-
1 composante interharmonique
интергармоника
Интергармониками называют токи (напряжения) частота которых не кратна частоте основной гармоники.EN
interharmonic component
sinusoidal component of a periodic quantity having a an interharmonic frequency
NOTE 1 For brevity, such a component may be referred to simply as an interharmonic.
NOTE 2 For practical analysis, an approximation of the periodicity may be necessary.
NOTE 3 The value is normally expressed as an r.m.s. value.
NOTE 4 As stated in IEC 61000-4-7, the time window has a width of 10 fundamental periods (50 Hz systems) or 12 fundamental periods (60 Hz systems), i.e. approximately 200 ms. The difference in frequency between two consecutive interharmonic components is, therefore, approximately 5 Hz. In the case of other fundamental frequencies, the time window should be selected between 6 fundamental periods (approximately 1 000 ms at 6 Hz) and 18 fundamental periods (approximately 100 ms at 180 Hz).
[IEC 60146-1-1, ed. 4.0 (2009-06)]FR
composante interharmonique
composante sinusoïdale d’une grandeur périodique dont la fréquence est une fréquence interharmonique
NOTE 1 Pour des raisons de concision, ce type de composante peut être désigné simplement par le terme « interharmonique ».
NOTE 2 Pour l’analyse pratique, il peut être nécessaire de procéder à une approximation de la périodicité.
NOTE 3 La valeur est normalement exprimée comme une valeur efficace.
NOTE 4 Comme indiqué dans la CEI 61000-4-7, la fenêtre temporelle a une largeur de 10 périodes fondamentales (systèmes de 50 Hz) ou de 12 périodes fondamentales (systèmes de 60 Hz), c’est-à-dire approximativement 200 ms. La différence de fréquence entre deux composantes interharmoniques consécutives est, par conséquent, d’environ 5 Hz. Dans le cas d’autres fréquences fondamentales, il convient de choisir la fenêtre temporelle entre 6 périodes fondamentales (environ 1 000 ms à 6 Hz) et 18 périodes fondamentales (environ 100 ms à 180 Hz). [IEC 60146-1-1, ed. 4.0 (2009-06)]
Токи и напряжения интергармоник могут возникать как в низковольтных электрических сетях, так и в сетях среднего и высокого напряжения. Интергармоники, возникающие в электрических сетях среднего и высокого напряжения, передаются в питаемые ими низковольтные электрические сети. Возможен обратный процесс передачи интергармоник из электрических сетей низкого напряжения в сети среднего и высокого напряжения. [ ГОСТ Р 51317.4.13-2006]
На частотах, расположенных между частотами гармонических составляющих тока и напряжения, могут наблюдаться интергармоники. Интергармоники могут возникать на дискретных частотах или иметь спектральные составляющие в достаточно широкой полосе частот. Суммарное воздействие различных источников интергармоник маловероятно и в настоящем стандарте не учитывается.
Полного понимания природы электромагнитных возмущений, ассоциирующихся с интергармониками, еще нет, и в настоящее время к этому явлению возник повышенный интерес. Интергармоники всегда присутствуют в системе электроснабжения, но в последнее время с резким увеличением силовых электронных систем их практическое влияние стало более ощутимым.
[Збигнев Ханзелка (Zbigniew Hanzelka), Анжей Бьень (Andrzej Bien) AGH-UST, Краков, Республика Польша. Энергосбережение №7/2005]Тематики
Действия
Синонимы
EN
FR
интергармоническая составляющая
Составляющая на частоте интергармоники.
Значение интергармонической составляющей обычно выражается среднеквадратическим значением. Для краткости вместо термина "интергармоническая составляющая" допускается применение термина "интергармоника".
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
interharmonic component
component having an interharmonic frequency
NOTE Its value is normally expressed as an r.m.s. value. For brevity, such a component may be referred to simply as an interharmonic.
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
composante interharmonique
composante ayant une fréquence interharmonique
NOTE Sa valeur est en général exprimée sous la forme d’une valeur efficace. Pour des raisons de concision, cette composante peut être simplement appelée interharmonique
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
Синонимы
EN
FR
Франко-русский словарь нормативно-технической терминологии > composante interharmonique
-
2 déclencheur à manque de tension
минимальный расцепитель напряжения
Расцепитель, автоматически срабатывающий, когда подаваемое напряжение опускается ниже заданного уровня.
