Перевод: с французского на русский

с русского на французский

provides+for

  • 1 dispositif d'évacuation

    1. труба для сброса отходов

     

    труба для сброса отходов

    [ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    EN

    exhaust device
    1) A duct or pipe through which waste material is emitted.
    2) A combination of components which provides for enclosed flow of exhaust gas from engine parts to the atmosphere.
    (Source: AMHER / LEE)
    [http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    Тематики

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > dispositif d'évacuation

  • 2 appareillage recouvert de métal

    1. комплектное распределительное устройство в металлической оболочке

     

    комплектное распределительное устройство в металлической оболочке
    -

    EN

    metal-enclosed switchgear
    switchgear assemblies with an external metallic enclosure intended to be earthed and complete except for external connections
    NOTE The metal-enclosed switchgear is subdivided into three types:
    – metal-clad switchgear;
    – compartmented switchgear (with one or more non-metallic partitions);
    – cubicle switchgear
    [IEC 61992-1, ed. 2.0 (2006-02)]

    metal-clad switchgear
    metal-enclosed switchgear in which components are arranged in separate compartments with metal partitions intended to be earthed
    NOTE 1 This term applies to metal-enclosed switchgear with metal partitions providing the degree of protection (or higher) included in IEC 61992-6 and having separate compartments at least for the following components:
    – each main switching device;
    – components connected to one side of a main switching device, for example, feeder circuit;
    – components connected to the other side of the main switching device, for example, busbars; where more than one set of busbars is provided, each set is in a separate compartment.
    NOTE 2 Metal-enclosed switchgear having metal partitions and meeting all the requirements of NOTE 1 may utilise an insulating shutter barrier as a part of a shutter arrangement, the combination of which provides the degree of protection included in Table 1 of IEC 61992-6 (or higher) and satisfies the requirements of the standard for partitions and shutters made of insulating material.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    compartmented switchgear (with non-metallic partitions)

    metal-enclosed switchgear in which components are arranged in separate compartments as for metal-clad switchgear, but with one or more non-metallic partitions providing the degree of protection (or higher) included in Table 1 of IEC 61992-6
    NOTE Metal-enclosed switchgear in which the main circuit components are individually embedded in solid insulating material can be considered as an alternative, provided that the conditions specified in IEC 60466 are met.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    cubicle switchgear
    switchgear, other than metal-clad and compartmented switchgear
    NOTE This term applies to switchgear having a metal enclosure and having
    – a number of compartments fewer than required for metal-clad or compartmented switchgear, or
    – partitions having a degree of protection lower than those indicated in Table 1 of IEC 61992-6, or
    – no partitions.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    FR

    appareillage sous enveloppe métallique
    ensemble d’appareillage avec une enveloppe métallique externe destinée à être mise à la terre, entièrement terminé, à l’exception des connexions extérieures
    NOTE L’appareillage sous enveloppe métallique se subdivise en trois types:
    – appareillage recouvert de métal;
    – appareillage à compartiments (avec une ou plusieurs cloisons non métalliques);
    – appareillage d’armoire.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    appareillage recouvert de métal
    appareillage sous enveloppe métallique dans lequel les éléments constitutifs sont disposés dans des compartiments séparés par des cloisons métalliques destinées à être mises à la terre
    NOTE 1 Ce terme s’applique à l’appareillage sous enveloppe métallique avec des cloisons métalliques offrant le degré de protection de la CEI 61992-6 (ou un degré supérieur) et ayant des compartiments séparés au moins pour les éléments constitutifs suivants:
    – chaque appareil principal de connexion;
    – les éléments constitutifs connectés à une face de l'appareil principal de connexion, par exemple le circuit d’alimentation;
    – les éléments constitutifs connectés à l’autre face de l'appareil principal de connexion, par exemple les jeux de barres; lorsqu’il y a plus d’un jeu de barres, chaque jeu est dans un compartiment séparé.
    NOTE 2 L’appareillage sous enveloppe métallique qui possède des cloisons métalliques et qui répond à toutes les dispositions de la note 1 peut utiliser une barrière en volet isolant comme une partie d’une disposition de volet, dont la combinaison fournit un degré de protection inclus au Tableau 1 de la CEI 61992-6 (ou un degré supérieur) et satisfait aux exigences de la norme pour les cloisons et les volets en matériau isolant.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    appareillage à compartiments (avec cloisons non métalliques)
    appareillage sous enveloppe métallique dans lequel les éléments constitutifs sont disposés dans des compartiments séparés comme pour l’appareillage recouvert de métal, mais avec une ou plusieurs cloisons non métalliques fournissant le degré de protection du Tableau 1 de la CEI 61992-6 (ou un degré supérieur)
    NOTE L’appareillage sous enveloppe métallique dans lequel les éléments constitutifs du circuit principal sont noyés individuellement dans un matériau isolant solide peut être considéré comme une alternative, si les conditions spécifiées dans la CEI 60466 sont satisfaites.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    pareillage d’armoire

    appareillage, autre que l’appareillage recouvert de métal ou à compartiments
    NOTE Ce terme s’applique à l’appareillage ayant une enveloppe métallique et ayant:
    – soit un nombre de compartiments inférieur à celui exigé pour les appareillages recouverts de métal ou à compartiments;
    – soit des cloisons d’un degré de protection inférieur à ceux du Tableau 1 de la CEI 61992-6;
    – soit pas de cloisons.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    0615

