-
1 mean energy availability factor
средний коэффициент полезного действия; средний кпдEnglish-Russian dictionary on nuclear energy > mean energy availability factor
-
2 energy compensation
компенсация реактивной мощности
-EN
reactive power compensation
an action to optimize the transmission of reactive power in the network as a whole
[МЭС 603-04-28]FR
compensation de l'énergie réactive
action dont le but est d'optimiser globalement le transport d'énergie réactive dans le réseau
[МЭС 603-04-28]Параллельные тексты EN-RU
Reactive energy management
In electrical networks, reactive energy results in increased line currents for a given active energy transmitted to loads.
The main consequences are:
• Need for oversizing of transmission and distribution networks by utilities,
• Increased voltage drops and sags along the distribution lines,
• Additional power losses.
This results in increased electricity bills for industrial customers because of:• Penalties applied by most utilities on reactive energy,
• Increased overall kVA demand,
• Increased energy consumption within the installations.
Reactive energy management aims to optimize your electrical installation by reducing energy consumption, and to improve power availability.
Total CO2 emissions are also reduced.
Utility power bills are typically reduced by 5 % to 10 %.
[Schneider Electric]Компенсация реактивной мощности
Передача по электрической сети реактивной энергии приводит к увеличению линейных токов (по сравнению токами, протекающими при передаче нагрузкам только активной энергии).
Основные последствия этого явления:
● необходимость увеличения сечения проводников в сетях передачи и распределения электроэнергии;
● повышенное падение и провалы напряжения в распределительных линиях;
● дополнительные потери электроэнергии;
Для промышленных потребителей такие потери приводят к возрастанию расходов на оплату электроэнергии, что вызвано:● штрафами, накладываемыми поставщиками электроэнергии за избыточную реактивную мощность;
● увеличением потребления полной мощности (измеряемой в кВА);
● повышенным энергопотреблением электроустановок.Цель компенсации реактивной мощности (КРМ) – оптимизация работы электроустановки за счет сокращения потребления энергии и увеличения надежности электроснабжения. Кроме того, КРМ позволяет уменьшить выбросы CO2 и сократить расходы на электроэнергию в среднем на 5-10 %.
[Перевод Интент]Наиболее эффективным способом снижения потребляемой из сети реактивной мощности является применение установок компенсации реактивной мощности (конденсаторных установок).
Использование конденсаторных установок позволяет:- разгрузить питающие линии электропередачи, трансформаторы и распределительные устройства;
- снизить расходы на оплату электроэнергии;
- при использовании определенного типа установок снизить уровень высших гармоник;
- подавить сетевые помехи, снизить несимметрию фаз;
- увеличить надежность и экономичность распределительных сетей.
На практике коэффициент мощности после компенсации находится в пределах от 0,93 до 0,99.
Наибольший экономический эффект достигается при размещении компенсирующих устройств вблизи электроприемников, потребляющих реактивную мощность.
Различают следующие виды компенсации:-
индивидуальная (нерегулируемая) компенсация
Целесообразна, если мощность электроприемника больше 20 кВт и потребляемая мощность постоянна в течение длительного времени.
Компенсирующая нерегулируемая установка подключается непосредственно у потребителя. Как правило, применяется для компенсации реактивной мощности таких потребителей, как мощные компрессоры, вентиляторы и насосы, силовые трансформаторы. - групповая (нерегулируемая) компенсация
- централизованная компенсация
Для ламп типа ДРЛ, ДРИ, ДРИЗ, ДНаТ может применяться как групповая, так и индивидуальная компенсация реактивной мощности
[ПУЭ]Тематики
Синонимы
Сопутствующие термины
- конденсатор компенсации реактивной мощности
- конденсаторная батарея компенсации реактивной мощности
- контроллер компенсации реактивной мощности
- недостаточная компенсация реактивной мощности
- перекомпенсация реактивной мощности
- потребляемая реактивная мощность
- ступень компенсации реактивной мощности
- установка КРМ
- устройства динамической компенсации реактивной мощности
EN
- energy compensation
- management of reactive energy
- power factor compensation
- reactive energy management
- reactive power compensation
DE
FR
Англо-русский словарь нормативно-технической терминологии > energy compensation
-
3 power factor compensation
компенсация коэффициента мощности
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
компенсация реактивной мощности
-EN
reactive power compensation
an action to optimize the transmission of reactive power in the network as a whole
[МЭС 603-04-28]FR
compensation de l'énergie réactive
action dont le but est d'optimiser globalement le transport d'énergie réactive dans le réseau
[МЭС 603-04-28]Параллельные тексты EN-RU
Reactive energy management
In electrical networks, reactive energy results in increased line currents for a given active energy transmitted to loads.
The main consequences are:
• Need for oversizing of transmission and distribution networks by utilities,
• Increased voltage drops and sags along the distribution lines,
• Additional power losses.
This results in increased electricity bills for industrial customers because of:• Penalties applied by most utilities on reactive energy,
• Increased overall kVA demand,
• Increased energy consumption within the installations.
Reactive energy management aims to optimize your electrical installation by reducing energy consumption, and to improve power availability.
Total CO2 emissions are also reduced.
Utility power bills are typically reduced by 5 % to 10 %.
[Schneider Electric]Компенсация реактивной мощности
Передача по электрической сети реактивной энергии приводит к увеличению линейных токов (по сравнению токами, протекающими при передаче нагрузкам только активной энергии).
Основные последствия этого явления:
● необходимость увеличения сечения проводников в сетях передачи и распределения электроэнергии;
● повышенное падение и провалы напряжения в распределительных линиях;
● дополнительные потери электроэнергии;
Для промышленных потребителей такие потери приводят к возрастанию расходов на оплату электроэнергии, что вызвано:● штрафами, накладываемыми поставщиками электроэнергии за избыточную реактивную мощность;
● увеличением потребления полной мощности (измеряемой в кВА);
● повышенным энергопотреблением электроустановок.Цель компенсации реактивной мощности (КРМ) – оптимизация работы электроустановки за счет сокращения потребления энергии и увеличения надежности электроснабжения. Кроме того, КРМ позволяет уменьшить выбросы CO2 и сократить расходы на электроэнергию в среднем на 5-10 %.
