-
1 temperature effects
Военный термин: воздействие на температуру (т.е. влияние ядерных взрывов и образующегося аэрозоля на температурный режим в данном регионе) -
2 effects of the electric arc inside switchgear and controlgear assemblу
- действие электрической дуги, возникающей внутри НКУ распределения и управления
действие электрической дуги, возникающей внутри НКУ распределения и управления
-
[Интент]Параллельные тексты EN-RU
Effects of the electric arc inside switchgear and controlgear assemblies
In the proximity of the main boards, i.e. in the proximity of big electrical machines, such as transformers or generators, the short-circuit power is high and consequently also the energy associated with the electrical arc due to a fault is high.
Without going into complex mathematical descriptions of this phenomenon, the first instants of arc formation inside a cubicle can be schematized in 4 phases:
1. compression phase: in this phase the volume of the air where the arc develops is overheated owing to the continuous release of energy; due to convection and radiation the remaining volume of air inside the cubicle warms up; initially there are temperature and pressure values different from one zone to another;
2. expansion phase: from the first instants of internal pressure increase a hole is formed through which the overheated air begins to go out. In this phase the pressure reaches its maximum value and starts to decrease owing to the release of hot air;
3. emission phase: in this phase, due to the continuous contribution of energy by the arc, nearly all the air is forced out under a soft and almost constant overpressure;
4. thermal phase: after the expulsion of the air, the temperature inside the switchgear reaches almost that of the electrical arc, thus beginning this final phase which lasts till the arc is quenched, when all the metals and the insulating materials coming into contact undergo erosion with production of gases, fumes and molten material particles.
Should the electrical arc occur in open configurations, some of the described phases could not be present or could have less effect; however, there shall be a pressure wave and a rise in the temperature of the zones surrounding the arc.
Being in the proximity of an electrical arc is quite dangerous; here are some data to understand how dangerous it is:
• pressure: at a distance of 60 cm from an electrical arc associated with a 20 kA arcing fault a person can be subject to a force of 225 kg; moreover, the sudden pressure wave may cause permanent injuries to the eardrum;
• arc temperatures: about 7000-8000 °C;
• sound: electrical arc sound levels can reach 160 db, a shotgun blast only 130 db.
[ABB]Действие электрической дуги, возникающей внутри НКУ распределения и управления
Короткое замыкание вблизи больших силовых устройств, таких как трансформаторы или генераторы имеет очень большую мощность. Поэтому энергия электрической дуги, возникшей в результате короткого замыкания, очень большая.
Не вдаваясь в сложное математическое описание данного явления, можно сказать, что первые мгновения формирования дуги внутри шкафа можно упрощенно разделить на четыре этапа:
1. Этап сжатия: на этом этапе объем воздуха, в котором происходит зарождение дуги перегревается вследствие непрерывного высвобождения энергии. За счет конвекции и излучения оставшийся объем воздуха внутри шкафа нагревается. На этом начальном этапе значения температуры и давления воздуха в разных зонах НКУ разные.
2. Этап расширения: с первых мгновений внутреннее давление создает канал, через который начинается движение перегретого воздуха. На этом этапе давление достигает своего максимального значения, после чего начинает уменьшаться вследствие выхода горячего воздуха.
3. Этап эмиссии: на этом этапе вследствие непрерывного пополнения энергией дуги почти весь воздух выталкивается под действием мягкого и почти постоянного избыточного давления.
4. Термический этап: после выхлопа воздуха температура внутри НКУ почти достигает температуры электрической дуги. Так начинается заключительный этап, который длится до тех пор, пока дуга не погаснет. При этом все металлические и изоляционные материалы, вступившие в контакт с дугой, оказываются подвергнутыми эрозии с выделением газов, дыма и частиц расплавленного материала.
Если электрическая дуга возникнет в открытом НКУ, то некоторые из описанных этапов могут не присутствовать или могут иметь меньшее воздействие. Тем не менее будет иметь место воздушная волна и подъем температуры вблизи дуги.
