  • 1 Dauerstrombelastbarkeit, f

    1. длительный допустимый ток

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Немецко-русский словарь нормативно-технической терминологии > Dauerstrombelastbarkeit, f

  • 2 Strombelastbarkeit, f

    1. длительный допустимый ток

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Немецко-русский словарь нормативно-технической терминологии > Strombelastbarkeit, f

  • 3 Leistungsschalter

    1. силовой выключатель
    2. автоматический выключатель

     

    автоматический выключатель
    Механический коммутационный аппарат
    1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
    (МЭС 441-14-20)
    [ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]

    автоматический выключатель
    -
    [IEV number 442-05-01]

    EN

    circuit breaker
    a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

    circuit breaker

    A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
    NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
    Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
    Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
    Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
    Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
    [National Electrical Cod]

    FR

    disjoncteur
    appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

      1)  Должно быть контактный коммутационный аппарат
    [Интент] 
    КЛАССИФИКАЦИЯ

      0067 Автоматические выключатели ABB   0068 Модульные автоматические выключатели
    1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
    Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
    Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).

    [Интент]
    Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
    [
    Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Электромагнитный расцепитель;
    5 - Сердечник
    6 - Катушка
    7 - Контактные зажимы автоматического выключателя

    Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
    На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
    Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).

    Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем. 

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Тепловой расцепитель
    5 - Биметаллическая пластина
    6 - Нагревательный элемент
    7 - Контактные зажимы автоматического выключателя

    Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
    [Интент]

    Недопустимые, нерекомендуемые

    Тематики

    Классификация

    >>>

    Обобщающие термины

    Действия

    EN

    DE

    FR

    Смотри также

     

    силовой выключатель
    -
    [Интент]

    EN

    circuit-breaker
    a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit
    [IEV ref 441-14-20]

    FR

    disjoncteur
    appareil mécanique de connexion capable d'établir, de supporter et d'interrompre des courants dans les conditions normales du circuit, ainsi que d'établir, de supporter pendant une durée spécifiée et d'interrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit
    [IEV ref 441-14-20]

    0815
    Рис. Siemens
    Силовой ( баковый элегазовый) выключатель 3AP1 DT

    0816
    Рис. Siemens
    Силовой (колонковый элегазовый) выключатель

    Тематики

    • высоковольтный аппарат, оборудование...
    • комплектное распред. устройство (КРУ)

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Leistungsschalter

  • 4 Trennschalter

    1. разъединитель

     

    разъединитель
    Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
    Примечание.
    1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
    Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.

    0043 Условное обозначение контакта разъединителя

    [ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]

    разъединитель
    Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
    Примечания
    1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
    2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
    3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
    4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
    [ ГОСТ Р 52726-2007]

    EN

    disconnector
    a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
    NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
    [IEV number 441-14-05]

    disconnector

    IEV 441-14-05 is applicable with the following additional notes:
    NOTE 1
    "Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
    "No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
    NOTE 2
    For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
    [IEC 62271-102]

    FR

    sectionneur
    appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
    NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
    [IEV number 441-14-05]

    Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:

    • изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
    • иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
    • быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
    • обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;

    [ ГОСТ Р МЭК 60204-1-2007]


    Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
    Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
    Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
    Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:

    1. Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
    2. Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
    3. Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
    4. Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
    5. Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
    6. Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.

    [ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]


    Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
    [ http://relay-protection.ru/content/view/46/8/1/1/]


    Параллельные тексты EN-RU

    b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
    [IEC 60204-1-2006]

    б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
    [Перевод Интент]

    Тематики

    • высоковольтный аппарат, оборудование...
    • релейная защита
    • электротехника, основные понятия

    Классификация

    >>>

    EN

    DE

    FR

    Смотри также

    Немецко-русский словарь нормативно-технической терминологии > Trennschalter

  • 5 Schaltanlagen und/oder Schaltgeräte

    1. НКУ распределения и управления
    2. аппаратура распределения и управления

     

    аппаратура распределения и управления
    Общий термин для коммутационных аппаратов и их комбинации с относящимися к ним устройствами управления, измерения, защиты и регулирования, а также для узлов, в которых такие аппараты и устройства соединяются с соответствующими фидерами, комплектующим оборудованием, оболочками и опорными конструкциями.
    МЭК 60050 (441-11-01) [1].
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    EN

    switchgear and controlgear
    general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEC 62271-1, ed. 1.0 (2007-10)]

    FR

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu’aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEC 62271-1, ed. 1.0 (2007-10)]

    Тематики

    • аппарат, изделие, устройство...