[ ГОСТ Р 50030.4.1-2002 (МЭК 60947-4-1-2000)]
минимальное реле или минимальной расцепитель напряжения
Реле или расцепитель, допускающие размыкание или замыкание контактного коммутационного аппарата с выдержкой времени или без нее, когда напряжение на выводах этого реле или расцепителя падает ниже заданной величины
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
under-voltage release
a shunt release which permits a mechanical switching device to open or close, with or without time-delay, when the voltage across the terminals of the release falls below a predetermined value.
[IEC 62271-100, ed. 2.0 (2008-04)
undervoltage release
release which causes a CBE to open, with or without delay, when the voltage across the terminals of the release falls below a predetermined value
[IEC 60934, ed. 3.0 (2000-10)]FR
déclencheur à minimum de tension
déclencheur shunt qui permet l’ouverture ou la fermeture, avec ou sans retard, d’un appareil mécanique de connexion lorsque la tension aux bornes du déclencheur tombe au-dessous d’une valeur prédéterminée.
[IEC 62271-100, ed. 2.0 (2008-04)]
déclencheur à manque de tension
déclencheur qui provoque l'ouverture du DPE avec ou sans retard, lorsque la tension aux bornes du déclencheur tombe au-dessous d'une valeur prédéterminée
[IEC 60934, ed. 3.0 (2000-10)]
Параллельные тексты EN-RU
The undervoltage trip automatically opens a circuit breaker when voltage drops to a value ranging between 35% to 70% of the line voltage.
The operation is instantaneous, and the circuit breaker cannot be reclosed until the voltage returns to 85% of line voltage.
Continuously energized, the undervoltage trip must be operating before the circuit breaker can be closed.
[LS Industrial Systems]Минимальный расцепитель напряжения вызывает срабатывание автоматического выключателя, если линейное напряжение защищаемой цепи падает до 35-70 % от номинального значения.
Срабатывание происходит мгновенно, после чего автоматический выключатель невозможно перевести во включенное положение до тех, пока линейное напряжение защищаемой цепи не повысится до 85 %.
Минимальный расцепитель постоянно находится под напряжением защищаемой цепи и всегда успевает сработать до того, как будет предпринята попытка включения автоматического выключателя.
[Перевод Интент]
В низковольтных автоматических выключателеях минимальный расцепитель напряжения является дополнительной принадлежностью, которая встраивается в гнездо автоматического выключателя
Дополнительные (электрические) принадлежности, встраиваемые в специальные гнезда автоматического выключателя:
1 - Левое гнездо;
2 - Автоматический выключатель;
3 - Правое гнездо.
Рис. LS Industrial SystemsНедопустимые, нерекомендуемые
Тематики
- выключатель автоматический
- расцепитель, тепловое реле
Классификация
>>>EN
- low-voltage release
- under voltage release
- under voltage trip
- under voltage trip coil
- under voltage trip device
- under voltage trip unit
- undervoltage release
- undervoltage trip
- undervoltage trip device
- undervoltage trip unit
- UVT
FR
Франко-русский словарь нормативно-технической терминологии > déclencheur à manque de tension
-
3 déclencheur à minimum de tension
минимальный расцепитель напряжения
Расцепитель, автоматически срабатывающий, когда подаваемое напряжение опускается ниже заданного уровня.
[ ГОСТ Р 50030.4.1-2002 (МЭК 60947-4-1-2000)]
минимальное реле или минимальной расцепитель напряжения
Реле или расцепитель, допускающие размыкание или замыкание контактного коммутационного аппарата с выдержкой времени или без нее, когда напряжение на выводах этого реле или расцепителя падает ниже заданной величины
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
under-voltage release
a shunt release which permits a mechanical switching device to open or close, with or without time-delay, when the voltage across the terminals of the release falls below a predetermined value.
[IEC 62271-100, ed. 2.0 (2008-04)
undervoltage release
release which causes a CBE to open, with or without delay, when the voltage across the terminals of the release falls below a predetermined value
[IEC 60934, ed. 3.0 (2000-10)]FR
déclencheur à minimum de tension
déclencheur shunt qui permet l’ouverture ou la fermeture, avec ou sans retard, d’un appareil mécanique de connexion lorsque la tension aux bornes du déclencheur tombe au-dessous d’une valeur prédéterminée.