[Перевод Интент]Наиболее эффективным способом снижения потребляемой из сети реактивной мощности является применение установок компенсации реактивной мощности (конденсаторных установок).
Использование конденсаторных установок позволяет:- разгрузить питающие линии электропередачи, трансформаторы и распределительные устройства;
- снизить расходы на оплату электроэнергии;
- при использовании определенного типа установок снизить уровень высших гармоник;
- подавить сетевые помехи, снизить несимметрию фаз;
- увеличить надежность и экономичность распределительных сетей.
На практике коэффициент мощности после компенсации находится в пределах от 0,93 до 0,99.
Наибольший экономический эффект достигается при размещении компенсирующих устройств вблизи электроприемников, потребляющих реактивную мощность.
Различают следующие виды компенсации:-
индивидуальная (нерегулируемая) компенсация
Целесообразна, если мощность электроприемника больше 20 кВт и потребляемая мощность постоянна в течение длительного времени.
Компенсирующая нерегулируемая установка подключается непосредственно у потребителя. Как правило, применяется для компенсации реактивной мощности таких потребителей, как мощные компрессоры, вентиляторы и насосы, силовые трансформаторы. - групповая (нерегулируемая) компенсация
- централизованная компенсация
Для ламп типа ДРЛ, ДРИ, ДРИЗ, ДНаТ может применяться как групповая, так и индивидуальная компенсация реактивной мощности
[ПУЭ]Тематики
Синонимы
Сопутствующие термины
- конденсатор компенсации реактивной мощности
- конденсаторная батарея компенсации реактивной мощности
- контроллер компенсации реактивной мощности
- недостаточная компенсация реактивной мощности
- перекомпенсация реактивной мощности
- потребляемая реактивная мощность
- ступень компенсации реактивной мощности
- установка КРМ
- устройства динамической компенсации реактивной мощности
EN
- energy compensation
- management of reactive energy
- power factor compensation
- reactive energy management
- reactive power compensation
DE
FR
Англо-русский словарь нормативно-технической терминологии > power factor compensation
-
4 management of reactive energy
компенсация реактивной мощности
-EN
reactive power compensation
an action to optimize the transmission of reactive power in the network as a whole
[МЭС 603-04-28]FR
compensation de l'énergie réactive
action dont le but est d'optimiser globalement le transport d'énergie réactive dans le réseau
[МЭС 603-04-28]Параллельные тексты EN-RU
Reactive energy management
In electrical networks, reactive energy results in increased line currents for a given active energy transmitted to loads.
The main consequences are:
• Need for oversizing of transmission and distribution networks by utilities,
• Increased voltage drops and sags along the distribution lines,
• Additional power losses.
This results in increased electricity bills for industrial customers because of:• Penalties applied by most utilities on reactive energy,
• Increased overall kVA demand,
• Increased energy consumption within the installations.
Reactive energy management aims to optimize your electrical installation by reducing energy consumption, and to improve power availability.
Total CO2 emissions are also reduced.
Utility power bills are typically reduced by 5 % to 10 %.
[Schneider Electric]Компенсация реактивной мощности
Передача по электрической сети реактивной энергии приводит к увеличению линейных токов (по сравнению токами, протекающими при передаче нагрузкам только активной энергии).
Основные последствия этого явления:
● необходимость увеличения сечения проводников в сетях передачи и распределения электроэнергии;
● повышенное падение и провалы напряжения в распределительных линиях;
● дополнительные потери электроэнергии;
Для промышленных потребителей такие потери приводят к возрастанию расходов на оплату электроэнергии, что вызвано:● штрафами, накладываемыми поставщиками электроэнергии за избыточную реактивную мощность;
● увеличением потребления полной мощности (измеряемой в кВА);
● повышенным энергопотреблением электроустановок.Цель компенсации реактивной мощности (КРМ) – оптимизация работы электроустановки за счет сокращения потребления энергии и увеличения надежности электроснабжения. Кроме того, КРМ позволяет уменьшить выбросы CO2 и сократить расходы на электроэнергию в среднем на 5-10 %.
[Перевод Интент]Наиболее эффективным способом снижения потребляемой из сети реактивной мощности является применение установок компенсации реактивной мощности (конденсаторных установок).
Использование конденсаторных установок позволяет:- разгрузить питающие линии электропередачи, трансформаторы и распределительные устройства;
- снизить расходы на оплату электроэнергии;
- при использовании определенного типа установок снизить уровень высших гармоник;
- подавить сетевые помехи, снизить несимметрию фаз;
- увеличить надежность и экономичность распределительных сетей.
На практике коэффициент мощности после компенсации находится в пределах от 0,93 до 0,99.
Наибольший экономический эффект достигается при размещении компенсирующих устройств вблизи электроприемников, потребляющих реактивную мощность.
Различают следующие виды компенсации:-
индивидуальная (нерегулируемая) компенсация
Целесообразна, если мощность электроприемника больше 20 кВт и потребляемая мощность постоянна в течение длительного времени.
Компенсирующая нерегулируемая установка подключается непосредственно у потребителя. Как правило, применяется для компенсации реактивной мощности таких потребителей, как мощные компрессоры, вентиляторы и насосы, силовые трансформаторы. - групповая (нерегулируемая) компенсация
- централизованная компенсация
Для ламп типа ДРЛ, ДРИ, ДРИЗ, ДНаТ может применяться как групповая, так и индивидуальная компенсация реактивной мощности
[ПУЭ]Тематики
Синонимы
Сопутствующие термины
- конденсатор компенсации реактивной мощности
- конденсаторная батарея компенсации реактивной мощности
- контроллер компенсации реактивной мощности
- недостаточная компенсация реактивной мощности
- перекомпенсация реактивной мощности
- потребляемая реактивная мощность
- ступень компенсации реактивной мощности
- установка КРМ
- устройства динамической компенсации реактивной мощности
EN
- energy compensation
- management of reactive energy
- power factor compensation
- reactive energy management
- reactive power compensation
DE
FR
Англо-русский словарь нормативно-технической терминологии > management of reactive energy
-
5 reactive energy management
компенсация реактивной мощности
-EN
reactive power compensation
an action to optimize the transmission of reactive power in the network as a whole
[МЭС 603-04-28]FR
compensation de l'énergie réactive
action dont le but est d'optimiser globalement le transport d'énergie réactive dans le réseau
[МЭС 603-04-28]Параллельные тексты EN-RU
Reactive energy management
In electrical networks, reactive energy results in increased line currents for a given active energy transmitted to loads.