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

    Немецко-русский словарь нормативно-технической терминологии > Schaltanlagen und/oder Schaltgeräte

  • 6 Selbstschalter

    1. автоматический выключатель

     

    автоматический выключатель
    Механический коммутационный аппарат
    1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
    (МЭС 441-14-20)
    [ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]

    автоматический выключатель
    -
    [IEV number 442-05-01]

    EN

    circuit breaker
    a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

    circuit breaker

    A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
    NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
    Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
    Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
    Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
    Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
    [National Electrical Cod]

    FR

    disjoncteur
    appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

      1)  Должно быть контактный коммутационный аппарат
    [Интент] 
    КЛАССИФИКАЦИЯ

      0067 Автоматические выключатели ABB   0068 Модульные автоматические выключатели
    1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
    Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
    Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).

    [Интент]
    Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
    [
    Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Электромагнитный расцепитель;
    5 - Сердечник
    6 - Катушка
    7 - Контактные зажимы автоматического выключателя

    Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
    На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
    Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).

    Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем. 

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Тепловой расцепитель
    5 - Биметаллическая пластина
    6 - Нагревательный элемент
    7 - Контактные зажимы автоматического выключателя

    Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
    [Интент]

    Недопустимые, нерекомендуемые

    Тематики

    Классификация

    >>>

    Обобщающие термины

    Действия

    EN

    DE

    FR

    Смотри также

    Немецко-русский словарь нормативно-технической терминологии > Selbstschalter

  • 7 Anlauf mit direktem Einschalten

    1. прямой пуск вращающегося электродвигателя

     

    прямой пуск вращающегося электродвигателя
    Пуск вращающегося электродвигателя путем непосредственного подключения его к питающей сети.
    [ ГОСТ 27471-87]

    EN

    direct-on-line starting
    across-the-line starting (US)
    the process of starting a motor by connecting it directly to the supply at rated voltage
    [IEV number 411-52-15]

    FR

    démarrage direct
    mode de démarrage d'un moteur, consistant à lui appliquer directement sa pleine tension assignée
    [IEV number 411-52-15]

    0855
    Рис. ABB
    Схема прямого пуска электродвигателя

    Magnetic only circuit-breaker - Автоматический выключатель с электромагнитным расцепителем

    Contactor KL - Контактор KL

    Thermal relay - Тепловое реле

     

    Параллельные тексты EN-RU

    Direct-on-line starting

    Direct-on-line starting, which is often abbreviated as DOL, is perhaps the most traditional system and consists in connecting the motor directly to the supply network, thus carrying out starting at full voltage.

    Direct-on-line starting represents the simplest and the most economical system to start a squirrel-cage asynchronous motor and it is the most used.

    As represented in Figure 5, it provides the direct connection to the supply network and therefore starting is carried out at full voltage and with constant frequency, developing a high starting torque with very reduced acceleration times.

    The typical applications are relevant to small power motors also with full load starting.

    These advantages are linked to some problems such as, for example, the high inrush current, which - in the first instants - can reach values of about 10 to 12 times the rated current, then can decrease to about 6 to 8 times the rated current and can persist to reach the maximum torque speed.

    The effects of such currents can be identified with the high electro-dynamical stresses on the motor connection cables and could affect also the windings of the motor itself; besides, the high inrush torques can cause violent accelerations which stress the transmission components (belts and joints) generating distribution problems with a reduction in the mechanical life of these elements.

    Finally, also the possible electrical problems due to voltage drops on the supply line of the motor or of the connected equipment must be taken into consideration.
    [ABB]

    Прямой пуск

    Прямой пуск, который по-английски часто сокращенно обозначают как DOL, является, пожалуй наиболее распространенным способом пуска. Он заключается в непосредственном (т. е. прямом) подключении двигателя к питающей сети. Это означает, что пуск двигателя осуществляется при полном напряжении.