Находиться вблизи электрической дуги довольно опасно. Ниже приведены некоторые сведения, помогающие осознать эту опасность:
• давление: На расстоянии 60 см от электрической дуги, вызванной током короткого замыкания 20 кА, человек может подвергнуться воздействию силы 225 кг. Более того, резкая волна давления может нанести тяжелую травму барабанным перепонкам;
• температура дуги: около 7000-8000 °C;
• шумовое воздействие: Уровень шумового воздействия электрической дуги может достигнуть 160 дБ (выстрел из дробовика – 130 дБ).
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
EN
Англо-русский словарь нормативно-технической терминологии > effects of the electric arc inside switchgear and controlgear assemblу
-
3 effects of the electrical arc on human beings
воздействие электрической дуги на человека
-
[Интент]Параллельные тексты EN-RU
Effects of the electrical arc on human beings
From the above, it is evident that the electrical arc represents a hazard source for people and goods.
The hazards to which a person is exposed due to the release of energy generated by an arc event are:
• burns;
• injuries due to ejection of materials;
• damages to hearing;
• inhalation of toxic gases.
Burns
The high temperature levels of the gases produced by the electrical arc and the expulsion of incandescent metal particles may cause more or less severe burns to people.
Flames can cause all degrees of burn up to carbonization: the red-hot solid bodies, such as the metal fragments of the assembly involved, cause third degree burns, superheated steam causes burns analogous to those by hot liquids whereas radiant heat generally causes less severe burns.
Injuries due to ejection of materials
The ejection of metal particles or other loose items caused by the electrical arc can result in severe injuries to the weakest parts of the human body as, for example, the eyes.
The materials expelled owing to the explosion produced by the arc may penetrate the cornea and hurt it.
The extent of the lesions depends on the characteristics and on the kinetic energy of these objects.
Moreover, the ocular region can sustain injuries to the mucosa because of the gases released by the arc and the emission of ultraviolet and infrared rays can injure the cornea and the retina depending on the radiation wavelengths.
Hearing
As already mentioned, the electrical arc is a real explosion, whose sound may cause permanent injuries to hearing.
Inhalation of toxic gases
The fumes produced by burnt insulating materials and by molten or vaporized metals can be toxic.
The fumes are caused by incomplete burning and are formed by carbon particles and by other solid substances suspended in the air.
[ABB]Воздействие электрической дуги на человека
Из сказанного выше совершенно очевидно, что электрическая дуга является источником опасности для людей и имущества.
При высвобождении энергии электрической дуги человек может подвергнуться следующим опасностям:
• получение ожогов;
• повреждения от выброса продуктов горения дуги;
• нарушение слуха;
• вдыхание ядовитых газов.
Ожоги
Высокая температура газов, образующихся при горении электрической дуги, и выброс раскаленных частиц металла могут явиться причиной достаточно тяжелых ожогов.
Можно получить любую степень ожогов, вплоть до обугливания. Раскаленные до красна твердые частицы, такие как металлические частицы НКУ, вызывают ожоги третьей степени. Перегретый пар вызывает ожоги, аналогичные ожогам от горячих жидкостей. Лучистая энергия вызывает менее тяжелые ожоги.
Повреждения от выброса продуктов горения дуги
Выброс металлических или иных частиц, происходящий при горении электрической дуги, может привести к серьезным телесным повреждениям, особенно при попадании в глаза.
Частицы, выбрасываемые при горении дуги, могут проникнуть в роговую оболочку глаза и повредить ее.
Степень поражения зависит от характеристик и кинетической энергии выбрасываемых частиц.
Кроме того, газы, выделяющиеся в процессе горения дуги, могут повредить слизистую оболочку глаз, а ультрафиолетовое и инфракрасное излучение – роговую оболочку и сетчатку в зависимости от длины волны воздействующего излучения.
Орган слуха
Как уже упоминалось, электрическая дуга представляет собой реальный взрыв, звук которого может нанести тяжелую травму органу слуха.
Вдыхание ядовитых газов
Продукты горения изоляционных материалов и пары металлов могут быть ядовитыми.
