-
1 serre-câble
кабельный анкер
Устройство, предназначенное для уменьшения натяжения проводников в местах присоединения их к зажимам или муфтам или для предотвращения отсоединения кабеля от оболочки.
[ ГОСТ Р МЭК 61084-2-2-2007]EN
cable anchorage
a system accessory used to relieve conductors from strain in terminals or terminations or to prevent a cable from becoming detached from an enclosure
[IEC 61084-2-2, ed. 1.0 (2003-05)]FR
serre-câble
accessoire du système destiné à soulager les conducteurs isolés des efforts au niveau des bornes ou terminaisons ou à empêcher un câble de se détacher d'une enveloppe
[IEC 61084-2-2, ed. 1.0 (2003-05)]Тематики
- изделие электромонтажное
- электропроводка, электромонтаж
EN
FR
кабельный зажим
Деталь или сборочная единица, предназначенная для закрепления кабеля или жгута проводов и обеспечивающая защиту хвостовиков электрического соединителя от механических усилий
[ ГОСТ 21962-76]EN
cable clamp
accessory or part of a component which grips the cable or wire to provide strain relief and absorb mechanical stress which would otherwise be transmitted to the termination
[IEV number 581-27-89]FR
serre-câble
accessoire ou partie de composant destiné à agripper le câble ou le fil, réduire les contraintes et absorber les efforts mécaniques qui, autrement, seraient transmis à la sortie
[IEV number 581-27-89]
Тематики
EN
DE
- Zugentlastungsklemme, f
FR
Франко-русский словарь нормативно-технической терминологии > serre-câble
-
2 rapport de pas
кратность шага скрутки
отношение шага скрутки к диаметру спирали образуемой одним из компонентов кабеля
Примечание. В зависимости от обстоятельств рассматриваемый диаметр является внутренним средним или наружным диаметром повива, в котором расположен компонент кабеля, образующий спираль
[IEV number 461-04-02]EN
lay ratio
ratio of the length of lay to diameter of the helix formed by one cable component
NOTE – Depending on the circumstances, the diameter to consider is either the internal diameter, or the mean diameter, or the external diameter of the layer in which the component is laid in the helix.
[IEV number 461-04-02]FR
rapport de pas
rapport entre le pas d'assemblage et le diamètre de l'hélice formée par un des constituants du câble
NOTE – Suivant le cas, le diamètre considéré est soit le diamètre intérieur, soit le diamètre moyen, soit le diamètre extérieur de la couche dont fait partie le constituant disposé en hélice.
[IEV number 461-04-02]Тематики
- кабели, провода...
EN
DE
- Verseilfaktor, m
FR
Франко-русский словарь нормативно-технической терминологии > rapport de pas
-
3 pas (d'assemblage)
шаг скрутки
длина одного полного витка спирали, образуемой вдоль продольной оси кабеля одним из его компонентов
[IEV number 461-04-01]EN
length of lay
axial length of one complete turn of the helix formed by one cable component
[IEV number 461-04-01]FR
pas (d'assemblage)
longueur, suivant l'axe du câble, d'un tour complet de l'hélice formée par un des constituants du câble
[IEV number 461-04-01]Тематики
- кабели, провода...
EN
DE
- Schlaglänge, f
FR
Франко-русский словарь нормативно-технической терминологии > pas (d'assemblage)
-
4 tension assignée
номинальное напряжение
Напряжение, установленное изготовителем для прибора
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]
номинальное напряжение Uном, кВ
Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
[ ГОСТ Р 52726-2007]
номинальное напряжение
Un
Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
rated voltage
voltage assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]
rated voltage
quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
rated voltage
input or output supply voltage for which equipment is designed or specified
[IEC 88528-11, ed. 1.0 (2004-03)]
rated voltage
specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
[IEC 60349-1, ed. 1.0 (1999-11)]
rated voltage
the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
[IEC 62497-1, ed. 1.0 (2010-02)]
rated voltage
reference voltage for which the cable is designed, and which serves to define the electrical tests
NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
This condition applies both to the value Uo and to the value U.