[IEC 62271-100, ed. 2.0 (2008-04)]
déclencheur à manque de tension
déclencheur qui provoque l'ouverture du DPE avec ou sans retard, lorsque la tension aux bornes du déclencheur tombe au-dessous d'une valeur prédéterminée
[IEC 60934, ed. 3.0 (2000-10)]
Параллельные тексты EN-RU
The undervoltage trip automatically opens a circuit breaker when voltage drops to a value ranging between 35% to 70% of the line voltage.
The operation is instantaneous, and the circuit breaker cannot be reclosed until the voltage returns to 85% of line voltage.
Continuously energized, the undervoltage trip must be operating before the circuit breaker can be closed.
[LS Industrial Systems]Минимальный расцепитель напряжения вызывает срабатывание автоматического выключателя, если линейное напряжение защищаемой цепи падает до 35-70 % от номинального значения.
Срабатывание происходит мгновенно, после чего автоматический выключатель невозможно перевести во включенное положение до тех, пока линейное напряжение защищаемой цепи не повысится до 85 %.
Минимальный расцепитель постоянно находится под напряжением защищаемой цепи и всегда успевает сработать до того, как будет предпринята попытка включения автоматического выключателя.
[Перевод Интент]
В низковольтных автоматических выключателеях минимальный расцепитель напряжения является дополнительной принадлежностью, которая встраивается в гнездо автоматического выключателя
Дополнительные (электрические) принадлежности, встраиваемые в специальные гнезда автоматического выключателя:
1 - Левое гнездо;
2 - Автоматический выключатель;
3 - Правое гнездо.
Рис. LS Industrial SystemsНедопустимые, нерекомендуемые
Тематики
- выключатель автоматический
- расцепитель, тепловое реле
Классификация
>>>EN
- low-voltage release
- under voltage release
- under voltage trip
- under voltage trip coil
- under voltage trip device
- under voltage trip unit
- undervoltage release
- undervoltage trip
- undervoltage trip device
- undervoltage trip unit
- UVT
FR
Франко-русский словарь нормативно-технической терминологии > déclencheur à minimum de tension
-
4 interharmonique
интергармоника
Интергармониками называют токи (напряжения) частота которых не кратна частоте основной гармоники.EN
interharmonic component
sinusoidal component of a periodic quantity having a an interharmonic frequency
NOTE 1 For brevity, such a component may be referred to simply as an interharmonic.
NOTE 2 For practical analysis, an approximation of the periodicity may be necessary.
NOTE 3 The value is normally expressed as an r.m.s. value.
NOTE 4 As stated in IEC 61000-4-7, the time window has a width of 10 fundamental periods (50 Hz systems) or 12 fundamental periods (60 Hz systems), i.e. approximately 200 ms. The difference in frequency between two consecutive interharmonic components is, therefore, approximately 5 Hz. In the case of other fundamental frequencies, the time window should be selected between 6 fundamental periods (approximately 1 000 ms at 6 Hz) and 18 fundamental periods (approximately 100 ms at 180 Hz).
[IEC 60146-1-1, ed. 4.0 (2009-06)]FR
composante interharmonique
composante sinusoïdale d’une grandeur périodique dont la fréquence est une fréquence interharmonique
NOTE 1 Pour des raisons de concision, ce type de composante peut être désigné simplement par le terme « interharmonique ».
NOTE 2 Pour l’analyse pratique, il peut être nécessaire de procéder à une approximation de la périodicité.
NOTE 3 La valeur est normalement exprimée comme une valeur efficace.