Дым, образующийся при неполном сгорании и содержащий частицы углерода и других веществ, попадает в окружающий воздух.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
EN
Англо-русский словарь нормативно-технической терминологии > effects of the electrical arc on human beings
-
4 effects of the changed temperature
Макаров: воздействие изменившейся температурыУниверсальный англо-русский словарь > effects of the changed temperature
-
5 property of snow to change its temperature at a given point under the effects of the changed temperature at the next point
Универсальный англо-русский словарь > property of snow to change its temperature at a given point under the effects of the changed temperature at the next point
-
6 differential effects line for air temperature
Универсальный англо-русский словарь > differential effects line for air temperature
-
7 effect
1) эффект; явление2) влияние, действие, воздействие3) результат, следствие4) мн. ч.; юр. имущество, собственность5) воздействовать; производить; осуществлять; исполнять•- effect of end conditions - effect of loading - effect of restraint - admixture effect - adsorption effect - adverse effect - biological effect - bursting effect - chimney effect - cleaning effect - corrosive effect - damage effect - destructive effect - detrimental effect - dissipative effect - distributive effect - edge effect - end effect - heat effect - ill effect - illuminating effect - immediate effect - impact effect - indirect effect - luminous effect - notch effect - out-of-balance effect - overturning effect on the dam - poisonous effect - sagging effect - scale effect - screening effect - shaded effects - shattering effect - shielding effect - slagging effect - spading effect - stiffening effect - stiffening effect of cladding - strength-reduction effect - stress-rising effect - suction effect - time effect - toxic effect - unfavourable effect - useful effect* * *действие, воздействие, эффект; влияние; следствие, результат; производительность- effects of age
- effects of earthquake
- effect of end conditions
- effect of moisture changes
- effect of restraint
- effect of support settlement
- effect of temperature
- effect of temperature difference
- adverse effect
- adverse health effects
- backwater effect
- Bauschinger effect
- borehole effect
- boundary effect
- ceiling effect
- chimney effect
- climate effect
- Coanda effect
- combined effect
- combined effects of settlement and creep
- dehumidifying effect
- detrimental effect
- earthquake effect
- edge effect
- elevator effect
- environment effects on construction productivity
- fly ash effect on concrete properties
- frost effect
- greenhouse effect
- humidifying effect
- inertia effects
- insulating effect
- long-term effects
- microsilica effect on concrete properties
- mottle effect
- negative effect
- notch effect
- principle effect of the admixture
- radiation effects
- scale effect
- seasonal effect
- sensible cooling effect
- silo effect
- stack effect
- stiffening effect
- stiffening effects of floors
- sun effect
- thermal effect of building materials
- thermal effect of ceiling height
- thermal effect of roof types
- thermal effect of windows
- time-dependent effect
- total cooling effect
- weather effects on use of bond breaker
- wobble effect
- zero curtain effect -
8 effect
- effect
- nдействие, воздействие, эффект; влияние; следствие, результат; производительность
- effects of age
- effects of earthquake
- effect of end conditions
- effect of moisture changes
- effect of restraint
- effect of support settlement
- effect of temperature
- effect of temperature difference
- adverse effect
- adverse health effects
- backwater effect
- Bauschinger effect
- borehole effect
- boundary effect
- ceiling effect
- chimney effect
- climate effect
- Coanda effect
- combined effect
- combined effects of settlement and creep
- dehumidifying effect
- detrimental effect
- earthquake effect
- edge effect
- elevator effect
- environment effects on construction productivity
- fly ash effect on concrete properties
- frost effect
- greenhouse effect
- humidifying effect
- inertia effects
- insulating effect
- long-term effects
- microsilica effect on concrete properties
- mottle effect
- negative effect
- notch effect
- principle effect of the admixture
- radiation effects
- scale effect
- seasonal effect
- sensible cooling effect
- silo effect
- stack effect
- stiffening effect
- stiffening effects of floors
- sun effect
- thermal effect of building materials
- thermal effect of ceiling height
- thermal effect of roof types
- thermal effect of windows
- time-dependent effect
- total cooling effect
- weather effects on use of bond breaker
- wobble effect
- zero curtain effect
Англо-русский строительный словарь. — М.: Русский Язык. С.Н.Корчемкина, С.К.Кашкина, С.В.Курбатова. 1995.
