high-voltage+switchgear

  • 21 gas-insulated metal-enclosed switchgear

    1. комплектное распределительное устройство элегазовое
    2. коммутационная аппаратура в металлической оболочке с газовой изоляцией

     

    комплектное распределительное устройство элегазовое
    РУ, в котором основное оборудование заключено в оболочки, заполненные элегазом (SF6), служащим изолирующей и/или дугогасящей средой.
    [ПУЭ]

    EN

    gas-insulated metal-enclosed switchgear
    metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure
    NOTE – This term generally applies to high-voltage switchgear and controlgear
    [IEV number 441-12-05]

    FR

    appareillage sous enveloppe métallique à isolation gazeuse
    appareillage de connexion sous enveloppe métallique dans laquelle l'isolation est obtenue, au moins partiellement, par un gaz isolant autre que l'air à pression atmosphérique
    NOTE – Ce terme s'applique généralement à l'appareillage à haute tension.
    [IEV number 441-12-05]


    0403
    Рис. Siemens

    3.1.2 коммутационная аппаратура в металлической оболочке с газовой изоляцией (gas-insulated metal-enclosed switchgear): Коммутационная аппаратура в металлической оболочке, в которой изоляция обеспечивается, по крайней мере, частично изоляционным газом, отличным от воздуха при атмосферном давлении (КРУЭ).

    Примечания

    1 Термин применим к коммутационной аппаратуре высокого напряжения в комплекте с аппаратурой управления.

    2 Термин «трехфазная коммутационная аппаратура в металлической оболочке с газовой изоляцией» применяют только к аппаратуре с тремя фазами, расположенными в общей оболочке.

    3 Термин «однофазная коммутационная аппаратура в металлической оболочке с газовой изоляцией» применяют только к аппаратуре, каждая фаза которой расположена в отдельной оболочке.

    Источник: ГОСТ Р 54828-2011: Комплектные распределительные устройства в металлической оболочке с элегазовой изоляцией (КРУЭ) на номинальные напряжения 110 кВ и выше. Общие технические условия оригинал документа

    Англо-русский словарь нормативно-технической терминологии > gas-insulated metal-enclosed switchgear

  • 22 SF6 gas-insulated metal-enclosed switchgear

    1. комплектное распределительное устройство элегазовое

     

    комплектное распределительное устройство элегазовое
    РУ, в котором основное оборудование заключено в оболочки, заполненные элегазом (SF6), служащим изолирующей и/или дугогасящей средой.
    [ПУЭ]

    EN

    gas-insulated metal-enclosed switchgear
    metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure
    NOTE – This term generally applies to high-voltage switchgear and controlgear
    [IEV number 441-12-05]

    FR

    appareillage sous enveloppe métallique à isolation gazeuse
    appareillage de connexion sous enveloppe métallique dans laquelle l'isolation est obtenue, au moins partiellement, par un gaz isolant autre que l'air à pression atmosphérique
    NOTE – Ce terme s'applique généralement à l'appareillage à haute tension.
    [IEV number 441-12-05]

  • 23 power switchgear and controlgear assembly

    1. силовое комплектное устройство распределения и управления
    2. НКУ распределения и управления

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

     

    силовое комплектное устройство распределения и управления
    СНКУ

    Низковольтное комплектное устройство распределения и управления, применяемое для распределения и управления энергией всех типов нагрузок промышленного, коммерческого и аналогичного назначений, не предназначенное для управления не квалифицированным персоналом.
    [ ГОСТ Р МЭК 61439.2-2012]

    EN

    power switchgear and controlgear assembly
    PSC-assembly

    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    NOTE It is not excluded for a PSC-assembly to be located in an area accessible to ordinary persons.
    [IEC 61439-2, ed. 2.0 (2011-08)]

    FR

    ensemble d'appareillage de puissance
    ensemble EAP
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    NOTE Il n’est pas exclu d’implanter un ensemble EAP dans une zone accessible aux personnes ordinaires.
    [IEC 61439-2, ed. 2.0 (2011-08)]

    Тематики

    • НКУ (шкафы, пульты,...)

    Синонимы

    EN

    FR

    Англо-русский словарь нормативно-технической терминологии > power switchgear and controlgear assembly

  • 24 low voltage controlgear and assembly

    1. НКУ распределения и управления

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

    Англо-русский словарь нормативно-технической терминологии > low voltage controlgear and assembly

  • 25 low voltage switchboard

    1. НКУ распределения и управления

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

    Англо-русский словарь нормативно-технической терминологии > low voltage switchboard

  • 26 LV switchgear and controlgear assembly

    1. НКУ распределения и управления

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

    Англо-русский словарь нормативно-технической терминологии > LV switchgear and controlgear assembly

  • 27 LV switchgear assembly

    1. НКУ распределения и управления

     

    низковольтное устройство распределения и управления (НКУ)
    Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
    [ ГОСТ Р МЭК 61439-1-2012]

    низковольтное устройство распределения и управления

    Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
    Примечания
    1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
    2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
    3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    EN

    power switchgear and controlgear assembly (PSC-assembly)
    low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
    [IEC 61439-2, ed. 1.0 (2009-01)]

    low-voltage switchgear and controlgear assembly
    combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
    [IEC 61892-3, ed. 2.0 (2007-11)]

    switchgear and controlgear
    a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
    [IEV number 441-11-01]

    switchgear and controlgear

    electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
    NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
    [IEV number 826-16-03 ]

    switchboard
    A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
    [ McGraw-Hill Dictionary of Architecture & Construction]

    switchboard
    One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
    [ The American Heritage Dictionary of the English Language]

    FR

    ensemble d'appareillage de puissance (ensemble PSC)
    ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
    [IEC 61439-2, ed. 1.0 (2009-01)]

    appareillage, m
    matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
    NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
    [IEV number 826-16-03 ]

    appareillage
    terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
    [IEV number 441-11-01]


    A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
    Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
    The types of switchboards, classified by basic features of construction, are as follows:
    1. Live-front vertical panels
    2. Dead-front boards
    3. Safety enclosed boards( metal-clad)


    [American electricians’ handbook]

    Параллельные тексты EN-RU

    The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.

