-
41 current
1) поток; течение2) ток, электрический ток3) текущий; действующий•- base current
- breakover current
- brushless direct current
- cancel current
- carrier current
- charging current
- continuous current
- continuous reverse conducting current
- control current
- counter current
- critical current
- cutoff current
- direct current
- discharge current
- displacement current
- disturbance current
- driving current
- drop-out current
- earth current
- eddy currents
- electric current
- exciting current
- forward gate current
- forward recovery current
- gap current
- gate continuous current
- gate current
- gate direct current
- gate nontrigger current
- gate nonturn-off current
- gate trigger current
- gate turn-off current
- heater current
- holding current
- induced current
- interference current
- inverse current
- latching current
- leakage current
- limiting continuous current
- limiting short-time current
- line current
- mean on-state current
- mean reverse conducting current
- multiphase current
- no-load current
- nonrepetitive current
- off-state current
- on-state current
- operational current
- overload current
- overload reverse conducting current
- peak forward gate current
- peak gate current
- peak gate nontrigger current
- peak gate nonturn-off current
- peak gate trigger current
- peak gate turn-off current
- peak reverse gate current
- peak withstand current
- primary current
- principal current
- prospective breaking current
- prospective current
- prospective making current
- pulsating current
- R.M.S. on-state current
- R.M.S. reverse conducting current
- rated continuous thermal current
- rated control current
- rated current
- rated dynamics current
- rated instrument limit primary current
- rated operational current
- rated short-time thermal current
- rated temperature-rise current
- recovery current
- regular current
- releasing current
- repetitive off-state current
- repetitive peak current
- residual current
- reverse conducting current
- reverse current
- reverse gate current
- reverse recovery current
- secondary current
- short-circuit current
- short-time current
- short-time withstand current
- single-phase current
- spindle motor current
- starting current
- surface leakage current
- surge current
- surge on-state current
- surge reverse conducting current
- synchronizing current
- three-phase current
- threshold current
- trigger current
- tube current
- turn-off current
- unbalanced current
- unidirectional currentEnglish-Russian dictionary of mechanical engineering and automation > current
-
42 circuit
1) схема; цепь; контур2) линия3) канал4) сеть•- adapter circuit
- adjustment circuit
- alive circuit
- announcing circuit
- anode circuit
- antisidetone circuit
- asynchronous circuit
- automatic reset-data circuit
- automatic ringdown circuit
- automatic start circuit
- auxiliary circuit
- balanced circuit
- balanced-wire circuit
- balancing circuit
- band-switching circuit
- basic circuit
- black-level restoring circuit
- black-level stretch circuit
- bootstrap circuit
- branch circuit
- branched circuit
- bridge antisidetone circuit
- building-out circuit
- built-up circuit
- Buttler circuit
- bypass circuit
- cached circuit
- call circuit
- capacitor-coupled circuit
- capacitor-switched circuit
- capacitor-switching circuit
- central-battery circuit
- chain-type connection circuit
- character generator large-scale integration circuit
- charge-coupled device circuit
- check parity circuit
- checkout circuit
- chrominance matrix circuit
- chrominance separation circuit
- chrominance takeoff circuit
- clamp-on circuit
- closed circuit
- coarse phasing circuit
- coaxial circuit
- coincidence circuit
- color-balance circuit
- color-indexing circuit
- color-purity circuit
- combinational-circuit circuit
- combined-supply circuit
- common-base circuit
- common-battery circuit
- common-collector circuit
- common-drain circuit
- common-emitter circuit
- common-gate circuit
- common-source circuit
- common-user circuit
- communication circuit
- comparing circuit
- compensating antisidetone circuit
- complemental metal-oxide-semiconductor circuit
- composite circuit
- conductor-bundled static wire circuit
- conference circuit
- connecting circuit
- constant-closed circuit
- contactor-relay circuit
- continental circuit
- convergence circuit
- cord circuit
- correcting circuit
- Costas circuit
- counter-coupling circuit
- counting-down circuit
- coupled circuit
- cross-bus matrix circuit
- crossed-waveguide circuit
- cue circuit
- cutoff circuit
- Darlingtone circuit
- data circuit
- data-transmission circuit
- dc restoration circuit
- decoder circuit
- delay circuit