-
9 effect
1) эффект; явление2) влияние; (воз)действие || воздействовать3) результат, следствие4) производить; совершать; исполнять; осуществлять•in ground effect — в зоне влияния земли ( о полёте); с учётом влияния земли;effect of force — действие (влияние) силыeffect of loading — следствие приложения нагрузки-
abrasing effect
-
accordion effect
-
acoustoelectric effect
-
acoustoresistive effect
-
activation effect
-
adjacency effects
-
adsorption effect
-
Albert effect
-
anode effect
-
anticrease effect
-
arch effect
-
Auger effect
-
autocatalytic effect
-
avalanche effect
-
Barkhausen effect
-
Becquerel effect
-
biological effect
-
blackout effect
-
blast effect
-
blockage effect
-
border effect
-
boundary effect
-
Bragg effect
-
braking effect
-
branching effect
-
bulk effect
-
Callier effect
-
capillary effect
-
capture effect
-
cartooning effect
-
cartoon effect
-
caster effect
-
catalytic effect
-
cavity resonance effect
-
changing quality effect
-
channel effect
-
channeling effect
-
chilling effect
-
chimney effect
-
chugging effect
-
Clayden effect
-
climatic effect
-
Coanda effect
-
comet effect
-
compressibility effect
-
Compton effect
-
constant thrust effect
-
contrast effect
-
controlled cooling effect
-
cooling effect
-
corona effect
-
corrosive effect
-
coupling effect
-
crawling effect
-
crevice effect
-
crimping effect
-
cross effect
-
cross-magnetizing effect
-
crowding effect
-
cryoprotective effect
-
cushioning effect
-
damming effect
-
Debot effect
-
deleterious effect
-
Dellinger effect
-
Dember effect
-
de-skilling effect
-
destructive effect
-
detrimental effect
-
devastating effect
-
diffusion effect
-
digital production effect
-
digital special effect
-
digital video effect
-
directional effect
-
disordering effect
-
dispersion effect
-
dissipative effect
-
distance effect of damming
-
disturbing effect
-
Doppler effect
-
dynatron effect
-
echo effect
-
ecological effect
-
Ederhard's effect
-
Ederhard effect
-
edge effect
-
Edison effect
-
electrocaloric effect
-
electroosmotic effect
-
electrophonic effect
-
electrophoretic effect
-
electroviscous effect
-
emitter dip effect
-
end effect
-
environmental effect
-
Esaki effect
-
exposure effect
-
failure effect
-
Faraday effect
-
fatigue effect
-
feedback effect
-
Ferranti effect
-
ferroelectric effect
-
field effect
-
flicker effect
-
flow history effect
-
flue effect
-
force-frequency effect
-
fringe effect
-
gallery effect
-
galvanomagnetic effect
-
gap effect
-
gettering effect
-
glint effect
-
greenhouse effect
-
ground effect
-
Gunn effect
-
gyromagnetic effect
-
gyroscopic effect
-
Haas effect
-
Hall effect
-
halo effect
-
heat effect
-
Herschel effect
-
high-field effect
-
hothouse effect
-
hydration effect
-
hysteresis effect
-
image effect
-
incondensable effect
-
instability effect
-
interface effects
-
interference effect
-
interline-flicker effect
-
inverted barometer effect
-
ionic strength effect
-
ion strength effect
-
island effect
-
Johnson-Rahbek effect
-
Josephson effect
-
Joule effect
-
Joule-Thomson effect
-
Kelvin effect
-
Kerr effect
-
keystone effect
-
Kostinsky's effect
-
Kostinsky effect
-
lag effect
-
level quantizing effect
-
long-line effect
-
lubricating effect
-
magnetoelastic effect
-
magnetoelectric effect
-
magnetoresistive effect
-
magnetostrictive effect
-
magnetron effect
-
mass effect
-
microphonic effect
-
minimum-size effect
-
mirror effect
-
mixed alkali effect
-
moire effect
-
multiaccelerator effect
-
multipath effect
-
musical effects
-
net effect
-
nonnuclear effect
-
notch impact effect
-
nuclear effect
-
orange-peel effect
-
pairing effect
-
Peltier effect
-
photochemical effect
-
photochromic effect
-
photoconductive effect
-
photoelastic effect
-
photoelectric effect
-
photographic effect
-
photorefractive effect
-
photovoltaic effect
-
piezoelectric effect
-
piezomagnetic effect
-
piezoresistance effect
-
pile-up effect
-
pinch effect
-
pincushion effect
-
plastering effect
-
plastic effect
-
poisonous effect
-
polarization effect
-
pollution effect
-
posterization effect
-
postproduction effects
-
precedence effect
-
