Перевод: с русского на все языки

со всех языков на русский

dry+through

  • 101 длительный допустимый ток

    1. courant permanent admissible, m
    2. courant admissible, m

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-французский словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • Dry rot treatment — refers to the techniques used to eliminate dry rot fungus and alleviate the damage done by the fungus to human built wooden structures. The commonly held view of an outbreak of the dry rot fungus (Serpula lacrymans) within a building is that it… …   Wikipedia

  • Dry cleaning — (or dry cleaning) is any cleaning process for clothing and textiles using a chemical solvent other than water. The solvent used is typically tetrachloroethylene (perchloroethylene), abbreviated perc in the industry and dry cleaning fluid by the… …   Wikipedia

  • Dry Dock Complex (Detroit, Michigan) — Dry Dock Engine Works Detroit Dry Dock Company Complex U.S. National Register of Historic Places …   Wikipedia

  • Dry drowning — occurs when a person s lungs become unable to extract oxygen from the air, due primarily to: Muscular paralysis Puncture wound to the torso (affecting ability of diaphragm to create respiratory movement) Changes to the oxygen absorbing tissues… …   Wikipedia

  • Dry Kill Logic — Origin Westchester County, New York, United States Genres Nu metal, Alternative metal, Groove metal Years active 1993–present Labels Repossession (20 …   Wikipedia

  • Dry-Fly Fishing in Theory and Practice —   …   Wikipedia

  • Dry sump — A dry sump is a lubricating motor oil management method for four stroke and large two stroke piston internal combustion engines that uses external pumps and a secondary external reservoir for oil, as compared to a conventional wet sump system.… …   Wikipedia

  • Dry quicksand — is loose sand whose bulk density is reduced by blowing air through it and which yields easily to weight or pressure. It acts similarly to normal quicksand, but it does not contain any water and does not operate on the same principle. Dry… …   Wikipedia

  • Dry Creek (Sacramento River) — Dry Creek (formerly called Linda Creek) is a 15 mile (24 km) long stream in Placer County and Sacramento County, California, USA,[1] tributary to the Sacramento River. Its watershed lies within the Sacramento Valley..[2] Because suburban… …   Wikipedia

  • Dry As a Bone — EP by Green River Released July 1987 …   Wikipedia

  • Dry Dock Hotel — Public house information Location 22 Cameron Street, Balmain, NSW 2041. Established 1857 The Dry Dock Hotel is the oldest licensed …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»