-
1 supporter
Helfer, Unterstützer, UnterstützungDeutsch-Russische Wörterbuch der Redewendungen mit Adjektiven und Partizipien > supporter
-
2 Leistungsschalter
автоматический выключатель
Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
(МЭС 441-14-20)
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
автоматический выключатель
-
[IEV number 442-05-01]EN
circuit breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
circuit breaker
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
[National Electrical Cod]FR
disjoncteur
1) Должно быть контактный коммутационный аппарат
appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
[Интент]КЛАССИФИКАЦИЯ
- По роду тока
- По напряжению
- По числу полюсов
- По виду корпуса
- По месту установки
- По изолирующей среде
- По установленным расцепителям
- По дополнительным защитам
- По назначению
- По категории применения
- По виду привода взвода пружины
- По выполняемой функции
-
По влиянию монтажного положения
Автоматические выключатели ABB Модульные автоматические выключатели
1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).
[Интент]Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
[Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Электромагнитный расцепитель;
5 - Сердечник
6 - Катушка
7 - Контактные зажимы автоматического выключателя
На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).
Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Тепловой расцепитель
5 - Биметаллическая пластина
6 - Нагревательный элемент
7 - Контактные зажимы автоматического выключателя
[Интент]Недопустимые, нерекомендуемые
Тематики
Классификация
>>>Обобщающие термины
Действия
- включение автоматического выключателя
- оперирование автоматического выключателя
- отключение автоматического выключателя
- срабатывание автоматического выключателя
EN
- auto-cutout
- automatic circuit breaker
- automatic cutout
- automatic switch
- breaker
- CB
- circuit breaker
- circuit-breaker
- cutout
DE
FR
Смотри также
силовой выключатель
-
[Интент]EN
circuit-breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit
[IEV ref 441-14-20]FR
disjoncteur
appareil mécanique de connexion capable d'établir, de supporter et d'interrompre des courants dans les conditions normales du circuit, ainsi que d'établir, de supporter pendant une durée spécifiée et d'interrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit
[IEV ref 441-14-20]
Рис. Siemens
Силовой ( баковый элегазовый) выключатель 3AP1 DT
Рис. Siemens
Силовой (колонковый элегазовый) выключательТематики
- высоковольтный аппарат, оборудование...
- комплектное распред. устройство (КРУ)
EN
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Leistungsschalter
3 Selbstschalter
автоматический выключатель
Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
(МЭС 441-14-20)
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
автоматический выключатель
-
[IEV number 442-05-01]EN
circuit breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
circuit breaker
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
[National Electrical Cod]FR
disjoncteur
1) Должно быть контактный коммутационный аппарат
appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
[Интент]КЛАССИФИКАЦИЯ
- По роду тока
- По напряжению
- По числу полюсов
- По виду корпуса
- По месту установки
- По изолирующей среде
- По установленным расцепителям
- По дополнительным защитам
- По назначению
- По категории применения
- По виду привода взвода пружины
- По выполняемой функции
-
По влиянию монтажного положения
Автоматические выключатели ABB Модульные автоматические выключатели
1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).
[Интент]Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
[Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Электромагнитный расцепитель;
5 - Сердечник
6 - Катушка
7 - Контактные зажимы автоматического выключателя
На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).
Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Тепловой расцепитель
5 - Биметаллическая пластина
6 - Нагревательный элемент
7 - Контактные зажимы автоматического выключателя
[Интент]Недопустимые, нерекомендуемые
Тематики
Классификация
>>>Обобщающие термины
Действия
- включение автоматического выключателя
- оперирование автоматического выключателя
- отключение автоматического выключателя
- срабатывание автоматического выключателя
EN
- auto-cutout
- automatic circuit breaker
- automatic cutout
- automatic switch
- breaker
- CB
- circuit breaker
- circuit-breaker
- cutout
DE
FR
Смотри также
Немецко-русский словарь нормативно-технической терминологии > Selbstschalter
4 Lastschalter
выключатель (контактный)
Контактный коммутационный аппарат, способный включать, проводить и отключать токи в нормальных условиях, в том числе при оговоренных рабочих перегрузках, а также в течение установленного времени проводить ток в оговоренных аномальных условиях, например при коротком замыкании.
