-
41 PL
1) Общая лексика: Польша, место, множественное число, плюс, ПЛ2) Компьютерная техника: Page Length, Power Loss, Procedural Language, Procedure Library, Program Location3) Медицина: phospholipid, plasma level4) Американизм: Perfect Liberty5) Ботаника: Potato Leaf6) Спорт: Play Live, Premier League, Pro Level7) Военный термин: Personnel Laboratory, Plans, Plans and Operations Division, Propulsion Laboratory, packing list, parts list, patrol land, phase line, pipeline, plain language, platoon leader, position line, post laundry, private line, production list, promotion list, propagation loss, propellant loading, prospective loss, pulse length, рубеж регулирования8) Техника: panel left, party line, pile, pilot lamp, piping load, plug, processing loss, proof line, обозначение станций радиоопределения9) Сельское хозяйство: Psittacosis Lymphogranuloma, plastic limit10) Шутливое выражение: Penny's League11) Математика: Piecewise Linear12) Юридический термин: Pamphlet Law, Partially Limited, Preventive Law, Product Litigation (Department) (Русский язык настолько могуч, что никак не могу перевести на наш великий ;))13) Бухгалтерия: Plan Loan14) Страхование: partial loss, professional liability15) Биржевой термин: parallel loan16) Грубое выражение: Pot Limit17) Кино: Parental Lock18) Оптика: photoluminescence19) Политика: Partido Liberal, Poland20) Сокращение: Poland (NATO country code), Polish, Powered Lift, Propogation Loss, padlock, pitch line, plain, power and lighting, property line, proportional limit, parting line (castings)21) Физика: Planck Length, Proton Loss22) Физиология: Pigmented Lesions23) Электроника: Photo Luminescence, Positive Low, Power Level, Prototype Limit24) Вычислительная техника: Physical Layer (ISO, OSI)25) Нефть: photon, pipe line, proximity log, трубопровод (pipeline)26) Иммунология: Participant Life27) Биохимия: Phospholipids28) Банковское дело: курсовой бюллетень (price list)29) Транспорт: Parking Lot30) Машиностроение: proof load31) Фирменный знак: Penta Labs32) Деловая лексика: Production Line, Project Leader, Public Liability33) Бурение: pressure loss34) Образование: Practical Living35) Таможенная деятельность: прейскурант (price list) (Карачаганак, язык контрактов)36) Инвестиции: price list37) Сетевые технологии: Packet Loss, Print Local, programming language38) Программирование: Program Line39) Сахалин Ю: lube oil40) Химическое оружие: Process line, public law41) Расширение файла: Harvard Graphics Palette, Perl script language source code file, Prolog language source code file, TeX Property List font metric file42) Нефть и газ: low-limit alarm setpoint, Production License (добыча нефти и газа на норвежском континентальном шельфе, обычно употр. вместе с цифрой, напр.: PL 193.)43) Имена и фамилии: Percival Lowell44) NYSE. Protective Life Corporation45) Программное обеспечение: Patch Level, Perl Library, Portable Level46) Библиотечное дело: Public Library -
42 Pl
1) Общая лексика: Польша, место, множественное число, плюс, ПЛ2) Компьютерная техника: Page Length, Power Loss, Procedural Language, Procedure Library, Program Location3) Медицина: phospholipid, plasma level4) Американизм: Perfect Liberty5) Ботаника: Potato Leaf6) Спорт: Play Live, Premier League, Pro Level7) Военный термин: Personnel Laboratory, Plans, Plans and Operations Division, Propulsion Laboratory, packing list, parts list, patrol land, phase line, pipeline, plain language, platoon leader, position line, post laundry, private line, production list, promotion list, propagation loss, propellant loading, prospective loss, pulse length, рубеж регулирования8) Техника: panel left, party line, pile, pilot lamp, piping load, plug, processing loss, proof line, обозначение станций радиоопределения9) Сельское хозяйство: Psittacosis Lymphogranuloma, plastic limit10) Шутливое выражение: Penny's League11) Математика: Piecewise Linear12) Юридический термин: Pamphlet Law, Partially Limited, Preventive Law, Product Litigation (Department) (Русский язык настолько могуч, что никак не могу перевести на наш великий ;))13) Бухгалтерия: Plan Loan14) Страхование: partial loss, professional liability15) Биржевой термин: parallel loan16) Грубое выражение: Pot Limit17) Кино: Parental Lock18) Оптика: photoluminescence19) Политика: Partido Liberal, Poland20) Сокращение: Poland (NATO country code), Polish, Powered Lift, Propogation Loss, padlock, pitch line, plain, power and lighting, property line, proportional limit, parting line (castings)21) Физика: Planck Length, Proton Loss22) Физиология: Pigmented Lesions23) Электроника: Photo Luminescence, Positive Low, Power Level, Prototype Limit24) Вычислительная техника: Physical Layer (ISO, OSI)25) Нефть: photon, pipe line, proximity log, трубопровод (pipeline)26) Иммунология: Participant Life27) Биохимия: Phospholipids28) Банковское дело: курсовой бюллетень (price list)29) Транспорт: Parking Lot30) Машиностроение: proof load31) Фирменный знак: Penta Labs32) Деловая лексика: Production Line, Project Leader, Public Liability33) Бурение: pressure loss34) Образование: Practical Living35) Таможенная деятельность: прейскурант (price list) (Карачаганак, язык контрактов)36) Инвестиции: price list37) Сетевые технологии: Packet Loss, Print Local, programming language38) Программирование: Program Line39) Сахалин Ю: lube oil40) Химическое оружие: Process line, public law41) Расширение файла: Harvard Graphics Palette, Perl script language source code file, Prolog language source code file, TeX Property List font metric file42) Нефть и газ: low-limit alarm setpoint, Production License (добыча нефти и газа на норвежском континентальном шельфе, обычно употр. вместе с цифрой, напр.: PL 193.)43) Имена и фамилии: Percival Lowell44) NYSE. Protective Life Corporation45) Программное обеспечение: Patch Level, Perl Library, Portable Level46) Библиотечное дело: Public Library -
43 pl
1) Общая лексика: Польша, место, множественное число, плюс, ПЛ2) Компьютерная техника: Page Length, Power Loss, Procedural Language, Procedure Library, Program Location3) Медицина: phospholipid, plasma level4) Американизм: Perfect Liberty5) Ботаника: Potato Leaf6) Спорт: Play Live, Premier League, Pro Level7) Военный термин: Personnel Laboratory, Plans, Plans and Operations Division, Propulsion Laboratory, packing list, parts list, patrol land, phase line, pipeline, plain language, platoon leader, position line, post laundry, private line, production list, promotion list, propagation loss, propellant loading, prospective loss, pulse length, рубеж регулирования8) Техника: panel left, party line, pile, pilot lamp, piping load, plug, processing loss, proof line, обозначение станций радиоопределения9) Сельское хозяйство: Psittacosis Lymphogranuloma, plastic limit10) Шутливое выражение: Penny's League11) Математика: Piecewise Linear12) Юридический термин: Pamphlet Law, Partially Limited, Preventive Law, Product Litigation (Department) (Русский язык настолько могуч, что никак не могу перевести на наш великий ;))13) Бухгалтерия: Plan Loan14) Страхование: partial loss, professional liability15) Биржевой термин: parallel loan16) Грубое выражение: Pot Limit17) Кино: Parental Lock18) Оптика: photoluminescence19) Политика: Partido Liberal, Poland20) Сокращение: Poland (NATO country code), Polish, Powered Lift, Propogation Loss, padlock, pitch line, plain, power and lighting, property line, proportional limit, parting line (castings)21) Физика: Planck Length, Proton Loss22) Физиология: Pigmented Lesions23) Электроника: Photo Luminescence, Positive Low, Power Level, Prototype Limit24) Вычислительная техника: Physical Layer (ISO, OSI)25) Нефть: photon, pipe line, proximity log, трубопровод (pipeline)26) Иммунология: Participant Life27) Биохимия: Phospholipids28) Банковское дело: курсовой бюллетень (price list)29) Транспорт: Parking Lot30) Машиностроение: proof load31) Фирменный знак: Penta Labs32) Деловая лексика: Production Line, Project Leader, Public Liability33) Бурение: pressure loss34) Образование: Practical Living35) Таможенная деятельность: прейскурант (price list) (Карачаганак, язык контрактов)36) Инвестиции: price list37) Сетевые технологии: Packet Loss, Print Local, programming language38) Программирование: Program Line39) Сахалин Ю: lube oil40) Химическое оружие: Process line, public law41) Расширение файла: Harvard Graphics Palette, Perl script language source code file, Prolog language source code file, TeX Property List font metric file42) Нефть и газ: low-limit alarm setpoint, Production License (добыча нефти и газа на норвежском континентальном шельфе, обычно употр. вместе с цифрой, напр.: PL 193.)43) Имена и фамилии: Percival Lowell44) NYSE. Protective Life Corporation45) Программное обеспечение: Patch Level, Perl Library, Portable Level46) Библиотечное дело: Public Library -
44 LC
