1 Spannungsunsymmetrie
небаланс напряжений
Отличие по модулю значения хотя бы одного из фазных или линейных напряжений многофазной системы электроснабжения от значений напряжений других фаз.
[ ГОСТ 23875-88]EN
voltage unbalance
phenomenon due to the differences between voltage deviations on the various phases, at a point of a polyphase system, resulting from differences between the phase currents or geometrical asymmetry in the line
[IEV number 604-01-29]
voltage unbalance (imbalance)
in a polyphase system, a condition in which the magnitudes of the phase voltages or the phase angles between consecutive phases are not all equal (fundamental component)
NOTE In three phase systems, the degree of inequality is usually expressed as the ratio of the negative and zero sequence components to the positive sequence component. In this technical report, voltage unbalance is considered in relation to three-phase systems and negative sequence only
[IEC 61000-3-13, ed. 1.0 (2008-02)]
voltage unbalance
condition in a polyphase system in which the r.m.s. values of the line voltages (fundamental component), and/or the phase angles between consecutive line voltages, are not all equal
NOTE 1 The degree of the inequality is usually expressed as the ratios of the negative- and zero-sequence components to the positive-sequence component.
NOTE 2 In this standard, voltage unbalance is considered in relation to 3-phase systems.
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
déséquilibre des tensions d'un réseau
phénomène résultant des différences de charge ou des dissymétries géométriques de lignes et qui provoque des différences entre les écarts de tension sur les diverses phases en un point d'un réseau polyphasé
[IEV number 604-01-29]
déséquilibre de tension
dans un réseau d’énergie électrique polyphasé, état dans lequel les valeurs efficaces des tensions entre conducteurs (composante fondamentale), et/ou les différences de phase entre conducteurs successifs, ne sont pas toutes égales
NOTE 1 Le taux de déséquilibre s’exprime habituellement par le rapport de la composante inverse ou homopolaire à la composante directe.
NOTE 2 Dans la présente norme, le déséquilibre de tension est relatif aux réseaux triphasés
[IEC 61000-4-30, ed. 2.0 (2008-10)]Параллельные тексты EN-RU

Voltage unbalance
Voltage unbalance on the most unbalanced phase, displayed as a percentage of Vavg.
[Schneider Electric]Небаланс напряжений
Самое значительное отличие по модулю значения одного из линейных напряжений, выраженное в процентах от среднего напряжения Vavg.
[Перевод Интент]
Недопустимые, нерекомендуемые
Тематики
EN
DE
FR
Смотри также
Немецко-русский словарь нормативно-технической терминологии > Spannungsunsymmetrie
2 Unsymmetriegrad
- коэффициент обратной последовательности напряжения (тока)
- коэффициент нулевой последовательности напряжения (тока)
коэффициент нулевой последовательности напряжения (тока)
Величина, равная отношению напряжения (тока) нулевой последовательности к фазному напряжению (току) прямой последовательности в многофазной системе электроснабжения.
Примечание. Для целей стандартизации допускается относить к номинальному напряжению (току).
[ ГОСТ 23875-88]EN
unbalance factor
in a three-phase system, the degree of unbalance expressed by the ratio (in per cent) between the r.m.s. values of the negative sequence (or the zero sequence) component and the positive sequence component of voltage or current
[IEV number 604-01-30]FR
taux de déséquilibre
dans un réseau triphasé, expression du degré de déséquilibre par le rapport, exprimé en pourcentage, entre la valeur efficace de chacune des composantes inverse ou homopolaire et celle de la composante directe de la tension ou du courant
[IEV number 604-01-30]Тематики
EN
DE
FR
Смотри также
коэффициент обратной последовательности напряжения (тока)
Величина, равная отношению напряжения (тока) обратной последовательности к напряжению (току) прямой последовательности в многофазной системе электроснабжения.
Примечание. Для целей стандартизации допускается относить к номинальному напряжению (току).
[ ГОСТ 23875-88]EN
unbalance factor
in a three-phase system, the degree of unbalance expressed by the ratio (in per cent) between the r.m.s. values of the negative sequence (or the zero sequence) component and the positive sequence component of voltage or current
[IEV number 604-01-30]FR
taux de déséquilibre
dans un réseau triphasé, expression du degré de déséquilibre par le rapport, exprimé en pourcentage, entre la valeur efficace de chacune des composantes inverse ou homopolaire et celle de la composante directe de la tension ou du courant
[IEV number 604-01-30]Тематики
EN
DE
FR
Смотри также
42. Коэффициент обратной последовательности напряжения (тока)
D. Unsymmetriegrad
E. Unbalance factor
F. Taux de déséquilibre
Величина, равная отношению напряжения (тока) обратной последовательности к напряжению (току) прямой последовательности в многофазной системе электроснабжения.
Примечание. Для целей стандартизации допускается относить к номинальному напряжению (току)
Источник: ГОСТ 23875-88: Качество электрической энергии. Термины и определения оригинал документа
43. Коэффициент нулевой последовательности напряжения (тока)
D. Unsymmetriegrad
E. Unbalance factor
F. Taux de déséquilibre
Величина, равная отношению напряжения (тока) нулевой последовательности к фазному напряжению (току) прямой последовательности в многофазной системе электроснабжения.
