Перевод: со всех языков на все языки

со всех языков на все языки

tripping+current

  • 121 время-токовая характеристика

    1. tripping curve
    2. tripping characteristic
    3. trip curve characteristic
    4. trip curve
    5. trip characteristic
    6. time-current characteristic
    7. T-C curve
    8. characteristic curve

     

    время-токовая характеристика
    Кривая, отражающая взаимосвязь времени, например преддугового или рабочего, и ожидаемого тока в указанных условиях эксплуатации.
    МЭК 60050 (441-17-13).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    EN

    time-current characteristic
    a curve giving the time, e.g. pre-arcing time or operating time, as a function of the prospective current under stated conditions of operation
    [IEV number 441-17-13]

    FR

    caractéristique temps-courant
    courbe donnant la durée, par exemple durée de préarc ou durée de fonctionnement, en fonction du courant présumé dans des conditions déterminées de fonctionnement
    [IEV number 441-17-13]

    0225 Время-токовая характеристика представляет собой зависимость времения срабатывания автоматического выключателя от тока, протекающего в его главной цепи.
    На рисунке представлена типичная время-токовая характеристика автоматического выключателя.
    По оси ординат отложено время срабатывания автоматического выключателя в секундах.
    По оси абсцисс — отношение тока, протекающего в главной цепи автоматического выключателя к номинальному току.
    Из графика видно, что при значении I/Iн≤1 время отключения автоматического выключателя стремится к бесконечности.
    Иными словами, до тех пор, пока ток, протекающий в главной цепи автоматического выключателя, меньше или равен номинальному току, автоматический выключатель не отключится.
    Из графика также видно, что чем больше значение I/Iн, тем быстрее автоматический выключатель отключится. Так, например, (для левой кривой) при значении I/Iн=7 автоматический выключатель отключится через 0,1 секунды, а при I/Iн=3 - через 20 секунд.

    [Интент]

    0226
    Рис. Legrand   В автоматических выключателях с микропроцессорным расцепителем время-токовая характеристика имеет вид, представленный на рисунке и ее можно настраивать.
    В такой время-токовой характеристике различают три зоны срабатывания:
    - « Большая задержка». Эта зона соответствует тепловому расцепителю и защищает цепь от перегрузки;
    - « Малая задержка». Это защита от «слабых» коротких замыканий (обычно в конце защищаемой линий). Порог срабатывания, как правило, можно настроить. За счет изменения порога срабатывания можно увеличить время задержки до 1 секунды, что используется для обеспечения надежной селективности срабатывания относительно расположенных ниже аппаратов защиты;
    - « Мгновенно». Это защита от «мощных» коротких замыканий. Порог срабатывания устанавливается при изготовлении и зависит от модели автоматического выключателя.

    Примечание
    . Представленная на рисунке характеристика называется также
    трехступенчатой защитной характеристикой. См. " защитная характеристика автоматического выключателя"

    [Интент]

    Тематики

    Синонимы

    EN

    DE

    • Zeit/Strom-Kennlinie

    FR

    Русско-английский словарь нормативно-технической терминологии > время-токовая характеристика

  • 122 характеристика расцепления

    1. tripping characteristic (of a circuit-breaker)

     

    характеристика расцепления
    -
    [IEV number 442-05-47]


    характеристика расцепления
    Время-токовая характеристика, выше которой автоматический выключатель для электрооборудования должен сработать.
    [ ГОСТ Р 50031-99( МЭК 60934-93)]
    время-токовая характеристика коммутационного аппарата
    Зависимость времени срабатывания коммутационного аппарата от тока в его главной цепи.
    [ ГОСТ 17703-72]

    EN

    tripping characteristic (of a circuit-breaker)
    the time-current characteristic above which the circuit-breaker shall trip
    [IEV number 442-05-47]

    FR

    caractéristique de déclenchement (d'un disjoncteur)
    caractéristique temps-courant au-dessus de laquelle le disjoncteur doit déclencher
    [IEV number 442-05-47]

    Тематики

    Синонимы

    EN

    DE

    FR

    Русско-английский словарь нормативно-технической терминологии > характеристика расцепления