1) Компьютерная техника: Laser Cards, Linux Computer, Location Class, Logic Chain2) Американизм: The Library Of Congress3) Ботаника: Leaf Color4) Спорт: League Cup, Legendary Classic5) Военный термин: Location Code, Logistics Chain, lance corporal, land component, landing craft, late commitment, launch complex, launch control, launch countdown, letter contract, lieutenant colonel, lieutenant commander, life cycle, light car, light case, limited coordination, line of contact, lines of communication, liquid composition, load carrier, local channel, logistic capacity, logistics command, loud and clear6) Техника: in place cited, labor costs, legal counsel, load control, local control, local controller, locked closed, loco citato, logical child, logical circuit, low conductivity, lower control limit7) Сельское хозяйство: Leach Cross8) Шутливое выражение: Little Cat9) Математика: логарифмически выпуклый (log-convex)10) Железнодорожный термин: Lancaster and Chester Railway Company11) Юридический термин: Last Chance, Loose Cannon12) Бухгалтерия: Letter of Credit13) Астрономия: Lyman Continuum14) Грубое выражение: Licks Cock, Love Cat, Luscious Cutie15) Телекоммуникации: Line Chaser, Line Compressed16) Сокращение: Inductance-Capacitance, Laser Collimator, Law Court, Legal Committee, Legislative Council, Lettres et Cartes (international letters and cards), Library of Congress, Lightweight Computer, Limited Capability, Line Charge (explosive system), London Clause, Lord Chamberlain, Lord Chancellor, Saint Lucia, laundry chute, length of chord, line of communication, line-carrying, low carbon, lowercase, lox clean, inductor-Capacitor circuit (as in filters, L is symbol inductance), load-compensating (relay), Last Character, labour costs17) Текстиль: Low Cut18) Электроника: Limit Cycle19) Вычислительная техника: last card, line connector, link circuit, load cell, location counter, Linux Computer (Corel), Loopback Capability (UNI, ATM, OAM)20) Нефть: lead covered, lease crude, long coupling, lost circulation, lost cone, длинномуфтовое соединение для обсадных труб (long coupling), нефть, добытая на данном участке (lease crude), поглощение бурового раствора (loss of circulation), потеря циркуляции (loss of circulation), lifting cost, lifting costs21) Иммунология: Low Cost22) Картография: level crossing23) Банковское дело: аккредитив (letter of credit)24) Транспорт: Landing Certificate, Locational Clearance, Loran C25) Пищевая промышленность: Liquid Concentrate, Lobster Claw, Low Cholesterol26) Фирменный знак: Limited Company, The Learning Center27) Экология: lethal concentration28) СМИ: Left Channel, Less Cable29) Деловая лексика: Lobby Card, аккредитивное письмо, лорд-канцлер (Великобритания, Lord High Chancellor)30) Глоссарий компании Сахалин Энерджи: lead chromate, ЛПВ (lethal concentration), контроллер уровня (level controller), летальная концентрация, летальный порог воздействия (lethal concentration), контролёр уровня (level controller)31) Образование: Listening Comprehension32) Сетевые технологии: List Coverage, Lower Cassette, logical channel, логический канал33) Полимеры: level control34) Программирование: Loop Count, Loop Counter35) Сахалин Р: level controller36) Сахалин Ю: lock closed37) Химическое оружие: liquid chromatography, (50) median lethal concentration, (50) средняя смертельная концентрация, (min) minimum lethal concentration, (min) минимальная смертельная концентрация38) SAP.тех. внутренняя валюта39) Нефть и газ: low pressure condensate40) Электротехника: lead-coated, limit conditions, load center, loss of contact41) Имена и фамилии: Lamb Chop, Leslie Charteris, Lyman Cornelius42) Высокочастотная электроника: inductor/capacitor43) Фармация: label claim44) Должность: Limited Credibility45) Чат: Losing Control46) NYSE. Liberty Corporation of South Carolina47) Программное обеспечение: Label Creator -
45 Lc
1) Компьютерная техника: Laser Cards, Linux Computer, Location Class, Logic Chain2) Американизм: The Library Of Congress3) Ботаника: Leaf Color4) Спорт: League Cup, Legendary Classic5) Военный термин: Location Code, Logistics Chain, lance corporal, land component, landing craft, late commitment, launch complex, launch control, launch countdown, letter contract, lieutenant colonel, lieutenant commander, life cycle, light car, light case, limited coordination, line of contact, lines of communication, liquid composition, load carrier, local channel, logistic capacity, logistics command, loud and clear6) Техника: in place cited, labor costs, legal counsel, load control, local control, local controller, locked closed, loco citato, logical child, logical circuit, low conductivity, lower control limit7) Сельское хозяйство: Leach Cross8) Шутливое выражение: Little Cat9) Математика: логарифмически выпуклый (log-convex)10) Железнодорожный термин: Lancaster and Chester Railway Company11) Юридический термин: Last Chance, Loose Cannon12) Бухгалтерия: Letter of Credit13) Астрономия: Lyman Continuum14) Грубое выражение: Licks Cock, Love Cat, Luscious Cutie15) Телекоммуникации: Line Chaser, Line Compressed16) Сокращение: Inductance-Capacitance, Laser Collimator, Law Court, Legal Committee, Legislative Council, Lettres et Cartes (international letters and cards), Library of Congress, Lightweight Computer, Limited Capability, Line Charge (explosive system), London Clause, Lord Chamberlain, Lord Chancellor, Saint Lucia, laundry chute, length of chord, line of communication, line-carrying, low carbon, lowercase, lox clean, inductor-Capacitor circuit (as in filters, L is symbol inductance), load-compensating (relay), Last Character, labour costs17) Текстиль: Low Cut18) Электроника: Limit Cycle19) Вычислительная техника: last card, line connector, link circuit, load cell, location counter, Linux Computer (Corel), Loopback Capability (UNI, ATM, OAM)20) Нефть: lead covered, lease crude, long coupling, lost circulation, lost cone, длинномуфтовое соединение для обсадных труб (long coupling), нефть, добытая на данном участке (lease crude), поглощение бурового раствора (loss of circulation), потеря циркуляции (loss of circulation), lifting cost, lifting costs21) Иммунология: Low Cost22) Картография: level crossing23) Банковское дело: аккредитив (letter of credit)24) Транспорт: Landing Certificate, Locational Clearance, Loran C25) Пищевая промышленность: Liquid Concentrate, Lobster Claw, Low Cholesterol26) Фирменный знак: Limited Company, The Learning Center27) Экология: lethal concentration28) СМИ: Left Channel, Less Cable29) Деловая лексика: Lobby Card, аккредитивное письмо, лорд-канцлер (Великобритания, Lord High Chancellor)30) Глоссарий компании Сахалин Энерджи: lead chromate, ЛПВ (lethal concentration), контроллер уровня (level controller), летальная концентрация, летальный порог воздействия (lethal concentration), контролёр уровня (level controller)31) Образование: Listening Comprehension32) Сетевые технологии: List Coverage, Lower Cassette, logical channel, логический канал33) Полимеры: level control34) Программирование: Loop Count, Loop Counter35) Сахалин Р: level controller36) Сахалин Ю: lock closed37) Химическое оружие: liquid chromatography, (50) median lethal concentration, (50) средняя смертельная концентрация, (min) minimum lethal concentration, (min) минимальная смертельная концентрация38) SAP.тех. внутренняя валюта39) Нефть и газ: low pressure condensate40) Электротехника: lead-coated, limit conditions, load center, loss of contact41) Имена и фамилии: Lamb Chop, Leslie Charteris, Lyman Cornelius42) Высокочастотная электроника: inductor/capacitor43) Фармация: label claim44) Должность: Limited Credibility45) Чат: Losing Control46) NYSE. Liberty Corporation of South Carolina47) Программное обеспечение: Label Creator -
46 lc