    Схема прямого пуска является наиболее простым, экономичным и чаще всего применяемым решением для электродвигателей с короткозамкнутым ротором.

    Схема прямого подключения к сети представлена на рисунке 5. Пуск осуществляется при полном напряжении и постоянной частоте сети. Электродвигатель развивает высокий пусковой момент при коротком времени разгона.

    Типичные области применения – маломощные электродвигатели, в том числе с пуском при полной нагрузке.

    Однако, наряду с преимуществами имеются и определенные недостатки, например, бросок пускового тока, достигающий в первоначальный момент 10…12-кратного значения от номинального тока электродвигателя. Затем ток двигателя уменьшается примерно до 6…8-кратного значения номинального тока и будет держаться на этом уровне до тех пор, пока скорость двигателя не достигнет максимального значения.

    Такое изменение тока оказывает значительное электродинамическое воздействие на кабель, подключенный к двигателю. Кроме того пусковой ток воздействует на обмотки двигателя. Высокий начальный пусковой момент может привести к значительному ускорению и следовательно к значительной нагрузке элементов привода (ремней, крепления узлов), что вызывает сокращение их срока службы.

    И, наконец, следует принять во внимание возможное возникновение проблем, связанных с падением напряжения в линии питания двигателя и подключенного к этой линии оборудования.
    [Перевод Интент]




     

    Тематики

    Синонимы

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Anlauf mit direktem Einschalten

  • 8 Wicklung

    1. обмотка
    2. намотанная нить

     

    намотанная нить
    Нить, намотанная на нитеноситель или непосредственно на шпиндель веретена.
    Примечание
    Намотанная нить на нитеноситель может иметь цилиндрическую, коническую или другую форму.
    [ ГОСТ 28994-91( ИСО 5239-80)]

    Тематики

    EN

    DE

    FR

     

     

    обмотка
    Совокупность витков, образующих электрическую цепь с целью получения одного из напряжений трансформатора.
    Примечание — Для трехфазного трансформатора под «обмоткой» подразумевается совокупность соединяемых между собой обмоток одного напряжения всех фаз, см. 3.3.3
    (МЭС 421-03-01).
    [ ГОСТ 30830-2002]

    обмотка
    Ндп. намотка
    По ГОСТ 18311-80
    [ ГОСТ 20718-75]

    обмотка
    Изолированный проводник, уложенный в специфическом порядке, предназначенный для возбуждения магнитного поля при протекании по нему электрического тока
    [Система неразрушающего контроля. Виды (методы) и технология неразрушающего контроля. Термины и определения (справочное пособие). Москва 2003 г.]

    обмотка
    -
    [IEV number 151-13-17]

    EN

    winding
    the assembly of turns forming an electric circuit associated with one of the voltages assigned to the transformer or to the reactor
    NOTE – For a polyphase transformer or polyphase reactor, the "winding" is the combination of the phase windings
    [IEV number 421-03-01]


    winding
    assembly of interconnected turns and/or coils intended for common operation
    NOTE – A winding is provided with terminals and is intended to produce a magnetic field when carrying electric currents or to produce voltages between appropriate points when placed in a time-varying magnetic field or moved through a magnetic field.
    [IEV number 151-13-17]

    FR

    enroulement
    ensemble des spires formant un circuit électrique associé à l'une des tensions pour lesquelles le transformateur ou la bobine d'inductance ont été établis
    NOTE – Pour un transformateur polyphasé ou pour une bobine d'inductance polyphasée, l"enroulement" est l'ensemble des enroulements de phase.
    [IEV number 421-03-01]


    enroulement, m
    ensemble de spires ou de bobines interconnectées et destinées à fonctionner conjointement
    NOTE – Un enroulement est muni de bornes et est destiné à produire un champ magnétique lorsqu’il est parcouru par des courants électriques ou à produire des tensions électriques entre des points appropriés lorsqu’il est placé dans un champ magnétique variable dans le temps ou déplacé dans un champ magnétique.
    [IEV number 151-13-17]

