1 номинальное напряжение изоляции (соединительного устройства)
напряжение по изоляции
Напряжение, определяемое изготовителем для данного соединителя и его составных частей, с которыми соотносятся испытания на электрическую прочность изоляции, воздушные зазоры и расстояния утечки.
[ ГОСТ Р 51323.1-99]
номинальное напряжение изоляции (соединительного устройства)
-
[IEV number 442-06-39]EN
rated insulation voltage, (of a connecting device)
phase/neutral or phase/phase voltage value assigned to the connecting device by the manufacturer, this device being intended to be used in installations, the voltage supply of which does not exceed the rated insulation voltage of the connecting device itself
NOTE – Rated insulation voltage is always understood to be between live parts and not between live parts and earth (ground).
[IEV number 442-06-39]FR
tension d'isolement assignée (d'un dispositif de connexion)
valeur de la tension phase/neutre ou phase/phase assignée par le constructeur du dispositif de connexion, celui-ci étant prévu pour être utilisé dans des installations dont la tension d'alimentation ne dépasse pas la tension d'isolement assignée du dispositif de connexion lui-même
NOTE – La tension d'isolement assignée est toujours comprise comme la tension entre parties sous tension et non entre parties sous tension et terre.
[IEV number 442-06-39]Тематики
EN
- rated insulation voltage, (of a connecting device)
DE
FR
Русско-французский словарь нормативно-технической терминологии > номинальное напряжение изоляции (соединительного устройства)
-
2 ожидаемое восстанавливающееся напряжение (цепи)
ожидаемое восстанавливающееся напряжение (цепи)
Напряжение после отключения ожидаемого симметричного тока идеальным коммутационным аппаратом.
Примечание. Определение подразумевает, что коммутационный аппарат или плавкий предохранитель, для которого оценивается ожидаемое восстанавливающее напряжение, заменен идеальным коммутационным аппаратом, т. е. с мгновенным переходом от нулевого к бесконечному полному сопротивлению в самый момент уменьшения тока до нуля, т. е. при «естественном» нуле. Для цепей, в которых ток может проходить по нескольким различным путям, например для многофазной цепи, это определение подразумевает также, что ток отключается идеальным коммутационным аппаратом только в рассматриваемом полюсе.
МЭК 60050(441-17-29)
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
prospective transient recovery voltage (of a circuit)
the transient recovery voltage following the breaking of the prospective symmetrical current by an ideal switching device
NOTE – The definition assumes that the switching device or the fuse, for which the prospective transient recovery voltage is sought, is replaced by an ideal switching device, i.e. having instantaneous transition from zero to infinite impedance at the very instant of zero current, i.e. at the "natural" zero. For circuits where the current can follow several different paths, e.g. a polyphase circuit, the definition further assumes that the breaking of the current by the ideal switching device takes place only in the pole considered.
[IEV number 441-17-29]FR
tension transitoire de rétablissement présumée (d'un circuit)
tension transitoire de rétablissement qui suit la coupure du courant présumé symétrique par un appareil de connexion idéal
NOTE – La définition implique que l'appareil de connexion ou le fusible, pour lequel la tension transitoire de rétablissement est recherchée, est remplacé par un appareil de connexion idéal, c'est-à-dire dont l'impédance passe instantanément de la valeur zéro à la valeur infinie à l'instant du zéro de courant, c'est-à-dire au zéro "naturel". Pour des circuits ayant plusieurs voies, par exemple un circuit polyphasé, on suppose en outre que la coupure du courant par l'appareil de connexion idéal n'a lieu que sur le pôle considéré.
[IEV number 441-17-29]EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > ожидаемое восстанавливающееся напряжение (цепи)
-
3 напряжение до включения (коммутационного аппарата)
напряжение до включения (коммутационного аппарата)
Напряжение между выводами полюса коммутационного аппарата непосредственно перед включением тока.
Примечание. Определение действительно для однополюсного аппарата. Для многополюсного аппарата это межфазное напряжение на входных выводах аппарата.
МЭК 60050(441-17-24).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
applied voltage (for a switching device)
the voltage which exists across the terminals of a pole of a switching device just before the making of the current
[IEV number 441-17-24]FR
tension appliquée (pour un appareil de connexion)
tension qui existe entre les bornes d'un pôle d'un appareil de connexion immédiatement avant l'établissement du courant
[IEV number 441-17-24]Тематики
- аппарат, изделие, устройство...