1) Компьютерная техника: Laser Cards, Linux Computer, Location Class, Logic Chain2) Американизм: The Library Of Congress3) Ботаника: Leaf Color4) Спорт: League Cup, Legendary Classic5) Военный термин: Location Code, Logistics Chain, lance corporal, land component, landing craft, late commitment, launch complex, launch control, launch countdown, letter contract, lieutenant colonel, lieutenant commander, life cycle, light car, light case, limited coordination, line of contact, lines of communication, liquid composition, load carrier, local channel, logistic capacity, logistics command, loud and clear6) Техника: in place cited, labor costs, legal counsel, load control, local control, local controller, locked closed, loco citato, logical child, logical circuit, low conductivity, lower control limit7) Сельское хозяйство: Leach Cross8) Шутливое выражение: Little Cat9) Математика: логарифмически выпуклый (log-convex)10) Железнодорожный термин: Lancaster and Chester Railway Company11) Юридический термин: Last Chance, Loose Cannon12) Бухгалтерия: Letter of Credit13) Астрономия: Lyman Continuum14) Грубое выражение: Licks Cock, Love Cat, Luscious Cutie15) Телекоммуникации: Line Chaser, Line Compressed16) Сокращение: Inductance-Capacitance, Laser Collimator, Law Court, Legal Committee, Legislative Council, Lettres et Cartes (international letters and cards), Library of Congress, Lightweight Computer, Limited Capability, Line Charge (explosive system), London Clause, Lord Chamberlain, Lord Chancellor, Saint Lucia, laundry chute, length of chord, line of communication, line-carrying, low carbon, lowercase, lox clean, inductor-Capacitor circuit (as in filters, L is symbol inductance), load-compensating (relay), Last Character, labour costs17) Текстиль: Low Cut18) Электроника: Limit Cycle19) Вычислительная техника: last card, line connector, link circuit, load cell, location counter, Linux Computer (Corel), Loopback Capability (UNI, ATM, OAM)20) Нефть: lead covered, lease crude, long coupling, lost circulation, lost cone, длинномуфтовое соединение для обсадных труб (long coupling), нефть, добытая на данном участке (lease crude), поглощение бурового раствора (loss of circulation), потеря циркуляции (loss of circulation), lifting cost, lifting costs21) Иммунология: Low Cost22) Картография: level crossing23) Банковское дело: аккредитив (letter of credit)24) Транспорт: Landing Certificate, Locational Clearance, Loran C25) Пищевая промышленность: Liquid Concentrate, Lobster Claw, Low Cholesterol26) Фирменный знак: Limited Company, The Learning Center27) Экология: lethal concentration28) СМИ: Left Channel, Less Cable29) Деловая лексика: Lobby Card, аккредитивное письмо, лорд-канцлер (Великобритания, Lord High Chancellor)30) Глоссарий компании Сахалин Энерджи: lead chromate, ЛПВ (lethal concentration), контроллер уровня (level controller), летальная концентрация, летальный порог воздействия (lethal concentration), контролёр уровня (level controller)31) Образование: Listening Comprehension32) Сетевые технологии: List Coverage, Lower Cassette, logical channel, логический канал33) Полимеры: level control34) Программирование: Loop Count, Loop Counter35) Сахалин Р: level controller36) Сахалин Ю: lock closed37) Химическое оружие: liquid chromatography, (50) median lethal concentration, (50) средняя смертельная концентрация, (min) minimum lethal concentration, (min) минимальная смертельная концентрация38) SAP.тех. внутренняя валюта39) Нефть и газ: low pressure condensate40) Электротехника: lead-coated, limit conditions, load center, loss of contact41) Имена и фамилии: Lamb Chop, Leslie Charteris, Lyman Cornelius42) Высокочастотная электроника: inductor/capacitor43) Фармация: label claim44) Должность: Limited Credibility45) Чат: Losing Control46) NYSE. Liberty Corporation of South Carolina47) Программное обеспечение: Label Creator -
47 LS
1) Общая лексика: list of spare parts2) Компьютерная техника: Lacks Software, Language Sensitive, Laser Serial, Laser Servo, Linux Standalone, List For Similar, List Scheduling, List Short, Logic Switch, Login Shell3) Авиация: landing strip4) Медицина: lumbosacral (пояснично-крестцовый)5) Американизм: List Shows6) Военный термин: Labor Service, Land Forces, Southern Europe, Land Sea, Launch Service, Letter Service, London Scottish, Long Shen, Longitudinal Section, landing ship, landing site, laser seeker, laser system, launch simulator, launch site, launch station, launch system, launching silo, lead sheet, level setter, life system, line scan, list of specifications, logistic support, loudspeaker, low speed, launching station, Land System7) Техника: last sent, lighting system, linear smoothing, local synchronization, locked shut, концевой выключатель8) Сельское хозяйство: Light Sussex9) Математика: La Salle, Large Scale, менее значащий (less significant), метод наименьших квадратов, младший (о разряде), наименее значимый (least significant)10) Юридический термин: Law Select11) Страхование: Liner shipping, Summer timber load line12) Астрономия: List Star13) Ветеринария: Lepidopterists' Society14) Грубое выражение: Little Shit15) Оптика: logical sum16) Политика: Liechtenstein17) Телекоммуникации: Link State, Loop Start18) Сокращение: Landing System, Leading Seaman, Lesotho, Letter Signed, Licentiate in Surgery, Liechtenstein (NATO country code), Linnaean Society, launcher site, limestone, Locus Sigilli (place of seal)19) Текстиль: Long Sleeve20) Физиология: Lifespan Setting, Liver And Spleen, Lumbar Spine, Lumbosacral21) Электроника: Limit State22) Вычислительная техника: less significant, load server, LAN Server (IBM)23) Картография: levee station24) Транспорт: Long Stroke25) Фирменный знак: Lone Star26) Экология: lightship station27) Реклама: дальний план28) Деловая лексика: Labor Saving, Lots Standard, Low Shrinkage, место для печати (locus sigilli)29) Глоссарий компании Сахалин Энерджи: load sense (control system)30) Сетевые технологии: Library Server, Licensing System, Link Server, Link Similar, Local Scope, Local Storage, Local System, Luxury Sport31) Полимеры: laminated sheet, left side, level switch, light scattering, low-structure32) Программирование: Level Subroutine, Load Save33) Сахалин А: limit of supply34) Общая лексика: load sensing35) Химическое оружие: Limit switch36) Макаров: lantern slide, lapped seam, long shot, low Schottky, low-power Schottky37) Нефть и газ: Communication Lines, low pressure steam38) Электротехника: line switch, load shedding39) Должность: Land Surveyor40) Чат: Lots Of Stuff, Lucky Sis41) Федеральное бюро расследований: Louisville Field Office42) Единицы измерений: Light Seconds -
48 ls
1) Общая лексика: list of spare parts2) Компьютерная техника: Lacks Software, Language Sensitive, Laser Serial, Laser Servo, Linux Standalone, List For Similar, List Scheduling, List Short, Logic Switch, Login Shell3) Авиация: landing strip4) Медицина: lumbosacral (пояснично-крестцовый)5) Американизм: List Shows6) Военный термин: Labor Service, Land Forces, Southern Europe, Land Sea, Launch Service, Letter Service, London Scottish, Long Shen, Longitudinal Section, landing ship, landing site, laser seeker, laser system, launch simulator, launch site, launch station, launch system, launching silo, lead sheet, level setter, life system, line scan, list of specifications, logistic support, loudspeaker, low speed, launching station, Land System7) Техника: last sent, lighting system, linear smoothing, local synchronization, locked shut, концевой выключатель8) Сельское хозяйство: Light Sussex9) Математика: La Salle, Large Scale, менее значащий (less significant), метод наименьших квадратов, младший (о разряде), наименее значимый (least significant)10) Юридический термин: Law Select11) Страхование: Liner shipping, Summer timber load line12) Астрономия: List Star13) Ветеринария: Lepidopterists' Society14) Грубое выражение: Little Shit15) Оптика: logical sum16) Политика: Liechtenstein17) Телекоммуникации: Link State, Loop Start18) Сокращение: Landing System, Leading Seaman, Lesotho, Letter Signed, Licentiate in Surgery, Liechtenstein (NATO country code), Linnaean Society, launcher site, limestone, Locus Sigilli (place of seal)19) Текстиль: Long Sleeve20) Физиология: Lifespan Setting, Liver And Spleen, Lumbar Spine, Lumbosacral21) Электроника: Limit State22) Вычислительная техника: less significant, load server, LAN Server (IBM)23) Картография: levee station24) Транспорт: Long Stroke25) Фирменный знак: Lone Star26) Экология: lightship station27) Реклама: дальний план28) Деловая лексика: Labor Saving, Lots Standard, Low Shrinkage, место для печати (locus sigilli)29) Глоссарий компании Сахалин Энерджи: load sense (control system)30) Сетевые технологии: Library Server, Licensing System, Link Server, Link Similar, Local Scope, Local Storage, Local System, Luxury Sport31) Полимеры: laminated sheet, left side, level switch, light scattering, low-structure32) Программирование: Level Subroutine, Load Save33) Сахалин А: limit of supply34) Общая лексика: load sensing35) Химическое оружие: Limit switch36) Макаров: lantern slide, lapped seam, long shot, low Schottky, low-power Schottky37) Нефть и газ: Communication Lines, low pressure steam38) Электротехника: line switch, load shedding39) Должность: Land Surveyor40) Чат: Lots Of Stuff, Lucky Sis41) Федеральное бюро расследований: Louisville Field Office42) Единицы измерений: Light Seconds -
49 LI