NOTE 4 Comme indiqué dans la CEI 61000-4-7, la fenêtre temporelle a une largeur de 10 périodes fondamentales (systèmes de 50 Hz) ou de 12 périodes fondamentales (systèmes de 60 Hz), c’est-à-dire approximativement 200 ms. La différence de fréquence entre deux composantes interharmoniques consécutives est, par conséquent, d’environ 5 Hz. Dans le cas d’autres fréquences fondamentales, il convient de choisir la fenêtre temporelle entre 6 périodes fondamentales (environ 1 000 ms à 6 Hz) et 18 périodes fondamentales (environ 100 ms à 180 Hz). [IEC 60146-1-1, ed. 4.0 (2009-06)]
Токи и напряжения интергармоник могут возникать как в низковольтных электрических сетях, так и в сетях среднего и высокого напряжения. Интергармоники, возникающие в электрических сетях среднего и высокого напряжения, передаются в питаемые ими низковольтные электрические сети. Возможен обратный процесс передачи интергармоник из электрических сетей низкого напряжения в сети среднего и высокого напряжения. [ ГОСТ Р 51317.4.13-2006]
На частотах, расположенных между частотами гармонических составляющих тока и напряжения, могут наблюдаться интергармоники. Интергармоники могут возникать на дискретных частотах или иметь спектральные составляющие в достаточно широкой полосе частот. Суммарное воздействие различных источников интергармоник маловероятно и в настоящем стандарте не учитывается.
Полного понимания природы электромагнитных возмущений, ассоциирующихся с интергармониками, еще нет, и в настоящее время к этому явлению возник повышенный интерес. Интергармоники всегда присутствуют в системе электроснабжения, но в последнее время с резким увеличением силовых электронных систем их практическое влияние стало более ощутимым.
[Збигнев Ханзелка (Zbigniew Hanzelka), Анжей Бьень (Andrzej Bien) AGH-UST, Краков, Республика Польша. Энергосбережение №7/2005]Тематики
Действия
Синонимы
EN
FR
Франко-русский словарь нормативно-технической терминологии > interharmonique
-
5 courant admissible, m
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Франко-русский словарь нормативно-технической терминологии > courant admissible, m
-
6 courant permanent admissible, m
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Франко-русский словарь нормативно-технической терминологии > courant permanent admissible, m
-
7 haute tension
1
высокое напряжение
-
[IEV number 151-15-05]EN
high voltage (1)
high tension (1)
HV (1), abbreviation
voltage having a value above a conventionally adopted limit
NOTE – An example is the set of upper voltage values used in bulk power systems.
Source: 601-01-27 MOD
[IEV number 151-15-05]FR
haute tension (1), f
2
HT (1), abréviation
tension électrique de valeur supérieure à une limite adoptée par convention
NOTE – Un exemple est l'ensemble des tensions les plus élevées utilisées dans les réseaux de production-transport d'énergie électrique.
Source: 601-01-27 MOD
[IEV number 151-15-05]высокое напряжение
-EN
High Voltage
HV
systems with nominal voltage in range above 1 000 V a.c. and up to and including 15 kV a.c.
NOTE This definition differs from the conventional definition.
[IEC/PAS 60092-510, ed. 1.0 (2009-04)]FR
-
Синонимы
- ВН
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > haute tension
-
8 HT
1
высокое напряжение
-
[IEV number 151-15-05]EN
high voltage (1)
high tension (1)
HV (1), abbreviation
voltage having a value above a conventionally adopted limit
NOTE – An example is the set of upper voltage values used in bulk power systems.
Source: 601-01-27 MOD
[IEV number 151-15-05]FR
haute tension (1), f
2
HT (1), abréviation
tension électrique de valeur supérieure à une limite adoptée par convention
NOTE – Un exemple est l'ensemble des tensions les plus élevées utilisées dans les réseaux de production-transport d'énergie électrique.
Source: 601-01-27 MOD
[IEV number 151-15-05]высокое напряжение
-EN
High Voltage
HV
systems with nominal voltage in range above 1 000 V a.c. and up to and including 15 kV a.c.
NOTE This definition differs from the conventional definition.
[IEC/PAS 60092-510, ed. 1.0 (2009-04)]FR
-
Синонимы
- ВН
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > HT
-
9 courant de charge
зарядный ток конденсатора
Ток, проходящий через конденсатор при его зарядке.
[ ГОСТ 21415-75]Тематики
EN
DE
FR
ток нагрузки
-EN
load current
current flowing through the line conductor/s
[IEC 61557-13, ed. 1.0 (2011-07)]
load current
the r.m.s. value of the current in any winding under service conditions
[IEC 60076-1, ed. 3.0 (2011-04)]
load current
current to which the devices are subjected to produce power loss P
[IEC 60749-34, ed. 2.0 (2010-10)]FR
courant de charge
courant circulant à travers le (les) conducteur(s) de ligne
[IEC 61557-13, ed. 1.0 (2011-07)]
courant de charge
<>la valeur efficace vraie (r.m.s.) du courant dans tout enroulement en conditions de service
[IEC 60076-1, ed. 3.0 (2011-04)]
courant de charge
courant auquel sont soumis les dispositifs pour produire la perte de puissance P
[IEC 60749-34, ed. 2.0 (2010-10)]Параллельные тексты EN-RU
If it is left ON or OFF for a long time, it is recommended to switch load current on a regular basis.
