-
21 transformer oil
-
22 transformer oil
-
23 transformer oil
-
24 transformer oil
மின்மாற்றி எண்ணெய் -
25 transformer oil
n трансформаторне мастило -
26 transformer oil
transformatör yagi -
27 transformer oil-cooler
penyejuk minyak transformator -
28 fresh transformer oil pump
маслонасос свежего трансформаторного масла
(напр. газотурбинной электростанции)
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
Англо-русский словарь нормативно-технической терминологии > fresh transformer oil pump
-
29 service transformer oil pump
маслонасос эксплуатационного трансформаторного масла
(напр. газотурбинной электростанции)
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
Англо-русский словарь нормативно-технической терминологии > service transformer oil pump
-
30 protocol of transformer oil testing
Универсальный англо-русский словарь > protocol of transformer oil testing
-
31 passivated transformer oil
• дълготрайно трансформаторно маслоEnglish-Bulgarian polytechnical dictionary > passivated transformer oil
-
32 oil
- oil
- n1. масло; смазочный материал, смазка
2. нефть; нефтепродукт
- banana oil
- bodied linseed oil
- boiled linseed oil
- bone oil
- coal tar oil
- creosote oil
- crude oil
- flux oil
- formwork oil
- form oil
- fuel oil
- heat transfer oil
- linseed oil
- mineral oil
- mold oil
- paint oil
- raw linseed oil
- residual oil
- road oil
- rosin oil
- silicone oil
- tar oil
- thick oil
- thin oil
- transformer oil
- tung oil
- used oil
- working oil
Англо-русский строительный словарь. — М.: Русский Язык. С.Н.Корчемкина, С.К.Кашкина, С.В.Курбатова. 1995.
* * * -
33 transformer
3) пищ. котёл для получения инвертированного сиропа•-
adapter transformer
-
adjustable transformer
-
air transformer
-
air-blast transformer
-
air-cooled transformer
-
air-core transformer
-
air-natural transformer
-
amorphous-core transformer
- arc furnace transformer -
arc-welding transformer
-
audio-frequency transformer
-
autocompounded current transformer
-
autocompounded voltage transformer
-
autoconnected transformer
-
auxiliary transformer
-
balanced-to-unbalanced transformer
-
balance-to-unbalanced transformer
-
balanced-to-unbalance transformer
-
balance-to-unbalance transformer
-
balanced transformer
-
balancing transformer
-
ballast transformer
-
banked distribution transformers
-
bar-type transformer
-
bell transformer
-
booster transformer
-
bridge transformer
-
busbar current transformer
-
capacitive voltage transformer
-
cascade transformer
-
cast resin transformer
-
center-tapped transformer
-
closed core transformer
-
code transformer
-
combined voltage and current transformer
-
compensated current transformer
-
compensated voltage transformer
-
compound-filled instrument transformer
-
constant-current transformer
-
constant-potential transformer
-
control circuit transformer
-
control transformer
-
converter transformer
-
coreless transformer
-
core-type transformer
-
coupling transformer
-
current transformer
-
decoupling transformer
-
differential transformer
-
diode-split line-output transformer
-
direct-current transformer
-
distribution transformer
-
double-stub transformer
-
double-tuned transformer
-
double-winding transformer
-
driving transformer
-
dry-type transformer
-
dry transformer
-
dry-type forced-air-cooled transformer
-
dry-type self-cooled transformer
-
E transformer
-
earthed transformer
-
earthing transformer
-
effective grounded transformer
-
EHV power transformer
-
excitation transformer
-
extra-high-voltage power transformer
-
feed transformer
-
feeder transformer
-
feeding transformer
-
filter transformer
-
five-legged transformer
-
flash transformer
-
flyback transformer
-
forced-air-cooled transformer
-
forced-oil transformer
-
frame-output transformer
-
furnace transformer
-
gas-filled transformer
-
gas-insulated transformer
-
general transformer
-
general-purpose transformer
-
grounded transformer
-
grounding transformer
-
high-potential transformer
-
high-power transformer
-
high-voltage transformer
-
horizontal-output transformer
-
house transformer
-
hydropneumatic transformer
-
ideal transformer
-
image-output transformer
-
impedance transformer
-
impedance-matching transformer
-
impulse current transformer
-
indoor transformer
-
induction voltage transformer
-
injector transformer
-
input transformer
-
instrument transformer
-
insulated-core transformer