- выключатель автоматический
- выключатель, переключатель
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > напряжение до включения (коммутационного аппарата)
-
4 пиковое напряжение дуги (в контактном коммутационном аппарате)
пиковое напряжение дуги (в контактном коммутационном аппарате)
Максимальное мгновенное значение напряжения, появляющегося в заданных условиях на выводах полюса коммутационного аппарата во время дуги.
МЭК 60050(441-17-30)
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
peak arc voltage (of a mechanical switching device)
the maximum instantaneous value of voltage which under prescribed conditions appears across the terminals of a pole of a switching device during the arcing time
[IEV number 441-17-30]FR
tension d'arc (d'un appareil de connexion) (en valeur de crête)
valeur maximale instantanée de tension qui, dans des conditions prescrites, apparaît entre les bornes d'un pôle d'un appareil de connexion pendant la durée d'arc
[IEV number 441-17-30]Тематики
- аппарат, изделие, устройство...
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > пиковое напряжение дуги (в контактном коммутационном аппарате)
-
5 переходное восстанавливающееся напряжение
переходное восстанавливающееся напряжение
ПВН
Восстанавливающееся напряжение в течение времени, когда оно имеет заметно выраженный переходный характер. Оно может быть колебательным или апериодическим или их комбинацией, в зависимости от характеристик цепи и выключателя, отражает также смещение напряжения нейтрали многофазной цепи.
ПВН в трехфазных цепях, если не оговорено иное, - это напряжение между выводами первого гасящего полюса, так как это напряжение обычно выше, чем на каждом из двух других полюсов.
[ ГОСТ Р 52565-2006]
переходное восстанавливающееся напряжение
ПВН
Восстанавливающееся напряжение в период времени, когда оно имеет заметно выраженный переходный характер.
Примечания
1 Переходное восстанавливающееся напряжение может быть колебательным или неколебательным или их комбинацией в зависимости от характеристик цепи и коммутационного аппарата. Оно отражает также смещение напряжения нейтрали многофазной цепи.
2 Если не оговорено иначе, переходное восстанавливающееся напряжение в трехфазных цепях представляет собой напряжение между выводами первого отключающего полюса, так как это напряжение обычно более высокое, чем то, которое появляется между выводами каждого из двух других полюсов
[ ГОСТ Р 52726-2007]
восстанавливающееся напряжение 1)
Напряжение в период, когда оно носит в значительной степени переходный характер.
Примечание. Переходное напряжение может быть колебательным или неколебательным, или носить смешанный характер в зависимости от характеристик цепи, коммутационного аппарата или плавкого предохранителя. Сюда относится и сдвиг напряжения нейтрали многофазной цепи.
МЭК 60050(441-17-26)
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
1) Должно быть переходное восстанавливающееся напряжение
[Интент]
восстанавливающееся напряжение 1)
Напряжение в период, когда оно носит в значительной степени переходный характер.
Примечания
1 Это переходное напряжение может быть колебательным или неколебательным, или их комбинацией, в зависимости от характеристик цепи и выключателя. При этом учитывают сдвиг напряжения нейтрали многофазной цепи.
2 Восстанавливающееся напряжение в трехфазных цепях в отсутствие других указаний — это напряжение между выводами первого полюса, отключающего ток, поскольку оно, как правило, выше, чем между выводами каждого из двух других полюсов
(МЭС 441-17-26)
[ ГОСТ Р 50345-99( МЭК 60898-95)]
1) Должно быть переходное восстанавливающееся напряжение
[Интент]EN
transient recovery voltage
T.R.V. (abbreviation)
the recovery voltage during the time in which it has a significant transient character
NOTE 1 – The transient recovery voltage may be oscillatory or non-oscillatory or a combination of these depending on the characteristics of the circuit and the switching device. It includes the voltage shift of the neutral of a polyphase circuit.
NOTE 2 – The transient recovery voltages in three-phase circuits is, unless otherwise stated, that across the first pole to clear, because this voltage is generally higher than that which appears across each of the other two poles.
[IEV number 441-17-26 ]FR
tension transitoire de rétablissement
T.T.R. (abréviation)
tension de rétablissement pendant le temps où elle présente un caractère transitoire appréciable
NOTE 1 – La tension transitoire de rétablissement peut être oscillatoire ou non oscillatoire ou être une combinaison de celles-ci selon les caractéristiques du circuit et de l'appareil de connexion. Elle tient compte de la variation du potentiel du point neutre du circuit polyphasé.