    Комплектное распределительное устройство в металлической оболочке
    Рис. ABB

    ГОСТ 14693-90 - Устройства комплектные распределительные негерметизированные в металлической оболочке на напряжение до 10 кВ

    Тематики

    • комплектное распред. устройство (КРУ)

    Синонимы

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > appareillage recouvert de métal

  • 3 appareillage sous enveloppe métallique

    1. комплектное устройство в металлической оболочке
    2. комплектное распределительное устройство в металлической оболочке

     

    комплектное распределительное устройство в металлической оболочке
    -

    EN

    metal-enclosed switchgear
    switchgear assemblies with an external metallic enclosure intended to be earthed and complete except for external connections
    NOTE The metal-enclosed switchgear is subdivided into three types:
    – metal-clad switchgear;
    – compartmented switchgear (with one or more non-metallic partitions);
    – cubicle switchgear
    [IEC 61992-1, ed. 2.0 (2006-02)]

    metal-clad switchgear
    metal-enclosed switchgear in which components are arranged in separate compartments with metal partitions intended to be earthed
    NOTE 1 This term applies to metal-enclosed switchgear with metal partitions providing the degree of protection (or higher) included in IEC 61992-6 and having separate compartments at least for the following components:
    – each main switching device;
    – components connected to one side of a main switching device, for example, feeder circuit;
    – components connected to the other side of the main switching device, for example, busbars; where more than one set of busbars is provided, each set is in a separate compartment.
    NOTE 2 Metal-enclosed switchgear having metal partitions and meeting all the requirements of NOTE 1 may utilise an insulating shutter barrier as a part of a shutter arrangement, the combination of which provides the degree of protection included in Table 1 of IEC 61992-6 (or higher) and satisfies the requirements of the standard for partitions and shutters made of insulating material.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    compartmented switchgear (with non-metallic partitions)

    metal-enclosed switchgear in which components are arranged in separate compartments as for metal-clad switchgear, but with one or more non-metallic partitions providing the degree of protection (or higher) included in Table 1 of IEC 61992-6
    NOTE Metal-enclosed switchgear in which the main circuit components are individually embedded in solid insulating material can be considered as an alternative, provided that the conditions specified in IEC 60466 are met.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    cubicle switchgear
    switchgear, other than metal-clad and compartmented switchgear
    NOTE This term applies to switchgear having a metal enclosure and having
    – a number of compartments fewer than required for metal-clad or compartmented switchgear, or
    – partitions having a degree of protection lower than those indicated in Table 1 of IEC 61992-6, or
    – no partitions.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    FR

    appareillage sous enveloppe métallique
    ensemble d’appareillage avec une enveloppe métallique externe destinée à être mise à la terre, entièrement terminé, à l’exception des connexions extérieures
    NOTE L’appareillage sous enveloppe métallique se subdivise en trois types:
    – appareillage recouvert de métal;
    – appareillage à compartiments (avec une ou plusieurs cloisons non métalliques);
    – appareillage d’armoire.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    appareillage recouvert de métal
    appareillage sous enveloppe métallique dans lequel les éléments constitutifs sont disposés dans des compartiments séparés par des cloisons métalliques destinées à être mises à la terre
    NOTE 1 Ce terme s’applique à l’appareillage sous enveloppe métallique avec des cloisons métalliques offrant le degré de protection de la CEI 61992-6 (ou un degré supérieur) et ayant des compartiments séparés au moins pour les éléments constitutifs suivants:
    – chaque appareil principal de connexion;
    – les éléments constitutifs connectés à une face de l'appareil principal de connexion, par exemple le circuit d’alimentation;
    – les éléments constitutifs connectés à l’autre face de l'appareil principal de connexion, par exemple les jeux de barres; lorsqu’il y a plus d’un jeu de barres, chaque jeu est dans un compartiment séparé.
    NOTE 2 L’appareillage sous enveloppe métallique qui possède des cloisons métalliques et qui répond à toutes les dispositions de la note 1 peut utiliser une barrière en volet isolant comme une partie d’une disposition de volet, dont la combinaison fournit un degré de protection inclus au Tableau 1 de la CEI 61992-6 (ou un degré supérieur) et satisfait aux exigences de la norme pour les cloisons et les volets en matériau isolant.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    appareillage à compartiments (avec cloisons non métalliques)
    appareillage sous enveloppe métallique dans lequel les éléments constitutifs sont disposés dans des compartiments séparés comme pour l’appareillage recouvert de métal, mais avec une ou plusieurs cloisons non métalliques fournissant le degré de protection du Tableau 1 de la CEI 61992-6 (ou un degré supérieur)
    NOTE L’appareillage sous enveloppe métallique dans lequel les éléments constitutifs du circuit principal sont noyés individuellement dans un matériau isolant solide peut être considéré comme une alternative, si les conditions spécifiées dans la CEI 60466 sont satisfaites.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    pareillage d’armoire