presence effect
-
printthrough effect
-
processing effect
-
promoting effect
-
propagation effect
-
protective effect
-
proximity effect
-
punch-through effect
-
radiation effect
-
ram effect
-
Raman effect
-
reciprocity effect
-
refrigerating effect
-
relief effect
-
remote effect
-
residual effect
-
rewet-conduction effect
-
rewet-precooling effect
-
Richardson effect
-
ringing effect
-
ripple effect
-
rocky-point effect
-
rod shadow effect
-
roll-over effect
-
Ross effect
-
rotary wipe effects
-
rotational effect
-
rubberlike effect
-
S effect
-
Sabattier effect
-
salting-in effect
-
salting-out effect
-
schlieren effect
-
Schottky effect
-
Schwarzschild effect
-
screening effect
-
Seebeck effect
-
selective effect
-
self-demagnetization effect
-
self-energizing effect
-
self-shielding effect
-
sensible cooling effect
-
shape memory effect
-
shattering effect
-
shot effect
-
shoulder effect
-
side effect
-
sink effect
-
skin effect
-
skin-core effect
-
skinning effect
-
slipstream effect
-
smearing effect
-
solvation effect
-
sound effects
-
space-charge effect
-
spacing effect
-
spatial defocusing effect
-
spill effect
-
spin wipe effects
-
split-screen effect
-
stack effect
-
Stark effect
-
stereo effect
-
stiffening effect
-
streaking effect
-
stream-line effect
-
stroboscopic effect
-
suppressing effect
-
surface effect
-
surging effect
-
swooping effect
-
synergistic effect
-
temperature effect
-
tensoresistive effect
-
thermal effect
-
thermal transpiration effect
-
thermoelectric effect
-
Thomson effect
-
threshold effect
-
time-edge effect
-
timeedge effect
-
transients effect
-
triboelectric effect
-
trick effects
-
tunneling effect
-
tunnel effect
-
vacancy wind effect
-
venetian blind effect
-
video mosaic effect
-
Villard's effect
-
Villard effect
-
Volta effect
-
volumetric refrigerating effect
-
wake effect
-
wall effect
-
wall-quenching effect
-
weather effect
-
wedging effect
-
white effect
-
Wigner effect
-
wipe screen effect -
10 arc-proof low voltage switchgear and controlgear assembly
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof low voltage switchgear and controlgear assembly
-
11 arc-proof switchboard
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof switchboard
-
12 arc-proof switchgear
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof switchgear
-
13 arc-resistant switchgear
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-resistant switchgear
-
14 internal arc-proof switchgear and controlgear assemblу
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > internal arc-proof switchgear and controlgear assemblу
-
15 effect
1. действие, эффект, влияние, результат, полезное действие2. производительность, работа; результат, следствие || выполнять; производить, осуществлять, действовать
* * *
влияние; действие; воздействие
* * *
действие, эффект, влияние; результат, следствие
* * *
влияние; действие; воздействие; эффект- effect of drilling mud variables on drilling rate
- effect of drilling string weight
- effect of strength reduction
- adjacent formation effect
- adsorption effect
- anisotropic effect
- areal sweep effect
- array effect
- bed thickness effect
- birefringence effect
- borehole effect
- bubble effect
- buoyancy effect
- buried-focus effect
- chemical effect
- critical effect
- cutting effect
- degrading effect
- destructive effect
- disruptive effect
- drilling mud effect
- drilling mud plastering effect
- electroseismic effect
- end effect in core
- explosion effect
- failure effects
- filtration effect
- ghosting effect
- hazard effect
- hole-blow effect
- hydrocarbon effect
- impact effect
- interference effect
- invasion effect
- lateral effect
- layering effect
- mechanical effect
- mud cake effect
- mud column effect
- near-surface layer effect
- pendulum effect
- plastering effect
- pollution effect
- porosity effect
- pressure effect
- ray-focusing effect
- ray-refraction effect
- reflectivity effect
- reverberation effect
- rise-time effect
- seismic effect
- seismic-amplification effect
- seismoelectrical effect
- seismological effect
- seismomagnetic effect
- seismotectonic effect