МЭК 60050(441-14-10)
Примечание. Выключатель может быть способен включать, но не отключать ток короткого замыкания.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
(mechanical) switch
a mechanical switching device capable of making, carrying and breaking currents under normal circuit conditions which may include specified operating overload conditions and also carrying for a specified time currents under specified abnormal circuit conditions such as those of short circuit
NOTE – A switch may be capable of making but not breaking short-circuit currents.
[IEV number 441-14-10]FR
interrupteur (mécanique)
appareil mécanique de connexion capable d'établir, de supporter et d'interrompre des courants dans les conditions normales du circuit y compris éventuellement les conditions spécifiées de surcharge en service, ainsi que de supporter pendant une durée spécifiée des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit
NOTE – Un interrupteur peut être capable d'établir des courants de court-circuit mais n'est pas capable de les couper
[IEV number 441-14-10]Недопустимые, нерекомендуемые
Тематики
- выключатель, переключатель
EN
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Lastschalter
5 Hauptkontakt
главный контакт
Контакт, входящий в главную цепь контактного коммутационного аппарата и предназначенный для проведения в замкнутом положении тока главной цепи.
МЭК 60050(441-15-07).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
main contact
a contact included in the main circuit of a mechanical switching device, intended to carry, in the closed position, the current of the main circuit
[IEV number 441-15-07 ]FR
contact principal
contact inséré dans le circuit principal d'un appareil mécanique de connexion, prévu pour supporter, dans la position de fermeture, le courant du circuit principal
[IEV number 441-15-07 ]Недопустимые, нерекомендуемые
Примечание(1)- Мнение автора карточкиТематики
- выключатель автоматический
- выключатель, переключатель
EN
DE
FR
главный контакт аппарата
Коммутирующий контакт аппарата, включенный в его главную цепь
[ ГОСТ 17703-72]
главный контакт аппарата
Контакт, входящий в главную цепь контактного коммутационного аппарата и предназначенный для проведения в замкнутом положении тока главной цепи.
МЭК 60050(441-15-07).
ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99EN
main contact
a contact included in the main circuit of a mechanical switching device, intended to carry, in the closed position, the current of the main circuit
[IEV number 441-15-07]FR
contact principal
contact inséré dans le circuit principal d'un appareil mécanique de connexion, prévu pour supporter, dans la position de fermeture, le courant du circuit principal
[IEV number 441-15-07]Недопустимые, нерекомендуемые
Примечание(1)- Мнение автора карточкиТематики
- аппарат, изделие, устройство...
- контакт
EN
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Hauptkontakt
6 Trennschalter
разъединитель
Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
Примечание.
1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.
Условное обозначение контакта разъединителя
[ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]
разъединитель
Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
Примечания
1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
[ ГОСТ Р 52726-2007]EN
disconnector
a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
[IEV number 441-14-05]
disconnector
IEV 441-14-05 is applicable with the following additional notes:
NOTE 1
"Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
"No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
NOTE 2
For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
[IEC 62271-102]FR
sectionneur
appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
[IEV number 441-14-05]Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:
- изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
- иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
- быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
- обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;
Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:- Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
- Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
- Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
- Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
- Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
- Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.
[ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]
Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
[ http://relay-protection.ru/content/view/46/8/1/1/]
Параллельные тексты EN-RU
b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
[IEC 60204-1-2006]
б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
[Перевод Интент]
Тематики
- высоковольтный аппарат, оборудование...
- релейная защита
- электротехника, основные понятия
Классификация
>>>EN
- disconnect
- disconnect device
- disconnect switch
- disconnecting device
- disconnecting switch
- disconnector
- DS
- isolating facility
- isolating switch
- isolator
- main disconnect device
DE
FR
Смотри также
Немецко-русский словарь нормативно-технической терминологии > Trennschalter
7 Nichtauslösestrom (eines Überlastauslösers)
условный ток нерасцепления Int
Установленное значение тока, который автоматический выключатель для электрооборудования способен проводить заданное (условное) время без расцепления.