  • 123 расцепитель

    расцепи́тель м. эл.
    release, trip, release [tripping] mechanism, release [tripping] device
    авари́йный расцепи́тель — emergency release [tripping] device
    магни́тный расцепи́тель — magnetic release [tripping] device
    расцепи́тель максима́льного то́ка — overcurrent release [tripping] device
    максима́льный расцепи́тель — maximum-current release [tripping] device
    минима́льный расцепи́тель — minimum-current release [tripping] device
    расцепи́тель обра́тного то́ка — reverse-current release [tripping] device
    расцепи́тель с вы́держкой вре́мени — delayed release, delayed trip
    теплово́й расцепи́тель — thermal release [tripping] device
    * * *

    Русско-английский политехнический словарь > расцепитель

  • 124 реле (p) (к)


    relay (к)
    электромеханическое устройство, контакты которого размыкают и /или замыкают управляемую цепь в зависимости от наличия или величины эл. сигналов в управляющей цепи, — an electromechanical device in which contacts are opened and/or closed by variations in the conditions of one electric circuit and thereby affect the operation of other devices in the same or other electric circuits.
    -, арретирующее — latching relay
    -, барометрическое (барореле для раскрытия парашюта) — barometric release (mechanism)
    -, бесконтактное — contactless relay
    - блокировкиblocking relay
    -, биметаллическое — bimetallic relay
    - блокировки (выключения)lockout relay
    - блокировки (выключения) автомата торможенияanti-skid lockout relay
    - блокировки включения систем самолета, двигателя при обжатой передней амортстойке шасси — ground shift relay (actuated with nose oleo compressed)
    -, блокировочное — blocking relay
    реле, связанное с другими устройствами и, служащее для предотвращения срабатывания ипи повторного включения цепи при нарушении нормальной работы. — a relay wtlich со-operates with other devices to block tripping or to block reclosing on an out-of-step condition. or on power swings.
    -, блокировочное — locking-out /lockout/ relay
    реле, служащее для выключения оборудования и удержания его в выключенном состоянии при нарушении нормальной работы.данного оборудования, — an electrically operated hand or electrically reset device which functions to shut down and hold an equipment out of service on occurrence of abnormal conditions.
    - включения (и выключения)switching relay
    реле, включающее или выключающее к-л. устройство или цепь, — the relay which can place another device or circuit in an operating or nonoperating state.
    - включения (одного устройства к другому, напр., преобразователя к шине) — (inverter-to-bus) switching /connection, tie/ relay
    - включения муфты стартераstarter meshing relay
    - включения наземного питанияexternal power relay
    - включения стартерного pежима (стартера-генератора)motorizing relay
    - времениtime relay
    - времени, электромашинное — rotary time-delay relay
    -, вызывающее срабатывание системы (цепи) — system /circuit/ actuating relay
    -, выключающее — cutout /cut-out/ relay
    - выключения (защитного устройства, контактора, оборудования) — tripping relay. used to trip а circuit breaker, contactor, equipment.
    - выключения (блокировки оборудования при нарушении нормальных условий работы) — lock-out relay
    - выключения зажигания (двиг.) — ignition cut-out relay
    -, герметическое — pressure sealed relay
    -, гидравлическое (сигнализатор) — hydraulic pressure switch
    - давления (сигнализатор давления)pressure switch
    реле, срабатывающее при изменении давления подводимого газа или жидкости — a switch actuated by а change in the pressure of a gas or liquid.
    - двухпозиционное (е замыканием контактов в двух крайних положениях) — double-throw relay. а relay which alternately completes а circuit at either of its two extreme positions.
    -, двухполюсное — double pole relay
    динамического торможения (фотокамеры)(camera) dynamic braking relay
    - дифференциальноеdifferential relay
    реле с несколькими обмотками, которое срабатывает, когда разность величин подводимого напряжения или протекающего тока в обмотках достигает определенного уровня. — a relay with multiple windings that functions when the voltage, current, or power difference between the windings reaches а predetermined value.
    -, дифференциально-минимальное (дмр) — differential reverse current cutout relay
    - задержки времениtime delay relay
    реле, обеспечивающее временной интервал между включением и выключением обмотки и перемещением якоря, — a relay in which there is an appreciable interval of time between the energizing or deenergizing of the coil and the movement of the armature.
    -, защитное — protective relay
    реле, служащее для защиты цепей в случае нарушения нормального режима работы, — a relay, the principal function оf which is to protect services from interruption or to prevent or limit damage to apparatus.
    -, защитное дифференциальнoe — differential protective relay
    - защиты от перенапряженияovervoltage relay
    -, командное — control relay
    - контроля нагрузкиload monitor relay (lmr)
    -, максимальное — overload relay
    реле, срабатывающее, если сила тока, протекающего в его обмотке, превышает установленную величину, — a relay designed to operate when its coil current rises above а predetermined value.