1) Общая лексика: Landscape Institute2) Компьютерная техника: Line Indent, Line Insertion, Log In3) Американизм: Local Initiative4) Военный термин: LAN Interface, Limited Information, Lithographer, letter of instruction, letter of intent, light infantry, line item (спецификации), logistics instructions, low intensity5) Техника: lease improvement, lettered item, locator, inner6) Сельское хозяйство: liquidity index, loss on ignition7) Железнодорожный термин: Long Island Rail Road Company8) Грубое выражение: Looks Idiotic9) Музыка: Lead In10) Политика: Liberia11) Телекоммуникации: Length Indicator12) Сокращение: Laser Interrogator, Letter of Introduction, Liberia (NATO country code), Liechtenstein, Light Infantry (British Army)13) Физиология: Language Impairment14) Электроника: Laser Interferometry15) Вычислительная техника: live insertion, Lawful Interception (ETSI)16) Нефть: level indicator, индикатор уровня (level indicator), указатель уровня (level indicator)17) Картография: Long Island18) Банковское дело: письмо-обязательство Международному валютному фонду (letter of intent)19) Деловая лексика: Low Innovation20) Бурение: индикатор указатель уровня (level indicator)21) Программирование: L Ist, List Item, List Items, Load Immediate23) Чат: Lost Innocence24) NYSE. Lilly Industries, Inc. -
50 Li
1) Общая лексика: Landscape Institute2) Компьютерная техника: Line Indent, Line Insertion, Log In3) Американизм: Local Initiative4) Военный термин: LAN Interface, Limited Information, Lithographer, letter of instruction, letter of intent, light infantry, line item (спецификации), logistics instructions, low intensity5) Техника: lease improvement, lettered item, locator, inner6) Сельское хозяйство: liquidity index, loss on ignition7) Железнодорожный термин: Long Island Rail Road Company8) Грубое выражение: Looks Idiotic9) Музыка: Lead In10) Политика: Liberia11) Телекоммуникации: Length Indicator12) Сокращение: Laser Interrogator, Letter of Introduction, Liberia (NATO country code), Liechtenstein, Light Infantry (British Army)13) Физиология: Language Impairment14) Электроника: Laser Interferometry15) Вычислительная техника: live insertion, Lawful Interception (ETSI)16) Нефть: level indicator, индикатор уровня (level indicator), указатель уровня (level indicator)17) Картография: Long Island18) Банковское дело: письмо-обязательство Международному валютному фонду (letter of intent)19) Деловая лексика: Low Innovation20) Бурение: индикатор указатель уровня (level indicator)21) Программирование: L Ist, List Item, List Items, Load Immediate23) Чат: Lost Innocence24) NYSE. Lilly Industries, Inc. -
51 li
1) Общая лексика: Landscape Institute2) Компьютерная техника: Line Indent, Line Insertion, Log In3) Американизм: Local Initiative4) Военный термин: LAN Interface, Limited Information, Lithographer, letter of instruction, letter of intent, light infantry, line item (спецификации), logistics instructions, low intensity5) Техника: lease improvement, lettered item, locator, inner6) Сельское хозяйство: liquidity index, loss on ignition7) Железнодорожный термин: Long Island Rail Road Company8) Грубое выражение: Looks Idiotic9) Музыка: Lead In10) Политика: Liberia11) Телекоммуникации: Length Indicator12) Сокращение: Laser Interrogator, Letter of Introduction, Liberia (NATO country code), Liechtenstein, Light Infantry (British Army)13) Физиология: Language Impairment14) Электроника: Laser Interferometry15) Вычислительная техника: live insertion, Lawful Interception (ETSI)16) Нефть: level indicator, индикатор уровня (level indicator), указатель уровня (level indicator)17) Картография: Long Island18) Банковское дело: письмо-обязательство Международному валютному фонду (letter of intent)19) Деловая лексика: Low Innovation20) Бурение: индикатор указатель уровня (level indicator)21) Программирование: L Ist, List Item, List Items, Load Immediate23) Чат: Lost Innocence24) NYSE. Lilly Industries, Inc. -
52 CELP
1) Химия: Code Excited Linear Projection2) Сокращение: Code Exciter Linear Predictive algorithm3) Вычислительная техника: Card Edge Low Profile (Intel; socket), code excited linear prediction, Card Edge Low Profile (socket)4) Химическое оружие: Civilian Employment Level Plan5) Расширение файла: Card Edge Low Profile (socket, Intel)6) НАСДАК: Cellular Products, Inc. -
53 control
1) управление2) регулировка3) контроль•- active sound control
- adaptive picture control
- adaptive sound control
- amplified automatic gain control
- astatic control
- asynchronous control
- attenuator control
- audio-fidelity control
- audio-volume control
- automatic background control
- automatic balance control
- automatic bias control
- automatic brightness control
- automatic chroma control
- automatic chrominance control
- automatic coding control
- automatic color control
- automatic contrast control
- automatic fine tuning control
- automatic frequency control
- automatic gain control
- automatic light control
- automatic modulation control
- automatic overload control
- automatic phase control
- automatic picture control
- automatic power control
- automatic radio station control
- automatic selectivity control
- automatic sensitivity control
- automatic tint control
- automatic volume control
- axle orientation control
- background control
- balance control
- bass control
- black level control
- blue-gain control
- brightness control
- brilliance control
- built-in control
- calls flow control
- camera control
- capstan speed control
- carrier-current control
- centralized control
- chroma control
- chromacity control
- chrominance-gain control
- closed-loop control
- coarse control
- code control
- code-access control
- combined control
- command control
- common control
- communication control
- communications control
- computerized control
- continuity control
- contrast control
- convergence control
- cylinder phase control
- cylinder speed control
- data flow control
- data-link control
- data-recording control
- data-source control
- data-station control
- decentralized control
- delayed automatic gain control
- differential-gain control
- digital automatic gain control
- digital remote control
- direct control
- direct digital control
- direct numerical control
- discrete control
- distance control
- distributed control
- distribution control
- dual control
- dynamic resource control
- echo duration control
- echo return control
- echo tone control
- electronic control
- error control
- external control
- feedback control
- feedforward control
- fine tuning control
- flow control
- focusing control
- format control
- forwarding-execution control
- framing control
- frequency control
- frequency response control
- full logic control
- gain-sensitivity control
- green-gain control
- hardware control
- high-level data link control
- horizontal convergence control
- horizontal parabola control
- hue control
- incoming control
- indicator control
- indirect control
- input/output traffic control
- integrated control
- intensity control
- interference control
- internetwork control
- iris control
- isorhythmic channel access control
- job-processing control
- keyboard control
- keychain remote control
- line-load control
- logical-link control
- long-range control
- loudness control
- low-voltage control
- mail box containing control
- manual control
- master control
- MD/CD changer control
- medium access control
- middle control
- modulation depth control
- multibrand remote control
- mute control
- net control
- noiseless control
- noninteracting control
- nonreversible control
- on-line control
- open-loop control
- phase control
- phase-shift control
- photoelectric control
- photoelectric lighting control
- photoelectric smoke density control
- physical medium control
- point-to-point control
- preventive control
- process control
- programmable remote control
- progressive control
- purity control
- radio control
- reactive control
- Rec Balance control
- Rec Level control
- receiving termination control
- recording balance control
- red-gain control
- relay control
- remote control
- rheostatic control
- ringing control
- saturation control
- selectivity control
- sensor-based control
- separate control
- servo control
- sidetone control
- simple automatic gain control
- single button control
- SMART controls
- snap-acting control
- snap-action automatic gain control
- soft automatic control
- squelch control
- stage control
- static control
- steering wheel-mounted remote control
- step-by-step control
- subscriber's data control
- switching control
- synchronous data link control
- synchronous line control
- tapped control
- temperature control
- thermal electrostatic control
- time-transit automatic gain control
- time-varied gain control
- tone control
- touch-sensitive control
- transmitter gain control
- treble control
- tuning control
- two-mode control
- video operation control
- video-gain control
- voice control
- voice signal quality control
- volume control
- white balance control
- white-level control
- wire break controlEnglish-Russian dictionary of telecommunications and their abbreviations > control
-
54 appareillage
аппаратура распределения и управления
Общий термин для коммутационных аппаратов и их комбинации с относящимися к ним устройствами управления, измерения, защиты и регулирования, а также для узлов, в которых такие аппараты и устройства соединяются с соответствующими фидерами, комплектующим оборудованием, оболочками и опорными конструкциями.