The main consequences are:
• Need for oversizing of transmission and distribution networks by utilities,
• Increased voltage drops and sags along the distribution lines,
• Additional power losses.
This results in increased electricity bills for industrial customers because of:• Penalties applied by most utilities on reactive energy,
• Increased overall kVA demand,
• Increased energy consumption within the installations.
Reactive energy management aims to optimize your electrical installation by reducing energy consumption, and to improve power availability.
Total CO2 emissions are also reduced.
Utility power bills are typically reduced by 5 % to 10 %.
[Schneider Electric]Компенсация реактивной мощности
Передача по электрической сети реактивной энергии приводит к увеличению линейных токов (по сравнению токами, протекающими при передаче нагрузкам только активной энергии).
Основные последствия этого явления:
● необходимость увеличения сечения проводников в сетях передачи и распределения электроэнергии;
● повышенное падение и провалы напряжения в распределительных линиях;
● дополнительные потери электроэнергии;
Для промышленных потребителей такие потери приводят к возрастанию расходов на оплату электроэнергии, что вызвано:● штрафами, накладываемыми поставщиками электроэнергии за избыточную реактивную мощность;
● увеличением потребления полной мощности (измеряемой в кВА);
● повышенным энергопотреблением электроустановок.Цель компенсации реактивной мощности (КРМ) – оптимизация работы электроустановки за счет сокращения потребления энергии и увеличения надежности электроснабжения. Кроме того, КРМ позволяет уменьшить выбросы CO2 и сократить расходы на электроэнергию в среднем на 5-10 %.
[Перевод Интент]Наиболее эффективным способом снижения потребляемой из сети реактивной мощности является применение установок компенсации реактивной мощности (конденсаторных установок).
Использование конденсаторных установок позволяет:- разгрузить питающие линии электропередачи, трансформаторы и распределительные устройства;
- снизить расходы на оплату электроэнергии;
- при использовании определенного типа установок снизить уровень высших гармоник;
- подавить сетевые помехи, снизить несимметрию фаз;
- увеличить надежность и экономичность распределительных сетей.
На практике коэффициент мощности после компенсации находится в пределах от 0,93 до 0,99.
Наибольший экономический эффект достигается при размещении компенсирующих устройств вблизи электроприемников, потребляющих реактивную мощность.
Различают следующие виды компенсации:-
индивидуальная (нерегулируемая) компенсация
Целесообразна, если мощность электроприемника больше 20 кВт и потребляемая мощность постоянна в течение длительного времени.
Компенсирующая нерегулируемая установка подключается непосредственно у потребителя. Как правило, применяется для компенсации реактивной мощности таких потребителей, как мощные компрессоры, вентиляторы и насосы, силовые трансформаторы. - групповая (нерегулируемая) компенсация
- централизованная компенсация
Для ламп типа ДРЛ, ДРИ, ДРИЗ, ДНаТ может применяться как групповая, так и индивидуальная компенсация реактивной мощности
[ПУЭ]Тематики
Синонимы
Сопутствующие термины
- конденсатор компенсации реактивной мощности
- конденсаторная батарея компенсации реактивной мощности
- контроллер компенсации реактивной мощности
- недостаточная компенсация реактивной мощности
- перекомпенсация реактивной мощности
- потребляемая реактивная мощность
- ступень компенсации реактивной мощности
- установка КРМ
- устройства динамической компенсации реактивной мощности
EN
- energy compensation
- management of reactive energy
- power factor compensation
- reactive energy management
- reactive power compensation
DE
FR
Англо-русский словарь нормативно-технической терминологии > reactive energy management
-
6 compensation de l'énergie réactive
компенсация реактивной мощности
-EN
reactive power compensation
an action to optimize the transmission of reactive power in the network as a whole
[МЭС 603-04-28]FR
compensation de l'énergie réactive
action dont le but est d'optimiser globalement le transport d'énergie réactive dans le réseau
[МЭС 603-04-28]Параллельные тексты EN-RU
Reactive energy management
In electrical networks, reactive energy results in increased line currents for a given active energy transmitted to loads.
The main consequences are:
• Need for oversizing of transmission and distribution networks by utilities,
• Increased voltage drops and sags along the distribution lines,
• Additional power losses.
This results in increased electricity bills for industrial customers because of:• Penalties applied by most utilities on reactive energy,
• Increased overall kVA demand,
• Increased energy consumption within the installations.
Reactive energy management aims to optimize your electrical installation by reducing energy consumption, and to improve power availability.
Total CO2 emissions are also reduced.
Utility power bills are typically reduced by 5 % to 10 %.
[Schneider Electric]Компенсация реактивной мощности
Передача по электрической сети реактивной энергии приводит к увеличению линейных токов (по сравнению токами, протекающими при передаче нагрузкам только активной энергии).
Основные последствия этого явления:
● необходимость увеличения сечения проводников в сетях передачи и распределения электроэнергии;
● повышенное падение и провалы напряжения в распределительных линиях;
● дополнительные потери электроэнергии;
Для промышленных потребителей такие потери приводят к возрастанию расходов на оплату электроэнергии, что вызвано:● штрафами, накладываемыми поставщиками электроэнергии за избыточную реактивную мощность;
● увеличением потребления полной мощности (измеряемой в кВА);
● повышенным энергопотреблением электроустановок.Цель компенсации реактивной мощности (КРМ) – оптимизация работы электроустановки за счет сокращения потребления энергии и увеличения надежности электроснабжения. Кроме того, КРМ позволяет уменьшить выбросы CO2 и сократить расходы на электроэнергию в среднем на 5-10 %.
[Перевод Интент]Наиболее эффективным способом снижения потребляемой из сети реактивной мощности является применение установок компенсации реактивной мощности (конденсаторных установок).