    Its definition, design and installation are based on precise rules; there is no place for improvisation.

    The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.

    It specifies in particular:

    > the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;

    > the design and verification rules, constituting a benchmark for product certification.

    All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.


    Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.

    A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.

    Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.

    What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.

    [Schneider Electric]

    НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.

    Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.

    Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).

    В частности, он определяет:

    > распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;

    > конструкцию, технические характеристики, виды и методы испытаний НКУ.

    В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.

    Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.

    Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.

    Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.

    Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.

    [Перевод Интент]

     

    LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.

    The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.

    In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.

    Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.

    The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.

    [ABB]

    Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.

    Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам

    Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.

    Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются

    Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Действия

    Синонимы

    Сопутствующие термины

    EN

    DE

    • Schaltanlagen und/oder Schaltgeräte

    FR

    Англо-русский словарь нормативно-технической терминологии > LV switchgear assembly

  • 28 arc-proof switchgear

    1. НКУ с защитой от воздействия электрической дуги

     

    НКУ с защитой от воздействия электрической дуги
    комплектное устройство с защитой от электрической дуги
    низковольтное комплектное устройство с защитой от электрической дуги
    НКУ распределения и управления с защитой от электрической дуги
    -
    [Интент]

    EN

    arc-resistant switchgear
    A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.

    There are three classes of protection:
    Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
    Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
    Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.

    Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.

    arc-proof switchgear
    An incorrect term. Please refer to arc-resistant switchgear
    [Schneider Electric]
    [ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]

    Параллельные тексты EN-RU

    If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.

    Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.

    The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.

    Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.

    This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.

    Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
    1. assemblies mechanically capable of withstanding the electric arc (passive protection)
    2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
    3. assemblies equipped with current limiting circuitbreakers.

    These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.

    As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.

    This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.

    [ABB]

    Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.

    Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.

    Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.

    Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.

    Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.

    При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
    1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
    2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
    3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.

    Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.

    Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.

    Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Синонимы

    EN

    Англо-русский словарь нормативно-технической терминологии > arc-proof switchgear

  • 29 arc-resistant switchgear

    1. НКУ с защитой от воздействия электрической дуги

     

    НКУ с защитой от воздействия электрической дуги
    комплектное устройство с защитой от электрической дуги
    низковольтное комплектное устройство с защитой от электрической дуги
    НКУ распределения и управления с защитой от электрической дуги
    -
    [Интент]

    EN

    arc-resistant switchgear
    A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.

    There are three classes of protection:
    Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
    Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
    Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.

    Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.

    arc-proof switchgear
    An incorrect term. Please refer to arc-resistant switchgear
    [Schneider Electric]
    [ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]

    Параллельные тексты EN-RU

    If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.

    Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.

    The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.

    Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.

    This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.

    Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
    1. assemblies mechanically capable of withstanding the electric arc (passive protection)
    2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
    3. assemblies equipped with current limiting circuitbreakers.

    These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.

    As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.

    This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.

    [ABB]

    Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.

    Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.

    Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.

    Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.

    Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.

    При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
    1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
    2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
    3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.

    Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.

    Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.

    Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Синонимы

    EN

    Англо-русский словарь нормативно-технической терминологии > arc-resistant switchgear

  • 30 internal arc-proof switchgear and controlgear assemblу

    1. НКУ с защитой от воздействия электрической дуги

     

    НКУ с защитой от воздействия электрической дуги
    комплектное устройство с защитой от электрической дуги
    низковольтное комплектное устройство с защитой от электрической дуги
    НКУ распределения и управления с защитой от электрической дуги
    -
    [Интент]

    EN

    arc-resistant switchgear
    A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.

    There are three classes of protection:
    Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
    Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
    Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.

    Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.

    arc-proof switchgear
    An incorrect term. Please refer to arc-resistant switchgear
    [Schneider Electric]
    [ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]

    Параллельные тексты EN-RU

    If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.

    Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.

    The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.

    Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.

    This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.

    Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
    1. assemblies mechanically capable of withstanding the electric arc (passive protection)
    2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
    3. assemblies equipped with current limiting circuitbreakers.

    These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.

    As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.

    This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.

    [ABB]

    Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.

    Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.

    Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.

    Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.

    Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.

    При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
    1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
    2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
    3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.

    Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.

    Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.

    Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Синонимы

    EN

    Англо-русский словарь нормативно-технической терминологии > internal arc-proof switchgear and controlgear assemblу

  • 31 высоковольтная коммутационная аппаратура

    Англо-русский словарь технических терминов > высоковольтная коммутационная аппаратура

  • 32 высоковольтное распределительное устройство

    Англо-русский словарь технических терминов > высоковольтное распределительное устройство

  • 33 power center

    1. комплектное устройство первичного распределения электроэнергии
    2. главный распределительный щит

     

    главный распределительный щит (ГРЩ)
    Распределительный щит, через который снабжается электроэнергией все здание или его обособленная часть. Роль ГРЩ может выполнять ВРУ или щит низкого напряжения подстанции.
    [ПУЭ]

    главный распределительный щит
    Электрощит в здании, обеспечивающий распределение энергии между подключенными к нему нагрузками и включение аварийных систем при падении напряжения.
    [ ГОСТ Р 51321. 3-99 ( МЭК 60439-3-90)]
    [ ГОСТ Р 50571.28-2006]