- demodulation circuit
- dial-up circuit
- diamond circuit
- differencing circuit
- differential-frequency circuit
- digital circuit
- digital-excitation circuit
- digital-leased circuit
- diode-clamping circuit
- diode-clipping circuit
- diode-stabilitron circuit
- direct international circuit
- direct-connection circuit
- direct-transit international circuit
- direct-wire circuit
- double half-wave circuit
- double-ended cord circuit
- double-loop circuit
- dual circuit
- earth circuit
- earthed circuit
- echo-absorption circuit
- edge derivation circuit
- electric circuit
- electronic circuit
- elementary circuit
- encoding circuit
- energized circuit
- engineering circuit
- equivalent circuit
- error-subtracting circuit
- external circuit
- fallback circuit
- feed circuit
- feedback circuit
- fiber-optic circuit
- fire-control circuit
- fixed-virtual circuit
- flexible circuit
- flexible-stage circuit
- flywheel circuit
- forked circuit
- four-wire circuit
- frame scanning circuit
- frequency-changing circuit
- frequency-protection circuit
- full-accessible circuit
- full-period allocated circuit
- functional-switching circuit
- gallium-arsenide integrated circuit
- gating circuit
- generating circuit
- Gilbert circuit
- Grets circuit
- grid circuit
- ground-return circuit
- grouping circuit
- half-bridge circuit
- half-wave circuit
- hardened circuit
- head circuit
- HF-correction circuit
- holding circuit
- horizontal deflection circuit
- hybrid circuit
- hypothetical reference circuit
- idle lighting limiting circuit
- inclined adjustment circuit
- incoming circuit
- independent circuit
- inductive circuit
- input circuit
- input-by-output matrix circuit
- inquiry circuit
- integrated circuit
- integrating circuit
- interchange circuit
- interface-integrated circuit
- interferenced circuit
- interferencing circuit
- international leased circuit
- interstage coupling circuit
- invertor circuit
- ISDN echo cancellation circuit
- isochronic circuit
- Jiakoletto circuit
- junction circuit
- Karp circuit
- keep-alive circuit
- key section power circuit
- killer circuit
- ladder circuit
- lamp circuit
- large-scale integration circuit
- latched circuit
- LCR circuit
- lead changeover circuit
- LF-correction circuit
- line circuit
- linear circuit
- link circuit
- live circuit
- local circuit
- lock-in circuit
- locking circuit
- lock-out circuit
- long circuit
- long-distance circuit
- longitudinal circuit
- loop circuit
- lossless resonant circuit
- L-shaped circuit
- magnetic convergence circuit
- main supply circuit
- make circuit
- Marx circuit
- match circuit
- matching circuit
- matrix circuit
- message circuit
- microelectronic circuit
- microphone supply circuit
- multidrop circuit
- multijunctor circuit
- multiloop circuit
- multipoint circuit
- muting circuit
- neodymium magnetic circuit
- neutral circuit
- neutralization circuit
- neutralizing circuit
- noise-rejecting circuit
- noise-suicide circuit
- nonlinear circuit
- NOT circuit
- on-call circuit
- open circuit
- optoelectronic integrated circuit
- OR circuit
- order wire circuits
- OR-ELSE circuit
- oscillating circuit
- oscillation circuit
- output circuit
- output voltage tracking circuit
- packaged circuit
- paging circuit
- parallel circuit
- partially accessible circuit
- peaking circuit
- periodic closed circuit
- phantom circuit
- phase comparating circuit
- phase compensating circuit
- phase-shift circuit
- phase-substitution circuit
- physical circuit
- pilot circuit
- pilot-make-busy circuit
- planar circuit
- point-to-point circuit
- polling circuit
- polyphase circuit
- power circuit
- power-supply circuit
- precision phasing circuit
- primary circuit
- printed circuit
- private leased circuit
- protection circuit
- pulse-phase control circuit
- push-to-talk circuit
- push-to-type circuit
- quenching circuit
- quiet-tuning circuit
- radial supply circuit
- radio circuit
- RC circuit
- reactance control circuit
- reading circuit
- rectification circuit
- reference circuit
- rejecting circuit
- relay cutout circuit
- remote control circuit
- remote-ring circuit
- repeat circuit
- reset circuit
- resonance circuit
- resonant circuit
- reverse circuit
- reverse diode circuit
- ring circuit
- ringing circuit
- sample-and-hold circuit
- scaling circuit
- Scott circuit
- secondary circuit
- section substitution circuit
- selecting circuit
- selective circuit
- self-locked circuit
- series circuit
- series-oscillating circuit
- series-parallel circuit
- series-peaking circuit
- series-tuned circuit
- shaping circuit
- shaved single frequency circuit
- short circuit
- shunt circuit
- shunting circuit
- shunt-peaking circuit
- side circuit
- signal circuit