Использование конденсаторных установок позволяет:- разгрузить питающие линии электропередачи, трансформаторы и распределительные устройства;
- снизить расходы на оплату электроэнергии;
- при использовании определенного типа установок снизить уровень высших гармоник;
- подавить сетевые помехи, снизить несимметрию фаз;
- увеличить надежность и экономичность распределительных сетей.
На практике коэффициент мощности после компенсации находится в пределах от 0,93 до 0,99.
Наибольший экономический эффект достигается при размещении компенсирующих устройств вблизи электроприемников, потребляющих реактивную мощность.
Различают следующие виды компенсации:-
индивидуальная (нерегулируемая) компенсация
Целесообразна, если мощность электроприемника больше 20 кВт и потребляемая мощность постоянна в течение длительного времени.
Компенсирующая нерегулируемая установка подключается непосредственно у потребителя. Как правило, применяется для компенсации реактивной мощности таких потребителей, как мощные компрессоры, вентиляторы и насосы, силовые трансформаторы. - групповая (нерегулируемая) компенсация
- централизованная компенсация
Для ламп типа ДРЛ, ДРИ, ДРИЗ, ДНаТ может применяться как групповая, так и индивидуальная компенсация реактивной мощности
[ПУЭ]Тематики
Синонимы
Сопутствующие термины
- конденсатор компенсации реактивной мощности
- конденсаторная батарея компенсации реактивной мощности
- контроллер компенсации реактивной мощности
- недостаточная компенсация реактивной мощности
- перекомпенсация реактивной мощности
- потребляемая реактивная мощность
- ступень компенсации реактивной мощности
- установка КРМ
- устройства динамической компенсации реактивной мощности
EN
- energy compensation
- management of reactive energy
- power factor compensation
- reactive energy management
- reactive power compensation
DE
FR
Франко-русский словарь нормативно-технической терминологии > compensation de l'énergie réactive
-
7 Blindleistungskompensation
компенсация реактивной мощности
-EN
reactive power compensation
an action to optimize the transmission of reactive power in the network as a whole
[МЭС 603-04-28]FR
compensation de l'énergie réactive
action dont le but est d'optimiser globalement le transport d'énergie réactive dans le réseau
[МЭС 603-04-28]Параллельные тексты EN-RU
Reactive energy management
In electrical networks, reactive energy results in increased line currents for a given active energy transmitted to loads.
The main consequences are:
• Need for oversizing of transmission and distribution networks by utilities,
• Increased voltage drops and sags along the distribution lines,
• Additional power losses.
This results in increased electricity bills for industrial customers because of:• Penalties applied by most utilities on reactive energy,
• Increased overall kVA demand,
• Increased energy consumption within the installations.
Reactive energy management aims to optimize your electrical installation by reducing energy consumption, and to improve power availability.
Total CO2 emissions are also reduced.
Utility power bills are typically reduced by 5 % to 10 %.
[Schneider Electric]Компенсация реактивной мощности
Передача по электрической сети реактивной энергии приводит к увеличению линейных токов (по сравнению токами, протекающими при передаче нагрузкам только активной энергии).
Основные последствия этого явления:
● необходимость увеличения сечения проводников в сетях передачи и распределения электроэнергии;
● повышенное падение и провалы напряжения в распределительных линиях;
● дополнительные потери электроэнергии;
Для промышленных потребителей такие потери приводят к возрастанию расходов на оплату электроэнергии, что вызвано:● штрафами, накладываемыми поставщиками электроэнергии за избыточную реактивную мощность;
● увеличением потребления полной мощности (измеряемой в кВА);
● повышенным энергопотреблением электроустановок.Цель компенсации реактивной мощности (КРМ) – оптимизация работы электроустановки за счет сокращения потребления энергии и увеличения надежности электроснабжения. Кроме того, КРМ позволяет уменьшить выбросы CO2 и сократить расходы на электроэнергию в среднем на 5-10 %.
[Перевод Интент]Наиболее эффективным способом снижения потребляемой из сети реактивной мощности является применение установок компенсации реактивной мощности (конденсаторных установок).
Использование конденсаторных установок позволяет:- разгрузить питающие линии электропередачи, трансформаторы и распределительные устройства;
- снизить расходы на оплату электроэнергии;
- при использовании определенного типа установок снизить уровень высших гармоник;
- подавить сетевые помехи, снизить несимметрию фаз;
- увеличить надежность и экономичность распределительных сетей.
На практике коэффициент мощности после компенсации находится в пределах от 0,93 до 0,99.
Наибольший экономический эффект достигается при размещении компенсирующих устройств вблизи электроприемников, потребляющих реактивную мощность.
Различают следующие виды компенсации:-
индивидуальная (нерегулируемая) компенсация
Целесообразна, если мощность электроприемника больше 20 кВт и потребляемая мощность постоянна в течение длительного времени.
Компенсирующая нерегулируемая установка подключается непосредственно у потребителя. Как правило, применяется для компенсации реактивной мощности таких потребителей, как мощные компрессоры, вентиляторы и насосы, силовые трансформаторы. - групповая (нерегулируемая) компенсация
- централизованная компенсация
Для ламп типа ДРЛ, ДРИ, ДРИЗ, ДНаТ может применяться как групповая, так и индивидуальная компенсация реактивной мощности
[ПУЭ]Тематики
Синонимы
Сопутствующие термины
- конденсатор компенсации реактивной мощности
- конденсаторная батарея компенсации реактивной мощности
- контроллер компенсации реактивной мощности
- недостаточная компенсация реактивной мощности
- перекомпенсация реактивной мощности
- потребляемая реактивная мощность
- ступень компенсации реактивной мощности
- установка КРМ
- устройства динамической компенсации реактивной мощности
EN
- energy compensation
- management of reactive energy
- power factor compensation
- reactive energy management
- reactive power compensation
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Blindleistungskompensation
-
8 reactive power compensation
компенсация реактивной мощности
-EN
reactive power compensation
an action to optimize the transmission of reactive power in the network as a whole
[МЭС 603-04-28]FR
compensation de l'énergie réactive
action dont le but est d'optimiser globalement le transport d'énergie réactive dans le réseau
[МЭС 603-04-28]Параллельные тексты EN-RU
Reactive energy management
In electrical networks, reactive energy results in increased line currents for a given active energy transmitted to loads.