In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
[IEC 60245-1, ed. 4.0 (2003-12)]
rated voltage
highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
[IEC 60800, ed. 3.0 (2009-07)]
rated voltage
the r.m.s. line-to-line voltage under rated conditions
Primary side of input transformer: ULN
Converter input: UVN
Converter output: UaN
Motor voltage: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
rated voltage
input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
[IEC 62040-1, ed. 1.0 (2008-06)]
nominal voltage, Un
voltage by which a system is designated or identified
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
tension assignée
tension attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]
tension nominale
tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
tension assignée
tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
[IEC 60349-1, ed. 1.0 (1999-11)]
tension assignée
valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
[IEC 62497-1, ed. 1.0 (2010-02)]
tension assignée
tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
[IEC 60245-1, ed. 4.0 (2003-12)]
tension assignée
tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
[IEC 60800, ed. 3.0 (2009-07)]
tension assignée
valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
Primaire du transformateur d’entrée: ULN
Entrée du convertisseur: UVN
Sortie du convertisseur: UaN
Moteur: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
tension assignée
tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
[IEC 62040-1, ed. 1.0 (2008-06)]
tension nominale, Un
tension par laquelle un réseau est désigné ou identifié
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- прибор электрический
- электроснабжение в целом
Синонимы
- Un
EN
FR
Франко-русский словарь нормативно-технической терминологии > tension assignée
-
5 tension nominale
номинальное напряжение
Напряжение, установленное изготовителем для прибора
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]
номинальное напряжение Uном, кВ
Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
[ ГОСТ Р 52726-2007]
номинальное напряжение
Un
Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
rated voltage
voltage assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]
rated voltage
quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
rated voltage
input or output supply voltage for which equipment is designed or specified
[IEC 88528-11, ed. 1.0 (2004-03)]
rated voltage
specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
[IEC 60349-1, ed. 1.0 (1999-11)]
rated voltage
the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
[IEC 62497-1, ed. 1.0 (2010-02)]
rated voltage
reference voltage for which the cable is designed, and which serves to define the electrical tests
NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
This condition applies both to the value Uo and to the value U.
In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
[IEC 60245-1, ed. 4.0 (2003-12)]
rated voltage
highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
[IEC 60800, ed. 3.0 (2009-07)]
rated voltage
the r.m.s. line-to-line voltage under rated conditions
Primary side of input transformer: ULN
Converter input: UVN
Converter output: UaN
Motor voltage: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
rated voltage
input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
[IEC 62040-1, ed. 1.0 (2008-06)]
nominal voltage, Un
voltage by which a system is designated or identified
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
tension assignée
tension attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]
tension nominale
tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
tension assignée
tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
[IEC 60349-1, ed. 1.0 (1999-11)]
tension assignée
valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
[IEC 62497-1, ed. 1.0 (2010-02)]
tension assignée
tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
[IEC 60245-1, ed. 4.0 (2003-12)]
tension assignée
tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
[IEC 60800, ed. 3.0 (2009-07)]
tension assignée
valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
Primaire du transformateur d’entrée: ULN
Entrée du convertisseur: UVN
Sortie du convertisseur: UaN
Moteur: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
tension assignée
tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
[IEC 62040-1, ed. 1.0 (2008-06)]
tension nominale, Un
tension par laquelle un réseau est désigné ou identifié
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- прибор электрический
- электроснабжение в целом
Синонимы
- Un
EN
FR
номинальное напряжение конденсатора
Максимальное напряжение, при котором конденсатор может работать в течение минимальной наработки в условиях, указанных в нормативно-технической документации
[ ГОСТ 21415-75]
номинальное напряжение конденсатора
Действующее значение синусоидального переменного напряжения при номинальной частоте, на которое рассчитан конденсатор. Номинальное напряжение многофазного конденсатора - значение напряжения между выводами.
[ ГОСТ 1282-88]Тематики
- конденсаторы для повыш. коэф. мощности
- конденсаторы для электронной аппаратуры
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > tension nominale
-
6 Un
номинальное напряжение
Напряжение, установленное изготовителем для прибора
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]
номинальное напряжение Uном, кВ
Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
[ ГОСТ Р 52726-2007]
номинальное напряжение
Un
Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
rated voltage
voltage assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]
rated voltage
quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
rated voltage
input or output supply voltage for which equipment is designed or specified
[IEC 88528-11, ed. 1.0 (2004-03)]
rated voltage
specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
[IEC 60349-1, ed. 1.0 (1999-11)]
rated voltage
the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
[IEC 62497-1, ed. 1.0 (2010-02)]
rated voltage
reference voltage for which the cable is designed, and which serves to define the electrical tests
NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
This condition applies both to the value Uo and to the value U.