NOTE 2 – Sauf spécification contraire, la tension transitoire de rétablissement pour les circuits triphasés est la tension aux bornes du premier pôle qui coupe, car cette tension est généralement plus élevée que celle qui apparaît aux bornes de chacun des deux autres pôles.
[IEV number 441-17-26 ]Тематики
- выключатель, переключатель
- высоковольтный аппарат, оборудование...
Синонимы
EN
- T.R.V.
- transient recovery voltage
DE
FR
Русско-французский словарь нормативно-технической терминологии > переходное восстанавливающееся напряжение
-
6 восстанавливающееся и возвращающееся напряжение
восстанавливающееся и возвращающееся напряжение
Напряжение, появляющееся на выводах полюса коммутационного аппарата или плавкого предохранителя после отключения тока..
Примечания
1 Напряжение можно рассматривать на протяжении двух последовательных интервалов времени, на первом из которых напряжение переходное, а на последующем — промышленной частоты.
2 Определение действительно для однополюсного аппарата. Для многополюсного аппарата — это межфазное напряжение на входных выводах аппаратов.
МЭК 60050(441-17-25)
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
recovery voltage
the voltage which appears across the terminals of a pole of a switching device or a fuse after the breaking of the current
NOTE – This voltage may be considered in two successive intervals of time, one during which a transient voltage exists, followed by a second one during which the power frequency or the steady-state recovery voltage alone exists.
[IEV number 441-17-25]FR
tension de rétablissement
tension qui apparaît entre les bornes d'un appareil de connexion ou d'un fusible après l'interruption du courant
NOTE – Cette tension peut être considérée durant deux intervalles de temps consécutifs, l'un durant lequel existe une tension transitoire, suivi par un second intervalle durant lequel la tension de rétablissement à fréquence industrielle ou en régime établi existe seule.
[IEV number 441-17-25]Тематики
- электротехника, основные понятия
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > восстанавливающееся и возвращающееся напряжение
-
7 восстанавливающееся напряжение
восстанавливающееся напряжение
Напряжение, появляющееся на выводах полюса автоматического выключателя после отключения тока.
Примечания
1 Это напряжение можно рассматривать на протяжении двух последовательных интервалов времени, на первом из которых напряжение переходное, а на последующем втором — напряжение промышленной частоты.
2 Это определение действительно для однополюсного выключателя. Для многополюсного выключателя — это напряжение между входными выводами аппарата
(МЭС 441-17-25)
[ ГОСТ Р 50345-99( МЭК 60898-95)]
восстанавливающееся напряжение
-
[Лугинский Я. Н. и др. Англо-русский словарь по электротехнике и электроэнергетике. 2-е издание - М.: РУССО, 1995 - 616 с.]EN
recovery voltage
the voltage which appears across the terminals of a pole of a switching device or a fuse after the breaking of the current
NOTE – This voltage may be considered in two successive intervals of time, one during which a transient voltage exists, followed by a second one during which the power frequency or the steady-state recovery voltage alone exists.
[IEV number 441-17-25]FR
tension de rétablissement
tension qui apparaît entre les bornes d'un appareil de connexion ou d'un fusible après l'interruption du courant
NOTE – Cette tension peut être considérée durant deux intervalles de temps consécutifs, l'un durant lequel existe une tension transitoire, suivi par un second intervalle durant lequel la tension de rétablissement à fréquence industrielle ou en régime établi existe seule
[IEV number 441-17-25]Тематики
- выключатель, переключатель
- высоковольтный аппарат, оборудование...
EN
- cleaning voltage
- recovery voltage
- restoring voltage
- restriking voltage
- transient recovery voltage
- TRV
DE
FR
Русско-французский словарь нормативно-технической терминологии > восстанавливающееся напряжение
-
8 восстанавливающееся напряжение (для контактора и пускателя)
восстанавливающееся напряжение
Напряжение, появляющееся на выводах полюса автоматического выключателя после отключения тока.
Примечания
1 Это напряжение можно рассматривать на протяжении двух последовательных интервалов времени, на первом из которых напряжение переходное, а на последующем втором — напряжение промышленной частоты.
2 Это определение действительно для однополюсного выключателя. Для многополюсного выключателя — это напряжение между входными выводами аппарата
3 У вакуумного контактора или пускателя наибольшее восстанавливающееся напряжение возможно не на первом отключаемом полюсе
(МЭС 441-17-25)
[ ГОСТ Р 50030.4.1-2002 (МЭК 60947-4-1-2000)]EN
recovery voltage
the voltage which appears across the terminals of a pole of a switching device or a fuse after the breaking of the current
NOTE – This voltage may be considered in two successive intervals of time, one during which a transient voltage exists, followed by a second one during which the power frequency or the steady-state recovery voltage alone exists.