[LS Industrial Systems]Если (автоматический выключатель) продолжительное время находится во включенном или отключенном состоянии, то рекомендуется периодически коммутировать этим выключателем ток нагрузки.
[Перевод Интент]Тематики
- электротехника, основные понятия
EN
FR
D. Ladestrom
E. Charging current
F. Courant de charge
Ток, проходящий через конденсатор при его зарядке
Источник: ГОСТ 21415-75: Конденсаторы. Термины и определения оригинал документа
Франко-русский словарь нормативно-технической терминологии > courant de charge
-
10 coupe-circuit à fusibles
плавкий предохранитель
Коммутационный аппарат, который посредством плавления одного или нескольких своих специально спроектированных и калиброванных элементов размыкает цепь, в которую он включен, и отключает ток, когда он превышает заданную величину в течение достаточного времени. Плавкий предохранитель содержит все части, образующие укомплектованный аппарат.
МЭК 60050(441-18-01).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
плавкий предохранитель
Аппарат, который вследствие расплавления одного или нескольких специально спроектированных и рассчитанных элементов размыкает цепь, в которую он включен, отключая ток, превышающий заданное значение в течение достаточно продолжительного времени. В состав плавкого предохранителя входят все части, образующие аппарат в комплекте
[ ГОСТ Р 50339. 0-2003 ( МЭК 60269-1-98)]
предохранитель
Коммутационный электрический аппарат, предназначенный для отключения защищаемой цепи посредством разрушения специально предусмотренных для этого токоведущих частей под действием тока, превышающего определенную величину.
[ ГОСТ 17703-72]
предохранитель
Устройство для разрыва электрических цепей при силе тока, превышающей допустимое значение
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]EN
fuse
a device that by the fusing of one or more of its specially designed and proportioned components, opens the circuit in which it is inserted by breaking the current when this exceeds a given value for a sufficient time. The fuse comprises all the parts that form the complete device
[IEV number 441-18-01 ]FR
fusible
coupe-circuit à fusibles
appareil dont la fonction est d'ouvrir par la fusion d'un ou de plusieurs de ses éléments conçus et calibrés à cet effet le circuit dans lequel il est inséré en coupant le courant lorsque celui-ci dépasse pendant un temps suffisant une valeur donnée. Le fusible comprend toutes les parties qui constituent l'appareil complet
[IEV number 441-18-01 ]Настоящий стандарт распространяется на плавкие предохранители на номинальный ток от 2 до 2500 А, номинальное напряжение переменного тока до 1000 В и постоянного тока до 1200 В, устанавливаемые в комплектные устройства и предназначенные для защиты при перегрузках и коротких замыканиях силовых и вспомогательных цепей электроустановок промышленных предприятий, общественных и жилых зданий, изготовляемые для нужд народного хозяйства и экспорта и номинальное напряжение до 3000 В для защиты полупроводниковых устройств.
3.2.14. Предохранители должны быть сконструированы таким образом, чтобы отключать электрическую цепь при токах отключения в пределах: от условного тока плавления — для предохранителей с плавкими вставками типов g и gR или от наименьшего тока отключения, установленного в стандартах или технических условиях на предохранители конкретных серий и типов, для предохранителей с плавкими вставками типов а и aR — до наибольшего тока отключения
[ ГОСТ 17242-86]... токи, при которых проводят испытания, предназначенные для проверки способности данного плавкого предохранителя срабатывать удовлетворительно в диапазоне малых сверхтоков.
[ ГОСТ Р 50339.0-2003]... Если неисправность заканчивается срабатыванием плавкого предохранителя или если плавкий предохранитель не срабатывает примерно в течение 1 с, то...