In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
[IEC 60245-1, ed. 4.0 (2003-12)]
rated voltage
highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
[IEC 60800, ed. 3.0 (2009-07)]
rated voltage
the r.m.s. line-to-line voltage under rated conditions
Primary side of input transformer: ULN
Converter input: UVN
Converter output: UaN
Motor voltage: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
rated voltage
input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
[IEC 62040-1, ed. 1.0 (2008-06)]
nominal voltage, Un
voltage by which a system is designated or identified
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
tension assignée
tension attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]
tension nominale
tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
tension assignée
tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
[IEC 60349-1, ed. 1.0 (1999-11)]
tension assignée
valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
[IEC 62497-1, ed. 1.0 (2010-02)]
tension assignée
tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
[IEC 60245-1, ed. 4.0 (2003-12)]
tension assignée
tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
[IEC 60800, ed. 3.0 (2009-07)]
tension assignée
valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
Primaire du transformateur d’entrée: ULN
Entrée du convertisseur: UVN
Sortie du convertisseur: UaN
Moteur: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
tension assignée
tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
[IEC 62040-1, ed. 1.0 (2008-06)]
tension nominale, Un
tension par laquelle un réseau est désigné ou identifié
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- прибор электрический
- электроснабжение в целом
Синонимы
- Un
EN
FR
Франко-русский словарь нормативно-технической терминологии > Un
-
7 sens d'assemblage
направление скрутки
направление вращения компонента кабеля относительно продольной оси кабеля
Примечание. Направление повива считается правым, если видимая часть спирали вместе с двумя сечениями, ограничивающими ее, образуют форму буквы Z и левым если она образует форму буквы S
[IEV number 461-04-03]EN
direction of lay
direction of rotation of a component of a cable in relation to the longitudinal axis of the cable
NOTE – The lay is said to be right-hand when the visible portion of the helix, together with the two cross-sections limiting it, form the shape of a letter Z, and left-hand when they form the shape of a letter S.
[IEV number 461-04-03]FR
sens d'assemblage
sens de rotation d'un composant du câble par rapport à l'axe du câble
NOTE – Le pas est dit à droite lorsque la partie visible de l'hélice forme, avec les deux sections droites qui la limitent, la lettre Z, et à gauche si la figure formée rappelle la lettre S.
[IEV number 461-04-03]Тематики
- кабели, провода...
EN
DE
- Schlagrichtung, f
FR
Франко-русский словарь нормативно-технической терминологии > sens d'assemblage
-
8 borne
вывод
Проводящая часть аппарата, предназначенная для электрического соединения с внешними цепями.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
вывод
Часть выключателя с контактами, служащими для присоединения к выключателю проводников внешней цепи
[ ГОСТ Р 52565-2006]
вывод электротехнического изделия (устройства)
Ндп. клемма
Часть электротехнического изделия (устройства), предназначенная для электрического соединения его с другими изделиями (устройствами).
[ ГОСТ 18311-80]
вывод (трансформатора)
Токоведущая часть, предназначенная для присоединения обмотки к внешним проводникам
[ ГОСТ 30830-2002]
вывод
Точка электрической цепи, предназначенная для выполнения соединений с другой электрической цепью.
[ ГОСТ Р 52002-2003]
вывод
-
[IEV number 151-12-12]EN
terminal
component provided for the connection of a device to external conductors.
[IEC 62271-100, ed. 2.0 (2008-04)]
terminal
the conductive part of one pole, composed of one or more clamping unit(s) and insulation if necessary
[IEC 60669-1, ed. 3.0 (1998-02)]
terminal
conductive part of a device, electric circuit or electric network, provided for connecting that device, electric circuit or electric network to one or more external conductors
NOTE – The term "terminal" is also used for a connection point in circuit theory.
Source: see IEC 60050-131
[IEV number 151-12-12]FR
borne
composant destiné à raccorder un disjoncteur à des conducteurs extérieurs.
[IEC 62271-100, ed. 2.0 (2008-04)]
borne
partie unipolaire conductrice composée d'un ou plusieurs organes de serrage, isolée si nécessaire
[IEC 60669-1, ed. 3.0 (1998-02)]
borne, f
partie conductrice d'un dispositif, d'un circuit électrique ou d'un réseau électrique, destinée à le connecter à un ou plusieurs conducteurs extérieurs
NOTE – Le terme "borne" désigne aussi un point de connexion en théorie des circuits.