МЭК 60050 (441-11-01) [1].
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
switchgear and controlgear
general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
[IEC 62271-1, ed. 1.0 (2007-10)]FR
appareillage
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu’aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
[IEC 62271-1, ed. 1.0 (2007-10)]Тематики
- аппарат, изделие, устройство...
EN
DE
- Schaltanlagen und/oder Schaltgeräte
FR
низковольтное устройство распределения и управления (НКУ)
Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
[ ГОСТ Р МЭК 61439-1-2012]
низковольтное устройство распределения и управления
Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
Примечания
1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]EN
power switchgear and controlgear assembly (PSC-assembly)
low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
[IEC 61439-2, ed. 1.0 (2009-01)]
low-voltage switchgear and controlgear assembly
combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
[IEC 61892-3, ed. 2.0 (2007-11)]
switchgear and controlgear
a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
[IEV number 441-11-01]
switchgear and controlgear
electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
[IEV number 826-16-03 ]
switchboard
A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
[ McGraw-Hill Dictionary of Architecture & Construction]
switchboard
One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
[ The American Heritage Dictionary of the English Language]FR
ensemble d'appareillage de puissance (ensemble PSC)
ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
[IEC 61439-2, ed. 1.0 (2009-01)]
appareillage, m
matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
[IEV number 826-16-03 ]
appareillage
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
[IEV number 441-11-01]
A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
The types of switchboards, classified by basic features of construction, are as follows:
1. Live-front vertical panels
2. Dead-front boards
3. Safety enclosed boards( metal-clad)
[American electricians’ handbook]
The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.
Its definition, design and installation are based on precise rules; there is no place for improvisation.
The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.
It specifies in particular:
> the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;
> the design and verification rules, constituting a benchmark for product certification.
All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.
Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.
A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.
Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.
What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.
[Schneider Electric]НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.
Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.
Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).
В частности, он определяет:
> распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;
> конструкцию, технические характеристики, виды и методы испытаний НКУ.
В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.
Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.
Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.
Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.
Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.
[Перевод Интент]LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.
The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.
In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.
Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.
The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.
[ABB]Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.
Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам
Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.
Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются
Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Классификация
>>>Действия
Синонимы
Сопутствующие термины
EN
- assembly
- electrical switchboard
- low voltage controlgear and assembly
- low voltage switchboard
- low voltage switchgear and controlgear assembly
- low-voltage switchgear and controlgear assembly
- LV switchgear and controlgear assembly
- LV switchgear assembly
- panel
- power switchgear and controlgear assembly
- PSC-assembly
- switchboard
- switchgear and controlgear
- switchgear/controlgear
DE
- Schaltanlagen und/oder Schaltgeräte
FR
СП
D. Werkstückaufnahmevorrichtung
E. Machine retaining device
F. Appareillage
Приспособление, применяемое на металлорежущем и (или) деревообрабатывающем станке
Источник: ГОСТ 31.010.01-84: Приспособления станочные. Термины и определения оригинал документа
Франко-русский словарь нормативно-технической терминологии > appareillage
-
55 ensemble d'appareillage de puissance
низковольтное устройство распределения и управления (НКУ)
Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
[ ГОСТ Р МЭК 61439-1-2012]
низковольтное устройство распределения и управления
Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
Примечания
1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]EN
power switchgear and controlgear assembly (PSC-assembly)
low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
[IEC 61439-2, ed. 1.0 (2009-01)]
low-voltage switchgear and controlgear assembly
combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
[IEC 61892-3, ed. 2.0 (2007-11)]
switchgear and controlgear
a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
[IEV number 441-11-01]
switchgear and controlgear
electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
[IEV number 826-16-03 ]
switchboard
A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
[ McGraw-Hill Dictionary of Architecture & Construction]
switchboard
One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
[ The American Heritage Dictionary of the English Language]FR
ensemble d'appareillage de puissance (ensemble PSC)
ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
[IEC 61439-2, ed. 1.0 (2009-01)]
appareillage, m
matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
[IEV number 826-16-03 ]
appareillage
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
[IEV number 441-11-01]
A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
The types of switchboards, classified by basic features of construction, are as follows:
1. Live-front vertical panels
2. Dead-front boards
3. Safety enclosed boards( metal-clad)
[American electricians’ handbook]
The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.
Its definition, design and installation are based on precise rules; there is no place for improvisation.
The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.
It specifies in particular:
> the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;
> the design and verification rules, constituting a benchmark for product certification.
All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.
Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.
A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.
Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.
What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.
[Schneider Electric]НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.
Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.
Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).
В частности, он определяет:
> распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;
> конструкцию, технические характеристики, виды и методы испытаний НКУ.
В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.
Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.
Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.
Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.
Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.
[Перевод Интент]LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.
The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.
In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.
Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.
The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.
[ABB]Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.
Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам
Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.
Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются
Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Классификация
>>>Действия
Синонимы
Сопутствующие термины
EN
- assembly
- electrical switchboard
- low voltage controlgear and assembly
- low voltage switchboard
- low voltage switchgear and controlgear assembly
- low-voltage switchgear and controlgear assembly
- LV switchgear and controlgear assembly
- LV switchgear assembly
- panel
- power switchgear and controlgear assembly
- PSC-assembly
- switchboard
- switchgear and controlgear
- switchgear/controlgear
DE
- Schaltanlagen und/oder Schaltgeräte
FR
силовое комплектное устройство распределения и управления
СНКУ
Низковольтное комплектное устройство распределения и управления, применяемое для распределения и управления энергией всех типов нагрузок промышленного, коммерческого и аналогичного назначений, не предназначенное для управления не квалифицированным персоналом.
[ ГОСТ Р МЭК 61439.2-2012]EN
power switchgear and controlgear assembly
PSC-assembly
low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
NOTE It is not excluded for a PSC-assembly to be located in an area accessible to ordinary persons.
[IEC 61439-2, ed. 2.0 (2011-08)]FR
ensemble d'appareillage de puissance
ensemble EAP
ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
NOTE Il n’est pas exclu d’implanter un ensemble EAP dans une zone accessible aux personnes ordinaires.
[IEC 61439-2, ed. 2.0 (2011-08)]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
EN
FR
Франко-русский словарь нормативно-технической терминологии > ensemble d'appareillage de puissance
-
56 ensemble PSC
низковольтное устройство распределения и управления (НКУ)
Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
[ ГОСТ Р МЭК 61439-1-2012]
низковольтное устройство распределения и управления
Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
Примечания
1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]EN
power switchgear and controlgear assembly (PSC-assembly)
low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
[IEC 61439-2, ed. 1.0 (2009-01)]
low-voltage switchgear and controlgear assembly
combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
[IEC 61892-3, ed. 2.0 (2007-11)]
switchgear and controlgear
a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
[IEV number 441-11-01]
switchgear and controlgear
electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
[IEV number 826-16-03 ]
switchboard
A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
[ McGraw-Hill Dictionary of Architecture & Construction]
switchboard
One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
[ The American Heritage Dictionary of the English Language]FR
ensemble d'appareillage de puissance (ensemble PSC)
ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
[IEC 61439-2, ed. 1.0 (2009-01)]
appareillage, m
matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
[IEV number 826-16-03 ]
appareillage
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
[IEV number 441-11-01]
A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
The types of switchboards, classified by basic features of construction, are as follows:
1. Live-front vertical panels
2. Dead-front boards
3. Safety enclosed boards( metal-clad)
[American electricians’ handbook]
The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.
Its definition, design and installation are based on precise rules; there is no place for improvisation.
The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.
It specifies in particular:
> the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;
> the design and verification rules, constituting a benchmark for product certification.
All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.
Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.
A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.
Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.
What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.
[Schneider Electric]НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.
Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.
Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).
В частности, он определяет:
> распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;
> конструкцию, технические характеристики, виды и методы испытаний НКУ.
В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.
Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.
Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.
Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.
Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.
[Перевод Интент]LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.
The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.
In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.
Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.
The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.
[ABB]Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.
Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам
Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.
Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются
Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Классификация
>>>Действия
Синонимы
Сопутствующие термины
EN
- assembly
- electrical switchboard
- low voltage controlgear and assembly
- low voltage switchboard
- low voltage switchgear and controlgear assembly
- low-voltage switchgear and controlgear assembly
- LV switchgear and controlgear assembly
- LV switchgear assembly
- panel
- power switchgear and controlgear assembly
- PSC-assembly
- switchboard
- switchgear and controlgear
- switchgear/controlgear
DE
- Schaltanlagen und/oder Schaltgeräte
FR
Франко-русский словарь нормативно-технической терминологии > ensemble PSC
-
57 Schaltanlagen und/oder Schaltgeräte
аппаратура распределения и управления
Общий термин для коммутационных аппаратов и их комбинации с относящимися к ним устройствами управления, измерения, защиты и регулирования, а также для узлов, в которых такие аппараты и устройства соединяются с соответствующими фидерами, комплектующим оборудованием, оболочками и опорными конструкциями.