The main consequences are:
• Need for oversizing of transmission and distribution networks by utilities,
• Increased voltage drops and sags along the distribution lines,
• Additional power losses.
This results in increased electricity bills for industrial customers because of:• Penalties applied by most utilities on reactive energy,
• Increased overall kVA demand,
• Increased energy consumption within the installations.
Reactive energy management aims to optimize your electrical installation by reducing energy consumption, and to improve power availability.
Total CO2 emissions are also reduced.
Utility power bills are typically reduced by 5 % to 10 %.
[Schneider Electric]Компенсация реактивной мощности
Передача по электрической сети реактивной энергии приводит к увеличению линейных токов (по сравнению токами, протекающими при передаче нагрузкам только активной энергии).
Основные последствия этого явления:
● необходимость увеличения сечения проводников в сетях передачи и распределения электроэнергии;
● повышенное падение и провалы напряжения в распределительных линиях;
● дополнительные потери электроэнергии;
Для промышленных потребителей такие потери приводят к возрастанию расходов на оплату электроэнергии, что вызвано:● штрафами, накладываемыми поставщиками электроэнергии за избыточную реактивную мощность;
● увеличением потребления полной мощности (измеряемой в кВА);
● повышенным энергопотреблением электроустановок.Цель компенсации реактивной мощности (КРМ) – оптимизация работы электроустановки за счет сокращения потребления энергии и увеличения надежности электроснабжения. Кроме того, КРМ позволяет уменьшить выбросы CO2 и сократить расходы на электроэнергию в среднем на 5-10 %.
[Перевод Интент]Наиболее эффективным способом снижения потребляемой из сети реактивной мощности является применение установок компенсации реактивной мощности (конденсаторных установок).
Использование конденсаторных установок позволяет:- разгрузить питающие линии электропередачи, трансформаторы и распределительные устройства;
- снизить расходы на оплату электроэнергии;
- при использовании определенного типа установок снизить уровень высших гармоник;
- подавить сетевые помехи, снизить несимметрию фаз;
- увеличить надежность и экономичность распределительных сетей.
На практике коэффициент мощности после компенсации находится в пределах от 0,93 до 0,99.
Наибольший экономический эффект достигается при размещении компенсирующих устройств вблизи электроприемников, потребляющих реактивную мощность.
Различают следующие виды компенсации:-
индивидуальная (нерегулируемая) компенсация
Целесообразна, если мощность электроприемника больше 20 кВт и потребляемая мощность постоянна в течение длительного времени.
Компенсирующая нерегулируемая установка подключается непосредственно у потребителя. Как правило, применяется для компенсации реактивной мощности таких потребителей, как мощные компрессоры, вентиляторы и насосы, силовые трансформаторы. - групповая (нерегулируемая) компенсация
- централизованная компенсация
Для ламп типа ДРЛ, ДРИ, ДРИЗ, ДНаТ может применяться как групповая, так и индивидуальная компенсация реактивной мощности
[ПУЭ]Тематики
Синонимы
Сопутствующие термины
- конденсатор компенсации реактивной мощности
- конденсаторная батарея компенсации реактивной мощности
- контроллер компенсации реактивной мощности
- недостаточная компенсация реактивной мощности
- перекомпенсация реактивной мощности
- потребляемая реактивная мощность
- ступень компенсации реактивной мощности
- установка КРМ
- устройства динамической компенсации реактивной мощности
EN
- energy compensation
- management of reactive energy
- power factor compensation
- reactive energy management
- reactive power compensation
DE
FR
Англо-русский словарь нормативно-технической терминологии > reactive power compensation
-
9 analysis
1) анализ2) исследование, изучение4) расчет ( обычно проверочный)5) состав6) теория•-
activation analysis
-
algorithmic analysis
-
amino acid analysis
-
approximate analysis
-
Auger-electron analysis
-
backward analysis
-
base ratio analysis
-
behavioral analysis
-
bending analysis
-
bottom-up analysis
-
boundary-element analysis
-
brittle coating analysis
-
buckling analysis
-
bulk analysis
-
carbon group analysis
-
cepstral analysis
-
chemical analysis
-
chromatographic analysis
-
circuit analysis
-
circuit malfunotion analysis
-
closed boundary analysis
-
clustering analysis
-
cluster analysis
-
coal-sizing analysis
-
combustion analysis
-
comfirmatory analysis
-
comparative analysis
-
compensation analysis
-
component analysis of casing head gas
-
computer aided analysis
-
core analysis
-
correlation analysis
-
coupled-mode analysis
-
covariance analysis
-
criticality analysis
-
cross correlation analysis
-
cross-field analysis
-
cryoscopic analysis
-
crystal analysis
-
cylindrical mirror Auger analysis
-
data analysis
-
depth-area-duration analysis
-
destructive analysis
-
diagnostic analysis
-
differential thermal analysis
-
diffraction analysis
-
dilatometric analysis
-
discourse analysis
-
discriminant analysis
-
dispersion analysis
-
distortion analysis
-
dynamic force analysis
-
ecological analysis
-
economic analysis
-
elastic-plastic stress analysis
-
electron diffraction analysis
-
electron microprobe analysis
-
electron probe analysis
-
emission analysis
-
end-point analysis
-
energy-dispersive analysis
-
environmental analysis
-
error analysis
-
event-sequence analysis
-
extinction analysis
-
factor analysis
-
failure analysis
-
failure cause analysis
-
fast neutron activation analysis
-
field analysis
-
fine-mesh analysis
-
fingerprint analysis
-
finite-element analysis
-
float-and-sink analysis
-
fluorescence analysis
-
formation damage analysis
-
four-dimensional analysis
-
Fourier analysis
-
fractional analysis
-
frequency analysis
-
frequency-domain analysis
-
frequency-response analysis
-
frontal analysis
-
fuel analysis
-
gamma-ray analysis
-
gradation analysis of soil
-
grading analysis
-
gravimetric analysis
-
grid-point analysis
-
group analysis
-
harmonic analysis
-
Hempel analysis
-
heteroduplex analysis
-
hot-extraction gas analysis
-
hydrograph analysis
-
immunoblot analysis
-
infrared analysis
-
Interactive analysis
-
interactive image analysis