-
insulating transformer
-
integral current transformer
-
interphase transformer
-
intervening current transformer
-
iron-clad transformer
-
iron-core transformer
-
isolating transformer
-
lightning-proof transformer
-
line regulating transformer
-
line transformer
-
linear hydraulic transformer
-
line-output transformer
-
liquid-filled transformer
-
loading transformer
-
low-power transformer
-
low-voltage transformer
-
mains transformer
-
manhole transformer
-
matching transformer
-
measuring transformer
-
micromodular transformer
-
mode transformer
-
molded transformer
-
multiratio current transformer
-
multiratio voltage transformer
-
multiwinding transformer
-
natural-draft transformer
-
network transformer
-
nonmagnetic current transformer
-
nonresonating transformer
-
oil-cooled transformer
-
oil transformer
-
oil-filled instrument transformer
-
oil-immersed forced-air-cooled transformer
-
oil-immersed forced-oil-cooled transformer
-
oil-immersed self-cooled transformer
-
oil-immersed transformer
-
oil-immersed water-cooled transformer
-
one-coil transformer
-
one-to-one transformer
-
on-load tap-changing transformer
-
open-core transformer
-
outdoor transformer
-
output transformer
-
pad-mounted transformer
-
peaking transformer
-
peak transformer
-
phase-shifting transformer
-
pole-type transformer
-
polyphase transformer
-
potential transformer
-
power transformer
-
protection current transformer
-
protection voltage transformer
-
protective transformer
-
pulse transformer
-
pulse-forming transformer
-
radio-frequency transformer
-
reactance-earthed transformer
-
reactor transformer
-
rectifier transformer
-
reducing transformer
-
regulating transformer
-
relay transformer
-
resistance-earthed transformer
-
resonance transformer
-
rotary hydraulic transformer
-
rotary transformer
-
rotatabletransformer
-
saturable current transformer
-
saturable transformer
-
saturating current transformer
-
sealed transformer
-
self-cooled transformer
-
self-protected transformer
-
series regulating transformer
-
series transformer
-
SF6-filled transformer
-
shell-core transformer
-
shell-form
-
shell-type transformer
-
shunt transformer
-
signal transformer
-
single-phase transformer
-
single-turn current transformer
-
small-power transformer
-
solidly earthed transformer
-
spare transformer
-
standard current transformer
-
standard instrument transformer
-
standard potential transformer
-
standby transformer
-
starting transformer
-
step-down transformer
-
step-up transformer
-
subdivided transformer
-
submersible transformer
-
substation transformer
-
supply transformer
-
tank transformer
-
tap-changing transformer
-
tap-changing-under-load transformer
-
tapped transformer
-
teaser transformer
-
testing transformer
-
test transformer
-
thermal transformer
-
three-circuit transformer
-
three-legged transformer
-
three-leg transformer
-
three-phase transformer
-
three-winding transformer
-
through-type current transformer
-
tool transformer
-
toroidal-coretransformer
-
toroidaltransformer
-
track-circuit transformer
-
track transformer
-
traction-feeding transformer
-
triple-wound transformer
-
tuned transformer
-
two-winding transformer
-
unbalanced-to-balanced transformer
-
unbalance-to-balanced transformer
-
unbalanced-to-balance transformer
-
unbalance-to-balance transformer
-
unearthed transformer
-
variable-ratio transformer
-
vertical-output transformer
-
voltage measuring transformer
-
voltage transformer
-
water-cooled transformer
-
welding transformer
-
window-type current transformer
-
zero-phase sequence current transformer -
34 oil-cooled transformer
масляный трансформатор
Трансформатор с жидким диэлектриком, в котором основной изолирующей средой и теплоносителем служит трансформаторное масло
[ ГОСТ 16110-82]
масляный трансформатор
Трансформатор, магнитная система и обмотки которого погружены в масло
(МЭС 421-01-14)
[ ГОСТ 30830-2002]EN
oil-immersed type transformer
a transformer of which the magnetic circuit and windings are immersed in oi
[IEV number 421-01-14]FR
transformateur immergé dans l'huile
transformateur dont le circuit magnétique et les enroulements sont immergés dans l'huile
[IEV number 421-01-14]Oil transformers
The magnetic circuit and the windings are immersed in a liquid dielectric that provides insulation and evacuates the heat losses of the transformer.