    - мгновенного действияinstantaneous relay
    -, минимальное — reverse current (cut-out) relay
    устанавливается в цепи между генератором пост. тока (или выпрямительным устройством) и шиной пост. тока для предотвращения обратного тока в случае, если напряжение на шине превышает выходное напряжение генератора. — reverse current cut-out relays are placed between the dc generator, transformerrectifier, and the dc bus to prevent reverse current flow, if the dc bus potential becomes greater than dc generator or transformerrectifier output.
    - на два направления (двухпозиционное)double-throw relay
    - напряженияvoltage relay
    реле, срабатывающее при заданной величине подаваемого напряжения, — a relay that functions at а predetermined value of voltage.
    - обжатого положения шасси (для включения систем ла)ground shift mechanism relay
    - обратного токаreverse-current relay
    реле, срабатывающее при протекании тока в обратном направлении, — a relay that operates whenever current flows in the reverse direction.
    - объединения шин (подсистем лев. и прав. борта) — bus tie relay (btr)
    - отключения объединения шинtie bus isolation relay
    - перегрузки (максимальное)overload relay
    - переключения потребителей (pпп)load monitor relay (lmr)
    - переключения стартера-генератора на стартерный режимmotorizing relay
    - переключения шин (эл.) — bus tie relay (btr)
    - переменного токаас operated relay
    -, пневматическое (сигнализатор давления) — pneumatic pressure switch
    - подает напряжение на... — relay applies voltage to..., relay energizes...
    - подает (+27 в) на... — relay applies (+27 v) to..., relay makes /closes/ circuit to supply /apply, feed/ +27 v to...
    -, поляризованное — polarized relay
    реле, направление перемещения якоря которого зависит от направления тока в его обмотке. — а relay in which the arma'ture movement depends on the direction of the current. its coil symbol is sometimes marked +.
    - предельного значения скоростиmaximum operating limit speed relay
    - предельного значения числa m. — maximum operating limit mach-number relay
    -, промежуточное (вспомогательное) — auxiliary relay
    - пускового зажигания (двиг.) — starting ignition.relay
    -, развязывающее — decoupling relay
    -, разделительное — isolation relay
    - сигнализатора обледененияice detector pressure switch
    - сигнализации достижения предельной скоростиmaximum operating limit speed (warning) relay
    - сигнализации нарушения (параметров) питания — power relay. it may be an overpower or underpower relay.
    - сигнализации отказа питанияpower fail relay
    - с механической блокировкойlatching relay
    - соединения шинbus tie relay (btr)
    - с самоблокировкойinterlock relay
    реле, в котором один якорь не может изменить свое положение или его обмотка не может оказаться под током, если другой якорь не занимает определенное положение. — a relay in which one armature cannot move or its coil be energized unless the other armature is in a certain position.
    -, стопорное (запорное) — latch-in /latching, locking/ relay
    реле, контакты которого стопорятся (фиксируются) либо в замкнутом или разомкнутом положении до момента расстопорения вручную или электрически. — а relay with contacts that lock in oither the energized or de-energized position until reset either manually or electrlcally.
    - стрельбы — firing control relay, fire relay
    - снимает напряжение с... (обесточивает цепь) — relay de-energizes..., relay removes voltage from...
    - снимает +27 в с... — rela@ removes +27 v from..., relay breakes /opens/ circuit to remove +27 v from...
    - срабатывает (и замыкает цепь)relay operates (and closes circuit)
    - срабатывает и (своими контактами) подает +27 в на клемму 1 — relay operates and applies +27 v to terminal 1
    - срабатывает и приводит в действие эл. мотор — relay actuates electric motor
    -, струйное
    электромагнитное устройство, распределяющее входное давление (воздуха, рабочей жидкости) в двух выходных каналах. — jet relay
    -, тепловое — thermal relay
    реле, срабатывающее под воздействием нагрева, создаваемого протекаемым током. — а relay (hat responds to the heating effect of an energizing current.
    -, управляющее — control relay
    -, чувствительное — sensitive relay
    -, шаговое — stepping relay
    -, электромагнитное — electromagnetic relay
    электромагнитный контактор, имеющий обмотку (обмотки) и подвижный якорь, — an electromagnetically operated switch composed of one or more coils and armatures.
    -, эпектромашинное — rotary relay
    -, электронное — electronic relay
    электронная цепь, выполняющая функцию реле, без наличия подвижных деталей. — an electronic circuit that provides the functional equivalent of a relay, but has no moving parts.
    отпускание p. (на размыкание контактов) — tripping off
    срабатывание р. — operation of relay
    включать р. — energize relay
    выключать (обесточивать) р. — de-energize relay
    переключать(ся) р. — reset relay (manually or electrically)
    - притягивать якорь р. — attract relay armature
    удерживать р. в заданном положении — hold relay in the given position