- shock effect
- short-circulating effect
- shoulder-bed effect
- skin effect
- spherical divergence effect
- suction effect
- surface pipe effect
- surge effect
- swabbing effect
- time lag effect
- topographic effect
- tuning effect
- vertical sweep effect
- waveguide effect
- wear-out effect
- weathering effect* * *• работа -
16 NET
1) Компьютерная техника: Null End Tag2) Медицина: norethisterone, neuroendocrine tumor (нейроэндокринная опухоль)3) Американизм: National Electrotechnical Training, Natural Environment Training4) Военный термин: network, new equipment training, nuclear effects test, nuclear emergency team5) Техника: Next European Tokamak6) Шутливое выражение: Nuts! Everything's Taken7) Религия: National Evangelization Teams, Neighborhood Evangelism Training, New Evangelism Technologies8) Юридический термин: Narcotics Eradication Team9) Грубое выражение: Nitwit Endless Trades10) Оптика: noise equivalent temperature11) Сокращение: National Educational Television, New England Telephone, Normal Environmental Temperature, not earlier than12) Театр: Non Equity Theater13) Университет: Nurse Entrance Test14) Физиология: National Emphysema Treatment, Neuro Emotional Technique16) Деловая лексика: No Earlier Than17) Образование: Never Ever Try18) Интернет: Major Network support centers19) Расширение файла: Network Configuration/ Information file20) Общественная организация: National Environmental Trust21) NYSE. North European Oil Realty Trust22) СМС: Not Entirely True -
17 Net
1) Компьютерная техника: Null End Tag2) Медицина: norethisterone, neuroendocrine tumor (нейроэндокринная опухоль)3) Американизм: National Electrotechnical Training, Natural Environment Training4) Военный термин: network, new equipment training, nuclear effects test, nuclear emergency team5) Техника: Next European Tokamak6) Шутливое выражение: Nuts! Everything's Taken7) Религия: National Evangelization Teams, Neighborhood Evangelism Training, New Evangelism Technologies8) Юридический термин: Narcotics Eradication Team9) Грубое выражение: Nitwit Endless Trades10) Оптика: noise equivalent temperature11) Сокращение: National Educational Television, New England Telephone, Normal Environmental Temperature, not earlier than12) Театр: Non Equity Theater13) Университет: Nurse Entrance Test14) Физиология: National Emphysema Treatment, Neuro Emotional Technique16) Деловая лексика: No Earlier Than17) Образование: Never Ever Try18) Интернет: Major Network support centers19) Расширение файла: Network Configuration/ Information file20) Общественная организация: National Environmental Trust21) NYSE. North European Oil Realty Trust22) СМС: Not Entirely True -
18 TE
1) Общая лексика: hum. сокр. Tissue Engineering2) Компьютерная техника: traffic efficiency3) Биология: transposable element4) Медицина: эхо-время, время появления эхо-сигнала (КТ), tissue equalization5) Спорт: Team Effort, Team Efforts, Tilt End, Tournament Edition6) Военный термин: Tactical Exploitation, Test Edition, Thermal Eagle, Third Eye, Tracking Error, Treachery Element, table of equipment, tactical element, tactical employment, tactical environment, tangent elevation, tank element, target elevation, target evaluation, task element, task evaluation, telecommunication engineering, terminal exchange, test and evaluation, test equipment, threat evaluation, topographical engineer, training equipment, training establishment, transporter-erector, ФЦО7) Техника: Terminal Exchanges, Trunk Equalizers, telemetric equipment, thermal efficiency, timing electronics, tractive effort, transducer efficiency, transferred electron, transversely excited8) Химия: Toxicity Equivalent9) Железнодорожный термин: Tacoma Eastern Railway Company10) Юридический термин: Temperament Edit, Trace Evidence11) Бухгалтерия: Total Expenditure, Total Expenses12) Автомобильный термин: thermal expansion13) Оптика: thermoelectric14) Политика: Tromelin Island15) Телекоммуникации: Terminal Equipment (ISDN)16) Сокращение: Tactical Evaluation, Technical Commission, Technical Evaluation, Teileinheit (Единица ширины. 