen… … Deutsch Wikipedia
Перевод: с английского на все языки
со всех языков на английский- Со всех языков на:
- Английский
- С английского на:
- Все языки
- Немецкий
- Русский