[ ГОСТ Р 52319-2005]ЭЛЕКТРИЧЕСКИЕ ПАРАМЕТРЫ И ХАРАКТЕНИСТИКИ ПРЕДОХРАНИТЕЛЕЙ
(взято из ГОСТ 17242-86)-
Для держателя (или основания) предохранителя:
- номинальное напряжение;
- номинальный ток;
- род тока и номинальная частота для переменного тока;
- допустимые потери мощности;
- число полюсов, если их более одного.
-
Для плавкой вставки:
- номинальное напряжение;
- номинальный ток;
- род тока и номинальная частота для переменного тока;
- потери мощности;
- время-токовые характеристики с указанием коэффициентов K1 и K2 для плавких вставок типа а;
- перегрузочная способность;
- диапазон токов отключения;
- наибольшая отключающая способность;
- наименьший ток отключения для плавких вставок типа а;
- характеристика пропускаемого тока;
- характеристики интегралов Джоуля;
- перенапряжение и характеристика перенапряжения для плавких вставок типов aR и gR;
- условия селективности (при необходимости);
- электрическое сопротивление плавкой вставки в холодном состоянии (допускается указать в рабочих чертежах, утвержденных в установленном порядке).
-
Для предохранителя:
- степень защиты по ГОСТ 14255—69;
- номинальное напряжение, номинальный ток и коммутационная способность свободных контактов (при их наличии).
Параллельные тексты EN-RU
Check to make sure that fuse F1 on power supply module V is not fused.
If the fuse is defective, it should not be replaced without determining the cause of failure.
If a fuse is replaced without eliminating the problem, there is the danger that the damage will spread.
[Schneider Electric]Убедитесь в исправности предохранителя F1 в модуле питания V.
Если предохранитель оказался неисправным, то прежде чем заменить его необходимо установить причину возникновения неисправности.
Замена предохранителя без выяснения причины его срабатывания может привести к повторению срабатывания.
[Перевод Интент]High voltage system may embrace a fuse.
Note that a fuse may not be manually adjusted as the circuit breaker relay does so the fuse choice for the appropriate purpose/circuit adaptation is deemed most important.
[LS Industrial Systems]Высоковольтная система < электропитания> может содержать предохранители.
Обратите внимание! Предохранитель нельзя настроить, как это можно сделать с расцепителем автоматического выключателя. Поэтому предохранитель необходимо выбрать так, чтобы он как можно точнее соотвествовал конкретным условиям защиты аппарата или участка цепи.
[Перевод Интент]
Тематики
Классификация
>>>Обобщающие термины
Действия
- защищать при перегрузках и коротких замыканиях
- отключать электрическую цепь
- срабатывание предохранителя
Синонимы
EN
- cutoff
- electric fuse
- fu
- fuse
- fuse switch
- fusible cutout
- fusible plug
- fusible switch
- plug fuse
- protective fuse
- safety cutoff
- safety fuse
- safety plug
- SF
- thermal fuse
DE
FR
Франко-русский словарь нормативно-технической терминологии > coupe-circuit à fusibles
-
Для держателя (или основания) предохранителя:
-
11 fusible
плавкий предохранитель
Коммутационный аппарат, который посредством плавления одного или нескольких своих специально спроектированных и калиброванных элементов размыкает цепь, в которую он включен, и отключает ток, когда он превышает заданную величину в течение достаточного времени. Плавкий предохранитель содержит все части, образующие укомплектованный аппарат.
МЭК 60050(441-18-01).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
плавкий предохранитель
Аппарат, который вследствие расплавления одного или нескольких специально спроектированных и рассчитанных элементов размыкает цепь, в которую он включен, отключая ток, превышающий заданное значение в течение достаточно продолжительного времени. В состав плавкого предохранителя входят все части, образующие аппарат в комплекте
[ ГОСТ Р 50339. 0-2003 ( МЭК 60269-1-98)]
предохранитель
Коммутационный электрический аппарат, предназначенный для отключения защищаемой цепи посредством разрушения специально предусмотренных для этого токоведущих частей под действием тока, превышающего определенную величину.