[IEV number 441-17-25]FR
tension de rétablissement
tension qui apparaît entre les bornes d'un appareil de connexion ou d'un fusible après l'interruption du courant
NOTE – Cette tension peut être considérée durant deux intervalles de temps consécutifs, l'un durant lequel existe une tension transitoire, suivi par un second intervalle durant lequel la tension de rétablissement à fréquence industrielle ou en régime établi existe seule
[IEV number 441-17-25]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > восстанавливающееся напряжение (для контактора и пускателя)
-
9 напряжение автоматического размыкания контактов устройства дифференциального тока при неисправности вспомогательного источника питания
- tension d'ouverture de la source auxiliaire pour dispositif différentiel ouvrant automatiquement en cas de défaillance de la source auxiliaire
напряжение автоматического размыкания контактов устройства дифференциального тока при неисправности вспомогательного источника питания
-
[IEV number 442-05-34]EN
opening voltage of the auxiliary source for residual current devices which open automatically in case of failure of the auxiliary source
value of the voltage of the auxiliary source below which the residual current device opens automatically in the absence of any residual current
[IEV number 442-05-34]FR
tension d'ouverture de la source auxiliaire pour dispositif différentiel ouvrant automatiquement en cas de défaillance de la source auxiliaire
valeur de la tension de la source auxiliaire en dessous de laquelle le dispositif de coupure différentiel s'ouvre automatiquement, en l'absence de tout courant différentiel
[IEV number 442-05-34]Тематики
EN
- opening voltage of the auxiliary source for residual current devices which open automatically in case of failure of the auxiliary source
DE
- Ausschaltspannung der Hilfsenergieversorgung einer im Fehlerfall automatisch ausschaltenden Fehlerstrom-Schutzeinrichtung
FR
- tension d'ouverture de la source auxiliaire pour dispositif différentiel ouvrant automatiquement en cas de défaillance de la source auxiliaire
Русско-французский словарь нормативно-технической терминологии > напряжение автоматического размыкания контактов устройства дифференциального тока при неисправности вспомогательного источника питания
-
10 минимальный расцепитель напряжения
минимальный расцепитель напряжения
Расцепитель, автоматически срабатывающий, когда подаваемое напряжение опускается ниже заданного уровня.
[ ГОСТ Р 50030.4.1-2002 (МЭК 60947-4-1-2000)]
минимальное реле или минимальной расцепитель напряжения
Реле или расцепитель, допускающие размыкание или замыкание контактного коммутационного аппарата с выдержкой времени или без нее, когда напряжение на выводах этого реле или расцепителя падает ниже заданной величины
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
under-voltage release
a shunt release which permits a mechanical switching device to open or close, with or without time-delay, when the voltage across the terminals of the release falls below a predetermined value.
[IEC 62271-100, ed. 2.0 (2008-04)
undervoltage release
release which causes a CBE to open, with or without delay, when the voltage across the terminals of the release falls below a predetermined value
[IEC 60934, ed. 3.0 (2000-10)]FR
déclencheur à minimum de tension
déclencheur shunt qui permet l’ouverture ou la fermeture, avec ou sans retard, d’un appareil mécanique de connexion lorsque la tension aux bornes du déclencheur tombe au-dessous d’une valeur prédéterminée.
[IEC 62271-100, ed. 2.0 (2008-04)]
déclencheur à manque de tension
déclencheur qui provoque l'ouverture du DPE avec ou sans retard, lorsque la tension aux bornes du déclencheur tombe au-dessous d'une valeur prédéterminée
[IEC 60934, ed. 3.0 (2000-10)]
Параллельные тексты EN-RU
The undervoltage trip automatically opens a circuit breaker when voltage drops to a value ranging between 35% to 70% of the line voltage.
The operation is instantaneous, and the circuit breaker cannot be reclosed until the voltage returns to 85% of line voltage.
Continuously energized, the undervoltage trip must be operating before the circuit breaker can be closed.
[LS Industrial Systems]Минимальный расцепитель напряжения вызывает срабатывание автоматического выключателя, если линейное напряжение защищаемой цепи падает до 35-70 % от номинального значения.