1 TE = 5,08 мм), Telugu, Trailing Edge, Transitional Employees (USPS, 2008), tables of equipment, tax exempt, test and evaluate, testing, thermal element, totally enclosed, trade expenses, transverse electric, эквивалент токсичности, токсический эквивалент17) Университет: Technology And Engineering, Thoroughly Educated18) Физиология: Tamper Evident, Therapeutic exercises, Throat Erosion, Transposon Excision, Triggered Effects19) Электроника: Electron Temperature, Top Electrode, Total Efficiency20) Нефть: twin-engined, испытательное оборудование (testing equipment), оценка технических характеристик (technical evaluation)21) Связь: terminal equipment22) Биотехнология: Tissue Equivalent23) Транспорт: Tank Economy, Traffic Engineering, Tunnel Endpoint24) Фирменный знак: Tractor England25) СМИ: Text Element26) Глоссарий компании Сахалин Энерджи: транзитный коммутатор (станция, transit exchange)27) Нефтепромысловый: TurboExpander28) Сетевые технологии: Termination Enable, эффективность информационного обмена, эффективность трафика29) Программирование: Table Expression, Type Entry30) Сахалин Р: transit exchange31) Химическое оружие: Technical escort, Temperature Element32) Безопасность: Transmission Encryption, Trunk Encryption33) Электротехника: telemetering equipment, СТ, сторона турбины (турбогенератора)34) Должность: Top Executive, Tutor Evaluator35) NYSE. TECO Energy, Inc.36) Программное обеспечение: Table Editor -
19 Te
1) Общая лексика: hum. сокр. Tissue Engineering2) Компьютерная техника: traffic efficiency3) Биология: transposable element4) Медицина: эхо-время, время появления эхо-сигнала (КТ), tissue equalization5) Спорт: Team Effort, Team Efforts, Tilt End, Tournament Edition6) Военный термин: Tactical Exploitation, Test Edition, Thermal Eagle, Third Eye, Tracking Error, Treachery Element, table of equipment, tactical element, tactical employment, tactical environment, tangent elevation, tank element, target elevation, target evaluation, task element, task evaluation, telecommunication engineering, terminal exchange, test and evaluation, test equipment, threat evaluation, topographical engineer, training equipment, training establishment, transporter-erector, ФЦО7) Техника: Terminal Exchanges, Trunk Equalizers, telemetric equipment, thermal efficiency, timing electronics, tractive effort, transducer efficiency, transferred electron, transversely excited8) Химия: Toxicity Equivalent9) Железнодорожный термин: Tacoma Eastern Railway Company10) Юридический термин: Temperament Edit, Trace Evidence11) Бухгалтерия: Total Expenditure, Total Expenses12) Автомобильный термин: thermal expansion13) Оптика: thermoelectric14) Политика: Tromelin Island15) Телекоммуникации: Terminal Equipment (ISDN)16) Сокращение: Tactical Evaluation, Technical Commission, Technical Evaluation, Teileinheit (Единица ширины. 1 TE = 5,08 мм), Telugu, Trailing Edge, Transitional Employees (USPS, 2008), tables of equipment, tax exempt, test and evaluate, testing, thermal element, totally enclosed, trade expenses, transverse electric, эквивалент токсичности, токсический эквивалент17) Университет: Technology And Engineering, Thoroughly Educated18) Физиология: Tamper Evident, Therapeutic exercises, Throat Erosion, Transposon Excision, Triggered Effects19) Электроника: Electron Temperature, Top Electrode, Total Efficiency20) Нефть: twin-engined, испытательное оборудование (testing equipment), оценка технических характеристик (technical evaluation)21) Связь: terminal equipment22) Биотехнология: Tissue Equivalent23) Транспорт: Tank Economy, Traffic Engineering, Tunnel Endpoint24) Фирменный знак: Tractor England25) СМИ: Text Element26) Глоссарий компании Сахалин Энерджи: транзитный коммутатор (станция, transit exchange)27) Нефтепромысловый: TurboExpander28) Сетевые технологии: Termination Enable, эффективность информационного обмена, эффективность трафика29) Программирование: Table Expression, Type Entry30) Сахалин Р: transit exchange31) Химическое оружие: Technical escort, Temperature Element32) Безопасность: Transmission Encryption, Trunk Encryption33) Электротехника: telemetering equipment, СТ, сторона турбины (турбогенератора)34) Должность: Top Executive, Tutor Evaluator35) NYSE. TECO Energy, Inc.36) Программное обеспечение: Table Editor -