    Недопустимые, нерекомендуемые

    Тематики

    Классификация

    >>>

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Wicklung

  • 9 Benzinbleigesetz

    1. закон об уровне содержания свинца в автомобильном топливе

     

    закон об уровне содержания свинца в автомобильном топливе

    [ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    EN

    lead-in-petrol law
    A binding rule or body of rules prescribed by a government to reduce or eliminate the lead content in petroleum fuels used in vehicular and other engines that pollute the air with lead-carrying exhaust. (Source: GAS)
    [http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    Тематики

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Benzinbleigesetz

  • 10 Pferd

    1. лошадь

     

    лошадь

    [ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    EN

    horse
    A large animal with four legs which people ride on or use for carrying things or pulling vehicles. (Source: CAMB)
    [http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    Тематики

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Pferd

  • 11 Überstrom

    1. сверхток

     

    сверхток
    Любой ток, превышающий номинальный
    МЭК 60050(441-11-06).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    [ ГОСТ Р 50345-99( МЭК 60898-95)]

    сверхток
    Электрический ток, превышающий номинальный электрический ток.
    Сверхток представляет собой любой электрический ток, величина которого превышает номинальный ток какого-либо элемента электроустановки здания или используемого в ней электрооборудования, например: номинальный ток электрической цепи, допустимый длительный ток проводника, номинальный ток автоматического выключателя и т. д. В нормативной и правовой документации различают два основных вида сверхтока – ток перегрузки и ток короткого замыкания.
    Появление сверхтока в каком-либо элементе электроустановки здания может привести к его перегреву, возгоранию и, как следствие, к возникновению пожара в здании. Поэтому в электроустановках зданий выполняют защиту от сверхтока.
    [ http://www.volt-m.ru/glossary/letter/%D1/view/59/]

    сверхток
    сверхток в электротехническом изделии
    Ток, значение которого превосходит наибольшее рабочее значение тока электротехнического изделия (устройства).
    [ ГОСТ 18311-80]

    сверхток
    Электрический ток, превышающий номинальный электрический ток.
    Примечание - Для проводников номинальный ток считается равным длительному допустимому току.
    [ ГОСТ Р МЭК 60050-826-2009]

    Сверхток может оказывать или может не оказывать вредные воздействия в зависимости от его величины и продолжительности. Сверхтоки могут возникать в результате перегрузок в электроприемниках или при повреждениях, таких как короткие замыкания или замыканиях на землю
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    сверхток
    Любой ток, превышающий номинальное значение. Для проводов номинальным значением является допустимый ток.
    [ ГОСТ Р МЭК 60204-1-2007]

    EN

    overcurrent
    electric current exceeding the rated electric current
    NOTE – For conductors, the rated current is considered as equal to the current-carrying capacity
    [IEV number 826-11-14]


    over-current
    <>current exceeding the rated current
    <>[IEC 61095, ed. 2.0 (2009-02)]


    over-current
    electric current the value of which exceeds a specified limiting value
    [IEV number 151-15-28]
    [IEV number 442-01-20]

    FR

    surintensité, f
    courant électrique supérieur au courant électrique assigné
    NOTE – Pour des conducteurs, on considère que le courant assigné est égal au courant admissible.
    [IEV number 826-11-14]


    surintensité
    courant supérieur au courant assigné
    [IEC 61095, ed. 2.0 (2009-02)]
    [IEV number 442-01-20]
    surintensité, f
    courant électrique dont la valeur dépasse une valeur limite spécifiée
    [IEV number 151-15-28]

    Параллельные тексты EN-RU

    The design of LV installations leads to basic protection devices being fitted for three types of faults:

    • overloads
    • short-circuits
    • insulation faults
    [Schneider Electric]

    Низковольтные электроустановки должны быть оснащены устройствами защиты трех типов:

    • от перегрузки;
    • от короткого замыкания;
    • от токов утечки.