Source: voir la CEI 60050-131
[IEV number 151-12-12]Недопустимые, нерекомендуемые
Тематики
- вывод, зажим электрический
Классификация
>>>Синонимы
EN
DE
FR
вывод полупроводникового прибора
вывод
Элемент конструкции корпуса полупроводникового прибора, необходимый для соединения соответствующего электрода с внешней электрической цепью.
[ ГОСТ 15133-77]Тематики
Синонимы
EN
DE
FR
1. Часть вывода электрического изделия, аппарата или устройства
зажим
Одна или несколько частей вывода, необходимые для механического крепления и электрического присоединения одного или нескольких проводников
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
зажим
Проводящая часть одного полюса, состоящая из одного или более зажимного устройства и изолированная, если необходимо.
[ ГОСТ Р 51324.1—2005 (МЭК 60669-1-2000)]
контактный зажим
-
[Интент]
зажим
—
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]EN
terminal
conductive part of a device provided for electrical connection to external circuits
[IEC 60947-1, ed. 5.0 (2007-06)]FR
borne
partie conductrice d'un appareil prévue pour le raccordement électrique à des circuits extérieurs
[IEC 60947-1, ed. 5.0 (2007-06)]Любое электрическое изделие, аппарат или устройство, будь то резистор, трансформатор, выключатель и т. п., имеет выводы, через которые осуществляется соединение с другими изделиями, аппаратами или устройствами. Соединение может быть неразборным (например, выполненное пайкой), разъемным (например, состоящим из вилки и розетки) и разборным. В последнем случае вывод оснащен зажимом, который служит для механического крепления и электрического присоединения одного или нескольких проводников.
[Интент]-
5.4.49. Напряжение на зажимах электродвигателей и в цепях управления ими при всех режимах работы электрооборудования крана должно быть не ниже 85% номинального. [ПУЭ]
- 6.2.15. В щитках без отключающего аппарата на вводе должны быть зажимы для присоединения проводников питающей цепи. [ ГОСТ Р 51778-2001]
-
6.3.1. В щитках должны быть предусмотрены следующие виды контактных зажимов (далее — зажимы) для присоединения внешних проводников:
-
вводные зажимы для присоединения фазных проводников питающей цепи (при отсутствии аппарата на вводе щитка);
-
зажимы для присоединения нулевых рабочих проводников N питающей и групповых цепей;
-
зажимы для присоединения нулевых защитных проводников РЕ или PEN-проводников питающей цепи и проводников РЕ групповых цепей.
[ ГОСТ Р 51778-2001]
-
вводные зажимы для присоединения фазных проводников питающей цепи (при отсутствии аппарата на вводе щитка);
-
Способ крепления проводов к зажимам должен обеспечивать надежный контакт, чтобы не возникало опасности ослабления соединения или чрезмерного нагрева. [ ГОСТ Р МЭК 61038-2001]
-
В некоторых случаях, например при ослаблении контакта в зажимах, недостаточном механическом давлении или при неправильном монтаже в соединениях, может выделяться большое количество теплоты, что также зависит от конструкции соединений и значения проходящего через них тока. [ ГОСТ 27924-88( МЭК 695-2-3-84)]
Параллельные тексты EN-RU
There is a wide range of cable terminal solutions for 1,5 – 95mm² cables
[ABB]Контактные зажимы допускают присоединение кабелей сечением 1,5…95 мм2.
[Перевод Интент]
2. Отдельное устройство (приспособление) для механического крепления и электрического присоединения проводника или его экранирующей оплетки, например:

Рис. Phoenix Contact
Рис. Phoenix ContactНедопустимые, нерекомендуемые
Тематики
- вывод, зажим электрический
Классификация
>>>Обобщающие термины
Действия
Синонимы
Сопутствующие термины
EN
- binder
- binding post
- clamp
- clamp-type terminal
- cleat
- clip
- connecting terminal
- connection terminal
- connection terminal block
- dog
- ear
- electrical connection
- fixture
- grip
- jack
- mechanical lug
- post
- retaining clip
- staple
- terminal
- terminal clamp
- terminal point
FR
тумба
Небольшой каменный, бетонный или чугунный столбик для ограждения тротуаров или установки дорожного знака
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]Тематики
- город, населенный пункт
Синонимы
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > borne
-
9 dispositif de montage d'appareil
деталь для установки аппаратов
Компонент системы, применяемый для установки электрических аппаратов и электроустановочных изделий (выключателей, автоматических выключателей, электрических и телефонных розеток и др.) на прямых секциях коробов или специальных коробов.