Срабатывание происходит мгновенно, после чего автоматический выключатель невозможно перевести во включенное положение до тех, пока линейное напряжение защищаемой цепи не повысится до 85 %.
Минимальный расцепитель постоянно находится под напряжением защищаемой цепи и всегда успевает сработать до того, как будет предпринята попытка включения автоматического выключателя.
[Перевод Интент]
В низковольтных автоматических выключателеях минимальный расцепитель напряжения является дополнительной принадлежностью, которая встраивается в гнездо автоматического выключателя
Дополнительные (электрические) принадлежности, встраиваемые в специальные гнезда автоматического выключателя:
1 - Левое гнездо;
2 - Автоматический выключатель;
3 - Правое гнездо.
Рис. LS Industrial SystemsНедопустимые, нерекомендуемые
Тематики
- выключатель автоматический
- расцепитель, тепловое реле
Классификация
>>>EN
- low-voltage release
- under voltage release
- under voltage trip
- under voltage trip coil
- under voltage trip device
- under voltage trip unit
- undervoltage release
- undervoltage trip
- undervoltage trip device
- undervoltage trip unit
- UVT
FR
Русско-французский словарь нормативно-технической терминологии > минимальный расцепитель напряжения
-
11 делитель напряжения
делитель напряжения
-
[IEV number 312-02-32]
делитель напряжения
Преобразующее устройство, состоящее из плеч высокого и низкого напряжения, таких, что напряжение входа прикладывается ко всему устройству, а напряжение выхода снимается с плеча низкого напряжения. [МЭС 301-05-13, измененный]
Примечание
элементами обоих плеч обычно являются резисторы, конденсаторы или их комбинации, а делитель описывается типами и комбинацией используемых элементов (например, резистивный, емкостный или резистивно-емкостный).
[МЭК 60-2]
делитель напряжения
-
[Лугинский Я. Н. и др. Англо-русский словарь по электротехнике и электроэнергетике. 2-е издание - М.: РУССО, 1995 - 616 с.]EN
voltage divider
device comprising resistors, inductors, capacitors, transformer(s) or a combination of these components such that, between two points of the device, a desired fraction of the voltage applied to the device as a whole can be obtained
[IEV number 312-02-32]FR
diviseur de tension
dispositif constitué de résistances, d'inductances, de condensateurs, de transformateur(s) ou d'une combinaison de ces éléments telle que, entre deux points de ce dispositif, on obtient une fraction désirée de la tension appliquée au dispositif entier
[IEV number 312-02-32]Тематики
- измерение электр. величин в целом
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > делитель напряжения
-
12 устройство дифференциального тока, функционально зависимое от линейного напряжения
- dispositif différentiel dépendant fonctionnellement de la tension d'alimentation
устройство дифференциального тока, функционально зависимое от линейного напряжения
-
[IEV number 442-05-09]EN
residual current device functionally dependent on line voltage
residual current device for which the functions of detection, evaluation or interruption depend on the line voltage
[IEV number 442-05-09]FR
dispositif différentiel dépendant fonctionnellement de la tension d'alimentation
dispositif de coupure différentiel pour lequel les fonctions de détection, d'évaluation ou d'interruption dépendent de la tension d'alimentation
[IEV number 442-05-09]Тематики
- аппарат, изделие, устройство...
- электроустановки
Обобщающие термины
EN
DE
FR
- dispositif différentiel dépendant fonctionnellement de la tension d'alimentation
Русско-французский словарь нормативно-технической терминологии > устройство дифференциального тока, функционально зависимое от линейного напряжения
-
13 устройство дифференциального тока, функционально не зависимое от линейного напряжения
- dispositif différentiel fonctionnellement indépendant de la tension d'alimentation
устройство дифференциального тока, функционально не зависимое от линейного напряжения
-
[IEV number 442-05-08]EN
residual current device functionally independent of line voltage
residual current device for which the functions of detection, evaluation and interruption do not depend on the line voltage
[IEV number 442-05-08]FR
dispositif différentiel fonctionnellement indépendant de la tension d'alimentation
dispositif de coupure différentiel pour lequel les fonctions de détection, d'évaluation et d'interruption ne dépendent pas de la tension d'alimentation
[IEV number 442-05-08]Тематики
- аппарат, изделие, устройство...