    EN

    main distribution board
    board in the building which fulfils all the functions of a main electrical distribution for the supply building area assigned to it and where the voltage drop is measured for operating the safety services
    [IEC 60364-7-710, ed. 1.0 (2002-11)]

    FR

    tableau général de distribution
    tableau de distribution dans le bâtiment remplissant toutes les fonctions d’un tableau général de distribution pour l’alimentation de la zone qui lui est dédiée et où la chute de tension est mesurée pour le fonctionnement des services de sécurité
    [IEC 60364-7-710, ed. 1.0 (2002-11)]

    0505
    Главный распределительный щит (ГРЩ) на ток 6300 А
    [http://www.uzoelectro.ru/catalogue/group-383/product-36465/ ]

    Тематики

    Синонимы

    EN

    FR

     

    комплектное устройство первичного распределения электроэнергии
    -
    [Интент]

    0479
    Рис. ABB

    Параллельные тексты EN-RU

    They are usually installed on the load side of MV/LV transformers or generators.
    These assemblies include one or more incoming units, bus ties and a relatively reduced number of outgoing units.
    There are also present measuring instruments and other switching and control equipment.
    These assemblies have a sturdy structure to withstand the electrodynamic stresses and the weight of big sized apparatus.
    As a matter of fact peculiar characteristics of the power center are high rated currents and shortcircuit currents.
    The constructional type is a cubicle structure, with metal enclosure and sections divided into compartments with selective access.

    [ABB]

    Такие устройства обычно подключают на стороне нагрузки СВ/НВ трансформаторов или генераторов.
    В их состав входят один или несколько блоков ввода, шины и относительно небольшое число блоков вывода.
    В состав комплектного устройства первичного распределения электроэнергии входят также измерительные приборы, коммутационные устройства и средства контроля состояния.
    Данные комплектные устройства имеют прочную конструкцию, способную выдерживать электродинамическое действие токов и вес крупногабаритной аппаратуры.
    Центры распределения электроэнергии характеризуются высокими номинальным током и током короткого замыкания.
    С точки зрения конструктивного исполнения они представляют собой многошкафное комплектное устройство в металлической оболочке, состоящее из секций, каждая из которых разделена на отсеки с независимым доступом
    .

    [Перевод Интент]

    Safety enclosed boards are used for most new installations. Common terms used to designate equipment of this type are metal-enclosed switchgear and metal-clad switchgear.
    Most safety enclosed boards are of the unit or sectional type. They consist of a combination of the desired number and type of standardized unit sections.
    Each section is a standard factory-assembled combination of a formed steel panel and apparatus mounted on a steel framework.

    Safety enclosed switchgear may be classified with respect to purpose of application as follows:
    1. General medium- or high-voltage switchgear
    2. Primary unit substations
    3. Rectifier unit substations
    4. Secondary unit substations or power centers
    5. General low-voltage switchgear
    6. Low-voltage distribution switchboards
    7. Motor-control-center switchboar
    ds

    [American electricians’ handbook]

    Тематики

    • НКУ (шкафы, пульты,...)
    • комплектное распред. устройство (КРУ)

    EN

    Англо-русский словарь нормативно-технической терминологии > power center

  • 34 primary unit substation

    1. комплектное устройство первичного распределения электроэнергии

     

    комплектное устройство первичного распределения электроэнергии
    -
    [Интент]

    0479
    Рис. ABB

    Параллельные тексты EN-RU

    They are usually installed on the load side of MV/LV transformers or generators.
    These assemblies include one or more incoming units, bus ties and a relatively reduced number of outgoing units.
    There are also present measuring instruments and other switching and control equipment.
    These assemblies have a sturdy structure to withstand the electrodynamic stresses and the weight of big sized apparatus.
    As a matter of fact peculiar characteristics of the power center are high rated currents and shortcircuit currents.
    The constructional type is a cubicle structure, with metal enclosure and sections divided into compartments with selective access.

    [ABB]

    Такие устройства обычно подключают на стороне нагрузки СВ/НВ трансформаторов или генераторов.
    В их состав входят один или несколько блоков ввода, шины и относительно небольшое число блоков вывода.
    В состав комплектного устройства первичного распределения электроэнергии входят также измерительные приборы, коммутационные устройства и средства контроля состояния.
    Данные комплектные устройства имеют прочную конструкцию, способную выдерживать электродинамическое действие токов и вес крупногабаритной аппаратуры.
    Центры распределения электроэнергии характеризуются высокими номинальным током и током короткого замыкания.
    С точки зрения конструктивного исполнения они представляют собой многошкафное комплектное устройство в металлической оболочке, состоящее из секций, каждая из которых разделена на отсеки с независимым доступом
    .

    [Перевод Интент]

    Safety enclosed boards are used for most new installations. Common terms used to designate equipment of this type are metal-enclosed switchgear and metal-clad switchgear.
    Most safety enclosed boards are of the unit or sectional type. They consist of a combination of the desired number and type of standardized unit sections.
    Each section is a standard factory-assembled combination of a formed steel panel and apparatus mounted on a steel framework.