    appareillage, autre que l’appareillage recouvert de métal ou à compartiments
    NOTE Ce terme s’applique à l’appareillage ayant une enveloppe métallique et ayant:
    – soit un nombre de compartiments inférieur à celui exigé pour les appareillages recouverts de métal ou à compartiments;
    – soit des cloisons d’un degré de protection inférieur à ceux du Tableau 1 de la CEI 61992-6;
    – soit pas de cloisons.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    0615

    Комплектное распределительное устройство в металлической оболочке
    Рис. ABB

    ГОСТ 14693-90 - Устройства комплектные распределительные негерметизированные в металлической оболочке на напряжение до 10 кВ

    Тематики

    • комплектное распред. устройство (КРУ)

    Синонимы

    EN

    FR

     

    комплектное устройство в металлической оболочке
    -

    EN

    metal-enclosed switchgear and controlgear
    switchgear and controlgear assemblies with an external metal enclosure intended to be earthed, and complete except for external connections
    [IEC 62271-203, ed. 1.0 (2003-11)]

    FR

    appareillage sous enveloppe métallique
    appareillage avec une enveloppe métallique externe destinée à être mise à la terre, entièrement terminé, à l'exception des connexions extérieures
    [IEC 62271-203, ed. 1.0 (2003-11)]

    0078  0083  0086
    Комплектные устройства в металлической оболочке

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > appareillage sous enveloppe métallique

  • 4 appareillage à compartiments (avec cloisons non métalliques)

    1. комплектное распределительное устройство в металлической оболочке

     

    комплектное распределительное устройство в металлической оболочке
    -

    EN

    metal-enclosed switchgear
    switchgear assemblies with an external metallic enclosure intended to be earthed and complete except for external connections
    NOTE The metal-enclosed switchgear is subdivided into three types:
    – metal-clad switchgear;
    – compartmented switchgear (with one or more non-metallic partitions);
    – cubicle switchgear
    [IEC 61992-1, ed. 2.0 (2006-02)]

    metal-clad switchgear
    metal-enclosed switchgear in which components are arranged in separate compartments with metal partitions intended to be earthed
    NOTE 1 This term applies to metal-enclosed switchgear with metal partitions providing the degree of protection (or higher) included in IEC 61992-6 and having separate compartments at least for the following components:
    – each main switching device;
    – components connected to one side of a main switching device, for example, feeder circuit;
    – components connected to the other side of the main switching device, for example, busbars; where more than one set of busbars is provided, each set is in a separate compartment.
    NOTE 2 Metal-enclosed switchgear having metal partitions and meeting all the requirements of NOTE 1 may utilise an insulating shutter barrier as a part of a shutter arrangement, the combination of which provides the degree of protection included in Table 1 of IEC 61992-6 (or higher) and satisfies the requirements of the standard for partitions and shutters made of insulating material.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    compartmented switchgear (with non-metallic partitions)

    metal-enclosed switchgear in which components are arranged in separate compartments as for metal-clad switchgear, but with one or more non-metallic partitions providing the degree of protection (or higher) included in Table 1 of IEC 61992-6
    NOTE Metal-enclosed switchgear in which the main circuit components are individually embedded in solid insulating material can be considered as an alternative, provided that the conditions specified in IEC 60466 are met.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    cubicle switchgear
    switchgear, other than metal-clad and compartmented switchgear
    NOTE This term applies to switchgear having a metal enclosure and having
    – a number of compartments fewer than required for metal-clad or compartmented switchgear, or
    – partitions having a degree of protection lower than those indicated in Table 1 of IEC 61992-6, or
    – no partitions.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    FR