-
ion microprobe mass analysis
-
ladle analysis
-
large-sample analysis
-
least-square analysis
-
limit state analysis
-
linear analysis
-
logical analysis
-
logic analysis
-
magnetometric analysis
-
malfunction analysis
-
market analysis
-
mass spectrographic analysis
-
mass spectrometric analysis
-
mathematical analysis
-
matrix analysis
-
measure analysis
-
mechanical analysis
-
mesh analysis
-
microprobe analysis
-
microprobe-inclusion analysis
-
microscopical analysis
-
microstructure analysis
-
mobility-shift analysis
-
modal analysis
-
model-based analysis
-
model analysis
-
moire stress analysis
-
molecular spectrum analysis
-
multilevel analysis
-
multivariate analysis
-
NDT analysis
-
nearest neighbor analysis
-
nephelometric analysis
-
network analysis
-
neutron diffraction analysis
-
nodal analysis
-
noise analysis
-
nondestructive test analysis
-
noninvasive analysis
-
numerical analysis
-
observational analysis
-
octave analysis
-
oil type analysis
-
on-line analysis
-
operations analysis
-
opticospectral analysis
-
parametric analysis
-
particle-size analysis
-
periodogram analysis
-
perturbation analysis
-
petrographic analysis
-
phase shift analysis of the scattering
-
phase-plane analysis
-
photoelastic-coating analysis
-
photoelasticity analysis
-
polarographic analysis
-
pore-size analysis
-
postaccident criticality analysis
-
posttest analysis
-
predictive analysis
-
pretest analysis
-
probit analysis
-
proximate analysis
-
qualitative analysis
-
quantitative analysis
-
radioactive tracer analysis
-
radiographic analysis
-
RAM analysis
-
rapid analysis
-
real-time analysis
-
regression analysis
-
release analysis
-
reliability analysis
-
reliability availability maintainability analysis
-
revolving field analysis
-
ring analysis
-
Rutherford scattering analysis
-
safety transit analysis
-
sample analysis
-
sampling analysis
-
scale analysis
-
screen analysis
-
sea-level analysis
-
sedimentation analysis
-
shear analysis
-
sieve analysis
-
signature analysis
-
simulated network analysis
-
single burst analysis
-
slag analysis
-
small signal analysis
-
solar resource analysis
-
spatial frequency analysis
-
spectral analysis
-
spectrophotometric analysis
-
speculative analysis
-
spot test analysis
-
stack-gas analysis
-
standing wave analysis
-
statistical analysis
-
stiffness analysis
-
strain-gage analysis
-
strength analysis
-
stress analysis
-
structural analysis
-
subsynoptic-scale analysis
-
symbolic analysis
-
syntactic analysis
-
systems analysis
-
system analysis
-
tapping analysis
-
temporal pulse analysis
-
tensor analysis
-
test sieve analysis
-
thermal analysis
-
thermoeconomic analysis
-
thermographic analysis
-
thermogravimetric analysis
-
thermomagneto-gravimetric analysis
-
three-dimensional analysis
-
time series analysis
-
timing analysis
-
top-down analysis
-
trace analysis
-
transient analysis
-
triangular hydrograph analysis
-
ultimate analysis
-
upper-level analysis
-
variance analysis
-
vault-pathways analysis
-
vector analysis
-
wandering spot analysis
-
water analysis
-
wave analysis
-
weather analysis
-
wet analysis
-
worst-case analysis
-
X-ray absorption analysis
-
X-ray analysis
-
X-ray crystal analysis
-
X-ray dispersive analysis
-
X-ray emission analysis
-
X-ray image analysis
-
X-ray spectrum analysis
-
X-ray structure analysis
-
Zuber's hydrodynamic analysis -
10 electric power supply
- электроснабжение
- снабжение электроэнергией
- обеспечение электроэнергией
- источник электропитания радиоэлектронной аппаратуры
- источник питания (в электроснабжении)
источник питания
Характеристики внешних источников питания следует принимать по техническим условиям на присоединение, выдаваемым энегоснабжающей организацией в соответствии с Правилами пользования электрической энергией...
источник питания электроэнергией
-
[Интент]
источник электропитания
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]
Основными источниками питания должны служить электростанции и сети районных энергосистем. Исключение представляют большие предприятия с большим теплопотреблением, где основным источником питания может быть собственная электростанция (ТЭЦ). Но и в этом случае обязательно должна предусматриваться связь системы электроснабжения предприятия с сетью энергосистемы.
[СН 174-75 Инструкция по проектированию электроснабжения промышленных предприятий]
1.1.2 Зануление следует выполнять электрическим соединением металлических частей электроустановок с заземленной точкой источника питания электроэнергией при помощи нулевого защитного проводника.
[ ГОСТ 12.1.030-81]
Параллельные тексты EN-RUIt is recommended that, where practicable, the electrical equipment of a machine is connected to a single incoming supply. Where another supply is necessary for certain parts of the equipment (for example, electronic equipment that operates at a different voltage), that supply should be derived, as far as is practicable, from devices (for example, transformers, converters) forming part of the electrical equipment of the machine.
[IEC 60204-1-2006]Рекомендуется, там где это возможно, чтобы электрооборудование машины получало электропитание от одного источника. Если для каких-либо частей электрооборудования машины (например для электронного оборудования, работающего на другом напряжении) необходим отдельный источник питания, то, насколько это возможно, он должен являться частью (такой, например, как трансформатор, конвертор) электрооборудования этой же машины.
[Перевод Интент]
Power supplies
The required power supplies can be determined based on the criteria for definition of the installation (receivers, power, location, etc.) and the operating conditions (safety, evacuation of the public, continuity, etc.).
They are as follows:
- Main power supply
- Replacement power supply
- Power supply for safety services
- Auxiliary power supply
[Legrand]Источники электропитания
Источники электропитания определяют по различным критериям, в соответствии с характеристиками конкретной электроустановки. Определяют типы электроприемников, их мощность, территориальное расположение и др. При этом учитывают условия эксплуатации (безопасность, требования к аварийной эвакуации людей, непрерывность технологического процесса и т. д.).