- электроустановки
Обобщающие термины
EN
DE
- funktionell von der Netzspannung unabhängige Fehlerstrom-Schutzeinrichtung
FR
- dispositif différentiel fonctionnellement indépendant de la tension d'alimentation
Русско-французский словарь нормативно-технической терминологии > устройство дифференциального тока, функционально не зависимое от линейного напряжения
-
14 номинальное напряжение
номинальное напряжение
Напряжение, установленное изготовителем для прибора
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]
номинальное напряжение Uном, кВ
Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
[ ГОСТ Р 52726-2007]
номинальное напряжение
Un
Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
rated voltage
voltage assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]
rated voltage
quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
rated voltage
input or output supply voltage for which equipment is designed or specified
[IEC 88528-11, ed. 1.0 (2004-03)]
rated voltage
specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
[IEC 60349-1, ed. 1.0 (1999-11)]
rated voltage
the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
[IEC 62497-1, ed. 1.0 (2010-02)]
rated voltage
reference voltage for which the cable is designed, and which serves to define the electrical tests
NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
This condition applies both to the value Uo and to the value U.
In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
[IEC 60245-1, ed. 4.0 (2003-12)]
rated voltage
highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
[IEC 60800, ed. 3.0 (2009-07)]
rated voltage
the r.m.s. line-to-line voltage under rated conditions
Primary side of input transformer: ULN
Converter input: UVN
Converter output: UaN
Motor voltage: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
rated voltage
input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
[IEC 62040-1, ed. 1.0 (2008-06)]
nominal voltage, Un
voltage by which a system is designated or identified
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
tension assignée
tension attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]
tension nominale
tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
tension assignée
tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
[IEC 60349-1, ed. 1.0 (1999-11)]
tension assignée
valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
[IEC 62497-1, ed. 1.0 (2010-02)]
tension assignée
tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
[IEC 60245-1, ed. 4.0 (2003-12)]
tension assignée
tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
[IEC 60800, ed. 3.0 (2009-07)]
tension assignée
valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
Primaire du transformateur d’entrée: ULN
Entrée du convertisseur: UVN
Sortie du convertisseur: UaN
Moteur: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
tension assignée
tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
[IEC 62040-1, ed. 1.0 (2008-06)]
tension nominale, Un
tension par laquelle un réseau est désigné ou identifié
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- прибор электрический
- электроснабжение в целом
Синонимы
- Un
EN
FR
Русско-французский словарь нормативно-технической терминологии > номинальное напряжение
-
15 включающая способность (коммутационного аппарата)
включающая способность (коммутационного аппарата)
Значение ожидаемого тока включения, который способен включать коммутационный аппарат при установленном напряжении в предписанных условиях эксплуатации и поведения.
Примечание
Напряжение устанавливается и условия предписываются в стандарте на соответствующий аппарат.
МЭК 60050(441-17-09)
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
включающая способность коммутационного аппарата
Коммутационная способность коммутационного аппарата при включении цепи.
[ ГОСТ 17703-72]EN
making capacity (of a switching device or a fuse)
a value of prospective making current that a switching device is capable of making at a stated voltage under prescribed conditions of use and behaviour
NOTE – The voltage to be stated and the conditions to be prescribed are dealt with in the relevant specifications.
[IEV number 441-17-09]
[IEV number 442-01-48]FR
pouvoir de fermeture (d'un appareil de connexion)
une valeur du courant présumé établi qu'un appareil de connexion est capable d'établir sous une tension donnée et dans des conditions prescrites d'emploi et de comportement
NOTE – La tension à fixer et les conditions à prescrire sont précisées dans les spécifications individuelles
[IEV number 441-17-09]
[IEV number 442-01-48]
Тематики
- аппарат, изделие, устройство...
- выключатель автоматический
- выключатель, переключатель
- предохранитель
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > включающая способность (коммутационного аппарата)
-
16 отключающая способность (коммутационного аппарата или плавкого предохранителя)
отключающая способность (коммутационного аппарата или плавкого предохранителя)
Значение ожидаемого тока отключения, который способен отключать коммутационный аппарат или плавкий предохранитель при установленном напряжении в предписанных условиях эксплуатации и поведения.
Примечания
1 Напряжение устанавливается и условия предписываются в стандарте на соответствующий аппарат.
2 Для переменного тока это симметричное действующее значение периодической составляющей.
МЭК 60050(441-17-08)
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
отключающая способность (коммутационного аппарата или предохранителя)
Значение ожидаемого тока отключения, который коммутационный аппарат или предохранитель способен отключить при заданном напряжении в предписанных условиях применения и поведения.
