Перевод: со всех языков на французский

с французского на все языки

включать+цепь

  • 1 включать цепь

    v
    eng. fermer un circuit, insérer

    Dictionnaire russe-français universel > включать цепь

  • 2 включать

    * * *
    * * *
    v
    1) gener. agencer (Plusieurs modules peuvent être agencés en série.), comprendre, consister de (La délégation consiste de vingt personnes, dont...), encadrer, englober, inclure (в себя), inscrire (в список), insérer (dans qch), intercaler, mettre en dérivation, mettre en mouvement, mettre en prise, déclencher, allumer (лампу, радиоприёмник, телевизор и т.п.), comporter, comprendre (что-л. во что-л.), connecter, enclencher, incluire, incorporer, introduire, intégrer, mettre
    2) colloq. ouvrir
    3) eng. brancher, embrancher (в сеть), mettre en marche, mettre sous tension, activer (Pour activer le serveur d'archivage, effectuez les tâches suivantes:), allumer (двигатель), brancher (в цепь), enclaver
    5) electr. coupler (в сеть), aiguiller, fermer
    6) IT. habiliter, raccorder
    7) mech.eng. commander l'action, démarrer (напр. станок), embrayer, amorcer, insérer (в цепь)

    Dictionnaire russe-français universel > включать

  • 3 включать

    brancher, coupler, ( в сеть) embrancher, embrasser, ( в состав) incorporer, inclure, mettre en circuit, démarrer, ( в цепь) insérer

    Русско-французский словарь по нефти и газу > включать

  • 4 включать в цепь

    Dictionnaire russe-français universel > включать в цепь

  • 5 автоматический выключатель

    1. interrupteur automatique
    2. disjoncteur
    3. coupe-circuit
    4. conjoncteur-disjoncteur

     

    автоматический выключатель
    Механический коммутационный аппарат
    1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
    (МЭС 441-14-20)
    [ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]

    автоматический выключатель
    -
    [IEV number 442-05-01]

    EN

    circuit breaker
    a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

    circuit breaker

    A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
    NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
    Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
    Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
    Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
    Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
    [National Electrical Cod]

    FR

    disjoncteur
    appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

      1)  Должно быть контактный коммутационный аппарат
    [Интент] 
    КЛАССИФИКАЦИЯ

      0067 Автоматические выключатели ABB   0068 Модульные автоматические выключатели
    1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
    Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
    Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).

    [Интент]
    Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
    [
    Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Электромагнитный расцепитель;
    5 - Сердечник
    6 - Катушка
    7 - Контактные зажимы автоматического выключателя

    Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
    На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
    Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).

    Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем. 

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Тепловой расцепитель
    5 - Биметаллическая пластина
    6 - Нагревательный элемент
    7 - Контактные зажимы автоматического выключателя

    Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
    [Интент]

    Недопустимые, нерекомендуемые

    Тематики

    Классификация

    >>>

    Обобщающие термины

    Действия

    EN

    DE

    FR

    Смотри также

    Русско-французский словарь нормативно-технической терминологии > автоматический выключатель

  • 6 разъединитель

    1. sectionneur

     

    разъединитель
    Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
    Примечание.
    1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
    Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.

    0043 Условное обозначение контакта разъединителя

    [ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]

    разъединитель
    Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
    Примечания
    1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
    2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
    3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
    4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
    [ ГОСТ Р 52726-2007]

    EN

    disconnector
    a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
    NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
    [IEV number 441-14-05]

    disconnector

    IEV 441-14-05 is applicable with the following additional notes:
    NOTE 1
    "Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
    "No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
    NOTE 2
    For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
    [IEC 62271-102]

    FR

    sectionneur
    appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
    NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
    [IEV number 441-14-05]

    Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:

    • изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
    • иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
    • быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
    • обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;

    [ ГОСТ Р МЭК 60204-1-2007]


    Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
    Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
    Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
    Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:

    1. Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
    2. Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
    3. Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
    4. Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
    5. Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
    6. Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.