Применяют следующие источники:
- основной источник питания;
- резервный источник питания;
- аварийный источник питания систем безопасности;
- дополнительный источник питания.
[Перевод Интент]
Рис. Legrand
Типовая схема электроснабжения: 1 - Main power supply - Основной источник питания
2 - Replacement power supply (2nd source) - Резервный источник питания (2-й источник)
3 - Replacement power supply (backup) - Резервный источник питания (независимый)
4 - Auxiliary power supply - Дополнительный источник питания
5 - Power supply for safety services - Аварийный источник питания для систем безопасности
6 - Management of sources - Управление источниками питания
7 - Control - Цепь управления
8 - Main LV distrib. board - Главный распределительный щит (ГРЩ)
9 - Safety panel - Панель безопасности
10 - Uninterruptible power supply - Источник бесперебойного питания
11 - Load shedding - Отключение нагрузки
12 - Non-priority circuits - Цепи неприоритетной нагрузки
14 - Uninterruptible circuits - Цепи бесперебойного питания
15 - Shed circuits - Цепи отключаемой нагрузки
16 - Safety circuits - Цепи систем безопасностиТематики
Близкие понятия
Действия
Синонимы
Сопутствующие термины
- аварийный источник питания
- взаимно резервируемые источники питания
- внешний источник питания
- дополнительный источник питания
- источник бесперебойного питания
- источник питания с ограничением тока
- независимый источник питания
- основной источник питания
- резервный источник питания
EN
источник электропитания радиоэлектронной аппаратуры
источник электропитания РЭА
Нерекомендуемый термин - источник питания
Устройство силовой электроники, входящее в состав радиоэлектронной аппаратуры и преобразующее входную электроэнергию для согласования ее параметров с входными параметрами составных частей радиоэлектронной аппаратуры.
[< size="2"> ГОСТ Р 52907-2008]
источник питания
Часть устройства, обеспечивающая электропитание остальных модулей устройства.
[ http://www.lexikon.ru/dict/net/index.html]EN
power supply
An electronic module that converts power from some power source to a form which is needed by the equipment to which power is being supplied.
[Comprehensive dictionary of electrical engineering / editor-in-chief Phillip A. Laplante.-- 2nd ed.]
Рис. ABB
Структурная схема источника электропитанияThe input side and the output side are electrically isolated against each other
Вход и выход гальванически развязаны
Терминология относящая к входу
Primary side
Первичная сторона
Input voltage
Входное напряжение
Primary grounding
Current consumption
Потребляемый ток
Inrush current
Пусковой ток
Input fuse
Предохранитель входной цепи
Frequency
Частота
Power failure buffering
Power factor correction (PFC)
Коррекция коэффициента мощности
Терминология относящая к выходу
Secondary side
Вторичная сторона
Output voltage
Выходное напряжение
Secondary grounding
Short-circuit current
То короткого замыкания
Residual ripple
Output characteristics
Выходные характеристики
Output current
Выходной ток
Различают первичные и вторичные источники питания.
К первичным относят преобразователи различных видов энергии в электрическую, например:
- аккумулятор (преобразует химическую энергию.
Вторичные источники не генерируют электроэнергию, а служат лишь для её преобразования с целью обеспечения требуемых параметров (напряжения, тока, пульсаций напряжения и т. п.)Задачи вторичного источника питания
- Обеспечение передачи мощности — источник питания должен обеспечивать передачу заданной мощности с наименьшими потерями и соблюдением заданных характеристик на выходе без вреда для себя. Обычно мощность источника питания берут с некоторым запасом.
- Преобразование формы напряжения — преобразование переменного напряжения в постоянное, и наоборот, а также преобразование частоты, формирование импульсов напряжения и т. д. Чаще всего необходимо преобразование переменного напряжения промышленной частоты в постоянное.
- Преобразование величины напряжения — как повышение, так и понижение. Нередко необходим набор из нескольких напряжений различной величины для питания различных цепей.
- Стабилизация — напряжение, ток и другие параметры на выходе источника питания должны лежать в определённых пределах, в зависимости от его назначения при влиянии большого количества дестабилизирующих факторов: изменения напряжения на входе, тока нагрузки и т. д. Чаще всего необходима стабилизация напряжения на нагрузке, однако иногда (например для зарядки аккумуляторов) необходима стабилизация тока.
- Защита — напряжение или ток нагрузки в случае неисправности (например, короткого замыкания) каких-либо цепей может превысить допустимые пределы и вывести электроприбор или сам источник питания из строя. Также во многих случаях требуется защита от прохождения тока по неправильному пути: например прохождения тока через землю при прикосновении человека или постороннего предмета к токоведущим частям.
- Гальваническая развязка цепей — одна из мер защиты от протекания тока по неверному пути.
- Регулировка — в процессе эксплуатации может потребоваться изменение каких-либо параметров для обеспечения правильной работы электроприбора.
- Управление — может включать регулировку, включение/отключение каких-либо цепей или источника питания в целом. Может быть как непосредственным (с помощью органов управления на корпусе устройства), так и дистанционным, а также программным (обеспечение включения/выключения, регулировка в заданное время или с наступлением каких-либо событий).
- Контроль — отображение параметров на входе и на выходе источника питания, включения/выключения цепей, срабатывания защит. Также может быть непосредственным или дистанционным.
Трансформаторный (сетевой) источник питания
Чаще всего состоит из следующих частей:- Сетевого трансформатора, преобразующего величину напряжения, а также осуществляющего гальваническую развязку;
- Выпрямителя, преобразующего переменное напряжение в пульсирующее;
- Фильтра для снижения уровня пульсаций;
- Стабилизатора напряжения для приведения выходного напряжения в соответствие с номиналом, также выполняющего функцию сглаживания пульсаций за счёт их «срезания».
В сетевых источниках питания применяются чаще всего линейные стабилизаторы напряжения, а в некоторых случаях и вовсе отказываются от стабилизации.
Достоинства такой схемы:- Простота построения и обслуживания
- Надёжность
- Низкий уровень радиопомех.