    appareillage sous enveloppe métallique
    ensemble d’appareillage avec une enveloppe métallique externe destinée à être mise à la terre, entièrement terminé, à l’exception des connexions extérieures
    NOTE L’appareillage sous enveloppe métallique se subdivise en trois types:
    – appareillage recouvert de métal;
    – appareillage à compartiments (avec une ou plusieurs cloisons non métalliques);
    – appareillage d’armoire.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    appareillage recouvert de métal
    appareillage sous enveloppe métallique dans lequel les éléments constitutifs sont disposés dans des compartiments séparés par des cloisons métalliques destinées à être mises à la terre
    NOTE 1 Ce terme s’applique à l’appareillage sous enveloppe métallique avec des cloisons métalliques offrant le degré de protection de la CEI 61992-6 (ou un degré supérieur) et ayant des compartiments séparés au moins pour les éléments constitutifs suivants:
    – chaque appareil principal de connexion;
    – les éléments constitutifs connectés à une face de l'appareil principal de connexion, par exemple le circuit d’alimentation;
    – les éléments constitutifs connectés à l’autre face de l'appareil principal de connexion, par exemple les jeux de barres; lorsqu’il y a plus d’un jeu de barres, chaque jeu est dans un compartiment séparé.
    NOTE 2 L’appareillage sous enveloppe métallique qui possède des cloisons métalliques et qui répond à toutes les dispositions de la note 1 peut utiliser une barrière en volet isolant comme une partie d’une disposition de volet, dont la combinaison fournit un degré de protection inclus au Tableau 1 de la CEI 61992-6 (ou un degré supérieur) et satisfait aux exigences de la norme pour les cloisons et les volets en matériau isolant.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    appareillage à compartiments (avec cloisons non métalliques)
    appareillage sous enveloppe métallique dans lequel les éléments constitutifs sont disposés dans des compartiments séparés comme pour l’appareillage recouvert de métal, mais avec une ou plusieurs cloisons non métalliques fournissant le degré de protection du Tableau 1 de la CEI 61992-6 (ou un degré supérieur)
    NOTE L’appareillage sous enveloppe métallique dans lequel les éléments constitutifs du circuit principal sont noyés individuellement dans un matériau isolant solide peut être considéré comme une alternative, si les conditions spécifiées dans la CEI 60466 sont satisfaites.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    pareillage d’armoire

    appareillage, autre que l’appareillage recouvert de métal ou à compartiments
    NOTE Ce terme s’applique à l’appareillage ayant une enveloppe métallique et ayant:
    – soit un nombre de compartiments inférieur à celui exigé pour les appareillages recouverts de métal ou à compartiments;
    – soit des cloisons d’un degré de protection inférieur à ceux du Tableau 1 de la CEI 61992-6;
    – soit pas de cloisons.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    0615

    Комплектное распределительное устройство в металлической оболочке
    Рис. ABB

    ГОСТ 14693-90 - Устройства комплектные распределительные негерметизированные в металлической оболочке на напряжение до 10 кВ

    Тематики

    • комплектное распред. устройство (КРУ)

    Синонимы

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > appareillage à compartiments (avec cloisons non métalliques)

  • 5 pareillage d’armoire

    1. комплектное распределительное устройство в металлической оболочке

     

    комплектное распределительное устройство в металлической оболочке
    -

    EN

    metal-enclosed switchgear
    switchgear assemblies with an external metallic enclosure intended to be earthed and complete except for external connections
    NOTE The metal-enclosed switchgear is subdivided into three types:
    – metal-clad switchgear;
    – compartmented switchgear (with one or more non-metallic partitions);
    – cubicle switchgear
    [IEC 61992-1, ed. 2.0 (2006-02)]

    metal-clad switchgear
    metal-enclosed switchgear in which components are arranged in separate compartments with metal partitions intended to be earthed
    NOTE 1 This term applies to metal-enclosed switchgear with metal partitions providing the degree of protection (or higher) included in IEC 61992-6 and having separate compartments at least for the following components:
    – each main switching device;
    – components connected to one side of a main switching device, for example, feeder circuit;
    – components connected to the other side of the main switching device, for example, busbars; where more than one set of busbars is provided, each set is in a separate compartment.
    NOTE 2 Metal-enclosed switchgear having metal partitions and meeting all the requirements of NOTE 1 may utilise an insulating shutter barrier as a part of a shutter arrangement, the combination of which provides the degree of protection included in Table 1 of IEC 61992-6 (or higher) and satisfies the requirements of the standard for partitions and shutters made of insulating material.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    compartmented switchgear (with non-metallic partitions)

    metal-enclosed switchgear in which components are arranged in separate compartments as for metal-clad switchgear, but with one or more non-metallic partitions providing the degree of protection (or higher) included in Table 1 of IEC 61992-6
    NOTE Metal-enclosed switchgear in which the main circuit components are individually embedded in solid insulating material can be considered as an alternative, provided that the conditions specified in IEC 60466 are met.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    cubicle switchgear
    switchgear, other than metal-clad and compartmented switchgear
    NOTE This term applies to switchgear having a metal enclosure and having
    – a number of compartments fewer than required for metal-clad or compartmented switchgear, or
    – partitions having a degree of protection lower than those indicated in Table 1 of IEC 61992-6, or
    – no partitions.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    FR