- signal processing circuit
- signal recovery circuit
- single-current circuit
- single-ended push-pull circuit
- single-frequency resonance circuit
- single-phase bridge circuit
- single-phase circuit
- snap-acting circuit
- solving circuit
- sound-program circuit
- spark-safe circuit
- speech circuit
- speed regulating circuit
- squaring circuit
- stabilizer circuit
- stable circuit
- stage circuit
- stage control circuit
- standard cable circuit
- standard circuit
- standby circuit
- stenode circuit
- storage large-scale integration circuit
- storage locking circuit
- straightforward circuit
- strap magnetic circuit
- strip-line circuit
- super large scale integration circuit
- superimposed circuit
- superposed circuit
- supply circuit
- sweep circuit
- switched circuit
- switching circuit
- symistor control circuit
- synchronous circuit
- tail circuit
- talk-back circuit
- tandem data circuit
- tank circuit
- tapped magnetic circuit
- tapped stage circuit
- telecommunication circuit
- telecommunication-protection circuit
- telegraph circuit
- telegraph grade circuit
- telegraph signal generating circuit
- telephone circuit
- telephone signal generating circuit
- telesignaling receiving circuit
- telesignaling sending circuit
- television circuit
- terminal circuit
- test circuit
- testing circuit
- third circuit
- three-loop circuit
- three-phase input circuit
- three-wire circuit
- through circuit
- thyristor control circuit
- time protection circuit
- time-delay circuit
- time-interval protection circuit
- time-setting circuit
- timing circuit
- toll circuit
- touch sensing circuit
- touch tone dial circuit
- transformer substitution circuit
- transformer-coupled circuit
- transistor clipping circuit
- transistor collector circuit
- transistor control circuit
- transistor protection circuit
- tributary circuit
- triode clamp circuit
- trunk circuit
- T-shaped circuit
- tuned circuit
- twelve-pulse circuit
- two-frequency resonance circuit
- two-loop circuit
- two-wire-ground circuit
- uniform circuit
- unstable circuit
- untapped circuit
- untapped magnetic circuit
- U-shaped circuit
- variometer controlling circuit
- video circuit
- virtual circuit
- voice circuit
- voltage multiplying circuit
- voltage sensor circuit
- watching output circuit
- wideband circuit
- wire circuit
- wired circuitEnglish-Russian dictionary of telecommunications and their abbreviations > circuit
-
43 circuit
цепь, схема; линия связи; круг ( над аэродромом) ; полет по кругу; посадочный круг; оборот ( спутника вокруг планеты) ; летать по кругу, делать круг (и) -
44 limiting short-time current of an output circuit
- предельный кратковременный ток выходной цепи электрического реле
- предельный кратковременный ток выходной цепи
предельный кратковременный ток выходной цепи
-
[IEV number 445-04-01]EN
limiting short-time current of an output circuit
short-time withstand current of an output circuit (deprecated)
highest value of electric current which a closed contact or an effectively conducting output circuit is capable of carrying for a specified short period under specified conditions
[IEV number 445-04-01]FR
courant limite de courte durée d'un circuit de sortie, m
valeur la plus élevée du courant électrique qu'un contact fermé ou un circuit de sortie à l'état passant est capable de supporter dans des conditions spécifiées et pendant une courte durée spécifiée
[IEV number 445-04-01]Тематики
- электротехника, основные понятия
EN
- limiting short-time current of an output circuit
- short-time withstand current of an output circuit (deprecated)
DE
FR
предельный кратковременный ток выходной цепи электрического реле
Наибольшее значение тока, которое предварительно замкнутая или находящаяся в проводящем состоянии выходная цепь электрического реле способна выдерживать в заданных условиях в течение заданного короткого промежутка времени
[ ГОСТ 16022-83]Тематики
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > limiting short-time current of an output circuit
-
45 limiting value of the non-operating current in case of unbalanced load in a multiphase circuit
- предельное значение тока несрабатывания при неравномерной нагрузке в многофазной цепи
предельное значение тока несрабатывания при неравномерной нагрузке в многофазной цепи
-
[IEV number 442-05-63]EN
limiting value of the non-operating current in case of unbalanced load in a multiphase circuit
Maximum value of current which, in the absence of any fault to frame or to earth, and of an earth leakage current, can flow in a circuit containing only two active conductors of the installation, without causing operation of the part of the residual current device performing the evaluation.