МЭК 60050 (441-11-01) [1].
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
switchgear and controlgear
general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
[IEC 62271-1, ed. 1.0 (2007-10)]FR
appareillage
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu’aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
[IEC 62271-1, ed. 1.0 (2007-10)]Тематики
- аппарат, изделие, устройство...
EN
DE
- Schaltanlagen und/oder Schaltgeräte
FR
низковольтное устройство распределения и управления (НКУ)
Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
[ ГОСТ Р МЭК 61439-1-2012]
низковольтное устройство распределения и управления
Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
Примечания
1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]EN
power switchgear and controlgear assembly (PSC-assembly)
low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
[IEC 61439-2, ed. 1.0 (2009-01)]
low-voltage switchgear and controlgear assembly
combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
[IEC 61892-3, ed. 2.0 (2007-11)]
switchgear and controlgear
a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
[IEV number 441-11-01]
switchgear and controlgear
electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
[IEV number 826-16-03 ]
switchboard
A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
[ McGraw-Hill Dictionary of Architecture & Construction]
switchboard
One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
[ The American Heritage Dictionary of the English Language]FR
ensemble d'appareillage de puissance (ensemble PSC)
ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
[IEC 61439-2, ed. 1.0 (2009-01)]
appareillage, m
matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
[IEV number 826-16-03 ]
appareillage
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
[IEV number 441-11-01]
A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
The types of switchboards, classified by basic features of construction, are as follows:
1. Live-front vertical panels
2. Dead-front boards
3. Safety enclosed boards( metal-clad)
[American electricians’ handbook]
The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.
Its definition, design and installation are based on precise rules; there is no place for improvisation.
The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.
It specifies in particular:
> the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;
> the design and verification rules, constituting a benchmark for product certification.
All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.
Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.
A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.
Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.
What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.
[Schneider Electric]НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.
Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.
Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).
В частности, он определяет:
> распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;
> конструкцию, технические характеристики, виды и методы испытаний НКУ.
В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.
Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.
Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.
Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.
Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.
[Перевод Интент]LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.
The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.
In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.
Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.
The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.
[ABB]Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.
Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам
Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.
Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются
Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Классификация
>>>Действия
Синонимы
Сопутствующие термины
EN
- assembly
- electrical switchboard
- low voltage controlgear and assembly
- low voltage switchboard
- low voltage switchgear and controlgear assembly
- low-voltage switchgear and controlgear assembly
- LV switchgear and controlgear assembly
- LV switchgear assembly
- panel
- power switchgear and controlgear assembly
- PSC-assembly
- switchboard
- switchgear and controlgear
- switchgear/controlgear
DE
- Schaltanlagen und/oder Schaltgeräte
FR
Немецко-русский словарь нормативно-технической терминологии > Schaltanlagen und/oder Schaltgeräte
-
58 switchgear and controlgear
- НКУ распределения и управления
- коммутационная аппаратура и аппаратура управления
- аппаратура распределения и управления
аппаратура распределения и управления
Общий термин для коммутационных аппаратов и их комбинации с относящимися к ним устройствами управления, измерения, защиты и регулирования, а также для узлов, в которых такие аппараты и устройства соединяются с соответствующими фидерами, комплектующим оборудованием, оболочками и опорными конструкциями.
МЭК 60050 (441-11-01) [1].
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
switchgear and controlgear
general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
[IEC 62271-1, ed. 1.0 (2007-10)]FR
appareillage
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu’aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
[IEC 62271-1, ed. 1.0 (2007-10)]Тематики
- аппарат, изделие, устройство...
EN
DE
- Schaltanlagen und/oder Schaltgeräte
FR
коммутационная аппаратура и аппаратура управления
Электрическое оборудование, предназначенное для присоединения к электрической цепи с целью выполнения одной или более следующих функций: защиты, управления, разъединения, коммутации.
[ ГОСТ Р МЭК 60050-826-2009]EN
switchgear and controlgear
electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
[IEV number 826-16-03]FR
appareillage, m
matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
[IEV number 826-16-03]Тематики
- аппарат, изделие, устройство...
- электроустановки
EN
DE
- Schaltgerät, n
- Steuergerät, n
FR
- appareillage, m
низковольтное устройство распределения и управления (НКУ)
Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
[ ГОСТ Р МЭК 61439-1-2012]
низковольтное устройство распределения и управления
Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
Примечания
1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]EN
power switchgear and controlgear assembly (PSC-assembly)
low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
[IEC 61439-2, ed. 1.0 (2009-01)]
low-voltage switchgear and controlgear assembly
combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
[IEC 61892-3, ed. 2.0 (2007-11)]
switchgear and controlgear
a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
[IEV number 441-11-01]
switchgear and controlgear
electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
[IEV number 826-16-03 ]
switchboard
A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
[ McGraw-Hill Dictionary of Architecture & Construction]
switchboard
One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
[ The American Heritage Dictionary of the English Language]FR
ensemble d'appareillage de puissance (ensemble PSC)
ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
[IEC 61439-2, ed. 1.0 (2009-01)]
appareillage, m
matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
[IEV number 826-16-03 ]
appareillage
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
[IEV number 441-11-01]
A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
The types of switchboards, classified by basic features of construction, are as follows:
1. Live-front vertical panels
2. Dead-front boards
3. Safety enclosed boards( metal-clad)
[American electricians’ handbook]
The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.
Its definition, design and installation are based on precise rules; there is no place for improvisation.
The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.
It specifies in particular:
> the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;
> the design and verification rules, constituting a benchmark for product certification.
All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.
Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.
A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.
Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.
What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.
[Schneider Electric]НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.
Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.
Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).
В частности, он определяет:
> распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;
> конструкцию, технические характеристики, виды и методы испытаний НКУ.
В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.
Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.
Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.
Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.
Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.
[Перевод Интент]LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.
The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.
In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.
Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.
The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.
[ABB]Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.
Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам
Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.
Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются
Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Классификация
>>>Действия
Синонимы
Сопутствующие термины
EN
- assembly
- electrical switchboard
- low voltage controlgear and assembly
- low voltage switchboard
- low voltage switchgear and controlgear assembly
- low-voltage switchgear and controlgear assembly
- LV switchgear and controlgear assembly
- LV switchgear assembly
- panel
- power switchgear and controlgear assembly
- PSC-assembly
- switchboard
- switchgear and controlgear
- switchgear/controlgear
DE
- Schaltanlagen und/oder Schaltgeräte
FR
Англо-русский словарь нормативно-технической терминологии > switchgear and controlgear
-
59 assembly
- узел оборудования
- сборочная единица
- сборка (монтаж)
- сборка
- подузел
- НКУ распределения и управления
- конструкция
- клеевое соединение
- ассемблирование
ассемблирование
Компиляция программ с языка ассемблера.
[ ГОСТ 19781-90]Тематики
- обеспеч. систем обраб. информ. программное
EN
клеевое соединение
Ндп. клеенное соединение
Соединение частей изделия склеиванием.
[ ГОСТ 28780-90]Недопустимые, нерекомендуемые
Тематики
EN
конструкция
Устройство, взаимное расположение частей и состав машины, механизма или сооружения.
[ http://sl3d.ru/o-slovare.html]Параллельные тексты EN-RU
The new valve profile is design to ensure smooth and precise control at low capacities for improved part load performances.
[Lennox]Вентиль новой конструкции обеспечивает плавное и точное регулирование при низкой производительности холодильного контура, что увеличивает его эффективность при неполной нагрузке.
[Интент]
Тематики
EN
низковольтное устройство распределения и управления (НКУ)
Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
[ ГОСТ Р МЭК 61439-1-2012]
низковольтное устройство распределения и управления
Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
Примечания
1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]EN
power switchgear and controlgear assembly (PSC-assembly)
low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
[IEC 61439-2, ed. 1.0 (2009-01)]
low-voltage switchgear and controlgear assembly
combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
[IEC 61892-3, ed. 2.0 (2007-11)]
switchgear and controlgear
a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
[IEV number 441-11-01]
switchgear and controlgear
electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
[IEV number 826-16-03 ]
switchboard
A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
[ McGraw-Hill Dictionary of Architecture & Construction]
switchboard
One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
[ The American Heritage Dictionary of the English Language]FR
ensemble d'appareillage de puissance (ensemble PSC)
ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
[IEC 61439-2, ed. 1.0 (2009-01)]
appareillage, m
matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
[IEV number 826-16-03 ]
appareillage
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
[IEV number 441-11-01]
A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
The types of switchboards, classified by basic features of construction, are as follows:
1. Live-front vertical panels
2. Dead-front boards
3. Safety enclosed boards( metal-clad)
[American electricians’ handbook]
The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.