    appareillage sous enveloppe métallique
    ensemble d’appareillage avec une enveloppe métallique externe destinée à être mise à la terre, entièrement terminé, à l’exception des connexions extérieures
    NOTE L’appareillage sous enveloppe métallique se subdivise en trois types:
    – appareillage recouvert de métal;
    – appareillage à compartiments (avec une ou plusieurs cloisons non métalliques);
    – appareillage d’armoire.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    appareillage recouvert de métal
    appareillage sous enveloppe métallique dans lequel les éléments constitutifs sont disposés dans des compartiments séparés par des cloisons métalliques destinées à être mises à la terre
    NOTE 1 Ce terme s’applique à l’appareillage sous enveloppe métallique avec des cloisons métalliques offrant le degré de protection de la CEI 61992-6 (ou un degré supérieur) et ayant des compartiments séparés au moins pour les éléments constitutifs suivants:
    – chaque appareil principal de connexion;
    – les éléments constitutifs connectés à une face de l'appareil principal de connexion, par exemple le circuit d’alimentation;
    – les éléments constitutifs connectés à l’autre face de l'appareil principal de connexion, par exemple les jeux de barres; lorsqu’il y a plus d’un jeu de barres, chaque jeu est dans un compartiment séparé.
    NOTE 2 L’appareillage sous enveloppe métallique qui possède des cloisons métalliques et qui répond à toutes les dispositions de la note 1 peut utiliser une barrière en volet isolant comme une partie d’une disposition de volet, dont la combinaison fournit un degré de protection inclus au Tableau 1 de la CEI 61992-6 (ou un degré supérieur) et satisfait aux exigences de la norme pour les cloisons et les volets en matériau isolant.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    appareillage à compartiments (avec cloisons non métalliques)
    appareillage sous enveloppe métallique dans lequel les éléments constitutifs sont disposés dans des compartiments séparés comme pour l’appareillage recouvert de métal, mais avec une ou plusieurs cloisons non métalliques fournissant le degré de protection du Tableau 1 de la CEI 61992-6 (ou un degré supérieur)
    NOTE L’appareillage sous enveloppe métallique dans lequel les éléments constitutifs du circuit principal sont noyés individuellement dans un matériau isolant solide peut être considéré comme une alternative, si les conditions spécifiées dans la CEI 60466 sont satisfaites.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    pareillage d’armoire

    appareillage, autre que l’appareillage recouvert de métal ou à compartiments
    NOTE Ce terme s’applique à l’appareillage ayant une enveloppe métallique et ayant:
    – soit un nombre de compartiments inférieur à celui exigé pour les appareillages recouverts de métal ou à compartiments;
    – soit des cloisons d’un degré de protection inférieur à ceux du Tableau 1 de la CEI 61992-6;
    – soit pas de cloisons.
    [IEC 61992-1, ed. 2.0 (2006-02)]

    0615

    Комплектное распределительное устройство в металлической оболочке
    Рис. ABB

    ГОСТ 14693-90 - Устройства комплектные распределительные негерметизированные в металлической оболочке на напряжение до 10 кВ

    Тематики

    • комплектное распред. устройство (КРУ)

    Синонимы

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > pareillage d’armoire

  • 6 culture industrielle

    1. товарная сельскохозяйственная культура
    2. промышленная культура

     

    промышленная культура

    [ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    EN

    industrial crop
    Any crop that provides materials for industrial processes and products such as soybeans, cotton (lint and seed), flax, and tobacco. (Source: MGH)
    [http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    Тематики

    EN

    DE

    FR

     

    товарная сельскохозяйственная культура

    [ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    EN

    cash crop
    Crops that are grown for sale in the town markets or for export. They include coffee, cocoa, sugar, vegetables, peanuts and non-foods, like tobacco and cotton. Huge areas of countries in the developing world have been turned over to cash crops. Those countries with no mineral or oil resources depend on cash crops for foreign money, so that they can import materials do develop roads, for construction, or to buy Western consumer goods and, indeed, food. However, critics argue that cash crops are planted on land that would otherwise be used to grow food for the local community and say this is a cause of world famine. Cash crops, such as peanuts, can ruin the land if it is not left fallow after six years of harvests. Moreover, if the best agricultural land is used for cash crops, local farmers are forced to use marginal land to grow food for local consumption, and this has a further dramatic effect on the environment. (Source: WRIGHT)
    [http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    Тематики

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > culture industrielle

  • 7 sectionneur

    1. разъединитель

     

    разъединитель
    Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
    Примечание.
    1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
    Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.