[ ГОСТ 17703-72]
предохранитель
Устройство для разрыва электрических цепей при силе тока, превышающей допустимое значение
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]EN
fuse
a device that by the fusing of one or more of its specially designed and proportioned components, opens the circuit in which it is inserted by breaking the current when this exceeds a given value for a sufficient time. The fuse comprises all the parts that form the complete device
[IEV number 441-18-01 ]FR
fusible
coupe-circuit à fusibles
appareil dont la fonction est d'ouvrir par la fusion d'un ou de plusieurs de ses éléments conçus et calibrés à cet effet le circuit dans lequel il est inséré en coupant le courant lorsque celui-ci dépasse pendant un temps suffisant une valeur donnée. Le fusible comprend toutes les parties qui constituent l'appareil complet
[IEV number 441-18-01 ]Настоящий стандарт распространяется на плавкие предохранители на номинальный ток от 2 до 2500 А, номинальное напряжение переменного тока до 1000 В и постоянного тока до 1200 В, устанавливаемые в комплектные устройства и предназначенные для защиты при перегрузках и коротких замыканиях силовых и вспомогательных цепей электроустановок промышленных предприятий, общественных и жилых зданий, изготовляемые для нужд народного хозяйства и экспорта и номинальное напряжение до 3000 В для защиты полупроводниковых устройств.
3.2.14. Предохранители должны быть сконструированы таким образом, чтобы отключать электрическую цепь при токах отключения в пределах: от условного тока плавления — для предохранителей с плавкими вставками типов g и gR или от наименьшего тока отключения, установленного в стандартах или технических условиях на предохранители конкретных серий и типов, для предохранителей с плавкими вставками типов а и aR — до наибольшего тока отключения
[ ГОСТ 17242-86]... токи, при которых проводят испытания, предназначенные для проверки способности данного плавкого предохранителя срабатывать удовлетворительно в диапазоне малых сверхтоков.
[ ГОСТ Р 50339.0-2003]... Если неисправность заканчивается срабатыванием плавкого предохранителя или если плавкий предохранитель не срабатывает примерно в течение 1 с, то...
[ ГОСТ Р 52319-2005]ЭЛЕКТРИЧЕСКИЕ ПАРАМЕТРЫ И ХАРАКТЕНИСТИКИ ПРЕДОХРАНИТЕЛЕЙ
(взято из ГОСТ 17242-86)-
Для держателя (или основания) предохранителя:
- номинальное напряжение;
- номинальный ток;
- род тока и номинальная частота для переменного тока;
- допустимые потери мощности;
- число полюсов, если их более одного.
-
Для плавкой вставки:
- номинальное напряжение;
- номинальный ток;
- род тока и номинальная частота для переменного тока;
- потери мощности;
- время-токовые характеристики с указанием коэффициентов K1 и K2 для плавких вставок типа а;
- перегрузочная способность;
- диапазон токов отключения;
- наибольшая отключающая способность;
- наименьший ток отключения для плавких вставок типа а;
- характеристика пропускаемого тока;
- характеристики интегралов Джоуля;
- перенапряжение и характеристика перенапряжения для плавких вставок типов aR и gR;
- условия селективности (при необходимости);
- электрическое сопротивление плавкой вставки в холодном состоянии (допускается указать в рабочих чертежах, утвержденных в установленном порядке).
-
Для предохранителя:
- степень защиты по ГОСТ 14255—69;
- номинальное напряжение, номинальный ток и коммутационная способность свободных контактов (при их наличии).
Параллельные тексты EN-RU
Check to make sure that fuse F1 on power supply module V is not fused.
If the fuse is defective, it should not be replaced without determining the cause of failure.
If a fuse is replaced without eliminating the problem, there is the danger that the damage will spread.
[Schneider Electric]Убедитесь в исправности предохранителя F1 в модуле питания V.
Если предохранитель оказался неисправным, то прежде чем заменить его необходимо установить причину возникновения неисправности.
Замена предохранителя без выяснения причины его срабатывания может привести к повторению срабатывания.
[Перевод Интент]High voltage system may embrace a fuse.
Note that a fuse may not be manually adjusted as the circuit breaker relay does so the fuse choice for the appropriate purpose/circuit adaptation is deemed most important.
[LS Industrial Systems]Высоковольтная система < электропитания> может содержать предохранители.
Обратите внимание! Предохранитель нельзя настроить, как это можно сделать с расцепителем автоматического выключателя. Поэтому предохранитель необходимо выбрать так, чтобы он как можно точнее соотвествовал конкретным условиям защиты аппарата или участка цепи.