Its definition, design and installation are based on precise rules; there is no place for improvisation.
The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.
It specifies in particular:
> the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;
> the design and verification rules, constituting a benchmark for product certification.
All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.
Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.
A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.
Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.
What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.
[Schneider Electric]НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.
Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.
Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).
В частности, он определяет:
> распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;
> конструкцию, технические характеристики, виды и методы испытаний НКУ.
В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.
Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.
Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.
Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.
Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.
[Перевод Интент]LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.
The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.
In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.
Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.
The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.
[ABB]Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.
Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам
Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.
Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются
Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Классификация
>>>Действия
Синонимы
Сопутствующие термины
EN
- assembly
- electrical switchboard
- low voltage controlgear and assembly
- low voltage switchboard
- low voltage switchgear and controlgear assembly
- low-voltage switchgear and controlgear assembly
- LV switchgear and controlgear assembly
- LV switchgear assembly
- panel
- power switchgear and controlgear assembly
- PSC-assembly
- switchboard
- switchgear and controlgear
- switchgear/controlgear
DE
- Schaltanlagen und/oder Schaltgeräte
FR
подузел
узел
сборная деталь
собранный узел
блок
агрегат
—
[ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]Тематики
Синонимы
EN
сборка
Процесс соединения и закрепления элементов и деталей в готовые узлы, монтажные блоки, конструкции или изделия
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]
сборка
Образование соединений составных частей изделия.
Примечания:
1. Примером видов сборки является клепка, сварка заготовок и т.д.
2. Соединение может быть разъемным или неразъемным
[ГОСТ 3.1109-82]Тематики
EN
DE
FR
узел оборудования
компоновочный узел
компоновка
ассемблирование
—
[Л.Г.Суменко. Англо-русский словарь по информационным технологиям. М.: ГП ЦНИИС, 2003.]Тематики
Синонимы
EN
3.2.10 сборочная единица (assembly): Изделие, которое разлагаемо на множество комплектующих или других сборочных единиц с точки зрения конкретного приложения предметной области;
Источник: ГОСТ Р ИСО 10303-1-99: Системы автоматизации производства и их интеграция. Представление данных об изделии и обмен этими данными. Часть 1. Общие представления и основополагающие принципы оригинал документа
3.3.1 конструкция (assembly) предназначена для того, чтобы:
а) удерживать каскетку на голове;
б) поглощать кинетическую энергию, возникающую при ударе, и распределять усилие по поверхности головы.
Примечание - Внутренняя оснастка может состоять из элементов, указанных в 3.3.2 - 3.3.5.
Источник: ГОСТ Р 12.4.245-2007: Система стандартов безопасности труда. Каскетки защитные. Общие технические требования. Методы испытаний оригинал документа
52. Ассемблирование
Assembly
Компиляция программ с языка ассемблера
Источник: ГОСТ 19781-90: Обеспечение систем обработки информации программное. Термины и определения оригинал документа
39. Сборка
D. Fügen
E. Assembly
F. Assemblage
Источник: ГОСТ 3.1109-82: Единая система технологической документации. Термины и определения основных понятий оригинал документа
Англо-русский словарь нормативно-технической терминологии > assembly
-
60 panel
- филенка
- подкомиссия
- плата (с монтажом)
- панель (элемент здания)
- НКУ распределения и управления
- монтажная панель
- заготовка печатной платы
заготовка печатной платы
заготовка
Материал основания печатной платы определенного размера, который подвергается обработке на всех производственных операциях.
[ ГОСТ 20406-75]
заготовка печатной платы
Базовый материал печатной платы определенного размера, подвергаемый обработке в процессе изготовления печатной платы.
[ ГОСТ Р 53386-2009]Тематики
Синонимы
EN
FR
низковольтное устройство распределения и управления (НКУ)
Низковольтные коммутационные аппараты и устройства управления, измерения, сигнализации, защиты, регулирования, собранные совместно, со всеми внутренними электрическими и механическими соединениями и конструктивными элементами.
[ ГОСТ Р МЭК 61439-1-2012]
низковольтное устройство распределения и управления
Комбинация низковольтных коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты, регулирования и т. п., полностью смонтированных изготовителем НКУ (под его ответственность на единой конструктивной основе) со всеми внутренними электрическими и механическими соединениями с соответствующими конструктивными элементами
Примечания
1. В настоящем стандарте сокращение НКУ используют для обозначения низковольтных комплектных устройств распределения и управления.
2. Аппараты, входящие в состав НКУ, могут быть электромеханическими или электронными.
3. По различным причинам, например по условиям транспортирования или изготовления, некоторые операции сборки могут быть выполнены на месте установки, вне предприятия-изготовителя.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]EN
power switchgear and controlgear assembly (PSC-assembly)
low-voltage switchgear and controlgear assembly used to distribute and control energy for all types of loads, intended for industrial, commercial and similar applications where operation by ordinary persons is not intended
[IEC 61439-2, ed. 1.0 (2009-01)]
low-voltage switchgear and controlgear assembly
combination of one or more low-voltage switching devices together with associated control, measuring, signalling, protective, regulation equipment, etc., completely assembled under the responsibility of the manufacturer with all the internal electrical and mechanical interconnections and structural parts.
[IEC 61892-3, ed. 2.0 (2007-11)]
switchgear and controlgear
a general term covering switching devices and their combination with associated control, measuring, protective and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures and supporting structures
[IEV number 441-11-01]
switchgear and controlgear
electric equipment intended to be connected to an electric circuit for the purpose of carrying out one or more of the following functions: protection, control, isolation, switching
NOTE – The French and English terms can be considered as equivalent in most cases. However, the French term has a broader meaning than the English term and includes for example connecting devices, plugs and socket-outlets, etc. In English, these latter devices are known as accessories.
[IEV number 826-16-03 ]
switchboard
A large single electric control panel, frame, or assembly of panels on which are mounted (either on the back or on the face, or both) switches, overcurrent and other protective devices, buses, and usually instruments; not intended for installation in a cabinet but may be completely enclosed in metal; usually is accessible from both the front and rear.
[ McGraw-Hill Dictionary of Architecture & Construction]
switchboard
One or more panels accommodating control switches, indicators, and other apparatus for operating electric circuits
[ The American Heritage Dictionary of the English Language]FR
ensemble d'appareillage de puissance (ensemble PSC)
ensemble d'appareillage à basse tension utilisé pour répartir et commander l'énergie pour tous les types de charges et prévu pour des applications industrielles, commerciales et analogues dans lesquelles l'exploitation par des personnes ordinaires n'est pas prévue
[IEC 61439-2, ed. 1.0 (2009-01)]
appareillage, m
matériel électrique destiné à être relié à un circuit électrique en vue d'assurer une ou plusieurs des fonctions suivantes: protection, commande, sectionnement, connexion
NOTE – Les termes français et anglais peuvent être considérés comme équivalents dans la plupart des cas. Toutefois, le terme français couvre un domaine plus étendu que le terme anglais, et comprend notamment les dispositifs de connexion, les prises de courant, etc. En anglais, ces derniers sont dénommés "accessories".
[IEV number 826-16-03 ]
appareillage
terme général applicable aux appareils de connexion et à leur combinaison avec des appareils de commande, de mesure, de protection et de réglage qui leur sont associés, ainsi qu'aux ensembles de tels appareils avec les connexions, les accessoires, les enveloppes et les charpentes correspondantes
[IEV number 441-11-01]
A switchboard as defined in the National Electrical Code is a large single panel, frame, or assembly of panels on which are mounted, on the face or back or both switches, overcurrent and other protective devices, buses, and, usually, instruments.
Switchboards are generally accessible from the rear as well as from the front and are not intended to be installed in cabinets.
The types of switchboards, classified by basic features of construction, are as follows:
1. Live-front vertical panels
2. Dead-front boards
3. Safety enclosed boards( metal-clad)
[American electricians’ handbook]
The switchboard plays an essential role in the availability of electric power, while meeting the needs of personal and property safety.
Its definition, design and installation are based on precise rules; there is no place for improvisation.
The IEC 61439 standard aims to better define " low-voltage switchgear and controlgear assemblies", ensuring that the specified performances are reached.
It specifies in particular:
> the responsibilities of each player, distinguishing those of the original equipment manufacturer - the organization that performed the original design and associated verification of an assembly in accordance with the standard, and of the assembly manufacturer - the organization taking responsibility for the finished assembly;
> the design and verification rules, constituting a benchmark for product certification.
All the component parts of the electrical switchboard are concerned by the IEC 61439 standard.