Примечание - Для коммутационных аппаратов отключающая способность может быть определена в соответствии с видом тока, предусмотренного в предписанных условиях, например отключающая способность при отключении ненагруженной линии, отключающая способность при отключении ненагруженного кабеля, отключающая способность при отключении одиночной конденсаторной батареи и т. д
[ ГОСТ Р 52726-2007]
отключающая способность коммутационного аппарата
Коммутационная способность коммутационного аппарата при отключении цепи.
[ ГОСТ 17703-72]EN
breaking capacity (of a switching device or a fuse)
a value of prospective current that a switching device or a fuse is capable of breaking at a stated voltage under prescribed conditions of use and behaviour
NOTE 1 – The voltage to be stated and the conditions to be prescribed are dealt with in the relevant publications.
NOTE 2 – For switching devices, the breaking capacity may be termed according to the kind of current included in the prescribed conditions, e.g. line-charging breaking capacity, cable charging breaking capacity, single capacitor bank breaking capacity, etc.
[IEV number 441-17-08]
[IEV number 441-01-49]FR
pouvoir de coupure (d'un appareil de connexion ou d'un fusible)
une valeur de courant présumé qu'un appareil de connexion ou un fusible est capable d'interrompre sous une tension fixée dans des conditions prescrites d'emploi et de comportement
NOTE 1 – La tension à fixer et les conditions à prescrire sont précisées dans les publications particulières.
NOTE 2 – Pour les appareils de connexion, le pouvoir de coupure peut être dénommé suivant le type de courant intervenant dans les conditions prescrites, par exemple: pouvoir de coupure de lignes à vide, pouvoir de coupure de câbles à vide, pouvoir de coupure d'une batterie de condensateurs unique, etc.
[IEV number 441-17-08]
[IEV number 441-01-49]
Недопустимые, нерекомендуемые
Примечание(1)- Мнение автора карточкиТематики
- выключатель автоматический
- выключатель, переключатель
- высоковольтный аппарат, оборудование...
Синонимы
EN
- BC
- breaking capacity
- breaking capacity (of a switching device or a fuse)
- breaking current capacity
- IC
- interrupting capability
- interrupting capacity
- rupture capacity
- rupture rupturing capacity
DE
FR
Русско-французский словарь нормативно-технической терминологии > отключающая способность (коммутационного аппарата или плавкого предохранителя)
-
17 предельное наименьшее значение рабочего напряжения вспомогательного источника питания
предельное наименьшее значение рабочего напряжения вспомогательного источника питания
-
[IEV number 442-05-33]EN
limiting value of the operating voltage of the auxiliary source
minimum value of the voltage of the auxiliary source, at which the residual current device still operates under specified conditions in the case of decreasing voltage of the auxiliary source
[IEV number 442-05-33]FR
valeur limite de la tension de fonctionnement de la source auxiliaire
valeur minimale de la tension de la source auxiliaire pour laquelle le dispositif de coupure différentiel fonctionne encore dans des conditions spécifiées en cas de diminution de la tension de la source auxiliaire
[IEV number 442-05-33]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > предельное наименьшее значение рабочего напряжения вспомогательного источника питания
-
18 минимальное реле или минимальной расцепитель напряжения
минимальное реле или минимальной расцепитель напряжения
Реле или расцепитель, допускающие размыкание или замыкание контактного коммутационного аппарата с выдержкой времени или без нее, когда напряжение на выводах этого реле или расцепителя падает ниже заданной величины.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
under-voltage relay or release
relay or release which permits a mechanical switching device to open or close, with or without time-delay, when the voltage across the terminals of the relay or release falls below a predetermined value
[IEC 60947-1, ed. 5.0 (2007-06)]FR
relais ou déclencheur à minimum de tension
relais ou déclencheur qui permet l'ouverture ou la fermeture, avec ou sans retard, d'un appareil mécanique de connexion lorsque la tension aux bornes du relais ou du déclencheur tombe au-dessous d'une valeur prédéterminée
[IEC 60947-1, ed. 5.0 (2007-06)]Тематики
- выключатель автоматический
- расцепитель, тепловое реле
- реле электрическое
Классификация
>>>EN
FR
Русско-французский словарь нормативно-технической терминологии > минимальное реле или минимальной расцепитель напряжения
-
19 разъединитель
разъединитель
Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
Примечание.
1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.