20 net
1) Компьютерная техника: Null End Tag2) Медицина: norethisterone, neuroendocrine tumor (нейроэндокринная опухоль)3) Американизм: National Electrotechnical Training, Natural Environment Training4) Военный термин: network, new equipment training, nuclear effects test, nuclear emergency team5) Техника: Next European Tokamak6) Шутливое выражение: Nuts! Everything's Taken7) Религия: National Evangelization Teams, Neighborhood Evangelism Training, New Evangelism Technologies8) Юридический термин: Narcotics Eradication Team9) Грубое выражение: Nitwit Endless Trades10) Оптика: noise equivalent temperature11) Сокращение: National Educational Television, New England Telephone, Normal Environmental Temperature, not earlier than12) Театр: Non Equity Theater13) Университет: Nurse Entrance Test14) Физиология: National Emphysema Treatment, Neuro Emotional Technique16) Деловая лексика: No Earlier Than17) Образование: Never Ever Try18) Интернет: Major Network support centers19) Расширение файла: Network Configuration/ Information file20) Общественная организация: National Environmental Trust21) NYSE. North European Oil Realty Trust22) СМС: Not Entirely True
- 1
- 2
См. также в других словарях:
Temperature play — is a form of sensual play where objects and substances are used to stimulate the body s neuroreceptors for heat and cold for sensual effect. Substances can include water, oil, molten wax, ice, chocolate syrup, whipped cream, melted butter,… … Wikipedia
Effects of global warming — This article is about (primarily) effects during the 21st century. For longer term effects, see Long term effects of global warming. The variou … Wikipedia
Effects of MDMA on the human body — This article discusses the effects of MDMA (3,4 methylenedioxy N methylamphetamine, commonly known as Ecstasy ) on the human brain and body. More general information on MDMA, such as history and legal status, can be found in the main entry for… … Wikipedia
Effects of global warming on Australia — This article is about predicted impacts of Climate change and Global warming on Australia and its climate. Australia is the highest emitter of greenhouse gases per capita in the developed world. [ [http://www.cana.net.au/index.php?site var=337… … Wikipedia
Effects of global warming on South Asia — Lakshadweep, comprising tiny low lying islands, are at risk of being inundated by sea level rises associated with global warming. The effects of global warming on the Indian subcontinent vary from the submergence of low lying islands and coastal… … Wikipedia
Effects of nuclear explosions — An American nuclear test. Nuclear weapons … Wikipedia
Temperature record — For extreme records instead of records as a set of data, see Temperature extremes For instrument derived temperature records, see Instrumental temperature record … Wikipedia
Effects of high altitude on humans — Climbing Mount Rainier. The effects of high altitude on humans are considerable. The percentage saturation of hemoglobin with oxygen determines the content of oxygen in our blood. After the human body reaches around 2,100 m (7,000 feet) above sea … Wikipedia
Temperature-responsive polymer — A temperature responsive polymer is a polymer which undergoes a physical change when external thermal stimuli are presented. The ability to undergo such changes under easily controlled conditions makes this class of polymers fall into the… … Wikipedia
Effects of climate change on marine mammals — Climate change is a cause of increasing concern to scientists and it will have dramatic effects on marine mammals. The increase of carbon dioxide and other greenhouse gases into the atmosphere are thought to be the main cause of climate change or … Wikipedia
Effects of cannabis — Short term effects of cannabis Classification and external resources ICD 10 F12.0 The effects of cannabis are caused by cannabinoids, most notably tetrahydrocannabinol (THC). Cannabis has both psychological and physiological effects on the human… … Wikipedia