    0043 Условное обозначение контакта разъединителя

    [ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]

    разъединитель
    Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
    Примечания
    1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
    2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
    3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
    4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
    [ ГОСТ Р 52726-2007]

    EN

    disconnector
    a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
    NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
    [IEV number 441-14-05]

    disconnector

    IEV 441-14-05 is applicable with the following additional notes:
    NOTE 1
    "Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
    "No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
    NOTE 2
    For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
    [IEC 62271-102]

    FR

    sectionneur
    appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
    NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
    [IEV number 441-14-05]

    Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:

    • изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
    • иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
    • быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
    • обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;

    [ ГОСТ Р МЭК 60204-1-2007]


    Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
    Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
    Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
    Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:

    1. Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
    2. Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
    3. Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
    4. Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
    5. Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
    6. Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.

    [ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]


    Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
    [ http://relay-protection.ru/content/view/46/8/1/1/]


    Параллельные тексты EN-RU

    b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
    [IEC 60204-1-2006]

    б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
    [Перевод Интент]

    Тематики

    • высоковольтный аппарат, оборудование...
    • релейная защита
    • электротехника, основные понятия

    Классификация

    >>>

    EN

    DE

    FR

    Смотри также

    Франко-русский словарь нормативно-технической терминологии > sectionneur

  • 8 broussaille

    1. кустарниковые заросли

     

    кустарниковые заросли

    [ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    EN

    brushwood
    Woody vegetation including shrubs and scrub trees of non-commercial height and form, often seen in the initial stages of succession following a disturbance. Brush often grows in very dense thickets that are impenetrable to wild animals and serve to suppress the growth of more desirable crop trees. However, brush can also serve an important function as desirable habitat for a range or bird, animal, and invertebrate species, and often provides a good source of browse and cover for larger wildlife. It adds structural diversity within the forest and is important in riparian zones. It is also termed scrub. (Source: DUNSTE)
    [http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]

    Тематики

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > broussaille

  • 9 badge du logo de la compétition

    Badge du logo d'une compétition de l'UEFA fourni par l'UEFA à toutes les équipes participantes, qui doit figurer sur la manche droite du maillot, entre la couture de l'épaule et le coude, tout au long de la compétition en question.
    Badge which UEFA provides to all teams participating in an official UEFA competition for use throughout the event and which must appear on the right sleeve of the players' shirts, between the shoulder seam and the elbow.

    Dictionnaire Français-Anglais (UEFA Football) > badge du logo de la compétition

  • 10 centre d'entraînement

    Ensemble d'installations offrant aux joueurs la possibilité de s'entraîner sous la supervision de professionnels.
    A facility which provides professional instruction for players to improve their skills and fitness.

    Dictionnaire Français-Anglais (UEFA Football) > centre d'entraînement

  • 11 nutriment

    Substance nutritive, directement assimilable sans avoir à subir de transformation digestive.
    A food or other substance that provides energy or building material for the survival and growth of a living organism.

    Dictionnaire Français-Anglais (UEFA Football) > nutriment

  • 12 isolation principale

    1. основная изоляция

     

    основная изоляция
    Изоляция токоведущих частей, обеспечивающая основную защиту от поражения электрическим током.
    [ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]

    основная изоляция
    Изоляция, повреждение которой может вызвать опасность поражения электрическим током.
    Примечание. Основная изоляция может использоваться также по функциональному назначению.
    [ ГОСТ Р 52319-2005( МЭК 61010-1: 2001)]

    основная изоляция
    Изоляция опасных токоведущих частей, которая обеспечивает защиту от прямого прикосновения.
    Примечание - Это не относится к изоляции, используемой исключительно для функциональных целей.
    [ ГОСТ Р МЭК 60050-195-2005]
    [ ГОСТ Р МЭК 60050-826-2009]

    основная изоляция
    изоляция, применяемая к находящимся под напряжением частям, для обеспечения основной защиты от поражения электрическим током.
    Примечание - Основная изоляция не обязательно включает изоляцию, используемую исключительно для функциональных целей.
    [ ГОСТ 6570-96]

    основная изоляция
    Изоляция опасных токоведущих частей, предназначенная для обеспечения основной защиты.
    Когда основная изоляция находится в неповреждённом состоянии, не может произойти прямого прикосновения, поскольку основная изоляция препятствует прикосновению человека и животных к находящимся под напряжением опасным токоведущим частям. При условиях отсутствия повреждений не может быть косвенного прикосновения, поскольку открытые проводящие части электрооборудования отделены от опасных токоведущих частей основной изоляцией. Поэтому они не могут оказаться под напряжением и представлять опасность для человека и животных.
    [ http://www.volt-m.ru/glossary/letter/%CE/view/43/]

    EN

    basic insulation
    insulation applied to live parts to provide basic protection against electric shock
    [IEC 60335-1, ed. 4.0 (2001-05)]


    basic insulation
    insulation of hazardous-live-parts which provides basic protection
    NOTE – This concept does not apply to insulation used exclusively for functional purposes.
    Source: 826-03-17 MOD
    [IEV number 195-06-06]