    Русско-английский сборник авиационно-технических терминов > реле (p) (к)

  • 125 НКУ с устройствами ограничения воздействия внутренней дуги

    1. assembly equipped with devices limiting internal arc effects

     

    НКУ с устройствами ограничения воздействия внутренней дуги
    -
    [Интент]

    Параллельные тексты EN-RU

    Assemblies equipped with devices limiting internal arc effects (active protection)

    A design philosophy which is completely different from that just considered consists in guaranteeing the resistance to internal arcing by installing devices limiting the arc.

    The approaches in that direction can be of two different types:
    • limiting the destructive effects of the arc, once it has occured, by means of arc detectors
    • limiting the destructive effects of the arc, once it has occured, by means of overpressure detectors.

    The first possibility consists in installing in the assembly arc detectors which sense the light flux associated with the electric arc phenomenon.

    Once the arc has been detected, these devices send an opening signal to the incoming circuit-breaker, thus guaranteeing tripping times of the order of 1-2 ms, therefore shorter than those proper of the circuit-breaker.

    The operating logic of an arc detector is the following: the occurrence of an arc inside the switchboard is detected by the arc detector because an intense light radiation is associated with this phenomenon.

    The arcing control system detects the event and sends a tripping signal to the circuit-breaker.

    All the above with trip times of a few milliseconds and supplanting the tripping of the CB overcurrent relay which, for example, could be delayed due to current selectivity questions.

    Figure 1 shows the possible positions where this device can be installed inside a switchboard.

    The ideal solution is that which provides the installation of at least one detector for each column, with the consequent reduction to a minimum of the length of the optical fibers carrying the signal.

    In order to prevent from an unwanted tripping caused by light sources indepent of the arc (lamps, solar radiation etc.), an additional current sensor is often positioned at the incoming of the main circuit-breaker.

    Only in the event of an arc, both the incoming sensor which detects an “anomalous” current due to the arc fault as well as the sensor detecting the light radiation as sociated with the arc enable the system to intervene and allow the consequent opening of the circuit-breaker.

    The second possibility consists in installing overpressure sensors inside the switchboard.

    As previously described, the overpressure wave is one of the other effects occurring inside an assembly in case of arcing.

    As a consequence it is possible to install some pressure sensors which are able to signal the pressure peak associated with the arc ignition with a delay of about 10-15 ms.

    The signal operates on the supply circuit-breaker without waiting for the trip times of the selectivity protections to elapse, which are necessarily longer.

    Such a system does not need any electronic processing device, since it acts directly on the tripping coil of the supply circuit-breaker.

    Obviously it is essential that the device is set at fixed trip thresholds.

    When an established internal overpressure is reached, the arc detector intervenes.

    However, it is not easy to define in advance the value of overpressure generated by an arc fault inside a switchboard.

    [ABB]

    НКУ с устройствами ограничения воздействия внутренней дуги (активная защита)

    Для решения этой задачи используются совершенно другие, отличающиеся от ранее рассмотренных, принципы, заключающиеся в том, что противодействие внутренней дуге обеспечивается применением устройств, ограничивающих саму дугу.

