  • 1 пуск переключением со звезды на треугольник

    1. démarrage étoile-triangle

     

    пуск переключением со звезды на треугольник
    -

    EN

    star-delta starting
    the process of starting a three-phase motor by connecting it to the supply with the primary winding initially connected in star, then reconnected in delta for the running condition
    [IEV number 411-52-16]

    FR

    démarrage étoile-triangle
    mode de démarrage d'un moteur triphasé à tension réduite, consistant à relier à la source à tension constante les enroulements statoriques, d'abord en couplage étoile, puis à passer au couplage triangle pour le fonctionnement normal
    [IEV number 411-52-16]

    0856

    Magnetic only circuit-breaker - Автоматический выключатель с электромагнитным расцепителем

    Y/Δ changeover node - Узел переключения со звезды на треугольник

    Contactor KL - Контактор KL

    Thermal relay - Тепловое реле

    Contactor KΔ - Контактор KΔ

    Contactor KY- Контактор KY

    Параллельные тексты EN-RU

    Star-delta Y/Δ starting

    Star-delta starting is the best known system and perhaps the commonest starting system at reduced voltage; it is used to start the motor reducing the mechanical stresses and limiting the current values during starting; on the other hand, it makes available a reduced inrush torque.

    This system can be used for motors with terminal box with 6 terminals and double supply voltage.

    It is particularly suitable for no-load starting or with low and constant load torque or lightly increasing load torque, such as in the case of fans or low power centrifugal pumps.

    Making reference to the diagram of Figure 6, the starting modality foresees the initial phase with star-connection of the windings to be realized through the closing of the circuit-breaker, of the line contactor KL and of the star contactor KY.

    After a suitable predetermined period of time, the opening of the contactor KY and the closing of KΔ allow switching to delta-connection, which is also the configuration of normal running position.
    [ABB]

    Пуск переключением со звезды на треугольник

    Пуск переключением со звезды на треугольник является самым известным способом и, возможно, самой распространенной схемой пуска на пониженном напряжении. С одной стороны, этот способ используется для снижения механических нагрузок и ограничения пускового тока, а с другой - обеспечивает уменьшение пускового момента.

    Такая возможность может быть реализована в двигателях с шестью зажимами в выводной коробке, что позволяет питать его от двух напряжений.

    Особенно этот способ подходит для ненагруженного пуска и пуска с низким постоянным или немного увеличивающимся вращающим моментом, например, для пуска вентиляторов или маломощных центробежных насосов.

    Схема пуска переключением со звезды на треугольник представлена на рисунке 6. В начальный момент пуска обмотки статора соединяют звездой путем замыкания контактов автоматического выключателя, линейного контактора KL и контактора KY со схемой "звезда".

    По истечении заданного времени контакты контактора KY размыкаются и замыкаются контакты контактора КΔ со схемой треугольник.
    В результате выполняется переключение обмоток статора со схемы «звезда» на схему «треугольник».
    Обе схемы соединения обмоток являются схемами нормального рабочего режим
    а.
    [Перевод Интент]

    Тематики

    Обобщающие термины

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > пуск переключением со звезды на треугольник

  • 2 прямой пуск вращающегося электродвигателя

    1. démarrage direct

     

    прямой пуск вращающегося электродвигателя
    Пуск вращающегося электродвигателя путем непосредственного подключения его к питающей сети.
    [ ГОСТ 27471-87]

    EN

    direct-on-line starting
    across-the-line starting (US)
    the process of starting a motor by connecting it directly to the supply at rated voltage
    [IEV number 411-52-15]

    FR

    démarrage direct
    mode de démarrage d'un moteur, consistant à lui appliquer directement sa pleine tension assignée
    [IEV number 411-52-15]

    0855
    Рис. ABB
    Схема прямого пуска электродвигателя

    Magnetic only circuit-breaker - Автоматический выключатель с электромагнитным расцепителем

    Contactor KL - Контактор KL

    Thermal relay - Тепловое реле

     

    Параллельные тексты EN-RU

    Direct-on-line starting

    Direct-on-line starting, which is often abbreviated as DOL, is perhaps the most traditional system and consists in connecting the motor directly to the supply network, thus carrying out starting at full voltage.

    Direct-on-line starting represents the simplest and the most economical system to start a squirrel-cage asynchronous motor and it is the most used.

    As represented in Figure 5, it provides the direct connection to the supply network and therefore starting is carried out at full voltage and with constant frequency, developing a high starting torque with very reduced acceleration times.

    The typical applications are relevant to small power motors also with full load starting.

    These advantages are linked to some problems such as, for example, the high inrush current, which - in the first instants - can reach values of about 10 to 12 times the rated current, then can decrease to about 6 to 8 times the rated current and can persist to reach the maximum torque speed.

    The effects of such currents can be identified with the high electro-dynamical stresses on the motor connection cables and could affect also the windings of the motor itself; besides, the high inrush torques can cause violent accelerations which stress the transmission components (belts and joints) generating distribution problems with a reduction in the mechanical life of these elements.

    Finally, also the possible electrical problems due to voltage drops on the supply line of the motor or of the connected equipment must be taken into consideration.
    [ABB]

    Прямой пуск

    Прямой пуск, который по-английски часто сокращенно обозначают как DOL, является, пожалуй наиболее распространенным способом пуска. Он заключается в непосредственном (т. е. прямом) подключении двигателя к питающей сети. Это означает, что пуск двигателя осуществляется при полном напряжении.