    Safety enclosed switchgear may be classified with respect to purpose of application as follows:
    1. General medium- or high-voltage switchgear
    2. Primary unit substations
    3. Rectifier unit substations
    4. Secondary unit substations or power centers
    5. General low-voltage switchgear
    6. Low-voltage distribution switchboards
    7. Motor-control-center switchboar
    ds

    [American electricians’ handbook]

    Тематики

    • НКУ (шкафы, пульты,...)
    • комплектное распред. устройство (КРУ)

    EN

    Англо-русский словарь нормативно-технической терминологии > primary unit substation

  • 35 enclosed switchboard

    1. НКУ защищенное
    2. закрытый щит

     

    закрытый щит

    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    Тематики

    • электротехника, основные понятия

    EN

     

    НКУ защищенное
    НКУ закрытое со всех сторон (за возможным исключением монтажной поверхности), в котором после его установки обеспечивается степень защиты не менее IP2X.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    защищенное НКУ
    НКУ, конструкция которого обеспечивает требуемую степень защиты со всех сторон от прикосновения к частям, находящимся под напряжением (за исключением монтажной поверхности).
    [ ГОСТ Р МЭК 61439.1-2013]

    EN

    enclosed assembly (of switchgear and controlgear)
    an assembly enclosed on all sides, top and bottom in such a manner as to provide a specified degree of protection
    NOTE – The mounting surface may form a part of the enclosure when specified in the relevant publication.
    [IEV number 441-12-02]

    FR

    ensemble (d'appareillage de connexion et de commande)
    sous enveloppe
    ensemble comportant une paroi sur toutes ses faces latérales, supérieure et inférieure, de façon à assurer un degré de protection spécifié
    NOTE – La surface de montage peut faire partie de l'enveloppe lorsqu'une publication particulière le spécifie.
    [IEV number 441-12-0

    0078
    Шкаф - защищенное НКУ, предназначенное для установки на полу


    Safety enclosed boards are used for most new installations. Common terms used to designate equipment of this type are metal-enclosed switchgear and metal-clad switchgear.
    Most safety enclosed boards are of the unit or sectional type. They consist of a combination of the desired number and type of standardized unit sections.
    Each section is a standard factory-assembled combination of a formed steel panel and apparatus mounted on a steel framework.


    Safety enclosed switchgear may be classified with respect to purpose of application as follows:
    1. General medium- or high-voltage switchgear
    2. Primary unit substations
    3. Rectifier unit substations
    4. Secondary unit substations or power centers
    5. General low-voltage switchgear
    6. Low-voltage distribution switchboards
    7. Motor-control-center switchboards

    [American electricians’ handbook]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Обобщающие термины

    Синонимы

    EN

    DE

    FR

    Англо-русский словарь нормативно-технической терминологии > enclosed switchboard

  • 36 safety enclosed board

    1. НКУ защищенное

     

    НКУ защищенное
    НКУ закрытое со всех сторон (за возможным исключением монтажной поверхности), в котором после его установки обеспечивается степень защиты не менее IP2X.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    защищенное НКУ
    НКУ, конструкция которого обеспечивает требуемую степень защиты со всех сторон от прикосновения к частям, находящимся под напряжением (за исключением монтажной поверхности).
    [ ГОСТ Р МЭК 61439.1-2013]

    EN

    enclosed assembly (of switchgear and controlgear)
    an assembly enclosed on all sides, top and bottom in such a manner as to provide a specified degree of protection
    NOTE – The mounting surface may form a part of the enclosure when specified in the relevant publication.
    [IEV number 441-12-02]

    FR

    ensemble (d'appareillage de connexion et de commande)
    sous enveloppe
    ensemble comportant une paroi sur toutes ses faces latérales, supérieure et inférieure, de façon à assurer un degré de protection spécifié
    NOTE – La surface de montage peut faire partie de l'enveloppe lorsqu'une publication particulière le spécifie.
    [IEV number 441-12-0

    0078
    Шкаф - защищенное НКУ, предназначенное для установки на полу


    Safety enclosed boards are used for most new installations. Common terms used to designate equipment of this type are metal-enclosed switchgear and metal-clad switchgear.
    Most safety enclosed boards are of the unit or sectional type. They consist of a combination of the desired number and type of standardized unit sections.
    Each section is a standard factory-assembled combination of a formed steel panel and apparatus mounted on a steel framework.


    Safety enclosed switchgear may be classified with respect to purpose of application as follows:
    1. General medium- or high-voltage switchgear
    2. Primary unit substations
    3. Rectifier unit substations
    4. Secondary unit substations or power centers
    5. General low-voltage switchgear
    6. Low-voltage distribution switchboards
    7. Motor-control-center switchboards

    [American electricians’ handbook]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Обобщающие термины

    Синонимы

    EN

    DE

    FR

    Англо-русский словарь нормативно-технической терминологии > safety enclosed board

  • 37 GIS

    1. свидетельство
    2. КРУ с газовой изоляцией
    3. комплектное распределительное устройство элегазовое
    4. комплектное распределительное устройство с элегазовой изоляцией
    5. глобальное информационное общество
    6. ГИС
    7. географическая информационная система (ГИС)
    8. географическая информационная система
    9. газоизолированная подстанция
    10. выключатель элегазовый
    11. выключатель с газовой изоляцией

     

    выключатель с газовой изоляцией

    [А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]

    Тематики

    EN

     

    выключатель элегазовый
    Выключатель газовый, контакты которого размыкаются и замыкаются в элегазе (шестифтористой сере).
    [ ГОСТ Р 52565-2006]

    EN

    sulphur hexafluoride circuit-breaker
    SF6 circuit-breaker

    a circuit-breaker in which the contacts open and close in sulphur hexafluoride
    [IEV number 441-14-31]

    FR

    disjoncteur à hexafluorure de soufre
    disjoncteur à SF6

    disjoncteur dont les contacts s'ouvrent et se ferment dans l'hexafluorure de soufre
    [IEV number 441-14-31]

    Для РУ напряжением 110 кВ и выше (вплоть до 1150 кВ) наиболее широко используются воздушные выключатели, где гашение дуги осуществляется потоком сжатого воздуха. Однако в последнее время они вытесняются элегазовыми выключателями, в которых в качестве дугогасящей среды используется электроотрицательный газ — шестифтористая сера (элегаз). Такие выключатели создаются для герметичных распределительных устройств (ГРУ), а также для наружной установки. Использование элегаза в качестве дугогасящей среды обусловлено его высокими изоляционными и дугогасящими свойствами. Это позволяет создать более совершенные выключатели с меньшим числом дугогасительных разрывов, с меньшими габаритами и более надежные в эксплуатации.
    [А. И. Афанасьев и др. Электрические аппараты высокого напряжения. - 2-е изд., доп. СПбГТУ, 2000, 503 с.]