This liquid expands according to the load and the ambient temperature. PCBs and TCBs are now prohibited and mineral oil is generally used. It is flammable and requires protective measures against the risks of fire, explosion and pollution.
The most commonly used protective measures are the DGPT or the DGPT2: Gas, Pressure and Temperature sensor with 1 or 2 sensing levels on the temperature. This system cuts off the LV load (1st level) then the HV supply (2nd level) when there is a fault inside the transformer. A holding tank is used to recover all the liquid dielectric.
Of the four types of immersed transformer: free breathing transformers, gas cushion transformers, transformers with expansion tank and transformers with integral filling, only the latter are currently installed.
[Legrand]Масляные трансформаторы
Магнитная система и обмотки трансформатора погружены в жидкий диэлектрик, служащий изоляцией и теплоносителем.
Жидкий диэлектрик изменяет свой объем в соответствии с нагрузкой трансформатора и температурой окружающей среды. Поскольку в настоящее время применение полихлорированных дифенилов и тетрахлорбифенилов запрещено, то в основном используют минеральное масло. Оно огнеопасно, поэтому необходимо принимать меры против возникновения пожара, взрыва и загрязнения окружающей среды.
Как правило, применяются системы DGPT (одноуровневые системы, использующие датчики газа, давления и температуры) или DGPT2 – двухуровневые системы. В случае возникновения аномального состояния трансформатора данные системы отключают нагрузку цепей низшего напряжения (первый уровень защиты), а затем питание обмотки высшего напряжения (второй уровень защиты). Активная часть трансформатора находится в баке и полностью покрыта жидким диэлектриком.
Существует четыре типа масляных трансформаторов: трансформаторы с системой свободного дыхания, трансформаторы с газовой подушкой между зеркалом масла и крышкой трансформатора, трансформаторы с расширительным баком и трансформаторы с гофрированным баком. В настоящее время применяют только трансформаторы последнего типа
[Интент]
[http://www.ramo-chelny.ru/konschasti.html]Масляный трансформатор:
- Шихтованный магнитопровод
- Обмотка низшего напряжения
- Обмотка высшего напряжения
- Трубчатый бак
- Термометр
- Переключатель регулировочных отводов обмотки высшего напряжения
- Ввод (проходной изолятор) обмотки низшего напряжения
- Ввод (проходной изолятор) обмотки высшего напряжения
- Расширительный бак
[http://transfcomplect.narod.ru/transformator.html]Тематики
Классификация
>>>EN
DE
FR
трансформатор с масляным охлаждением
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > oil-cooled transformer
-
35 transformer
1) трансформатор
2) трансформаторный
3) преобразователь
4) преобразовательный
– air-blast transformer
– audio-frequency transformer
– autocompounded transformer
– balanced transformer
– bell transformer
– booster transformer
– broad-band transformer
– bus-bar transformer
– bushing transformer
– bushing-type transformer
– capacitor transformer
– cascade transformer
– center-tap transformer
– centertap transformer
– coaxial transformer
– constant-current transformer
– core of a transformer
– core-type transformer
– coupling transformer
– current transformer
– distortion transformer
– doorknob transformer
– double-wound transformer
– dry-type transformer
– filament transformer
– filament-supply transformer
– forced-air-cooled transformer
– frequency transformer
– furnace transformer
– hedgehog transformer
– high-power transformer
– house transformer
– i f transformer
– input transformer
– instrument transformer
– interstage transformer
– intervening transformer
– iron-core transformer
– isolation transformer
– lightning-proof transformer
– line transformer
– loading transformer
– matching transformer
– mobile transformer
– molded transformer
– multioperator transformer
