-
1 gorge efficace(soudures d'angle)
эффективная толщина шва
Размер, который определяет передачу нагрузки и зависит от формы и глубины проплавления шва.
[ ГОСТ Р ИСО 17659-2009] [ISO 17659:2002]EN
effective throat thickness
Dimension that is responsible for carrying the load, dependent on the shape and penetration of the weld.
[ ГОСТ Р ИСО 17659-2009] [ISO 17659:2002]FR
gorge efficace(soudures d'angle)
épaisseur efficace (soudures bout а bout)
Dimension qui transmet l'effort et qui dépend de la forme géométrique et de la pénétration de la soudure.
[ ГОСТ Р ИСО 17659-2009] [ISO 17659:2002]Тематики
- сварка, резка, пайка
EN
FR
Франко-русский словарь нормативно-технической терминологии > gorge efficace(soudures d'angle)
-
2 épaisseur efficace (soudures bout а bout)
эффективная толщина шва
Размер, который определяет передачу нагрузки и зависит от формы и глубины проплавления шва.
[ ГОСТ Р ИСО 17659-2009] [ISO 17659:2002]EN
effective throat thickness
Dimension that is responsible for carrying the load, dependent on the shape and penetration of the weld.
[ ГОСТ Р ИСО 17659-2009] [ISO 17659:2002]FR
gorge efficace(soudures d'angle)
épaisseur efficace (soudures bout а bout)
Dimension qui transmet l'effort et qui dépend de la forme géométrique et de la pénétration de la soudure.
[ ГОСТ Р ИСО 17659-2009] [ISO 17659:2002]Тематики
- сварка, резка, пайка
EN
FR
Франко-русский словарь нормативно-технической терминологии > épaisseur efficace (soudures bout а bout)
-
3 charge non linéaire
нелинейная нагрузка
Нагрузка, в которой ток и напряжение связаны между собой нелинейным законом.EN
non-linear load
load where the parameter Z (load impedance) is no longer a constant but is a variable dependent on other parameters, such as voltage or time
[IEC 62310-3, ed. 1.0 (2008-06)]FR
charge non linéaire
charge où le paramètre Z (impédance de charge) n’est plus une constante mais une variable dépendant d’autres paramètres, comme la tension ou le temps
[IEC 62310-3, ed. 1.0 (2008-06)]
На рисунке показаны осциллограммы напряжения и тока, протекающего через импульсный источник питания компьютера. Видно, что при синусоидальном питающем напряжении форма кривой потребляемого тока существенно отличается от синусоидальной (т. е. зависимость тока от напряжения является нелинейной).
Компьютер - типичный пример нелинейной нагрузки.Тематики
- электроснабжение в целом
- электротехника, основные понятия
Классификация
>>>EN
FR
Франко-русский словарь нормативно-технической терминологии > charge non linéaire
См. также в других словарях:
Load profile — In electrical engineering, a load profile is a graph of the variation in the electrical load versus time. A load profile will vary according to customer type (typical examples include residential, commercial and industrial), temperature and… … Wikipedia
load — 1. A departure from normal body content, as of water, salt, or heat; positive loads are quantities in excess of the normal; negative loads are quantities in deficit. 2. The quantity of a measurable … Medical dictionary
load classification number — A system of classification of the supporting capacity of pavements, indicating their ability to support loads without cracking or becoming permanently deformed. The number is obtained by making plate bearing tests on the pavement. Likewise, the… … Aviation dictionary
Stream load — is a geologic term referring to the solid matter carried by a stream (Strahler and Strahler, 2006). Erosion continually removes mineral material from the bed and banks of the stream channel, adding this material to the regular flow of water. The… … Wikipedia
Extract, transform, load — Extract, transform and load (ETL) is a process in database usage and especially in data warehousing that involves: Extracting data from outside sources Transforming it to fit operational needs (which can include quality levels) Loading it into… … Wikipedia
Genetic load — In population genetics, genetic load or genetic burden is a measure of the cost of lost alleles due to selection (selectional load) or mutation (mutational load). It is a value in the range 0 < L < 1, where 0 represents no load. The concept … Wikipedia
Functional load — In linguistics and especially phonology, functional load refers to the importance of certain features in making distinctions in a language. English vowels, for example, have a very high functional load: There are innumerable sets of words… … Wikipedia
prescribed nuclear load — A specified quantity of nuclear weapons to be carried by a delivery unit. The establishment and replenishment of this load after each expenditure is a command decision and is dependent upon the tactical situation, the nuclear logistical situation … Military dictionary
Class-D amplifier — Block diagram of a basic switching or PWM (class D) amplifier A class D amplifier or switching amplifier is an electronic amplifier where all power devices (usually MOSFETs) are operated as binary switches. They are either fully on or fully… … Wikipedia
Osteoporosis — Classification and external resources A stooped back is often the result of osteoporosis. ICD 10 M … Wikipedia
Charge pump — 2 stage charge pump with DC voltage supply and a pump control signal S0 A charge pump is a kind of DC to DC converter that uses capacitors as energy storage elements to create either a higher or lower voltage power source. Charge pump circuits… … Wikipedia