  • 1 длительный допустимый ток

    1. Strombelastbarkeit, f
    2. Dauerstrombelastbarkeit, f

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-немецкий словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • Resistance: Fall of Man — European box art Developer(s) Insomniac Games Publisher(s) Sony Computer Entertainment …   Wikipedia

  • Resistance training — has two different, sometimes confused meanings a more broad meaning that refers to any training that uses a resistance to the force of muscular contraction (better termed strength training), and elastic or hydraulic resistance, which refers to a… …   Wikipedia

  • Resistance welding — refers to a group of welding processes that produce coalescence of faying surfaces where heat to form the weld is generated by the resistance of the welding current through the workpieces. Some factors influencing heat or welding temperatures are …   Wikipedia

  • Resistance: Fall of Man — Разработчик Insomniac Games …   Википедия

  • Overall — This article is about bib and brace overalls, shortalls, boilersuits. For the loose above the knee coat like protective garment called an overall in parts of the UK and Ireland, see Smock frock or Lab coat. For other uses, see Overall… …   Wikipedia

  • Disease resistance in fruit and vegetables — There are a number of lines of defence against pests (that is, those animals that cause damage to the plants we grow) and diseases in the organic garden, principal among these being the practice of good husbandry, creating healthy soil and… …   Wikipedia

  • Rolling resistance — Figure 1  Hard wheel rolling on and deforming a soft surface, resulting in the reaction force from the surface having a component that opposes the motion. Rolling resistance, sometimes called rolling friction or rolling drag, is the… …   Wikipedia

  • Danish resistance movement — The Danish resistance movement (Danish: Modstandsbevægelsen) was an underground insurgency movement to resist the German occupation of Denmark during World War II. Due to the unusually lenient terms given to Danish people by the Nazi occupation… …   Wikipedia

  • Low-rolling resistance tires — are tires which are designed to improve fuel efficiency of a car by minimizing the energy wasted as heat as the tire rolls down the road. Approximately 5–15% of the fuel consumed by a typical car may be to overcome to rolling resistance. [… …   Wikipedia

  • German Resistance — The German Resistance refers to those individuals and groups in Nazi Germany who opposed the regime of Adolf Hitler between 1933 and 1945. Some of these engaged in active plans to remove Hitler from power and overthrow his regime. Their plans… …   Wikipedia

  • German resistance — Not to be confused with Werwolf. Memorial plaque to resistance members and wreath at the Bendlerblock, Berlin The German resistance (Widerstand) was the opposition by individuals and groups in Germany to Adolf Hitler or the National Socialist… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»