  • 1 длительный допустимый ток

    1. Strombelastbarkeit, f
    2. Dauerstrombelastbarkeit, f

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-немецкий словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • Damaged good — In economics, a damaged good (sometimes termed crippleware or product with anti features ) is a good that has been deliberately limited in performance, quality or utility,[1][2][3] typically for marketing reasons as part of a strategy of product… …   Wikipedia

  • Iraq — /i rak , i rahk /, n. a republic in SW Asia, N of Saudi Arabia and W of Iran, centering in the Tigris Euphrates basin of Mesopotamia. 22,219,289; 172,000 sq. mi. (445,480 sq. km). Cap.: Baghdad. Also, Irak. * * * Iraq Introduction Iraq Background …   Universalium

  • Vehicle history report — A vehicle history report in the US contains important information about a used vehicle’s past. These reports generally show title records from each state DMV, along with salvage and insurance total loss records and accident records (1, 2, 7).… …   Wikipedia

  • Automated optical inspection — (AOI) is an automated visual inspection of a wide range of products, such as printed circuit boards (PCBs), LCDs, transistors, automotive parts, lids and labels on product packages or agricultural products (seed corn or fruits). In case of PCB… …   Wikipedia

  • World War II Online — World War II Online: Battleground Europe …   Wikipedia

  • Applications of artificial intelligence — Artificial intelligence has been used in a wide range of fields including medical diagnosis, stock trading, robot control, law, scientific discovery and toys. However, many AI applications are not perceived as AI: A lot of cutting edge AI has… …   Wikipedia

  • United Airlines Flight 811 — Illustration of Flight 811 just after decompression Accident summary Date February 24, 1989 …   Wikipedia

  • 5DX — The 5DX is an automated x ray inspection robot, which belongs to the set of automated test equipment robots and industrial robots utilizing machine vision. The 5DX is manufactured by Agilent Technologies. The 5DX is a non destructive structural… …   Wikipedia

  • Multi-jackbolt tensioner — Multi jackbolt tensioners (MJT) provide an alternative to traditional bolted joints Rather than needing to tighten one large bolt, MJTs use several smaller jackbolts to drastically reduce the torque required to attain a certain preload. MJTs… …   Wikipedia

  • Top Fuel — Racing is a class of drag racing in which the cars are run on a maximum of 90% nitromethane and about 10% methanol (also known as racing alcohol), instead of gasoline. The cars are purpose built race cars, with a layout superficially resembling… …   Wikipedia

  • Continuity test — In electronics, a continuity test is the checking of an electric circuit to see if current flows (that it is in fact a complete circuit). A continuity test is performed by placing a small voltage (wired in series with an LED or noise producing… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»