[IEV number 442-05-63]FR
valeur limite du courant de non-fonctionnement en service déséquilibré dans un circuit polyphasé
Valeur maximale du courant pouvant circuler, en l'absence de tout défaut à la masse ou à la terre et de tout courant de fuite à la terre, dans un circuit intéressant seulement deux conducteurs actifs de l'installation sans provoquer le fonctionnement de la partie du dispositif de coupure différentiel assurant la fonction mesure.
[IEV number 442-05-63]EN
- limiting value of the non-operating current in case of unbalanced load in a multiphase circuit
DE
- Grenzwert der Nichtbetätigungs-Überstromstärke bei unsymmetrischen Lasten in einem Mehrphasen-Stromkreis
FR
- valeur limite du courant de non-fonctionnement en service déséquilibré dans un circuit polyphasé
Англо-русский словарь нормативно-технической терминологии > limiting value of the non-operating current in case of unbalanced load in a multiphase circuit
-
46 limiting value of the non-operating current in case of balanced load
предельное значение тока несрабатывания при равномерной нагрузке
-
[IEV number 442-05-64]EN
limiting value of the non-operating current in case of balanced load
Maximum value of current which, in the absence of any fault to frame or to earth, and of an earth leakage current, can flow in a circuit without any load unbalance, without causing operation of the part of the residual current device performing the evaluation.
[IEV number 442-05-64]FR
valeur limite du courant de non-fonctionnement en service équilibré
Valeur maximale du courant pouvant circuler dans un circuit, en l'absence de tout défaut à la masse ou à la terre et de tout courant de fuite à la terre en l'absence de tout déséquilibre de charge, sans provoquer le fonctionnement de la partie du dispositif de coupure différentiel assurant la fonction mesure.
[IEV number 442-05-64]EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > limiting value of the non-operating current in case of balanced load
-
47 limiting continuous current of an output circuit
предельный длительный ток выходной цепи электрического реле
Наибольшее значение тока, которое предварительно замкнутая или находящаяся в проводящем состоянии выходная цепь электрического реле способна выдерживать длительно в заданных условиях
[ ГОСТ 16022-83]Тематики
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > limiting continuous current of an output circuit
-
48 conditional short-circuit current (of a circuit or a switching device)
условный ток короткого замыкания (в цепи или коммутационном аппарате)
Ожидаемый ток, который цепь или коммутационнный аппарат, защищенные установленным устройством от коротких замыканий, способны удовлетворительно выдерживать в течение всего времени срабатывания этого устройства в указанных условиях эксплуатации и поведения.
Примечания
1 В настоящем стандарте устройством для защиты от коротких замыканий служит, как правило, автоматический выключатель или плавкие предохранители.
2 Это определение отличается от МЭК 60050(441-17-20) расширением понятия токоограничивающего аппарата до устройства для защиты от коротких замыканий, функция которого не сводится только к токоограничению.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
conditional short-circuit current (of a circuit or a switching device)
the prospective current that a circuit or a switching device, protected by a specified current limiting device, can satisfactorily withstand for the operating time of that current limiting device under specified conditions of use and behaviour
[IEV number 441-17-20]FR
courant de court-circuit conditionnel (d'un circuit ou d'un appareil de connexion)
courant présumé qu'un circuit ou un appareil de connexion, protégé par un dispositif limiteur de courant spécifié, peut supporter de façon satisfaisante pendant la durée de fonctionnement de cet appareil limiteur de courant dans des conditions spécifiées d'emploi et de comportement
[IEV number 441-17-20]Тематики
- выключатель автоматический
- выключатель, переключатель
- предохранитель
- электротехника, основные понятия
EN
DE
FR
- courant de court-circuit conditionnel (d'un circuit ou d'un appareil de connexion)
Англо-русский словарь нормативно-технической терминологии > conditional short-circuit current (of a circuit or a switching device)
-
49 band limiting
-
50 integrated circuit resistor
pull-down resistor — согласующий резистор; резистор утечки
etched resistor — резистор, полученный методом травления
The English-Russian dictionary general scientific > integrated circuit resistor
-
51 assembly equipped with devices limiting internal arc effects
НКУ с устройствами ограничения воздействия внутренней дуги
-
[Интент]Параллельные тексты EN-RU
Assemblies equipped with devices limiting internal arc effects (active protection)
A design philosophy which is completely different from that just considered consists in guaranteeing the resistance to internal arcing by installing devices limiting the arc.