    [ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]


    Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
    [ http://relay-protection.ru/content/view/46/8/1/1/]


    Параллельные тексты EN-RU

    b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
    [IEC 60204-1-2006]

    б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
    [Перевод Интент]

    Тематики

    • высоковольтный аппарат, оборудование...
    • релейная защита
    • электротехника, основные понятия

    Классификация

    >>>

    EN

    DE

    FR

    Смотри также

    Русско-французский словарь нормативно-технической терминологии > разъединитель

  • 7 контактор (контактный)

    1. contacteur (mécanique)
    2. contacteur

     

    контактор (механический) 1
    Контактный коммутационный аппарат с единственным положением покоя, с управлением не вручную, способным включать, проводить и отключать токи в нормальных условиях цепи, в том числе при рабочих перегрузках.
    МЭК 60050(441-14-33).
    Примечание. Контакторы можно характеризовать способом, которым обеспечивается создание усилия для замыкания главных контактов
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    контактор
    Двухпозиционный аппарат с самовозвратом, предназначенный для частых коммутаций токов, не превышающих токи перегрузки, и приводимый в действие двигательным приводом.
    Примечание. Для аналогичных аппаратов без самовозврата следует применять термин «Контактор без самовозврата».
    [ ГОСТ 17703-72]

    контактор
    Выключатель для дистанционного включения, отключения и переключения силовых электрических цепей
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    EN

    (mechanical) contactor
    a mechanical switching device having only one position of rest, operated otherwise than by hand, capable of making, carrying and breaking currents under normal circuit conditions including operating overload conditions
    NOTE – Contactors may be designated according to the method by which the force for closing the main contacts is provided.
    [IEV number 441-14-33]

    FR

    contacteur (mécanique)
    appareil mécanique de connexion ayant une seule position de repos, commandé autrement qu'à la main, capable d'établir, de supporter et d'interrompre des courants dans les conditions normales du circuit, y compris les conditions de surcharge en service
    NOTE – Les contacteurs peuvent être désignés suivant la façon dont est fourni l'effort nécessaire à la fermeture des contacts principaux.
    [IEV number 441-14-33]

      Должно быть " контактный"
    См., например, выключатель (контактный) - (mechanical) switch
    Коммутационные аппараты следует классифицировать на контактные и полупроводниковые (solid-state)
    [Интент]

    1. Контактор на относительно небольшой номинальный ток, это такой же коммутационный аппарат, как и пускатель, но без теплового реле (можно сказать, что пускатель это контактор плюс тепловое реле).

    2. Контактор на большой номинальный ток выглядит совсем иначе

    0236
    Отечественный контактор КТ-6063

    Число полюсов: 3
    Номинальное напряжение главной цепи: 380 В
    Номинальный ток главной цепи: 1000 А
    Номинальное напряжение катушки: 380 В переменного тока

    Контакторы электромагнитные серии КТ 6000 с естественным воздушным охлаждением предназначены для включения и отключения приемников электрической энергии на номинальное напряжение до 380 В переменного тока частоты 50 и 60Гц.
    Используются в составе оборудования для включения мощных электрических машин и в аппаратуре автоматического включения резерва (АВР).

    3. Контакторами называют также коммутационные аппараты, коммутационная способность которых больше коммутационной способности реле (см. рис. ниже)
    [Интент]

    0230_1
    Рис. Tyco Electronics

    Параллельные тексты EN-RU

    Although contactors are not strictly relays they have the same design principles. Like relays, they are remote controlled switches.
    The difference is the considerably higher input power consumption, higher switching capacity, and larger size.

    [Tyco Electronics]

    Хотя, строго говоря, контакторы не являются реле, их конструкция имеет много общего с конструкцией реле. Также как и реле, они представляют собой коммутационный аппарат с дистационным управлением.
    Отличие состоит в том, что их входная цепь потребляет значительно больший ток, они имеют существенно большую коммутационную способность и их размеры также больше размеров реле.

    [Перевод Интент]

    Недопустимые, нерекомендуемые

    Тематики

    Действия

    Неправильно:- замыкать контактор; - размыкать контактор

    Синонимы

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > контактор (контактный)

См. также в других словарях:

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»