Перевод: с немецкого на русский

с русского на немецкий

the+allowable

  • 1 Dauerstrombelastbarkeit, f

    1. длительный допустимый ток

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Немецко-русский словарь нормативно-технической терминологии > Dauerstrombelastbarkeit, f

  • 2 Strombelastbarkeit, f

    1. длительный допустимый ток

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Немецко-русский словарь нормативно-технической терминологии > Strombelastbarkeit, f

  • 3 Umgebungstemperatur, f

    1. температура окружающей среды

     

    температура окружающей среды
    Средняя температура воздуха или другой среды около оборудования.
    Примечание - В процессе измерения температуры окружающей среды измерительный прибор (зонд) должен быть экранирован от сквозняков и нагрева излучением.
    [ ГОСТ Р МЭК 60050-826-2009]

    температура окружающей среды
    Температура воздуха или другой среды в непосредственной близости от оборудования или компонента.
    [ ГОСТ Р МЭК 60050-426-2006]

    температура окружающей среды
    Предполагают, что под температурой окружающей среды понимают воздействующие факторы со стороны всего другого оборудования, установленного в том же помещении.
    Температура окружающей среды, которую следует учитывать применительно к оборудованию, - это температура в том месте, где оно должно быть установлено, с учетом влияния другого оборудования и источников тепла в том же месте в процессе работы без учета тепла от устанавливаемого оборудования
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    температура окружающей среды
    Температура воздуха или среды в том месте, где должно быть использовано оборудование.
    [ ГОСТ Р МЭК 60204-1-2007]

    EN

    ambient temperature
    average temperature of air or another medium in the vicinity of the equipment
    NOTE – During the measurement of the ambient temperature the measuring instrument/probe should be shielded from draughts and radiant heating.
    [IEV number 826-10-03]

    ambient temperature

    temperature of the air or other medium where the equipment is to be used
    [IEC 60204-1-2006]

    FR

    température ambiante, f
    température moyenne de l'air ou du milieu au voisinage du matériel
    NOTE – Pendant la mesure de la température ambiante il est recommandé que l'instrument/la sonde de mesure soit protégée des courants d'air et de la chaleur rayonnée.
    [IEV number 826-10-03]

    Параллельные тексты EN-RU

    The temperate of each module of a Molded Case Circuit Breaker is the sum of temperature increase by conduction and ambient temperature and if the ambient temperature exceeds 40°C the passing current needs to be reduced so that the temperature of such element as internal insulator of MCCB exceed the maximum allowable temperature.
    [LS Industrial Systems]

    Температура частей автоматического выключателя в литом корпусе равна температуре окружающей среды плюс температура, определяемая количеством теплоты, выделяемой при протекании электрического тока. Если автоматический выключатель эксплуатируется при температуре окружающей среды, превышающей 40 °C, то следует учитывать, что номинальный ток такого выключателя будет немного меньше. Учет этого обстоятельства позволит избежать недопустимого нагрева частей автоматического выключателя, выполненных из изоляционного материала.
    [Перевод Интент]

    Тематики

    EN

    DE

    • Umgebungstemperatur, f

    FR

    • température ambiante, f

    Немецко-русский словарь нормативно-технической терминологии > Umgebungstemperatur, f

См. также в других словарях:

  • allowable marketing cost — The amount that can be spent on marketing while preserving the required profit margin. It is often calculated by deducting the cost of goods, the cost of fulfilment, and the desired profit from the total expected sales revenue. For example, if a… …   Big dictionary of business and management

  • allowable — al‧low‧a‧ble [əˈlaʊəbl] adjective 1. acceptable according to the rules: • The government has cut by 35% this year s allowable catch of fish. 2. ACCOUNTING an allowable amount, cost, or expense does not need to be counted as part of income or… …   Financial and business terms

  • allowable catch — the catch allowed by a management authority to be taken from a stock of a species or group of species, by a fishery during a specified time period. Often defined as the total allowable catch (TAC). Often allocated explicitly amongst those having… …   Dictionary of ichthyology

  • The Ramsay Principle — is the shorthand name given to the decision of the House of Lords in two important cases in the field of UK tax, reported in 1982: * Ramsay v. IRC, the full name of which is W. T. Ramsay Ltd. v. Inland Revenue Commissioners, Eilbeck (Inspector of …   Wikipedia

  • The Art of Seeing — is a 1942 book by Aldous Huxley, which contains an explanation and discussion of the Bates Method for better eyesight.Huxley’s own sightIn the preface to the book, Huxley describes how, at the age of sixteen, he had a violent attack of keratitis… …   Wikipedia

  • The Doe Fund — is a non profit organization that provides job training and work opportunities, housing assistance, advocacy and support for homeless and unemployed people in New York City. The Doe Fund s mission is to help homeless individuals obtain housing… …   Wikipedia

  • allowable stacking weight — The amount of weight that can be stacked on corner posts of a container when subjected to 1.8 times the force of gravity …   Military dictionary

  • allowable cabin load — The maximum payload that can be carried on an individual sortie. Also called ACL …   Military dictionary

  • allowable load — The total load that an aircraft can transport over a given distance, taking into account weight and volume. See also airlift capability; airlift requirement; load; payload …   Military dictionary

  • allowable — al|low|a|ble [əˈlauəbəl] adj 1.) acceptable according to the rules = ↑permissible ▪ The maximum allowable dosage is two tablets a day. 2.) allowable costs are costs that you do not pay tax on ▪ allowable deductions such as alimony and business… …   Dictionary of contemporary English

  • allowable — adjective 1 acceptable according to the rules: the maximum allowable dosage 2 allowable costs are costs that you do not pay tax on: allowable deductions such as alimony and business expenses …   Longman dictionary of contemporary English

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»