The approaches in that direction can be of two different types:
• limiting the destructive effects of the arc, once it has occured, by means of arc detectors
• limiting the destructive effects of the arc, once it has occured, by means of overpressure detectors.
The first possibility consists in installing in the assembly arc detectors which sense the light flux associated with the electric arc phenomenon.
Once the arc has been detected, these devices send an opening signal to the incoming circuit-breaker, thus guaranteeing tripping times of the order of 1-2 ms, therefore shorter than those proper of the circuit-breaker.
The operating logic of an arc detector is the following: the occurrence of an arc inside the switchboard is detected by the arc detector because an intense light radiation is associated with this phenomenon.
The arcing control system detects the event and sends a tripping signal to the circuit-breaker.
All the above with trip times of a few milliseconds and supplanting the tripping of the CB overcurrent relay which, for example, could be delayed due to current selectivity questions.
Figure 1 shows the possible positions where this device can be installed inside a switchboard.
The ideal solution is that which provides the installation of at least one detector for each column, with the consequent reduction to a minimum of the length of the optical fibers carrying the signal.
In order to prevent from an unwanted tripping caused by light sources indepent of the arc (lamps, solar radiation etc.), an additional current sensor is often positioned at the incoming of the main circuit-breaker.
Only in the event of an arc, both the incoming sensor which detects an “anomalous” current due to the arc fault as well as the sensor detecting the light radiation as sociated with the arc enable the system to intervene and allow the consequent opening of the circuit-breaker.
The second possibility consists in installing overpressure sensors inside the switchboard.
As previously described, the overpressure wave is one of the other effects occurring inside an assembly in case of arcing.
As a consequence it is possible to install some pressure sensors which are able to signal the pressure peak associated with the arc ignition with a delay of about 10-15 ms.
The signal operates on the supply circuit-breaker without waiting for the trip times of the selectivity protections to elapse, which are necessarily longer.
Such a system does not need any electronic processing device, since it acts directly on the tripping coil of the supply circuit-breaker.
Obviously it is essential that the device is set at fixed trip thresholds.
When an established internal overpressure is reached, the arc detector intervenes.
However, it is not easy to define in advance the value of overpressure generated by an arc fault inside a switchboard.
[ABB]НКУ с устройствами ограничения воздействия внутренней дуги (активная защита)
Для решения этой задачи используются совершенно другие, отличающиеся от ранее рассмотренных, принципы, заключающиеся в том, что противодействие внутренней дуге обеспечивается применением устройств, ограничивающих саму дугу.
Существует два типа решения проблемы в этом направлении:
• ограничение разрушающего воздействия дуги после того, как ее обнаружат специальные устройства
• ограничение разрушающего воздействия дуги после того, как специальные устройства обнаружат возникновение избыточного давления.
В первом случае в НКУ устанавливают устройства обнаружения дуги, реагирующие на световой поток, сопровождающий явление электрической дуги.
При обнаружении дуги данные устройства посылают сигнал управления на размыкание вводного автоматического выключателя. Гарантируемое время реакции составляет 1-2 мс, что меньше времени срабатывания автоматического выключателя.
Логика работы устройства обнаружения дуги следующая: Дуга, возникшая внутри НКУ, обнаруживается датчиком, реагирующим на интенсивное световое излучение, которым сопровождается горение дуги.
Обнаружив дугу, система управления посылает сигнал автоматическому выключателю.
Время срабатывания датчика и системы управления составляет несколько миллисекунд, что меньше времени срабатывания автоматического выключателя, осуществляющего защиту от сверхтока, который обычно для обеспечения требуемой селективности срабатывает с задержкой.
На рис. 1 показаны места возможной установки устройства защиты внутри НКУ.
Идеальным решением является установка, по крайней мере, одного устройства защиты в каждый шкаф многошкафного НКУ.
Это позволит до минимума сократить длину оптоволоконных кабелей передачи сигнала.
Для предотвращения ложного срабатывания от других источников света (т. е. не от дуги), например, таких как лампы, солнечное излучение и т. п., дополнительно в главной цепи вводного автоматического выключателя устанавливают датчик тока.
Только при наличии двух событий, а именно: срабатывания датчика света и обнаружения аномального увеличения тока, система управления считает, что возникла электрическая дуга и подает команду на отключение вводного автоматического выключателя.