    Тематики

    • выключатель, переключатель
    • высоковольтный аппарат, оборудование...

    EN

    DE

    FR

     

    ГИС
    Географическая информационная система
    геоинформационная система

    Информационная система, обеспечивающая сбор, хранение, обработку, доступ, отображение и распространение пространственно-координированных данных (пространственных данных). ГИС содержит данные о пространственных обьектах в форме их цифровых представлений (векторных, растровых, квадротомических и иных), включает соответствующий задачам набор функциональных возможностей ГИС, в которых реализуются операции геоинформационных технологий, или ГИС-технологий (GIS tehnology), поддерживается программным, аппаратным, информационным, нормативно-правовым, кадровым и организационным обеспечением. По территориапьному охвату различают глобальные, или планетарные ГИС (global GIS), субконтинентальные ГИС, национальные ГИС, зачастую имеющие статус государственных, региональные ГИС (regional GIS), субрегиональные ГИС и локальные, или местные ГИС (lokal GIS). ГИС различаются предметной областью информационного моделирования, к примеру, городские ГИС, или муниципальные ГИС, МГИС (urban GIS), природоохранные ГИС (environmental GIS) и т.п.; среди них особое наименование, как особо широко распространенные, получили земельные информационные системы. Проблемная ориентация ГИС определяется решаемыми в ней задачами (научными и прикладными), среди них инвентаризация ресурсов (в том числе кадастр), анализ, оценка, мониторинг, управление и ппантрование, поддержка принятия решений. Интегрированные ГИС, ИГИС (integrated GIS, IGIS) совмещают функциональные возможности ГИС и систем цифровой обработки изображений (материалов дистанционного зондирования) в единой интегрированной среде. Полимасштабные, или масштабно-независимые ГИС (multiscale GIS) основаны на множественных, или полимасштабных представпениях пространственных объектов (multiple representation, multiscale representation), обеспечивая графическое или картографическое вопроизведение данных на любом из избранных уровней масштабного ряда на основе единственного набора данных с наибольшим пространственным разрешением. Пространственно-временные ГИС (spatio-temporal GIS) оперируют пространственно-временными данными. Реализация геоинформационных проектов (GIS project), создание ГИС в широком смысле слова, включает этапы предпроектных исследований (feasibility stady), в том числе изучение требований пользователя (user requirements) и функциональных возможностей используемых программных средств ГИС, технико-экономическое обоснование, оценку соотношения "затраты/прибыль" (costs/benefits); системное проектирование ГИС (GIS designing), включая стадию пилот-проекта (pilot-project), разработку ГИС (GIS development); ее тестирование на небольшом территориальном фрагменте, или тестовом участке (test area), прототипирование, или создание опытного образца, прототипа (prototype); внедрение ГИС (GIS implementation), эксплуатацию и использование. Научные, технические, технологические и прикладные аспекты проектирования, создания и использования ГИС изучаются геоинформатикой.
    [ http://www.morepc.ru/dict/]

    Тематики

    Синонимы

    EN

     

    газоизолированная подстанция
    Электрическая подстанция, оборудование которой заключено в металлический кожух, заполненный изолирующим газом.
    [ ГОСТ 24291-90]

    EN

    gas insulated metal-enclosed substation
    a substation which is made up with only gas insulated metal enclosed switchgear
    [IEV number 605-02-14 ]

    FR

    poste sous enveloppe métallique à isolation gazeuse
    poste ne comportant que de l'appareillage sous enveloppe métallique à isolation gazeuse
    [IEV number 605-02-14 ]

    Тематики

    EN

    DE

    FR

     

    географическая информационная система
    ГИС


    [Упрощение процедур торговли: англо-русский глоссарий терминов (пересмотренное второе издание) НЬЮ-ЙОРК, ЖЕНЕВА, МОСКВА 2011 год]

    EN

    geographic information system
    GIS


    [Trade Facilitation Terms: An English - Russian Glossary (revised second edition) NEW YORK, GENEVA, MOSCOW 2456]

    Тематики

    Синонимы

    EN

     

    глобальное информационное общество

    [Л.Г.Суменко. Англо-русский словарь по информационным технологиям. М.: ГП ЦНИИС, 2003.]

    Тематики

    EN

     

    КРУ с газовой изоляцией

    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    Тематики

    • электротехника, основные понятия

    EN

     

    комплектное распределительное устройство с элегазовой изоляцией
    КРУЭ
    -

    Параллельные тексты EN-RU

    The circuit breaker forms the central element of the gas insulated switchgear.
    [Siemens]

    Силовой выключатель является основным элементом КРУЭ.
    [Перевод Интент]

    Switchgears of type 8DQ1 are metal-enclosed, gas-insulated switchgears for operating voltages up to 345 / 420 kV. They consist of individual switchgear bays.
    [Siemens]

    КРУЭ 8DQ1 представляет собой комплектное распределительное устройство в металлической оболочке с элегазовой изоляцией на напряжение до 345/420 кВ. КРУЭ состоит из отдельных ячеек.
    [Перевод Интент]

    These operating instructions are valid for the type and version of the metal-enclosed gas-insulated switchgear specified on the title page.
    [Siemens]