    Существует два типа решения проблемы в этом направлении:
    • ограничение разрушающего воздействия дуги после того, как ее обнаружат специальные устройства
    • ограничение разрушающего воздействия дуги после того, как специальные устройства обнаружат возникновение избыточного давления.

    В первом случае в НКУ устанавливают устройства обнаружения дуги, реагирующие на световой поток, сопровождающий явление электрической дуги.

    При обнаружении дуги данные устройства посылают сигнал управления на размыкание вводного автоматического выключателя. Гарантируемое время реакции составляет 1-2 мс, что меньше времени срабатывания автоматического выключателя.

    Логика работы устройства обнаружения дуги следующая: Дуга, возникшая внутри НКУ, обнаруживается датчиком, реагирующим на интенсивное световое излучение, которым сопровождается горение дуги.

    Обнаружив дугу, система управления посылает сигнал автоматическому выключателю.

    Время срабатывания датчика и системы управления составляет несколько миллисекунд, что меньше времени срабатывания автоматического выключателя, осуществляющего защиту от сверхтока, который обычно для обеспечения требуемой селективности срабатывает с задержкой.

    На рис. 1 показаны места возможной установки устройства защиты внутри НКУ.

    Идеальным решением является установка, по крайней мере, одного устройства защиты в каждый шкаф многошкафного НКУ.

    Это позволит до минимума сократить длину оптоволоконных кабелей передачи сигнала.

    Для предотвращения ложного срабатывания от других источников света (т. е. не от дуги), например, таких как лампы, солнечное излучение и т. п., дополнительно в главной цепи вводного автоматического выключателя устанавливают датчик тока.

    Только при наличии двух событий, а именно: срабатывания датчика света и обнаружения аномального увеличения тока, система управления считает, что возникла электрическая дуга и подает команду на отключение вводного автоматического выключателя.

    Второе решение заключается в установке внутри НКУ датчика избыточного давления.

    Как было описано ранее, одним из характерных проявлений электрической дуги, возникшей внутри НКУ, является ударная волна.

    Это означает, что можно установить несколько датчиков давления, задачей которых является обнаружение импульса давления (с задержкой 10…15 мс), обусловленного зажиганием дуги.

    Сигнал от датчиков давления поступает на вводной автоматический выключатель, который срабатывает без задержки на обеспечение селективности.

    Такая система не нуждается в электронном устройстве обработки информации, поскольку воздействует непосредственно на независимый расцепитель автоматического выключателя.

    Вполне понятно, что такое устройство имеет фиксированный порог срабатывания.

    Датчик-реле дуги сработает, как только будет достигнуто заданное значение избыточного давления.

    Следует иметь в виду, что не так легко заранее определить значение избыточного давления, которое будет создано при зажигании дуги внутри НКУ.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    Русско-английский словарь нормативно-технической терминологии > НКУ с устройствами ограничения воздействия внутренней дуги

  • 126 assembly equipped with devices limiting internal arc effects

    1. НКУ с устройствами ограничения воздействия внутренней дуги

     

    НКУ с устройствами ограничения воздействия внутренней дуги
    -
    [Интент]

    Параллельные тексты EN-RU

    Assemblies equipped with devices limiting internal arc effects (active protection)

    A design philosophy which is completely different from that just considered consists in guaranteeing the resistance to internal arcing by installing devices limiting the arc.

    The approaches in that direction can be of two different types:
    • limiting the destructive effects of the arc, once it has occured, by means of arc detectors
    • limiting the destructive effects of the arc, once it has occured, by means of overpressure detectors.

    The first possibility consists in installing in the assembly arc detectors which sense the light flux associated with the electric arc phenomenon.

    Once the arc has been detected, these devices send an opening signal to the incoming circuit-breaker, thus guaranteeing tripping times of the order of 1-2 ms, therefore shorter than those proper of the circuit-breaker.

    The operating logic of an arc detector is the following: the occurrence of an arc inside the switchboard is detected by the arc detector because an intense light radiation is associated with this phenomenon.