    [Перевод Интент]

    Примечание
    .
    Слово fault в данном случае пришлось опустить, поскольку:
    - его нельзя перевести как "неисправность", т. к. возникновение 
    перегрузки ( overload) не является неисправностью;
    - его нельзя перевести как "сверхток", т. к. ток утечки не является сверхтоком
    .

    The chosen switchgear must withstand and eliminate faults at optimised cost with respect to the necessary performance.
    [Schneider Electric]

    Выбранная аппаратура распределения должна иметь такие характеристики, чтобы рентабельно выдерживать и ограничивать сверхтоки.
    [Перевод Интент]

     

    Тематики

    Синонимы

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Überstrom

  • 12 Überstrom(stärke)

    1. сверхток

     

    сверхток
    Любой ток, превышающий номинальный
    МЭК 60050(441-11-06).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    [ ГОСТ Р 50345-99( МЭК 60898-95)]

    сверхток
    Электрический ток, превышающий номинальный электрический ток.
    Сверхток представляет собой любой электрический ток, величина которого превышает номинальный ток какого-либо элемента электроустановки здания или используемого в ней электрооборудования, например: номинальный ток электрической цепи, допустимый длительный ток проводника, номинальный ток автоматического выключателя и т. д. В нормативной и правовой документации различают два основных вида сверхтока – ток перегрузки и ток короткого замыкания.
    Появление сверхтока в каком-либо элементе электроустановки здания может привести к его перегреву, возгоранию и, как следствие, к возникновению пожара в здании. Поэтому в электроустановках зданий выполняют защиту от сверхтока.
    [ http://www.volt-m.ru/glossary/letter/%D1/view/59/]

    сверхток
    сверхток в электротехническом изделии
    Ток, значение которого превосходит наибольшее рабочее значение тока электротехнического изделия (устройства).
    [ ГОСТ 18311-80]

    сверхток
    Электрический ток, превышающий номинальный электрический ток.
    Примечание - Для проводников номинальный ток считается равным длительному допустимому току.
    [ ГОСТ Р МЭК 60050-826-2009]

    Сверхток может оказывать или может не оказывать вредные воздействия в зависимости от его величины и продолжительности. Сверхтоки могут возникать в результате перегрузок в электроприемниках или при повреждениях, таких как короткие замыкания или замыканиях на землю
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    сверхток
    Любой ток, превышающий номинальное значение. Для проводов номинальным значением является допустимый ток.
    [ ГОСТ Р МЭК 60204-1-2007]

    EN

    overcurrent
    electric current exceeding the rated electric current
    NOTE – For conductors, the rated current is considered as equal to the current-carrying capacity
    [IEV number 826-11-14]


    over-current
    <>current exceeding the rated current
    <>[IEC 61095, ed. 2.0 (2009-02)]


    over-current
    electric current the value of which exceeds a specified limiting value
    [IEV number 151-15-28]
    [IEV number 442-01-20]

    FR

    surintensité, f
    courant électrique supérieur au courant électrique assigné
    NOTE – Pour des conducteurs, on considère que le courant assigné est égal au courant admissible.
    [IEV number 826-11-14]


    surintensité
    courant supérieur au courant assigné
    [IEC 61095, ed. 2.0 (2009-02)]
    [IEV number 442-01-20]
    surintensité, f
    courant électrique dont la valeur dépasse une valeur limite spécifiée
    [IEV number 151-15-28]

    Параллельные тексты EN-RU

    The design of LV installations leads to basic protection devices being fitted for three types of faults:

    • overloads
    • short-circuits
    • insulation faults
    [Schneider Electric]

    Низковольтные электроустановки должны быть оснащены устройствами защиты трех типов:

    • от перегрузки;
    • от короткого замыкания;
    • от токов утечки.

    [Перевод Интент]

    Примечание
    .
    Слово fault в данном случае пришлось опустить, поскольку:
    - его нельзя перевести как "неисправность", т. к. возникновение 
    перегрузки ( overload) не является неисправностью;
    - его нельзя перевести как "сверхток", т. к. ток утечки не является сверхтоком
    .

