  • 1 длительный допустимый ток

    1. courant permanent admissible, m
    2. courant admissible, m

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-французский словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • Designing with Web Standards — Designing with Web Standards[1] is a web development book by Jeffrey Zeldman (3rd edition with Ethan Marcotte). Zeldman co founded The Web Standards Project in 1998 and served as its director during the formative years when the Project was… …   Wikipedia

  • Designing Woman — Theatrical release poster Directed by Vincente Minnelli Produced by …   Wikipedia

  • Designing Virtual Worlds —   …   Wikipedia

  • Designing Women — This article is about the television show of this title. For the 1934 film of this title, see Designing Women (film). For the 1957 film with a similar title, see Designing Woman. Designing Women The original cast of Designing Women. Clockwise… …   Wikipedia

  • List of Designing Women episodes — The following is an episode list for the CBS sitcom Designing Women. The series began airing on September 29, 1986 and the final episode aired on May 24, 1993. During its seven year run, 163 Designing Women episodes were produced. In addition, a… …   Wikipedia

  • The Beauty Contest (Designing Women episode) — The Beauty Contest is the 2nd episode of the sitcom Designing Women . Originally airing on October 6, 1986, the episode was the first episode to follow the pilot. In some ways, the episode set the tone for several of the characters that would… …   Wikipedia

  • Strangers When We Meet (film) — Infobox Film name = Strangers When We Meet image size = caption = director = Richard Quine producer = Richard Quine Bryna Productions Richard Quine Productions writer = Evan Hunter narrator = starring = Kirk Douglas Kim Novak Ernie Kovacs Barbara …   Wikipedia

  • Coefficient of thermal expansion — When the temperature of a substance changes, the energy that is stored in the intermolecular bonds between atoms changes. When the stored energy increases, so does the length of the molecular bonds. As a result, solids typically expand in… …   Wikipedia

  • Social procedure — When writing code, a programmer does not have to worry that the computer may suddenly decide that the next instruction is not worth its time. However, when designing a social procedure in which individual agents are performing each instruction,… …   Wikipedia

  • Bubble point — When heating a liquid consisting of two or more components, the bubble point is the point where first bubble of vapor is formed. Given that vapor will probably have a different composition to the liquid, the bubble point (along with the dew… …   Wikipedia

  • Dance costumes — The purpose of a dance costume is to enhance the dancer’s body and the concept of the choreographer (Dance Catalog 219). “Costumes are clothes and they are art. They make the invisible ideas visible” (Nadel 241). Dance costume has evolved… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»