    Данный документ представляет собой Руководство по эксплуатации комплектного распределительного устройства в металлической оболочке с элегазовой изоляцией (КРУЭ) тип и исполнение которого указаны на обложке.
    [Перевод Интент]

    Тематики

    • комплектное распред. устройство (КРУ)

    Синонимы

    EN

     

    комплектное распределительное устройство элегазовое
    РУ, в котором основное оборудование заключено в оболочки, заполненные элегазом (SF6), служащим изолирующей и/или дугогасящей средой.
    [ПУЭ]

    EN

    gas-insulated metal-enclosed switchgear
    metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure
    NOTE – This term generally applies to high-voltage switchgear and controlgear
    [IEV number 441-12-05]

    FR

    appareillage sous enveloppe métallique à isolation gazeuse
    appareillage de connexion sous enveloppe métallique dans laquelle l'isolation est obtenue, au moins partiellement, par un gaz isolant autre que l'air à pression atmosphérique
    NOTE – Ce terme s'applique généralement à l'appareillage à haute tension.
    [IEV number 441-12-05]


    0403
    Рис. Siemens

    2.1.35 свидетельство: Документ, официально подтверждающий какой-либо факт, имеющий юридическое значение, либо право лица (об окончании учебного заведения).

    2.2. В настоящем руководстве применены следующие сокращения на русском языке:

    АМИС

    Автоматическая метеорологическая измерительная система

    АМРК

    Автоматизированный метеорологический радиолокационный комплекс

    АМСГ

    Авиационная метеорологическая станция (гражданская)

    АМЦ

    Авиационный метеорологический центр

    БАМД

    Банк авиационных метеорологических данных

    ВМО

    Всемирная метеорологическая организация

    ВНГО

    Высота нижней границы облаков

    ВПП

    Взлетно-посадочная полоса

    ВС

    Воздушное судно

    ВСЗП

    Всемирная система зональных прогнозов

    ВЦЗП

    Всемирный центр зональных прогнозов

    ГАМЦ

    Главный авиационный метеорологический центр

    ГИС

    Географическая информационная система

    ГОУ ИПК

    Государственное образовательное учреждение «Институт повышения квалификации»

    ГСТ

    Глобальная система телесвязи

    ГУ ГРМЦ

    Государственное учреждение «Главный радиометеорологический центр»

    ДОТ

    Дистанционные образовательные технологии

    ИТ

    Информационные технологии

    КПК

    Курсы повышения квалификации

    КРАМС

    Комплексная радиотехническая аэродромная метеорологическая станция

    МРЛ

    Метеорологический радиолокатор

    НГЭА

    Нормы годности к эксплуатации гражданских аэродромов

    НОО

    Непрерывное образование и обучение

    НПР

    Непрерывное профессиональное развитие

    ОВД

    Обслуживание воздушного движения

    ОГ

    Оперативная группа

    ОМС

    Орган метеорологического слежения

    УВД

    Управление воздушным движением

    2.3. В настоящем руководстве применены следующие сокращения на английском языке:

    AFTN

    Aeronautical Fixed Telecommunication Network

    Авиационная фиксированная сеть электросвязи

    AIRMET

    AIRman's METeorological information

    Выпускаемая органом метеорологического слежения информация о фактическом или ожидаемом возникновении определенных явлений погоды по маршруту полета, которые могут повлиять на безопасность полетов воздушных судов на малых высотах

    ATIS

    Automatic Terminal Information Service

    Автоматическая аэродромная служба информации

    BUFR

    Binary Universal Form for the Representation of meteorological date

    Двоичная универсальная форма для представления метеорологических данных

    GIS

    Geographic Information Systems

    Географическая информационная система

    GAMET

    General Aviation METeorological forecast

    Зональный прогноз, составляемый открытым текстом с сокращениями для полетов на малых высотах применительно к району полетной информации или его субрайону (подрайону) метеорологическим органом и передаваемый метеорологическим органам соседних районов полетной информации

    GRIB

    GRIdded Binary

    Бинарный код (прогностические данные метеорологических элементов в узлах регулярной сетки)

    GTS

    Global Telecommunication System

    Глобальная система телесвязи (в рамках ВМО)

    IAVW

    International Airways Volcano Watch

    Служба слежения за вулканической деятельностью на международных авиатрассах

    ICAO

    International Civil Aviation Organization

    Международная организация гражданской авиации

    ISCS

    International Satellite Communications System

    Международная спутниковая система телесвязи (обеспечивается США)

    METAR

    METeorological Aerodrome Report

    Метеорологическая сводка по аэродрому (код METAR)

    MOR

    Meteorological Optical Range

    Метеорологическая оптическая дальность

    OPMET

    Operational METeorological information

    Оперативная метеорологическая информация (данные)

    QFE

    Atmospheric pressure at the runway threshold (or at the aerodrome elevation)

    Атмосферное давление на уровне порога ВПП (или аэродрома)

    QNH

    Atmospheric pressure at the aerodrome elevation corrected to the mean sea level according to standard atmosphere

    Атмосферное давление на уровне аэродрома, приведенное к среднему уровню моря по стандартной атмосфере

    RVR

    Runway Visual Range

    Дальность видимости на ВПП

    SADIS

    SAtellite Distribution System

    Спутниковая система рассылки метеорологических данных (обеспечивается Великобританией)

    SIGMET

    SIGnificant METeorological information

    Выпускаемая органом метеорологического слежения информация о фактическом или ожидаемом возникновении определенных явлений погоды по маршруту полета, которые могут повлиять на безопасность полетов воздушных судов

    SIGWX

    SIGnificant Weather

    Особые явления погоды

    SPECI

    SPECIal report

    Специальная метеорологическая сводка (по аэродрому)