Примечание. Для целей стандартизации допускается относить к номинальному напряжению (току)
Источник: ГОСТ 23875-88: Качество электрической энергии. Термины и определения оригинал документа
Немецко-русский словарь нормативно-технической терминологии > Unsymmetriegrad
3 Nullreaktanz
реактивное сопротивление нулевой последовательности
-EN
zero sequence reactance
the quotient of the reactive fundamental component of zero sequence armature voltage, due to the presence of fundamental zero sequence armature current at rated frequency, by the value of that component of current, the machine running at rated speed
[IEV ref 411-50-16]FR
réactance homopolaire
quotient du terme fondamental de la composante réactive de la tension d'induit homopolaire, due à la présence du terme fondamental du courant d'induit homopolaire à fréquence assignée, par cette composante du courant, la machine tournant à sa vitesse assignée
[IEV ref 411-50-16]Тематики
- электротехника, основные понятия
EN
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Nullreaktanz
4 Invers-Reaktanz
реактивное сопротивление обратной последовательности
-EN
negative sequence reactance
the quotient of the reactive fundamental component of negative sequence armature voltage, due to the sinusoidal negative sequence armature current at rated frequency, by the value of that component of current, the machine running at rated speed
[IEV ref 411-50-15]FR
réactance inverse
quotient du terme fondamental de la composante réactive de la tension d'induit inverse, due à la composante inverse du courant d'induit sinusoïdal à fréquence assignée, par la valeur de ce courant, la machine tournant à sa vitesse assignée
[IEV ref 411-50-15]Тематики
- электротехника, основные понятия
EN
- negative phase-sequence reactance
- negative sequence reactance
- subtransient reactance of negative phase
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Invers-Reaktanz
5 Mitreaktanz
реактивное сопротивление прямой последовательности
-EN
positive sequence reactance
the quotient of the reactive fundamental component of the positive sequence armature voltage, due to the sinusoidal positive sequence armature current at rated frequency, by the value of that component of current, the machine running at rated speed
[IEV ref 411-50-14]FR
réactance directe
quotient du terme fondamental de la composante réactive de la tension d'induit directe, due à la composante directe du courant d'induit sinusoïdal à fréquence assignée, par la valeur de ce courant, la machine tournant à sa vitesse assignée
[IEV ref 411-50-14]
Тематики
- электротехника, основные понятия
EN
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Mitreaktanz
См. также в других словарях:
phase — phaseless, adj. phasic, phaseal, adj. /fayz/, n., v., phased, phasing. n. 1. any of the major appearances or aspects in which a thing of varying modes or conditions manifests itself to the eye or mind. 2. a stage in a process of change or… … Universalium
Telomerase RNA component — A 3D representation of part of the telomerase RNA component. This is the solution structure of the P2b P3 pseudoknot from human telomerase RNA.[1] … Wikipedia
Archaeological phase — and phasing refers to the logical reduction of contexts recorded during excavation to near contemporary archaeological horizons that represent a distinct phase of previous land use. These often but not always will be a representation of a former… … Wikipedia
Complement component 3 — PDB rendering based on 1c3d … Wikipedia
Serum amyloid P component — Amyloid P component, serum (SAP) is the identical serum form of amyloid P component (AP), a 25kDa pentameric protein first identified as the pentagonal constituent of in vivo pathological deposits called amyloid .cite journal | author = Cathcart… … Wikipedia
Nuclear localization sequence — A nuclear localization signal or sequence (NLS) is an amino acid sequence which tags a protein for import into the cell nucleus by nuclear transport. Typically, this signal consists of one or more short sequences of positively charged lysines or… … Wikipedia
симметричная составляющая — — [Я.Н.Лугинский, М.С.Фези Жилинская, Ю.С.Кабиров. Англо русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.] Тематики электротехника, основные понятия EN phase sequence component … Справочник технического переводчика
небаланс напряжений — Отличие по модулю значения хотя бы одного из фазных или линейных напряжений многофазной системы электроснабжения от значений напряжений других фаз. [ГОСТ 23875 88] EN voltage unbalance phenomenon due to the differences between voltage deviations… … Справочник технического переводчика
Asymmetric fault — In power engineering, specifically three phase power, an asymmetric or unbalanced fault is a fault which does not affect each of the three phases equally. This is in contrast to a symmetric fault, where each of the phases is affected equally. In… … Wikipedia
electric motor — motor (def. 4). [1885 90] * * * Introduction any of a class of devices that convert electrical energy to mechanical energy, usually by employing electromagnetic phenomena. Most electric motors develop their mechanical torque by the… … Universalium
Symmetrical components — In electrical engineering, the method of Symmetrical components is used to simplify analysis of unbalanced three phase power systems.DescriptionCharles Legeyt Fortescue in a paper presented in 1918 ( Method of Symmetrical Co Ordinates Applied to… … Wikipedia
Перевод: с немецкого на русский
с русского на немецкий- С русского на:
- Немецкий
- С немецкого на:
- Все языки
- Английский
- Русский