    The arcing control system detects the event and sends a tripping signal to the circuit-breaker.

    All the above with trip times of a few milliseconds and supplanting the tripping of the CB overcurrent relay which, for example, could be delayed due to current selectivity questions.

    Figure 1 shows the possible positions where this device can be installed inside a switchboard.

    The ideal solution is that which provides the installation of at least one detector for each column, with the consequent reduction to a minimum of the length of the optical fibers carrying the signal.

    In order to prevent from an unwanted tripping caused by light sources indepent of the arc (lamps, solar radiation etc.), an additional current sensor is often positioned at the incoming of the main circuit-breaker.

    Only in the event of an arc, both the incoming sensor which detects an “anomalous” current due to the arc fault as well as the sensor detecting the light radiation as sociated with the arc enable the system to intervene and allow the consequent opening of the circuit-breaker.

    The second possibility consists in installing overpressure sensors inside the switchboard.

    As previously described, the overpressure wave is one of the other effects occurring inside an assembly in case of arcing.

    As a consequence it is possible to install some pressure sensors which are able to signal the pressure peak associated with the arc ignition with a delay of about 10-15 ms.

    The signal operates on the supply circuit-breaker without waiting for the trip times of the selectivity protections to elapse, which are necessarily longer.

    Such a system does not need any electronic processing device, since it acts directly on the tripping coil of the supply circuit-breaker.

    Obviously it is essential that the device is set at fixed trip thresholds.

    When an established internal overpressure is reached, the arc detector intervenes.

    However, it is not easy to define in advance the value of overpressure generated by an arc fault inside a switchboard.

    [ABB]

    НКУ с устройствами ограничения воздействия внутренней дуги (активная защита)

    Для решения этой задачи используются совершенно другие, отличающиеся от ранее рассмотренных, принципы, заключающиеся в том, что противодействие внутренней дуге обеспечивается применением устройств, ограничивающих саму дугу.

    Существует два типа решения проблемы в этом направлении:
    • ограничение разрушающего воздействия дуги после того, как ее обнаружат специальные устройства
    • ограничение разрушающего воздействия дуги после того, как специальные устройства обнаружат возникновение избыточного давления.

    В первом случае в НКУ устанавливают устройства обнаружения дуги, реагирующие на световой поток, сопровождающий явление электрической дуги.

    При обнаружении дуги данные устройства посылают сигнал управления на размыкание вводного автоматического выключателя. Гарантируемое время реакции составляет 1-2 мс, что меньше времени срабатывания автоматического выключателя.

    Логика работы устройства обнаружения дуги следующая: Дуга, возникшая внутри НКУ, обнаруживается датчиком, реагирующим на интенсивное световое излучение, которым сопровождается горение дуги.

    Обнаружив дугу, система управления посылает сигнал автоматическому выключателю.

    Время срабатывания датчика и системы управления составляет несколько миллисекунд, что меньше времени срабатывания автоматического выключателя, осуществляющего защиту от сверхтока, который обычно для обеспечения требуемой селективности срабатывает с задержкой.

    На рис. 1 показаны места возможной установки устройства защиты внутри НКУ.

    Идеальным решением является установка, по крайней мере, одного устройства защиты в каждый шкаф многошкафного НКУ.

    Это позволит до минимума сократить длину оптоволоконных кабелей передачи сигнала.

    Для предотвращения ложного срабатывания от других источников света (т. е. не от дуги), например, таких как лампы, солнечное излучение и т. п., дополнительно в главной цепи вводного автоматического выключателя устанавливают датчик тока.

    Только при наличии двух событий, а именно: срабатывания датчика света и обнаружения аномального увеличения тока, система управления считает, что возникла электрическая дуга и подает команду на отключение вводного автоматического выключателя.

    Второе решение заключается в установке внутри НКУ датчика избыточного давления.

    Как было описано ранее, одним из характерных проявлений электрической дуги, возникшей внутри НКУ, является ударная волна.

    Это означает, что можно установить несколько датчиков давления, задачей которых является обнаружение импульса давления (с задержкой 10…15 мс), обусловленного зажиганием дуги.

    Сигнал от датчиков давления поступает на вводной автоматический выключатель, который срабатывает без задержки на обеспечение селективности.