[ ГОСТ Р 50031-99( МЭК 60934-93)]
условный ток нерасцепления (максимального реле или расцепителя тока)
Установленное значение тока, который реле или расцепитель способны проводить, не срабатывая, в течение заданного (условного) времени.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
conventional non-tripping current
a specified value of current which the circuit-breaker is capable of carrying for a specified time designated as conventional time, without tripping
[IEV number 442-05-54]
conventional non-tripping current (of an over-current release)
a specified value of current which the release can carry for a specified time (conventional time) without operating
[IEV number 441-17-22]FR
courant conventionnel de non-déclenchement
valeur spécifiée du courant que le disjoncteur peut supporter sans déclencher pendant un temps spécifié appelé temps conventionnel
[IEV number 442-05-54]
courant conventionnel de non-déclenchement (d'un déclencheur à maximum de courant)
valeur spécifiée de courant que peut supporter un déclencheur pendant une durée spécifiée (durée conventionnelle) sans fonctionner
[IEV number 441-17-22]Тематики
Синонимы
EN
DE
- Nichtauslösestrom (eines Überlastauslösers)
- vereinbarte Nichtauslösestromstärke
- vereinbarter Nichtauslösestrom
FR
Немецко-русский словарь нормативно-технической терминологии > Nichtauslösestrom (eines Überlastauslösers)
8 vereinbarte Nichtauslösestromstärke
условный ток нерасцепления Int
Установленное значение тока, который автоматический выключатель для электрооборудования способен проводить заданное (условное) время без расцепления.
[ ГОСТ Р 50031-99( МЭК 60934-93)]
условный ток нерасцепления (максимального реле или расцепителя тока)
Установленное значение тока, который реле или расцепитель способны проводить, не срабатывая, в течение заданного (условного) времени.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
conventional non-tripping current
a specified value of current which the circuit-breaker is capable of carrying for a specified time designated as conventional time, without tripping
[IEV number 442-05-54]
conventional non-tripping current (of an over-current release)
a specified value of current which the release can carry for a specified time (conventional time) without operating
[IEV number 441-17-22]FR
courant conventionnel de non-déclenchement
valeur spécifiée du courant que le disjoncteur peut supporter sans déclencher pendant un temps spécifié appelé temps conventionnel
[IEV number 442-05-54]
courant conventionnel de non-déclenchement (d'un déclencheur à maximum de courant)
valeur spécifiée de courant que peut supporter un déclencheur pendant une durée spécifiée (durée conventionnelle) sans fonctionner
[IEV number 441-17-22]Тематики
Синонимы
EN
DE
- Nichtauslösestrom (eines Überlastauslösers)
- vereinbarte Nichtauslösestromstärke
- vereinbarter Nichtauslösestrom
FR
Немецко-русский словарь нормативно-технической терминологии > vereinbarte Nichtauslösestromstärke
9 vereinbarter Nichtauslösestrom
условный ток нерасцепления Int
Установленное значение тока, который автоматический выключатель для электрооборудования способен проводить заданное (условное) время без расцепления.
[ ГОСТ Р 50031-99( МЭК 60934-93)]
условный ток нерасцепления (максимального реле или расцепителя тока)
Установленное значение тока, который реле или расцепитель способны проводить, не срабатывая, в течение заданного (условного) времени.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
conventional non-tripping current
a specified value of current which the circuit-breaker is capable of carrying for a specified time designated as conventional time, without tripping
[IEV number 442-05-54]
conventional non-tripping current (of an over-current release)
a specified value of current which the release can carry for a specified time (conventional time) without operating
[IEV number 441-17-22]FR
courant conventionnel de non-déclenchement
valeur spécifiée du courant que le disjoncteur peut supporter sans déclencher pendant un temps spécifié appelé temps conventionnel
[IEV number 442-05-54]
courant conventionnel de non-déclenchement (d'un déclencheur à maximum de courant)
valeur spécifiée de courant que peut supporter un déclencheur pendant une durée spécifiée (durée conventionnelle) sans fonctionner
[IEV number 441-17-22]Тематики
Синонимы
EN
DE
- Nichtauslösestrom (eines Überlastauslösers)
- vereinbarte Nichtauslösestromstärke
- vereinbarter Nichtauslösestrom
FR
Немецко-русский словарь нормативно-технической терминологии > vereinbarter Nichtauslösestrom