    Схема прямого пуска является наиболее простым, экономичным и чаще всего применяемым решением для электродвигателей с короткозамкнутым ротором.

    Схема прямого подключения к сети представлена на рисунке 5. Пуск осуществляется при полном напряжении и постоянной частоте сети. Электродвигатель развивает высокий пусковой момент при коротком времени разгона.

    Типичные области применения – маломощные электродвигатели, в том числе с пуском при полной нагрузке.

    Однако, наряду с преимуществами имеются и определенные недостатки, например, бросок пускового тока, достигающий в первоначальный момент 10…12-кратного значения от номинального тока электродвигателя. Затем ток двигателя уменьшается примерно до 6…8-кратного значения номинального тока и будет держаться на этом уровне до тех пор, пока скорость двигателя не достигнет максимального значения.

    Такое изменение тока оказывает значительное электродинамическое воздействие на кабель, подключенный к двигателю. Кроме того пусковой ток воздействует на обмотки двигателя. Высокий начальный пусковой момент может привести к значительному ускорению и следовательно к значительной нагрузке элементов привода (ремней, крепления узлов), что вызывает сокращение их срока службы.

    И, наконец, следует принять во внимание возможное возникновение проблем, связанных с падением напряжения в линии питания двигателя и подключенного к этой линии оборудования.
    [Перевод Интент]




     

    Тематики

    Синонимы

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > прямой пуск вращающегося электродвигателя

  • 3 разъединитель

    1. sectionneur

     

    разъединитель
    Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
    Примечание.
    1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
    Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.

    0043 Условное обозначение контакта разъединителя

    [ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]

    разъединитель
    Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
    Примечания
    1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
    2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
    3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
    4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
    [ ГОСТ Р 52726-2007]

    EN

    disconnector
    a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
    NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
    [IEV number 441-14-05]

    disconnector

    IEV 441-14-05 is applicable with the following additional notes:
    NOTE 1
    "Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
    "No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
    NOTE 2
    For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
    [IEC 62271-102]

    FR

    sectionneur
    appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
    NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
    [IEV number 441-14-05]

    Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:

    • изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
    • иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
    • быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
    • обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;

    [ ГОСТ Р МЭК 60204-1-2007]


    Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
    Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
    Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
    Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:

    1. Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
    2. Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
    3. Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
    4. Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
    5. Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
    6. Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.

    [ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]


    Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
    [ http://relay-protection.ru/content/view/46/8/1/1/]


    Параллельные тексты EN-RU

    b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
    [IEC 60204-1-2006]

    б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
    [Перевод Интент]

    Тематики

    • высоковольтный аппарат, оборудование...
    • релейная защита
    • электротехника, основные понятия

    Классификация

    >>>

    EN

    DE

    FR

    Смотри также

    Русско-французский словарь нормативно-технической терминологии > разъединитель

См. также в других словарях:

  • Load balancing (computing) — Load balancing is a computer networking methodology to distribute workload across multiple computers or a computer cluster, network links, central processing units, disk drives, or other resources, to achieve optimal resource utilization,… …   Wikipedia

  • Relay cylinder — In a variable expansion central valve engine, a small auxiliary engine for automatically adjusting the steam distribution to the load on the main engine. [Webster 1913 Suppl.] …   The Collaborative International Dictionary of English

  • Relay — This article is about the electrical component. For other uses, see Relay (disambiguation). Automotive style miniature relay, dust cover is taken off A relay is an electrically operated switch. Many relays use an electromagnet to operate a… …   Wikipedia

  • Load control switch — A load control switch is a remotely controlled relay that is placed on home appliances which use a lot of electricity, such as air conditioner units and electric water heaters. A load control switch consist of a communication module and the relay …   Wikipedia

  • Frame relay — In the context of computer networking, frame relay consists of an efficient data transmission technique used to send digital information. It is a message forwarding relay race like system in which data packets, called frames, are passed from one… …   Wikipedia

  • Dummy load — Cantenna dummy load suitable up to 30 MHz and up to 1 kW A dummy load is a device used to simulate an electrical load, usually for testing purposes. Contents 1 Radio …   Wikipedia

  • Solid state relay — A solid state relay (SSR) is an electronic switch, which, unlike an electromechanical relay, contains no moving parts. The types of SSR are photo coupled SSR, transformer coupled SSR, and hybrid SSR. A photo coupled SSR is controlled by a low… …   Wikipedia

  • Internet Relay Chat — IRC redirects here. For other uses, see IRC (disambiguation). For IRC channels dedicated to Wikipedia, see Wikipedia:IRC Internet Relay Chat (IRC) is a protocol for real time Internet text messaging (chat) or synchronous conferencing.[1] It is… …   Wikipedia

  • 2008 Summer Olympics torch relay — 2008 Summer Olympics Bid process Venues Marketing Concerns and controversies Torch relay (route) Opening ceremony (flag bearers) Medal table (medalists) Closing ceremony Event calendar …   Wikipedia

  • Protective relay — See also: Power system protection In electrical engineering, a protective relay is a complex electromechanical apparatus, often with more than one coil, designed to calculate operating conditions on an electrical circuit and trip circuit breakers …   Wikipedia

  • Control relay — A control relay is an electromechanical device which activates one or more switches according to the current through a coil not connected to the switches. The thyristor is a semiconductor device which carries out similar functions.A relay is… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»