    FR

    isolation principale
    isolation des parties actives destinée à assurer la protection principale contre les chocs électriques
    [IEC 60335-1, ed. 4.0 (2001-05)]


    isolation principale
    isolation des parties actives dangereuses qui assure la protection principale
    NOTE – Cette notion n'est pas applicable à l'isolation exclusivement utilisée à des fins fonctionnelles.
    Source: 826-03-17 MOD
    [IEV number 195-06-06]

    Тематики

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > isolation principale

  • 13 démarrage direct

    1. прямой пуск вращающегося электродвигателя

     

    прямой пуск вращающегося электродвигателя
    Пуск вращающегося электродвигателя путем непосредственного подключения его к питающей сети.
    [ ГОСТ 27471-87]

    EN

    direct-on-line starting
    across-the-line starting (US)
    the process of starting a motor by connecting it directly to the supply at rated voltage
    [IEV number 411-52-15]

    FR

    démarrage direct
    mode de démarrage d'un moteur, consistant à lui appliquer directement sa pleine tension assignée
    [IEV number 411-52-15]

    0855
    Рис. ABB
    Схема прямого пуска электродвигателя

    Magnetic only circuit-breaker - Автоматический выключатель с электромагнитным расцепителем

    Contactor KL - Контактор KL

    Thermal relay - Тепловое реле

     

    Параллельные тексты EN-RU

    Direct-on-line starting

    Direct-on-line starting, which is often abbreviated as DOL, is perhaps the most traditional system and consists in connecting the motor directly to the supply network, thus carrying out starting at full voltage.

    Direct-on-line starting represents the simplest and the most economical system to start a squirrel-cage asynchronous motor and it is the most used.

    As represented in Figure 5, it provides the direct connection to the supply network and therefore starting is carried out at full voltage and with constant frequency, developing a high starting torque with very reduced acceleration times.

    The typical applications are relevant to small power motors also with full load starting.

    These advantages are linked to some problems such as, for example, the high inrush current, which - in the first instants - can reach values of about 10 to 12 times the rated current, then can decrease to about 6 to 8 times the rated current and can persist to reach the maximum torque speed.

    The effects of such currents can be identified with the high electro-dynamical stresses on the motor connection cables and could affect also the windings of the motor itself; besides, the high inrush torques can cause violent accelerations which stress the transmission components (belts and joints) generating distribution problems with a reduction in the mechanical life of these elements.

    Finally, also the possible electrical problems due to voltage drops on the supply line of the motor or of the connected equipment must be taken into consideration.
    [ABB]

    Прямой пуск

    Прямой пуск, который по-английски часто сокращенно обозначают как DOL, является, пожалуй наиболее распространенным способом пуска. Он заключается в непосредственном (т. е. прямом) подключении двигателя к питающей сети. Это означает, что пуск двигателя осуществляется при полном напряжении.

    Схема прямого пуска является наиболее простым, экономичным и чаще всего применяемым решением для электродвигателей с короткозамкнутым ротором.

    Схема прямого подключения к сети представлена на рисунке 5. Пуск осуществляется при полном напряжении и постоянной частоте сети. Электродвигатель развивает высокий пусковой момент при коротком времени разгона.

    Типичные области применения – маломощные электродвигатели, в том числе с пуском при полной нагрузке.

    Однако, наряду с преимуществами имеются и определенные недостатки, например, бросок пускового тока, достигающий в первоначальный момент 10…12-кратного значения от номинального тока электродвигателя. Затем ток двигателя уменьшается примерно до 6…8-кратного значения номинального тока и будет держаться на этом уровне до тех пор, пока скорость двигателя не достигнет максимального значения.

    Такое изменение тока оказывает значительное электродинамическое воздействие на кабель, подключенный к двигателю. Кроме того пусковой ток воздействует на обмотки двигателя. Высокий начальный пусковой момент может привести к значительному ускорению и следовательно к значительной нагрузке элементов привода (ремней, крепления узлов), что вызывает сокращение их срока службы.

    И, наконец, следует принять во внимание возможное возникновение проблем, связанных с падением напряжения в линии питания двигателя и подключенного к этой линии оборудования.
    [Перевод Интент]




     

    Тематики

    Синонимы

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > démarrage direct

  • 14 socle à verrouillage

    1. розетка с блокировкой

     

    розетка с блокировкой
    -
    [IEV number 442-03-06]

    EN

    interlocked socket-outlet
    socket‑outlet which provides interlock of a plug, which is specially designed for this additional function
    [IEV number 442-03-06]

    FR

    socle à verrouillage
    socle de prise de courant assurant le verrouillage d'une fiche, qui est spécialement conçue pour cette fonction additionnelle
    [IEV number 442-03-06]

    См. также блокировка вилки

    Тематики

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > socle à verrouillage

  • 15 réseau de communication

    1. сеть связи

     

    сеть связи

    [http://www.rfcmd.ru/glossword/1.8/index.php?a=index&d=23]

    EN

    communication network
    system of communication nodes and links that provides transmission of analog or digital signals

    EXAMPLES Telecommunications networks, Internet, intranet, extranet, Wide Area Networks (WAN), Local Area Networks (LAN) and computer networking utilizing information technology.