    TAF

    Terminal Aerodrome Forecast

    Прогноз по аэродрому

    TCAC

    Tropical Cyclone Aadvisory Center

    Консультативный центр по тропическим циклонам

    TREND

    TREND

    Прогноз для посадки

    VAAC

    Volcanic Ash Advisory Center

    Консультативный центр по вулканическому пеплу

    VOLMET

    Volume of meteorological information for aircraft in flight

    Объем метеорологической информации для воздушных судов, находящихся в полете

    Источник: РД 52.21.703-2008: Руководство по образованию и обучению специалистов в области авиационной метеорологии

    Англо-русский словарь нормативно-технической терминологии > GIS

  • 38 withdrawn position

    1. отсоединенное положение
    2. отделенное положение

     

    отделенное положение
    Положение съемной или выдвижной части, при котором она находится вне НКУ и механически и электрически отделена от него.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    отделенное положение
    Положение выдвижной отделяемой части НКУ, когда она находится вне НКУ, механически и электрически отсоединена от него.
    [ ГОСТ Р МЭК 61439.1-2013]

    EN

    removed position (of a removable part)
    a position of a removable part when it is outside and mechanically and electrically separated from the assembly
    [IEV number 441-16-29]

    FR

    position de retrait (d'une partie amovible)
    position d'une partie amovible quand elle est retirée et séparée mécaniquement et électriquement de l'ensemble
    [IEV number 441-16-29]

    Параллельные тексты EN-RU

    5658
    Рис. Schneider Electric

    Withdrawn
    - The drawer can be fully extracted.
    - Allows quick replacement.
    - Allows switchboard live change.
    - Padlocking is possible on the fixed part.

    [Schneider Electric]

    Отделённое положение
    - Выдвижной ящик можно полностью извлечь из шкафа.
    - Можно быстро заменить выдвижные ящики.
    - Можно заменять ящики, не отключая шкафа.
    - Стационарная часть может быть заблокирована навесным замком.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Синонимы

    EN

    DE

    FR

     

    отсоединенное (изолированное) положение
    Положение выдвижной части, при котором в ее главных и вспомогательных цепях достигается изоляционный промежуток, при этом выдвижная часть остается механически присоединенной к НКУ.
    Примечание — Изоляционный промежуток может достигаться с помощью специального устройства без механического перемещения выдвижной части.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    отсоединенное (изолированное) положение
    Положение выдвижной неотделяемой части, при котором в ее главных и вспомогательных цепях на стороне питания обеспечивается изолирующий промежуток, при этом выдвижная неотделяемая часть остается механически соединенной с СНКУ.
    Примечание Изолирующий промежуток может быть достигнут с помощью специального устройства без механического перемещения выдвижной неотделяемой части.
    [ ГОСТ Р МЭК 61439.2-2012]

    EN

    disconnected position (of a withdrawable part)
    isolated position (of a withdrawable part)
    the position of a withdrawable part in which an isolating distance or segregation is established in all the circuits of the withdrawable part, that part remaining mechanically attached to the assembly
    NOTE – In enclosed high-voltage switchgear and controlgear the auxiliary circuits may not be disconnected.
    [IEV number 441-16-28]

    FR

    position de sectionnement (d'une partie débrochable)
    position d'une partie débrochable dans laquelle une distance de sectionnement est établie ou un cloisonnement métallique est mis en place dans les circuits de la partie débrochable, cette partie restant mécaniquement reliée à l'ensemble
    NOTE – Dans l'appareillage à haute tension sous enveloppe, les circuits auxiliaires peuvent rester branchés.
    [IEV number 441-16-28]

    Параллельные тексты EN-RU

    5657

    Рис. Schneider Electric

    Draw out
    - The functional unit is not operational.
    - Power and auxiliaries are disconnected.
    - Padlocking is possible to keep the drawer in this position.
    - Allows maintenance on the process.

    [Schneider Electric]

    Отсоединённое положение
    - В данном положении функциональный блок не может выполнять функцию питания нагрузки.
    - Главная и вспомогательные цепи отсоединены.
    - Ящик можно зафиксировать в данном положении навесным замком.
    - Можно выполнять техническое обслуживание.

    [Перевод Интент]

     

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Синонимы

    EN

    DE

    FR

    Англо-русский словарь нормативно-технической терминологии > withdrawn position

  • 39 disconnected position (of a withdrawable part)

    1. отсоединенное положение

     

    отсоединенное (изолированное) положение
    Положение выдвижной части, при котором в ее главных и вспомогательных цепях достигается изоляционный промежуток, при этом выдвижная часть остается механически присоединенной к НКУ.
    Примечание — Изоляционный промежуток может достигаться с помощью специального устройства без механического перемещения выдвижной части.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    отсоединенное (изолированное) положение
    Положение выдвижной неотделяемой части, при котором в ее главных и вспомогательных цепях на стороне питания обеспечивается изолирующий промежуток, при этом выдвижная неотделяемая часть остается механически соединенной с СНКУ.
    Примечание Изолирующий промежуток может быть достигнут с помощью специального устройства без механического перемещения выдвижной неотделяемой части.
    [ ГОСТ Р МЭК 61439.2-2012]

    EN

    disconnected position (of a withdrawable part)
    isolated position (of a withdrawable part)
    the position of a withdrawable part in which an isolating distance or segregation is established in all the circuits of the withdrawable part, that part remaining mechanically attached to the assembly
    NOTE – In enclosed high-voltage switchgear and controlgear the auxiliary circuits may not be disconnected.
    [IEV number 441-16-28]

    FR

    position de sectionnement (d'une partie débrochable)
    position d'une partie débrochable dans laquelle une distance de sectionnement est établie ou un cloisonnement métallique est mis en place dans les circuits de la partie débrochable, cette partie restant mécaniquement reliée à l'ensemble
    NOTE – Dans l'appareillage à haute tension sous enveloppe, les circuits auxiliaires peuvent rester branchés.
    [IEV number 441-16-28]

    Параллельные тексты EN-RU

    5657

    Рис. Schneider Electric

    Draw out
    - The functional unit is not operational.
    - Power and auxiliaries are disconnected.
    - Padlocking is possible to keep the drawer in this position.
    - Allows maintenance on the process.