Equipment produced in accordance with the requirements of this switchboard standard ensures the safety and reliability of the installation.
A switchboard must comply with the requirements of standard IEC 61439-1 and 2 to guarantee the safety and reliability of the installation.
Managers of installations, fully aware of the professional and legal liabilities weighing on their company and on themselves, demand a high level of safety for the electrical installation.
What is more, the serious economic consequences of prolonged halts in production mean that the electrical switchboard must provide excellent continuity of service, whatever the operating conditions.
[Schneider Electric]НКУ играет главную роль в обеспечении электроэнергией, удовлетворяя при этом всем требованиям по безопасности людей и сохранности имущества.
Выбор конструкции, проектирование и монтаж основаны на чётких правилах, не допускающих никакой импровизации.
Требования к низковольтным комплектным устройствам распределения и управления сформулированы в стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000).
В частности, он определяет:
> распределение ответственности между изготовителем НКУ - организацией, разработавшей конструкцию НКУ и проверившей его на соответствие требованиям стандарта, и сборщиком – организацией, выполнившей сборку НКУ;
> конструкцию, технические характеристики, виды и методы испытаний НКУ.
В стандарте МЭК 61439 (ГОСТ Р 51321. 1-2000) описываются все компоненты НКУ.
Оборудование, изготовленное в соответствии с требованиями этого стандарта, обеспечивает безопасность и надежность электроустановки.
Для того чтобы гарантировать безопасность эксплуатации и надежность работы электроустановки, распределительный щит должен соответствовать требованиям стандарта МЭК 61439-1 и 2.
Лица, ответственные за электроустановки, должны быть полностью осведомлены о профессиональной и юридической ответственности, возложенной на их компанию и на них лично, за обеспечение высокого уровня безопасности эксплуатации этих электроустановок.
Кроме того, поскольку длительные перерывы производства приводят к серьезным экономическим последствиям, электрический распределительный щит должен обеспечивать надежную и бесперебойную работу независимо от условий эксплуатации.
[Перевод Интент]LV switchgear assemblies are undoubtedly the components of the electric installation more subject to the direct intervention of personnel (operations, maintenance, etc.) and for this reason users demand from them higher and higher safety requirements.
The compliance of an assembly with the state of the art and therefore, presumptively, with the relevant technical Standard, cannot be based only on the fact that the components which constitute it comply with the state of the art and therefore, at least presumptively, with the relevant technical standards.
In other words, the whole assembly must be designed, built and tested in compliance with the state of the art.
Since the assemblies under consideration are low voltage equipment, their rated voltage shall not exceed 1000 Va.c. or 1500 Vd.c. As regards currents, neither upper nor lower limits are provided in the application field of this Standard.
The Standard IEC 60439-1 states the construction, safety and maintenance requirements for low voltage switchgear and controlgear assemblies, without dealing with the functional aspects which remain a competence of the designer of the plant for which the assembly is intended.
[ABB]Низковольтные комплектные устройства (НКУ), вне всякого сомнения, являются частями электроустановок, которые наиболее подвержены непосредственному вмешательству оперативного, обслуживающего и т. п. персонала. Вот почему требования потребителей к безопасности НКУ становятся все выше и выше.
Соответствие НКУ современному положению дел и вследствие этого, гипотетически, соответствующим техническим стандартам, не может основываться только на том факте, что составляющие НКУ компоненты соответствуют современному состоянию дел и поэтому, по крайней мере, гипотетически, - соответствующим техническим стандартам
Другими словами, НКУ должно быть разработано, изготовлено и испытано в соответствии с современными требованиями.
Мы рассматриваем низковольтные комплектные устройства и это означает, что их номинальное напряжение не превышает 1000 В переменного тока или 1500 В постоянного тока. Что касается тока, то ни верхнее, ни нижнее значение стандартами, относящимися к данной области, не оговариваются
Стандарт МЭК 60439-1 устанавливает требования к конструкции, безопасности и техническому обслуживанию низковольтных комплектных устройств без учета их функций, полагая, что функции НКУ являются компетенцией проектировщиков электроустановки, частью которых эти НКУ являются.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Классификация
>>>Действия
Синонимы
Сопутствующие термины
EN
- assembly
- electrical switchboard
- low voltage controlgear and assembly
- low voltage switchboard
- low voltage switchgear and controlgear assembly
- low-voltage switchgear and controlgear assembly
- LV switchgear and controlgear assembly
- LV switchgear assembly
- panel
- power switchgear and controlgear assembly
- PSC-assembly
- switchboard
- switchgear and controlgear
- switchgear/controlgear
DE
- Schaltanlagen und/oder Schaltgeräte
FR
панель
Крупный элемент сборных конструкций в виде пластинки, размеры которого соответствуют основным объёмно-планировочным членениям сооружения
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]Тематики
EN
DE
FR
плата (с монтажом)
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
подкомиссия
группа экспертов
специальный комитет (комиссия)
—
[ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]Тематики
Синонимы
EN
филенка
Выделенный тонкими профилированными рамками участок, щиток из тонких досок, фанеры или пластика, закрывающий просвет в каркасе полотна двери
[ http://na-dveri.ru/polezno-znati/termini-i-opredeleniya.html]Тематики
EN
монтажная панель
Панель, служащая для размещения комплектующих элементов и предназначенная для установки в НКУ.
Примечание - Если этот конструктивный элемент содержит аппаратуру, то он может рассматриваться как отдельное самостоятельное НКУ.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]
монтажная панель
Панель, предназначенная для размещения комплектующих элементов, устанавливаемая в НКУ
[ ГОСТ Р МЭК 61439.1-2013]
монтажная панель
Отдельный внутренний комплектующий элемент оболочки, предназначенный для установки и крепления на нем аппаратуры распределения и управления.
[ ГОСТ Р 52796- 2007( МЭК 62208: 2002)]EN
mounting plate
separate internal accessory of the enclosure intended for the mounting of electrical components
[IEC 62208, ed. 1.0 (2002-11)]FR
platine
élément interne séparé de l'enveloppe destiné au montage de l'appareillage
[IEC 62208, ed. 1.0 (2002-11)]

Установка неперфорированной монтажной панели в оболочку шкафа
Неразборная сварная оболочка ящика с установленной перфорированной оцинкованной монтажной панелью
На предприятии, выполняющем электромонтаж НКУ, монтажную панель обычно извлекают из оболочки, выполняют электромонтаж, а затем монтажную панель с установленными аппаратами и выполненным электромонтажом вставляют в оболочку.
[Интент]
Недопустимые, нерекомендуемые
Тематики
- НКУ (шкафы, пульты,...)
Обобщающие термины
EN
FR
Англо-русский словарь нормативно-технической терминологии > panel
См. также в других словарях:
low-level — UK US adjective ► WORKPLACE used to describe someone who does not have an important job or much influence in an organization: »He was a low level employee with no knowledge of the big decisions. ► ENVIRONMENT low level waste is not very dangerous … Financial and business terms
Low Level Virtual Machine — Développeur LLVM Developer Group, Université de l Illinois Dernière version … Wikipédia en Français
low-level — adjective * 1. ) a low level language is a MACHINE CODE used for writing computer programs 2. ) without much importance, power, or difficulty: Both sides sent low level delegations to the talks. low level activities which could be done without… … Usage of the words and phrases in modern English
low-level language — noun A computer programming language using easily remembered words or letters, each instruction translating into one machine code instruction (cf ↑high level language) • • • Main Entry: ↑low … Useful english dictionary
low-level — ► ADJECTIVE 1) of relatively little importance. 2) Computing denoting a programming language that is close to machine code in form … English terms dictionary
Low-level programming language — In computer science, a low level programming language is a language that provides little or no abstraction from a computer s microprocessor. The word low refers to the small or nonexistent amount of abstraction between the language and machine… … Wikipedia
low-level */ — UK / US adjective 1) without much importance, power, or difficulty Both sides sent low level delegations to the talks. low level activities which could be done without supervision 2) computing a low level language is a machine code used for… … English dictionary
Low Level Virtual Machine — The LLVM Compiler Infrastructure Maintainer Chris Lattner[1] Entwickler The LLVM Team[2] Aktuelle Version 2.9 (6. April 2011) … Deutsch Wikipedia
Low Level Virtual Machine — LLVM Тип Компилятор Разработчик LLVM Developer Group Н … Википедия
Low Level Virtual Machine — infobox software name = LLVM developer = LLVM Developer Group Apple, Inc latest release version = 2.3 latest release date = 9 June 2008 released = 2000 operating system = Cross platform genre = Compiler license = University of Illinois/NCSA Open… … Wikipedia
Low-level document — In Fagan Inspection the low level document is the document (or program code/design etc) which is to be inspected on the basis of the High level document … Wikipedia