    NOTE 1 A network has its boundary. All nodes at the network boundary are called ends. In some applications, the term “node” is used instead of “end” as a communication access point to the network, as well as for interconnections between the transmission links.

    NOTE 2 A “backbone” communication network consists of core network and high-speed transmission lines (national or international), connecting between major switching network nodes (interconnection of transmission lines) at various locations in a country or region.
    [IEC 61907, ed. 1.0 (2009-12)]

    FR

    réseau de communication
    système constitué de nœuds et de liaisons de communication assurant la transmission des signaux analogiques ou numériques

    EXEMPLES Les réseaux de télécommunications, l’Internet, l'intranet, l’extranet, les réseaux étendus (WAN), les réseaux locaux (d'entreprise) (RLE) et les réseaux informatiques utilisant les technologies de l’information.

    NOTE 1 Un réseau comporte sa propre frontière. L’ensemble des nœuds situés au niveau de la frontière d’un réseau s’appellent des terminaux. Dans certaines applications, le terme «nœud» est utilisé à la place du terme «terminal» comme point d'accès de communication au réseau, ainsi que pour désigner les interconnexions entre les liaisons de transmission.

    NOTE 2 Un réseau de communication «fédérateur» est constitué d’un réseau central et de lignes de transmission à grande vitesse (nationales ou internationales) reliant entre eux des nœuds de réseaux de commutation importants (interconnexion de lignes de transmission) en divers lieux d'un pays ou d'une région.
    [IEC 61907, ed. 1.0 (2009-12)]

    Тематики

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > réseau de communication

См. также в других словарях:

  • For One More Day — is a 2006 novel taken place during the mid 1900 s by the acclaimed sportswriter and author Mitch Albom. It opens with the novel s protagonist planning to commit suicide. His adulthood is shown to have been rife with sadness. His own daughter didn …   Wikipedia

  • for — [ weak fər, strong fɔr ] function word *** For can be used in the following ways: as a preposition (followed by a noun): I bought some flowers for Chloe. Wait there for a while. as a conjunction (connecting two clauses): I told her to leave, for… …   Usage of the words and phrases in modern English

  • For You Hotel Penza (Penza) — For You Hotel Penza country: Russia, city: Penza (City Victory Park) For You Hotel Penza Located in the city of Penza, For You Hotel is set in one of the beautiful Volga Region. The property is 8 kilometres away from the railway station and the… …   International hotels

  • For the Motherland — ( th. พรรคเพื่อแผ่นดิน, transl|th|Pua Paendin ) is a Thai political party founded on 11 September 2007 by more than 200 veteran Thai politicians. Its political stance is neither pro Thaksin nor anti Thaksin and located in the centre of the… …   Wikipedia

  • For Your Eye Alone — published by McClelland and Stewart in 2000, is a collection of letters written by Canadian novelist Robertson Davies.Editor Judith Skelton Grant provides a selection of letters written by Davies from the period starting in 1976 until 1995, the …   Wikipedia

  • for */*/*/ — strong UK [fɔː(r)] / US [fɔr] weak UK [fə(r)] / US [fər] preposition, conjunction Summary: For can be used in the following ways: as a preposition (followed by a noun): I bought some flowers for Chloe. ♦ Wait there for a while. as a conjunction… …   English dictionary

  • for */*/*/ — weak [fə] , strong [fɔː] preposition 1) intended to benefit sb/sth used for saying who or what is intended to receive something or get the benefit of it Claudia, this present is for you.[/ex] The academy provides training for young… …   Dictionary for writing and speaking English

  • Board of Control for Cricket in India — For the defunct bank see Bank of Credit and Commerce International The Board of Control for Cricket in India, or BCCI, is the apex governing body for cricket in India. The board was formed in 1929. It is a society, registered under the Tamil Nadu …   Wikipedia

  • Not for Attribution — For the eponymous category of journalistic sourcing, see Journalism sourcing. Not for Attribution The Wire episode …   Wikipedia

  • For All Mankind — Infobox Film name = For All Mankind caption = DVD cover writer = starring = director = Al Reinert editing = Susan Korda producer = Betsy Broyles Breier Al Reinert Fred Miller distributor = Apollo Associates released = flagicon|USA 1 November,… …   Wikipedia

  • for-pay — adjective By subscription; that must be purchased to use. The websites for pay access provides premium options. Ant: free …   Wiktionary

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»