    [Schneider Electric]

    Отсоединённое положение
    - В данном положении функциональный блок не может выполнять функцию питания нагрузки.
    - Главная и вспомогательные цепи отсоединены.
    - Ящик можно зафиксировать в данном положении навесным замком.
    - Можно выполнять техническое обслуживание.

    [Перевод Интент]

     

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Синонимы

    EN

    DE

    FR

    Англо-русский словарь нормативно-технической терминологии > disconnected position (of a withdrawable part)

  • 40 draw-out

    1. отсоединенное положение

     

    отсоединенное (изолированное) положение
    Положение выдвижной части, при котором в ее главных и вспомогательных цепях достигается изоляционный промежуток, при этом выдвижная часть остается механически присоединенной к НКУ.
    Примечание — Изоляционный промежуток может достигаться с помощью специального устройства без механического перемещения выдвижной части.
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    отсоединенное (изолированное) положение
    Положение выдвижной неотделяемой части, при котором в ее главных и вспомогательных цепях на стороне питания обеспечивается изолирующий промежуток, при этом выдвижная неотделяемая часть остается механически соединенной с СНКУ.
    Примечание Изолирующий промежуток может быть достигнут с помощью специального устройства без механического перемещения выдвижной неотделяемой части.
    [ ГОСТ Р МЭК 61439.2-2012]

    EN

    disconnected position (of a withdrawable part)
    isolated position (of a withdrawable part)
    the position of a withdrawable part in which an isolating distance or segregation is established in all the circuits of the withdrawable part, that part remaining mechanically attached to the assembly
    NOTE – In enclosed high-voltage switchgear and controlgear the auxiliary circuits may not be disconnected.
    [IEV number 441-16-28]

    FR

    position de sectionnement (d'une partie débrochable)
    position d'une partie débrochable dans laquelle une distance de sectionnement est établie ou un cloisonnement métallique est mis en place dans les circuits de la partie débrochable, cette partie restant mécaniquement reliée à l'ensemble
    NOTE – Dans l'appareillage à haute tension sous enveloppe, les circuits auxiliaires peuvent rester branchés.
    [IEV number 441-16-28]

    Параллельные тексты EN-RU

    5657

    Рис. Schneider Electric

    Draw out
    - The functional unit is not operational.
    - Power and auxiliaries are disconnected.
    - Padlocking is possible to keep the drawer in this position.
    - Allows maintenance on the process.

    [Schneider Electric]

    Отсоединённое положение
    - В данном положении функциональный блок не может выполнять функцию питания нагрузки.
    - Главная и вспомогательные цепи отсоединены.
    - Ящик можно зафиксировать в данном положении навесным замком.
    - Можно выполнять техническое обслуживание.

    [Перевод Интент]

     

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    Синонимы

    EN

    DE

    FR

    Англо-русский словарь нормативно-технической терминологии > draw-out

См. также в других словарях:

  • High voltage switchgear — is any switchgear used to connect or disconnect a part of a high voltage power system. These switchgear are essential elements for the protection and safe operation, without interruption, of a high voltage power system. This type of equipment is… …   Wikipedia

  • High voltage — The term high voltage characterizes electrical circuits, in which the voltage used is the cause of particular safety concerns and insulation requirements. High voltage is used in electrical power distribution, in cathode ray tubes, to generate X… …   Wikipedia

  • Switchgear — The term switchgear, used in association with the electric power system, or grid, refers to the combination of electrical disconnects, fuses and/or circuit breakers used to isolate electrical equipment. Switchgear is used both to de energize… …   Wikipedia

  • Transient Recovery Voltage — A transient recovery voltage (or TRV) for high voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high voltage circuit breaker, its… …   Wikipedia

  • Circuit breaker — For other uses, see Circuit breaker (disambiguation). An air circuit breaker for low voltage (less than 1000 volts) power distribution switchgear …   Wikipedia

  • List of IEC standards — In order to distinguish standards published by the International Electrotechnical Commission numerically from other international standards, their number range was shifted in 1997 by adding 60000. So what used to be called IEC 27 is now… …   Wikipedia

  • Appareillage electrique a haute tension — Appareillage électrique à haute tension Pour les articles homonymes, voir Appareillage (homonymie). Appareillage électrique 800 kV L appareillage électrique à haute ten …   Wikipédia en Français

  • Appareillage Électrique À Haute Tension — Pour les articles homonymes, voir Appareillage (homonymie). Appareillage électrique 800 kV L appareillage électrique à haute ten …   Wikipédia en Français

  • Appareillage à haute tension — Appareillage électrique à haute tension Pour les articles homonymes, voir Appareillage (homonymie). Appareillage électrique 800 kV L appareillage électrique à haute ten …   Wikipédia en Français

  • Appareillage électrique à haute tension — Pour les articles homonymes, voir Appareillage (homonymie). Appareillage électrique 800 kV L appareillage électrique à haute tension est l ensemble des appareils électriques qui permettent l …   Wikipédia en Français

  • Electrical substation — An electrical substation is a subsidiary station of an electricity generation, transmission and distribution system where voltage is transformed from high to low or the reverse using transformers. Electric power may flow through several… …   Wikipedia