– multiple-tuned transformer
– multiwinding transformer
– narrow-band transformer
– oil-filled transformer
– oil-immersed transformer
– output transformer
– phantom transformer
– phase-shifting transformer
– pole-type transformer
– pot transformer
– power transformer
– protected transformer
– push-pull transformer
– r f transformer
– rotary transformer
– rotating transformer
– saturating transformer
– sealed transformer
– shell-type transformer
– single-phase transformer
– starting transformer
– step-down transformer
– step-up transformer
– sucking transformer
– summing transformer
– tapped transformer
– track transformer
– transformer coupling
– transformer oil
– transformer steel
– transformer substation
– transformer tank
– transformer vault
– tuned transformer
– variable transformer
– variable-ratio transformer
– voltage transformer
– waveguide transformer
– welding transformer
core of a shell transformer — сердечник трансформатора броневой
distribution power transformer — трансформатор силовой линейный
generalized impedance transformer — < radio> преобразователь сопротивления обобщенный
hydrodynamic torque transformer — гидродинамический трансформатор
station service transformer — <engin.> трансформатор собственных нужд
transformer steps up voltage — трансформатор повышает напряжение
variable current transformer — трансформатор переменного тока
-
36 oil transformer
масляный трансформатор
Трансформатор с жидким диэлектриком, в котором основной изолирующей средой и теплоносителем служит трансформаторное масло
[ ГОСТ 16110-82]
масляный трансформатор
Трансформатор, магнитная система и обмотки которого погружены в масло
(МЭС 421-01-14)
[ ГОСТ 30830-2002]EN
oil-immersed type transformer
a transformer of which the magnetic circuit and windings are immersed in oi
[IEV number 421-01-14]FR
transformateur immergé dans l'huile
transformateur dont le circuit magnétique et les enroulements sont immergés dans l'huile
[IEV number 421-01-14]Oil transformers
The magnetic circuit and the windings are immersed in a liquid dielectric that provides insulation and evacuates the heat losses of the transformer.
This liquid expands according to the load and the ambient temperature. PCBs and TCBs are now prohibited and mineral oil is generally used. It is flammable and requires protective measures against the risks of fire, explosion and pollution.
The most commonly used protective measures are the DGPT or the DGPT2: Gas, Pressure and Temperature sensor with 1 or 2 sensing levels on the temperature. This system cuts off the LV load (1st level) then the HV supply (2nd level) when there is a fault inside the transformer. A holding tank is used to recover all the liquid dielectric.
Of the four types of immersed transformer: free breathing transformers, gas cushion transformers, transformers with expansion tank and transformers with integral filling, only the latter are currently installed.
[Legrand]Масляные трансформаторы
Магнитная система и обмотки трансформатора погружены в жидкий диэлектрик, служащий изоляцией и теплоносителем.
Жидкий диэлектрик изменяет свой объем в соответствии с нагрузкой трансформатора и температурой окружающей среды. Поскольку в настоящее время применение полихлорированных дифенилов и тетрахлорбифенилов запрещено, то в основном используют минеральное масло. Оно огнеопасно, поэтому необходимо принимать меры против возникновения пожара, взрыва и загрязнения окружающей среды.
Как правило, применяются системы DGPT (одноуровневые системы, использующие датчики газа, давления и температуры) или DGPT2 – двухуровневые системы. В случае возникновения аномального состояния трансформатора данные системы отключают нагрузку цепей низшего напряжения (первый уровень защиты), а затем питание обмотки высшего напряжения (второй уровень защиты). Активная часть трансформатора находится в баке и полностью покрыта жидким диэлектриком.