Условное обозначение контакта разъединителя
[ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]
разъединитель
Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
Примечания
1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
[ ГОСТ Р 52726-2007]EN
disconnector
a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
[IEV number 441-14-05]
disconnector
IEV 441-14-05 is applicable with the following additional notes:
NOTE 1
"Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
"No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
NOTE 2
For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
[IEC 62271-102]FR
sectionneur
appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
[IEV number 441-14-05]Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:
- изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
- иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
- быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
- обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;
Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:- Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
- Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
- Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
- Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
- Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
- Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.
[ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]
Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
[ http://relay-protection.ru/content/view/46/8/1/1/]
Параллельные тексты EN-RU
b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
[IEC 60204-1-2006]
б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
[Перевод Интент]
Тематики
- высоковольтный аппарат, оборудование...
- релейная защита
- электротехника, основные понятия
Классификация
>>>EN
- disconnect
- disconnect device
- disconnect switch
- disconnecting device
- disconnecting switch
- disconnector
- DS
- isolating facility
- isolating switch
- isolator
- main disconnect device
DE
FR
Смотри также
Русско-французский словарь нормативно-технической терминологии > разъединитель
20 блокировка вилки
блокировка
Электрическое или механическое устройство, предохраняющее контакты вилки от попадания под напряжение при введении ее в штепсельную или переносную розетку и препятствующее выведению вилки, пока ее контакты находятся под напряжением, или обесточивающее контакты перед выведением.
[ ГОСТ Р 51323.1-99]
блокировка вилки
-
[IEV number 442-01-33]EN
interlock of a plug
a device, either electrical or mechanical, which prevents a plug from becoming live before it is in proper engagement with a socket-outlet or connector, and which either prevents the plug from being withdrawn while it is live or makes it dead before separation
[IEV number 442-01-33]FR
dispositif de verrouillage d'une fiche
dispositif, électrique ou mécanique, qui empêche la mise sous tension d'une fiche avant qu'elle ne soit suffisamment engagée dans un socle de prise de courant ou dans une prise mobile, et qui empêche l'extraction de la fiche tant qu'elle est sous tension ou qui la met hors tension avant la séparation
[IEV number 442-01-33]Тематики
Синонимы
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > блокировка вилки
Страницы- 1
- 2
См. также в других словарях:
Tension device — Устройство для регулирования натяжения (ленты), рулонный тормоз … Краткий толковый словарь по полиграфии
Tension headache — Classification and external resources ICD 10 G44.2 ICD 9 307.81 … Wikipedia
Tension — Ten sion, n. [L. tensio, from tendere, tensum, to stretch: cf. F. tension. See {Tense}, a.] 1. The act of stretching or straining; the state of being stretched or strained to stiffness; the state of being bent strained; as, the tension of the… … The Collaborative International Dictionary of English
Tension brace — Tension Ten sion, n. [L. tensio, from tendere, tensum, to stretch: cf. F. tension. See {Tense}, a.] 1. The act of stretching or straining; the state of being stretched or strained to stiffness; the state of being bent strained; as, the tension of … The Collaborative International Dictionary of English
Tension member — Tension Ten sion, n. [L. tensio, from tendere, tensum, to stretch: cf. F. tension. See {Tense}, a.] 1. The act of stretching or straining; the state of being stretched or strained to stiffness; the state of being bent strained; as, the tension of … The Collaborative International Dictionary of English
Tension rod — Tension Ten sion, n. [L. tensio, from tendere, tensum, to stretch: cf. F. tension. See {Tense}, a.] 1. The act of stretching or straining; the state of being stretched or strained to stiffness; the state of being bent strained; as, the tension of … The Collaborative International Dictionary of English
Tension arm — is a device used in magnetic tape recorders/reproducers to control the tension of the magnetic tape during machine operation. The recorders equipped with a tension arm can utilize more than one of them to control tape tension in different… … Wikipedia
tension — [ten′shən] n. [< MFr or L: MFr < L tensio < tensus: see TENSE1] 1. a tensing or being tensed 2. mental or nervous strain, often accompanied by muscular tautness 3. a state of strained relations; uneasiness due to mutual hostility 4. a… … English World dictionary
Automatic tension device — Автоматический регулятор натяжения (ленты) … Краткий толковый словарь по полиграфии
Paper tension device — Устройство для регулировки натяжения ленты … Краткий толковый словарь по полиграфии
Running belt tension device — Рулонный тормоз с движущимися лентами … Краткий толковый словарь по полиграфии
Перевод: с русского на французский
с французского на русский- С французского на:
- Русский
- С русского на:
- Все языки
- Английский
- Итальянский
- Немецкий
- Французский