10 Büronaffel
персона, которая проводит свою жизнь между компьютерными дискетами, горами актов и делich wird bestimmt nie so ‚n Büronaffel wie meine Supporter (спонсоры= родители, родственники, дающие деньги). Guck die die Büronaffels an, wie sie zur Mittagspause in die Kantine wuseln!11 gaga
meschugge, сумасшедший (прежде всего о Supporter и Brüssel-Schweine [EUPolitiker])bist du gaga, oder wa?12 Geldigel
m, -s, =отриц. 1 «денежная» персона; персона с большими деньгами в кошельке;2 скупердяйIch will nie so ‚n Geldigel werden. Meine Supporter sind echt die totalen Geldigel13 Geppi
[от (возможно) истории Уолта Диснея «Die Jagd nach dem Geppi»]1 обыватель, мещанинSo ’n Geppi wie mein Supporter möchte ich nie werden;2 молодой олень, самец косулиGuck dir die komischen Geppis an, wie sie sich jeden Morgen in die Straßenbahn quetschen.14 Häuptling
m, -s, -e[вождь, главарь]шериф, босс, шеф:Bist du hier der Häuptling, wa? Deine Supporter lassen den Häuptling ja voll raushängen!15 kalt stellen
вышвырнуть, внезапно уволитьJetzt ist’s aus mit den Minunnis, weil sie meinen Supporter kalt gestellt haben, die Slobbies!16 Teller
m, -s[1 тарелка; 2 круглая, плоская часть проигрывателя, на которой лежит пластинка]1 в выражении am Teller drehen – сдавать (о нервах), терять головуich dreh` gleich am Teller!;2 в выражении nichts mehr vom Teller ziehen – быть выгоревшим, измученным, конченымDer Supporter zieht echt nix mehr vom Teller;3 в выражении einen leeren Teller haben – обанкротиться, вылететь в трубуIch hab heute schon wieder ’nen leeren Teller;4 в выражении jemanden vom Teller ziehen – кого-то доконатьLass dich blöß nicht vom Teller (rand) ziehen! ;5 в выражении voller Teller – богатый, очень хороший17 Zuchtkarpfen
[букв. карп, выведенный в пруду]сниж 1 обыватель, мещанинMein Supporter ist ’n totaler Zuchtkarpfen; Die Fliesenleger sind für mich alles Zuchtkarpfen;2 персона, которая во всем принимает участие, плывет по течению:Ich spiel hier doch nicht euren dämlichen Zuchtkarpfen!18 Kurzschlußein- und -ausschaltvermögen
включающая и отключающая способность при коротком замыкании
-
[IEV number 442-05-48]EN
short-circuit (making and breaking) capacity
the alternating component of the prospective current, expressed by its rms value, which the circuit-breaker is designed to make, to carry for its opening time and to break under specified conditions
[IEV number 442-05-48]FR
pouvoir de coupure (et de fermeture) en court-circuit
composante alternative du courant présumé, exprimée en valeur efficace, que le disjoncteur, par conception, peut établir, peut supporter pendant son temps d'ouverture et peut interrompre dans des conditions spécifiées
[IEV number 442-05-48]EN
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Kurzschlußein- und -ausschaltvermögen
19 Fehlerstromeinschalt- und -ausschaltvermögen
дифференциальная включающая и отключающая способность
-
[IEV number 442-05-27]EN
residual making and breaking capacity
a value of the alternating component of a residual prospective current which a residual current device can make, carry for its opening time and break under specified conditions of use and behaviour
[IEV number 442-05-27]FR
pouvoir de fermeture et de coupure différentiel
valeur de la composante alternative du courant différentiel présumé qu'un dispositif de coupure différentiel est capable d'établir, de supporter pendant son temps de déclenchement et d'interrompre dans des conditions prescrites d'emploi et de comportement
[IEV number 442-05-27]Тематики
- электротехника, основные понятия
EN
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Fehlerstromeinschalt- und -ausschaltvermögen
20 Erdungsschalter
заземлитель
Контактный коммутационный аппарат, используемый для заземления частей цепи, способный выдерживать в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание, но не предусмотренный для проведения тока при нормальных условиях в цепи.
Примечания
1 Заземлитель может обладать включающей способностью при коротком замыкании.
2 Заземлитель на номинальное напряжение 110 кВ и выше может отключать (коммутировать) и проводить наведенные токи.
[ ГОСТ Р 52726-2007]
выключатель заземления
Механический 1) коммутационный аппарат для заземления частей электрической цепи, способный выдерживать электрические токи заданной продолжительности при ненормальных режимах, например при коротких замыканиях, но не предназначенный для пропускания электрического тока в нормальных режимах работы электрической цепи.
Примечание - Выключатель может быть стойким к токам короткого замыкания.