Существует четыре типа масляных трансформаторов: трансформаторы с системой свободного дыхания, трансформаторы с газовой подушкой между зеркалом масла и крышкой трансформатора, трансформаторы с расширительным баком и трансформаторы с гофрированным баком. В настоящее время применяют только трансформаторы последнего типа
[Интент]
[http://www.ramo-chelny.ru/konschasti.html]Масляный трансформатор:
- Шихтованный магнитопровод
- Обмотка низшего напряжения
- Обмотка высшего напряжения
- Трубчатый бак
- Термометр
- Переключатель регулировочных отводов обмотки высшего напряжения
- Ввод (проходной изолятор) обмотки низшего напряжения
- Ввод (проходной изолятор) обмотки высшего напряжения
- Расширительный бак
[http://transfcomplect.narod.ru/transformator.html]Тематики
Классификация
>>>EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > oil transformer
-
37 oil-immersed type transformer
масляный трансформатор
Трансформатор с жидким диэлектриком, в котором основной изолирующей средой и теплоносителем служит трансформаторное масло
[ ГОСТ 16110-82]
масляный трансформатор
Трансформатор, магнитная система и обмотки которого погружены в масло
(МЭС 421-01-14)
[ ГОСТ 30830-2002]EN
oil-immersed type transformer
a transformer of which the magnetic circuit and windings are immersed in oi
[IEV number 421-01-14]FR
transformateur immergé dans l'huile
transformateur dont le circuit magnétique et les enroulements sont immergés dans l'huile
[IEV number 421-01-14]Oil transformers
The magnetic circuit and the windings are immersed in a liquid dielectric that provides insulation and evacuates the heat losses of the transformer.
This liquid expands according to the load and the ambient temperature. PCBs and TCBs are now prohibited and mineral oil is generally used. It is flammable and requires protective measures against the risks of fire, explosion and pollution.
The most commonly used protective measures are the DGPT or the DGPT2: Gas, Pressure and Temperature sensor with 1 or 2 sensing levels on the temperature. This system cuts off the LV load (1st level) then the HV supply (2nd level) when there is a fault inside the transformer. A holding tank is used to recover all the liquid dielectric.
Of the four types of immersed transformer: free breathing transformers, gas cushion transformers, transformers with expansion tank and transformers with integral filling, only the latter are currently installed.
[Legrand]Масляные трансформаторы
Магнитная система и обмотки трансформатора погружены в жидкий диэлектрик, служащий изоляцией и теплоносителем.
Жидкий диэлектрик изменяет свой объем в соответствии с нагрузкой трансформатора и температурой окружающей среды. Поскольку в настоящее время применение полихлорированных дифенилов и тетрахлорбифенилов запрещено, то в основном используют минеральное масло. Оно огнеопасно, поэтому необходимо принимать меры против возникновения пожара, взрыва и загрязнения окружающей среды.
Как правило, применяются системы DGPT (одноуровневые системы, использующие датчики газа, давления и температуры) или DGPT2 – двухуровневые системы. В случае возникновения аномального состояния трансформатора данные системы отключают нагрузку цепей низшего напряжения (первый уровень защиты), а затем питание обмотки высшего напряжения (второй уровень защиты). Активная часть трансформатора находится в баке и полностью покрыта жидким диэлектриком.