    The chosen switchgear must withstand and eliminate faults at optimised cost with respect to the necessary performance.
    [Schneider Electric]

    Выбранная аппаратура распределения должна иметь такие характеристики, чтобы рентабельно выдерживать и ограничивать сверхтоки.
    [Перевод Интент]

     

    Тематики

    Синонимы

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Überstrom(stärke)

  • 13 Ölpestbekämpfung

    1. уменьшение нефтяного загрязнения

     

    уменьшение нефтяного загрязнения

    [ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    EN

    oil pollution abatement
    There are various systems for the abatement of oil pollution at sea: the "Load-on-top" system involves passing the washing from tank cleaning operations and residue from discharge of the original ballast water to an empty cargo tank nominated as the "slop" tank. Fresh oil cargo is loaded on top of the final residue left after further discharges of water, the resulting mixture being acceptable to refineries despite some additional cost in removing the salt and water. Under the International Convention for the Prevention of Pollution from Ships, 1973, all oil-carrying ships will be required to be capable of operating with this method of retention, or alternatively to discharge to reception facilities. Another method consists in spraying on the oil dispersives and/or blasting straw and sawdust, functioning as "blotting paper", onto water, beaches, rocks and docks. The Vikoma System for the containment of oil spills at sea, developed by British Petroleum, a seaboom of about 500 metres in length, is inflated and towed downwind of the oil slick and formed into a U-shape; under the influence of wind, the oil becomes trapped within the boom. Skimming equipment travels into the boom enclosure and the oil is pumped into containers. (Source: GILP)
    [http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    Тематики

    EN

    DE

    FR

    Немецко-русский словарь нормативно-технической терминологии > Ölpestbekämpfung

См. также в других словарях:

  • carrying case — noun, pl ⋯ cases [count] : a container that usually has a handle and that is made for carrying something with your hand The guitar had a plastic carrying case …   Useful english dictionary

  • Carrying On — Studio album by Montgomery Gentry Released May 1, 2001 ( …   Wikipedia

  • Carrying (basketball) — Carrying, also colloquially referred to as palming, is a violation in the game of basketball. It occurs when the dribbling player continues to dribble after allowing the ball to come to rest in one or both hands. Carrying is similar to a double… …   Wikipedia

  • Carrying — Car ry*ing, n. The act or business of transporting from one place to another. [1913 Webster] {Carrying place}, a carry; a portage. {Carrying trade}, the business of transporting goods, etc., from one place or country to another by water or land;… …   The Collaborative International Dictionary of English

  • Carrying place — Carrying Car ry*ing, n. The act or business of transporting from one place to another. [1913 Webster] {Carrying place}, a carry; a portage. {Carrying trade}, the business of transporting goods, etc., from one place or country to another by water… …   The Collaborative International Dictionary of English

  • Carrying trade — Carrying Car ry*ing, n. The act or business of transporting from one place to another. [1913 Webster] {Carrying place}, a carry; a portage. {Carrying trade}, the business of transporting goods, etc., from one place or country to another by water… …   The Collaborative International Dictionary of English

  • carrying on business — A routine and continuous involvement in an activity undertaken for the purpose of making profit. This can be accomplished with or without a physical or visible business entity. Category: Business, LLCs & Corporations → Business Accounting,… …   Law dictionary

  • with — W1S1 [wıð, wıθ] prep [: Old English; Origin: against, from, with ] 1.) used to say that two or more people or things are together in the same place ▪ I saw Bob in town with his girlfriend. ▪ Put this bag with the others. ▪ I always wear these… …   Dictionary of contemporary English

  • with — [ wıð, wıθ ] preposition *** 1. ) together if one person or thing is with another or does something with them, they are together or they do it together: Hannah lives with her parents. chicken served with vegetables and mushrooms I ll be with you… …   Usage of the words and phrases in modern English

  • carrying charge — ☆ carrying charge n. 1. interest or other extra charge paid on the balance owed in installment buying 2. the costs associated with property ownership, as taxes, upkeep, etc …   English World dictionary

  • Carrying capacity — The supportable population of an organism, given the food, habitat, water and other necessities available within an environment is known as the environment s carrying capacity for that organism. For the human population, more complex variables… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»