[ ГОСТ Р МЭК 61084-1 2007]
деталь для установки аппаратов
-
[IEV number 442-02-41]EN
apparatus mounting device
in a cable trunking or ducting system, any component used to incorporate electrical apparatus (switches, socket outlets, circuit-breakers, telephone outlets etc.) added to a trunking or ducting length
[IEV number 442-02-41]FR
dispositif de montage d'appareil
dans un système de goulottes ou de conduits profilés, composant destiné à incorporer de l'appareillage électrique (interrupteurs, socles de prises de courant, disjoncteurs, prises de téléphone, etc.) ajouté à une longueur de goulotte ou de profilé
[IEV number 442-02-41]Тематики
- изделие электромонтажное
- электропроводка, электромонтаж
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > dispositif de montage d'appareil
-
10 (longueur de) goulotte
прямая секция кабельного короба
Основной компонент системы кабельных коробов, состоящий из основания (корпуса) со съемной или открывающейся крышкой
[ ГОСТ Р МЭК 61084-1 2007]
прямая секция
Для прямолинейных участков электропроводки без ответвлений и для прямолинейных участков электропроводки с устройствами для ответвлений одиночными кабелями
[ ГОСТ 20803-81]
прямая секция кабельного короба
-
[IEV number 442-02-37]EN
trunking length
the main component of a cable trunking system comprising a base with a removable cover
[IEV number 442-02-37]FR
(longueur de) goulotte
élément principal d'un système de goulottes constitué d'un fond avec un couvercle amovible
[IEV number 442-02-37]
Прямая секция кабельного короба
[ http://mks.montak.ru/catalog/182/232]Тематики
- изделие электромонтажное
- электропроводка, электромонтаж
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > (longueur de) goulotte
См. также в других словарях:
Component video — This article is about analog component video: for the processing of color components in digital video, see digital video, Chroma subsampling and YCbCr Not to be confused with Composite video. Three cables, each with RCA plugs at both ends, are… … Wikipedia
Electronic component — Various components An electronic component is a basic electronic element and may be available in a discrete form having two or more electrical terminals (or leads). These are intended to be connected together, usually by soldering to a printed… … Wikipedia
Umbilical cable — An umbilical cable or umbilical is a cable which supplies required consumables to an apparatus. It is named for its similar function to an umbilical cord. An umbilical can supply power to a remote electrical device or a more elaborate design can… … Wikipedia
Coaxial cable — RG 59 flexible coaxial cable composed of: A: outer plastic sheath B: woven copper shield C: inner dielectric insulator D: copper core Coaxial cable, or coax, has an inner conductor surrounded by a flexible, tubular insulating layer, surrounded by … Wikipedia
Audio multicore cable — An audio multicore cable, or most commonly known as a snake is a compact cable, typically about the diameter of a coin, used in the audio recording and entertainment fields, which contains typically 4 64 individual shielded pair microphone cables … Wikipedia
National Cable & Telecommunications Association v. Brand X Internet Services — Supreme Court of the United States … Wikipedia
LS Cable — Infobox Company company type = Public company name = LS Cable Co., Ltd company company slogan = Your No.1 Creative Partner foundation = 1962, Established 2003 location = Gangnam gu, South Korea United States Locations: Atlanta, Georgia Englewood… … Wikipedia
Multicore cable — A multicore cable is a generic term for an electrical cable that has multiple cores made of copper wire. The term is normally only used in relation to a cable that has more cores than commonly encountered. For example, a four core mains cable is… … Wikipedia
Distributed Component Object Model — (DCOM), en español Modelo de Objetos de Componentes Distribuidos, es una tecnología propietaria de Microsoft para desarrollar componentes software distribuidos sobre varios ordenadores y que se comunican entre sí. Extiende el modelo COM de… … Wikipedia Español
Xbox 360 accessories — The Xbox 360 game console, developed by Microsoft, features a number of first party and third party accessories. Contents 1 Game Controllers/Gamepads 1.1 Xbox 360 controllers 1.1.1 Windows compatibility … Wikipedia
History of video game consoles (seventh generation) — Part of a series on … Wikipedia