Существует четыре типа масляных трансформаторов: трансформаторы с системой свободного дыхания, трансформаторы с газовой подушкой между зеркалом масла и крышкой трансформатора, трансформаторы с расширительным баком и трансформаторы с гофрированным баком. В настоящее время применяют только трансформаторы последнего типа
[Интент]
[http://www.ramo-chelny.ru/konschasti.html]Масляный трансформатор:
- Шихтованный магнитопровод
- Обмотка низшего напряжения
- Обмотка высшего напряжения
- Трубчатый бак
- Термометр
- Переключатель регулировочных отводов обмотки высшего напряжения
- Ввод (проходной изолятор) обмотки низшего напряжения
- Ввод (проходной изолятор) обмотки высшего напряжения
- Расширительный бак
[http://transfcomplect.narod.ru/transformator.html]Тематики
Классификация
>>>EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > oil-immersed type transformer
-
38 transformer
-
39 oil
-
40 oil
1) масло; жидкая смазка; нефть2) смазывать•- additive engine oil - additive-type oil - alloyed oil - all-purpose oil - amber oil - anthracene oil - asphalt base oil - bleached oil - blown oil - bodied oil - boiled oil - burning oil - canned oil - cold oil - conventional oil - diesel oil - engine oil - fluorinated oil - flux oil - fuel oil - graphite oil - grease oil - heavy oil - hydraulic oil - injection of oil - lamp oil - leak of oil - level of oil - linseed oil - long oil - lubricating oil - mineral oil - motor oil - non-freezable oil - paraffine oil - polymerized oil - recirculated motor oil - road oil - solar oil - spindle oil - stability of oil - sump oil - tar oil - transformer oil - transmission oil for high pressures - trapped oil - tubular oil gauge - used oil - waste oil - winter oil* * *1. масло; смазочный материал, смазка2. нефть; нефтепродукт- banana oil
- bodied linseed oil
- boiled linseed oil
- bone oil
- coal tar oil
- creosote oil
- crude oil
- flux oil
- formwork oil
- form oil
- fuel oil
- heat transfer oil
- linseed oil
- mineral oil
- mold oil
- paint oil
- raw linseed oil
- residual oil
- road oil
- rosin oil
- silicone oil
- tar oil
- thick oil
- thin oil
- transformer oil
- tung oil
- used oil
- working oil
См. также в других словарях:
Transformer oil — is usually a highly refined mineral oil that is stable at high temperatures and has excellent electrical insulating properties. It is used in oil filled transformers, some types of high voltage capacitors, fluorescent lamp ballasts, and some… … Wikipedia
transformer oil — transformatorinė alyva statusas T sritis chemija apibrėžtis Elektroizoliacinė alyva, naudojama transformatoriuose. atitikmenys: angl. switch oil; transformer oil rus. трансформаторное масло … Chemijos terminų aiškinamasis žodynas
transformer oil — noun : an insulating oil (as a refined petroleum distillate) used especially in transformers … Useful english dictionary
Transformer — This article is about the electrical device. For the toy line franchise, see Transformers. For other uses, see Transformer (disambiguation). Pole mounted distribution transformer with center tapped secondary winding. This type of transformer is… … Wikipedia
Transformer types — Circuit symbols Transformer with two windings and iron core. Step down or step up transformer. The symbol shows which winding has more turns, but not usually the … Wikipedia
Oil Campaign chronology of World War II — Main articles: Oil Campaign of World War II and Oil Campaign targets of World War II The Oil Campaign chronology of World War II lists bombing missions and related events regarding the petroleum/oil/lubrication (POL) facilities that supplied Nazi … Wikipedia
oil transformer — alyvinis transformatorius statusas T sritis fizika atitikmenys: angl. oil transformer; tank transformer vok. ölgefüllter Transformator, m; ölgekühlter Transformator, m; Öltransformator, m rus. масляный трансформатор, m pranc. transformateur à… … Fizikos terminų žodynas
Oil burner — This article is about the heating device. For a meaning related to engines, see Oil burner (engine). An oil burner for domestic central heating An oil burner is a heating device which burns fuel oil. The oil is atomized in to a fine spray usually … Wikipedia
oil and water extractor — See air transformer … Dictionary of automotive terms
Tap (transformer) — This article is about tappings in transformers. For other uses, see Tap. A transformer tap is a connection point along a transformer winding that allows a certain number of turns to be selected. This means, a transformer with a variable turns… … Wikipedia
Coconut oil — Traditional way of making coconut oil using a bullock powered mill in Seychelles Coconut oil is an edible oil extracted from the kernel or meat of matured coconut harvested from the coconut palm (Cocos nucifera). Throughout the tropical world, it … Wikipedia