    Такая система не нуждается в электронном устройстве обработки информации, поскольку воздействует непосредственно на независимый расцепитель автоматического выключателя.

    Вполне понятно, что такое устройство имеет фиксированный порог срабатывания.

    Датчик-реле дуги сработает, как только будет достигнуто заданное значение избыточного давления.

    Следует иметь в виду, что не так легко заранее определить значение избыточного давления, которое будет создано при зажигании дуги внутри НКУ.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    Англо-русский словарь нормативно-технической терминологии > assembly equipped with devices limiting internal arc effects

  • 127 время-токовая характеристика срабатывания устройства защитного отключения по дифференциальному току

    1. residual current tripping curve
    2. curve of tripping time in terms of residual current

     

    время-токовая характеристика срабатывания устройства защитного отключения по дифференциальному току

    [Интент]

    Тематики

    EN

    Русско-английский словарь нормативно-технической терминологии > время-токовая характеристика срабатывания устройства защитного отключения по дифференциальному току

  • 128 breaker

    English-Russian electronics dictionary > breaker

См. также в других словарях:

  • tripping current — suveikimo srovė statusas T sritis automatika atitikmenys: angl. operating current; operative current; tripping current vok. Ansprechstrom, m rus. ток срабатывания, m pranc. courant de déclenchement, m; courant de fonctionnement, m …   Automatikos terminų žodynas

  • tripping current — suveikimo srovė statusas T sritis fizika atitikmenys: angl. minimum working current; operative current; tripping current vok. Ansprechstrom, m; Ansprechstromstärke, f rus. ток срабатывания, m pranc. courant de déclenchement, m; courant minimum de …   Fizikos terminų žodynas

  • Tripping the Light Fantastic (album) — Infobox Album | Name = Tripping the Light Fantastic Type = Album Artist = Lit Released = April 1, 1997 Recorded = Genre = Post grunge Length = 41:14 Label = Malicious Vinyl Producer = Lit and Matt Gruber Reviews = *Allmusic Rating|4|5 [http://www …   Wikipedia

  • operating current — suveikimo srovė statusas T sritis automatika atitikmenys: angl. operating current; operative current; tripping current vok. Ansprechstrom, m rus. ток срабатывания, m pranc. courant de déclenchement, m; courant de fonctionnement, m …   Automatikos terminų žodynas

  • operative current — suveikimo srovė statusas T sritis automatika atitikmenys: angl. operating current; operative current; tripping current vok. Ansprechstrom, m rus. ток срабатывания, m pranc. courant de déclenchement, m; courant de fonctionnement, m …   Automatikos terminų žodynas

  • minimum working current — suveikimo srovė statusas T sritis fizika atitikmenys: angl. minimum working current; operative current; tripping current vok. Ansprechstrom, m; Ansprechstromstärke, f rus. ток срабатывания, m pranc. courant de déclenchement, m; courant minimum de …   Fizikos terminų žodynas

  • operative current — suveikimo srovė statusas T sritis fizika atitikmenys: angl. minimum working current; operative current; tripping current vok. Ansprechstrom, m; Ansprechstromstärke, f rus. ток срабатывания, m pranc. courant de déclenchement, m; courant minimum de …   Fizikos terminų žodynas

  • Residual-current device — A two pole residual current device A Residual Current Device is a generic term covering both RCCBs and RCBOs. A Residual Current Circuit Breaker (RCCB) is an electrical wiring device that disconnects a circuit whenever it detects that the… …   Wikipedia

  • Legend tripping — Legend tripping, also known as ostension, [Ellis, Bill. Legend Trips and Satanism: Adolescents Ostensive Traditions as Cult Activity. In The Satanism Scare , ed. James T. Richardson, Joel Best, and David G. Bromley, 279 95. NY: Aldme DeGreyter]… …   Wikipedia

  • Circuit breaker — For other uses, see Circuit breaker (disambiguation). An air circuit breaker for low voltage (less than 1000 volts) power distribution switchgear …   Wikipedia

  • Test and tagging — is a generic name given to the process of visually inspecting and electrically testing in service electrical equipment for personal use and/or safety. Colloquially, it is also referred to as; tagging, test tag, test and tag, electrical tagging,… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»