Недостатки:
- Большой вес и габариты, особенно при большой мощности: по большей части за счёт габаритов трансформатора и сглаживающего фильтра
- Металлоёмкость
- Применение линейных стабилизаторов напряжения вводит компромисс между стабильностью выходного напряжения и КПД: чем больше диапазон изменения напряжения, тем больше потери мощности.
- При отсутствии стабилизатора на выход источника питания проникают пульсации с частотой 100Гц.
В целом ничто не мешает применить в трансформаторном источнике питания импульсный стабилизатор напряжения, однако большее распространение получила схема с полностью импульсным преобразованием напряжения.
Импульсный источник питания
Широко распространённая схема импульсного источника питания состоит из следующих частей:- Входного фильтра, призванного предотвращать распространение импульсных помех в питающей сети
- Входного выпрямителя, преобразующего переменное напряжение в пульсирующее
- Фильтра, сглаживающего пульсации выпрямленного напряжения
- Прерывателя (обычно мощного транзистора, работающего в ключевом режиме)
- Цепей управления прерывателем (генератора импульсов, широтно-импульсного модулятора)
- Импульсного трансформатора, который служит накопителем энергии импульсного преобразователя, формирования нескольких номиналов напряжения, а также для гальванической развязки цепей (входных от выходных, а также, при необходимости, выходных друг от друга)
- Выходного выпрямителя
- Выходных фильтров, сглаживающих высокочастотные пульсации и импульсные помехи.
Достоинства такого блока питания:
- Можно достичь высокого коэффициента стабилизации
- Высокий КПД. Основные потери приходятся на переходные процессы, которые длятся значительно меньшее время, чем устойчивое состояние.
- Малые габариты и масса, обусловленные как меньшим выделением тепла на регулирующем элементе, так и меньшими габаритами трансформатора, благодаря тому, что последний работает на более высокой частоте.
- Меньшая металлоёмкость, благодаря чему мощные импульсные источники питания стоят дешевле трансформаторных, несмотря на бо́льшую сложность
- Возможность включения в сети широкого диапазона напряжений и частот, или даже постоянного тока. Благодаря этому возможна унификация техники, производимой для различных стран мира, а значит и её удешевление при массовом производстве.
Однако имеют такие источники питания и недостатки, ограничивающие их применение:
- Импульсные помехи. В связи с этим часто недопустимо применение импульсных источников питания для некоторых видов аппаратуры.
- Невысокий cosφ, что требует включения компенсаторов коэффициента мощности.
- Работа большей части схемы без гальванической развязки, что затрудняет обслуживание и ремонт.
- Во многих импульсных источниках питания входной фильтр помех часто соединён с корпусом, а значит такие устройства требуют заземления.
[Википедия]
Недопустимые, нерекомендуемые
Тематики
Обобщающие термины
Синонимы
EN
обеспечение электроэнергией
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]
обеспечение электроэнергией
-
[Перевод Интент]EN
electric power supply
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
снабжение электроэнергией
блок электропитания
источник электропитания
—
[Л.Г.Суменко. Англо-русский словарь по информационным технологиям. М.: ГП ЦНИИС, 2003.]Тематики
Синонимы
EN
электроснабжение
Обеспечение потребителей электрической энергией.
[ ГОСТ 19431-84]Качество электрической энергии (КЭ) тесно связано с надежностью электроснабжения, поскольку нормальным режимом электроснабжения потребителей является такой режим, при котором потребители получают электроэнергию бесперебойно, в количестве, заранее согласованном с энергоснабжающей организацией, и нормированного качества.
[В. В. Суднова. Качество электрической энергии]Тематики
Действия
Сопутствующие термины
- бесперебойность электроснабжения
- надежность электроснабжения
- нарушение электроснабжения
- нормальный режим электроснабжения
- проект электроснабжения
- электроснабжение от автономного источника питания электроэнергией
EN
Англо-русский словарь нормативно-технической терминологии > electric power supply
См. также в других словарях:
Energy quality — the contrast between different forms of energy, the different trophic levels in ecological systems and the propensity of energy to convert from one form to another. The concept refers to our empirical experience of the characteristics, or qualia … Wikipedia
Energy demand management — Energy portal Energy demand management, also known as demand side management (DSM), is the modification of consumer demand for energy through various methods such as financial incentives and education. Usually, the goal of demand side management… … Wikipedia
Energy returned on energy invested — Contents 1 Non manmade energy inputs 2 Relationship to net energy gain 3 The economic influence of EROEI … Wikipedia
Energy security — is a term for an association between national security and the availability of natural resources for energy consumption. Access to cheap energy has become essential to the functioning of modern economies. However, the uneven distribution of… … Wikipedia
Energy policy of India — The energy policy of India is characterized by tradeoffs between four major drivers: * Rapidly growing economy, with a need for dependable and reliable supply of electricity, gas, and petroleum products; * Increasing household incomes, with a… … Wikipedia
Energy development — Schematic of the global sources of energy in 2006 2007 … Wikipedia
Intermittent energy source — An intermittent energy source is any source of energy that is not continuously available due to some factor outside direct control. The intermittent source may be quite predictable, for example, tidal power, but cannot be dispatched to meet the… … Wikipedia
Capacity factor — The net capacity factor of a power plant is the ratio of the actual output of a power plant over a period of time and its output if it had operated at full nameplate capacity the entire time. To calculate the capacity factor, total the energy the … Wikipedia
Outline of energy — See also: Index of energy articles In physics, energy (from the Greek ἐνέργεια – energeia, activity, operation , from ἐνεργός – energos, active, working [1]) is a scalar physical quantity that describes the amount of work that can be performed by … Wikipedia
Demand factor — In telecommunication, electronics and the electrical power industry, the term demand factor has the following meanings: 1. The ratio of (a) the maximum real power consumed by a system to (b) the maximum real power that would be consumed if the… … Wikipedia
Duke Energy — Corporation Type Public(NYSE: DUK) S P 500 Component Industry … Wikipedia
Перевод: со всех языков на русский
с русского на все языки- С русского на:
- Все языки
- Со всех языков на:
- Все языки
- Английский
- Испанский
- Немецкий
- Русский
- Французский