[ ГОСТ Р МЭК 60050-195-2005]EN
earthing switch
mechanical switching device for earthing parts of an electric circuit, capable of withstanding for a specified duration electric currents under abnormal conditions such as those of short-circuit, but not required to carry electric current under normal conditions of the electric circuit
NOTE – An earthing switch can have a short circuit making capacity.
Source: 441-14-11 MOD, 605-02-43 MOD
[IEV number 195-02-34]FR
connecteur de terre
appareil mécanique de connexion utilisé pour mettre à la terre des parties d'un circuit électrique, capable de supporter, pendant une durée spécifiée, des courants dans des conditions anormales telles que celles de court-circuit, mais non prévu pour transporter le courant électrique dans les conditions normales du circuit électrique
NOTE – Un connecteur de terre peut avoir un pouvoir de fermeture en court circuit.
Source: 441-14-11 MOD, 605-02-43 MOD
[IEV number 195-02-34]1) Должно быть контактный
[Интент]Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- заземление
- электробезопасность
Синонимы
EN
DE
FR
переключатель грозовой
Переключатель для заземления наружной антенны путём переключения её на заземлитель с целью защиты радиотелевизионной аппаратуры от грозовых разрядов
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]EN
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Erdungsschalter
Страницы- 1
- 2
См. также в других словарях:
supporter — Supporter. v. a. Porter, soustenir. Ces piliers, ces colomnes supportent toute cette maison, toute cette galerie, tout ce bastiment, toute la voute. Supporter, signifie fig. Favoriser. appuyer. Ce grand Seigneur, ce Ministre supporte, soustient… … Dictionnaire de l'Académie française
Supporter — Sup*port er, n. 1. One who, or that which, supports; as, oxygen is a supporter of life. [1913 Webster] The sockets and supporters of flowers are figured. Bacon. [1913 Webster] The saints have a . . . supporter in all their miseries. South. [1913… … The Collaborative International Dictionary of English
supporter — Supporter, endurer, Sufferre, Ferre, Perferre. Supporter et favoriser, Subleuare aliquem. B. ex Cic. Trop supporté et favorisé, Nimium gratiosus. B. Gens supportez et favorisez en justice, Homines in iure gratiosi, et comitate praediti prolixa et … Thresor de la langue françoyse
supporter — or athletic supporter or athletic supporter [sə pôrt′ər] n. 1. a person who supports; advocate; adherent; partisan 2. a thing that supports; esp., a) an elastic, girdlelike device worn to support the back, abdomen, etc. ☆ b) JOCKSTRAP: in full… … English World dictionary
supporter — index abettor, accomplice, advocate (espouser), apologist, assistant, backer, benefactor, coactor … Law dictionary
supporter — /sə pɔ:tə/, it. /su p:ɔrter/ s. ingl. [der. di (to ) support sostenere ], usato in ital. al masch. e al femm. [chi sostiene un atleta, una squadra sportiva, ecc.] ▶◀ aficionado, fan, sostenitore, tifoso. ↓ simpatizzante … Enciclopedia Italiana
supporter — mid 15c., agent noun from SUPPORT (Cf. support) (v.) … Etymology dictionary
supporter — /supˈpɔrter, ingl. səˈpɔːtə(r)/ [vc. ingl., da to support «sostenere»] s. m. inv. (sport) tifoso, sostenitore, fan (ingl.) … Sinonimi e Contrari. Terza edizione
supporter — ► NOUN ▪ a person who supports a sports team, policy, etc … English terms dictionary
supporter — 1. supporter [ sypɔrte ] v. tr. <conjug. : 1> • 1398; sorporter « endurer, emporter, entraîner » 1190; lat. chrét. supportare, en lat. class. « porter » I ♦ 1 ♦ Recevoir le poids, la poussée de (qqch.) sur soi, en maintenant. ⇒ soutenir; 1 … Encyclopédie Universelle
supporter — (su por té) v. a. 1° Porter, en étant dessous. Un seul pilier supporte toute la voûte. • La première [pièce de bois] qui pesait 188 livres, a supporté, pendant 46 minutes, une charge de 11 475 livres, BUFF. Hist. nat. Introd. Oeuvr. t. VIII,… … Dictionnaire de la Langue Française d'Émile Littré
Перевод: с немецкого на русский
с русского на немецкий- С русского на:
- Немецкий
- С немецкого на:
- Все языки
- Английский
- Вьетнамский
- Нидерландский
- Русский
- Суахили
- Французский