[Перевод Интент]
Тематики
Классификация
>>>Обобщающие термины
Действия
- защищать при перегрузках и коротких замыканиях
- отключать электрическую цепь
- срабатывание предохранителя
Синонимы
EN
- cutoff
- electric fuse
- fu
- fuse
- fuse switch
- fusible cutout
- fusible plug
- fusible switch
- plug fuse
- protective fuse
- safety cutoff
- safety fuse
- safety plug
- SF
- thermal fuse
DE
FR
Франко-русский словарь нормативно-технической терминологии > fusible
-
Для держателя (или основания) предохранителя:
-
12 courant de déclenchement instantané (d'un disjoncteur)
ток мгновенного расцепления Ii
Значение тока, выше которого автоматический выключатель для электрооборудования должен автоматически сработать (без намеренной выдержки времени) в течение менее 0,1 с.
[ ГОСТ Р 50031-99( МЭК 60934-93)]
ток мгновенного расцепления
Минимальное значение тока, вызывающее срабатывание выключателя без выдержки времени
[ ГОСТ Р 50345-99( МЭК 60898-95)]EN
instantaneous tripping current (of a circuit-breaker)
the value of current above which the circuit-breaker will operate automatically without intentional time-delay
[IEV number 442-05-46]FR
courant de déclenchement instantané (d'un disjoncteur)
Примечание
valeur du courant au-dessus de laquelle le fonctionnement automatique d'un disjoncteur a lieu sans temporisation intentionnelle
[IEV number 442-05-46]
Более подробно о токе мгновенного расцепления см. " защитная характеристика автоматического выключателя"
Параллельные тексты EN-RUIn addition, the core loss decreases attractive force, which leads to increase of instantaneous trip current.
[LS Industrial Systems]Кроме того, потери в магнитной системе уменьшают силу притяжения, что приводит к увеличению тока мгновенного расцепления.
[Перевод Интент]Тематики
Синонимы
- Ii
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > courant de déclenchement instantané (d'un disjoncteur)
-
13 structure économique
экономическая структура
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]EN
economic structure
The underlying framework, including transportation and communications systems, industrial facilities, education and technology, that enables a country or region to produce goods, services and other resources with exchange value. (Source: MGHME / RHW)
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > structure économique
См. также в других словарях:
value-systems — value … Dictionary of sociology
Naturalization of value systems — The naturalization of value systems in the human sciences is the process by which other frameworks were sought to replace spiritual, other worldly , religious explanations of nature, life and humanity with respect to fundamental values.… … Wikipedia
value system — value systems N COUNT The value system of a group of people is the set of beliefs and attitudes that they all share … English dictionary
Value system — A value system is a set of consistent ethic values (more specifically the personal and cultural values) and measures used for the purpose of ethical or ideological integrity. A well defined value system is a moral code. Personal and communal One… … Wikipedia
value system — noun a) A hierarchy of values that all moral agents possess, demonstrated by their choices. Most peoples value systems differ, making the imposition of a singular value system by the state a source of constant social warfare. This is an… … Wiktionary
systems engineering — ☆ systems engineering n. a branch of engineering using esp. information theory, computer science, and facts from systems analysis studies to design integrated operational systems for specific complexes systems engineer n. * * * Technique of using … Universalium
Value network analysis — is a methodology for understanding, using, visualizing, optimizing internal and external value networks and complex economic ecosystems. The methods include visualizing sets of relationships from a dynamic whole systems perspective. Robust… … Wikipedia
Systems engineering — is an interdisciplinary field of engineering that focuses on how complex engineering projects should be designed and managed. Issues such as logistics, the coordination of different teams, and automatic control of machinery become more difficult… … Wikipedia
Value added — refers to the additional value of a commodity over the cost of commodities used to produce it from the previous stage of production. An example is the price of gasoline at the pump over the price of the oil in it. In national accounts used in… … Wikipedia
Value of information — (VoI) in decision analysis is the amount a decision maker would be willing to pay for information prior to making a decision. imilar termsVoI is sometimes distinguished into value of perfect information, also called value of clairvoyance (VoC),… … Wikipedia
Value capture — refers to a type of innovative public financing in which increases in private land values generated by a new public investment are all or in part “captured” through a land related tax to pay for that investment or other public projects. Value… … Wikipedia