Второе решение заключается в установке внутри НКУ датчика избыточного давления.
Как было описано ранее, одним из характерных проявлений электрической дуги, возникшей внутри НКУ, является ударная волна.
Это означает, что можно установить несколько датчиков давления, задачей которых является обнаружение импульса давления (с задержкой 10…15 мс), обусловленного зажиганием дуги.
Сигнал от датчиков давления поступает на вводной автоматический выключатель, который срабатывает без задержки на обеспечение селективности.
Такая система не нуждается в электронном устройстве обработки информации, поскольку воздействует непосредственно на независимый расцепитель автоматического выключателя.
Вполне понятно, что такое устройство имеет фиксированный порог срабатывания.
Датчик-реле дуги сработает, как только будет достигнуто заданное значение избыточного давления.
Следует иметь в виду, что не так легко заранее определить значение избыточного давления, которое будет создано при зажигании дуги внутри НКУ.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
EN
Англо-русский словарь нормативно-технической терминологии > assembly equipped with devices limiting internal arc effects
-
52 short-time withstand current of an output circuit (deprecated)
предельный кратковременный ток выходной цепи
-
[IEV number 445-04-01]EN
limiting short-time current of an output circuit
short-time withstand current of an output circuit (deprecated)
highest value of electric current which a closed contact or an effectively conducting output circuit is capable of carrying for a specified short period under specified conditions
[IEV number 445-04-01]FR
courant limite de courte durée d'un circuit de sortie, m
valeur la plus élevée du courant électrique qu'un contact fermé ou un circuit de sortie à l'état passant est capable de supporter dans des conditions spécifiées et pendant une courte durée spécifiée
[IEV number 445-04-01]Тематики
- электротехника, основные понятия
EN
- limiting short-time current of an output circuit
- short-time withstand current of an output circuit (deprecated)
DE
FR
Англо-русский словарь нормативно-технической терминологии > short-time withstand current of an output circuit (deprecated)
-
53 overvoltage category (of a circuit or within an electrical system)
категория перенапряжения (в цепи или электрической системе)
Условное число, основанное на ограничении (или регулировании) значений ожидаемого переходного перенапряжения, возникающего в цепи (или в электрической системе с различными номинальными напряжениями), зависящее от способов воздействия на перенапряжения.
Примечание. В электрической системе переход от одной категории перенапряжения к другой, более низкой, достигается средствами, совместимыми с требованиями к переходным участкам, например с помощью устройства для защиты от перенапряжений или последовательно-параллельного присоединения импеданса, способного рассеять, поглотить или отклонить энергию соответствующего импульсного тока с целью снижения переходного перенапряжения до желательно меньшей категории перенапряжения.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
категория перенапряжения
Категория электротехнического оборудования по стойкости изоляции к импульсным перенапряжениям (всего четыре категории: I, II, III, IV)
[Интент]EN
overvoltage category (of a circuit or within an electrical system)
conventional number based on limiting (or controlling) the values of prospective transient overvoltages occurring in a circuit (or within an electrical system having different nominal voltages) and depending upon the means employed to influence the overvoltages
NOTE In an electrical system, the transition from one overvoltage category to another of lower category is obtained through appropriate means complying with interface requirements, such as an overvoltage protective device or a series-shunt impedance arrangement capable of dissipating, absorbing, or diverting the energy in the associated surge current, to lower the transient overvoltage value to that of the desired lower overvoltage category
[IEC 60947-1, ed. 5.0 (2007-06)]FR
catégorie de surtension (d'un circuit ou dans un réseau)
nombre conventionnel, basé sur la limitation (ou la commande) des valeurs des surtensions transitoires présumées apparaissant dans un circuit (ou dans un réseau où existent des sections de tensions nominales différentes) et dépendant des moyens employés pour agir sur ces surtensions
NOTE Dans un réseau, le passage d'une catégorie de surtension à une autre de catégorie inférieure est réalisé à l'aide de moyens appropriés répondant aux prescriptions d'interface, tels qu'un dispositif de protection contre les surtensions ou des impédances disposées en séries et/ou en parallèle capables de dissiper, d'absorber ou de détourner l'énergie du courant de surcharge correspondant, afin d'abaisser la valeur des surtensions transitoires à celle qui correspond à la catégorie de surtension inférieure recherchée
[IEC 60947-1, ed. 5.0 (2007-06)]Требуемая стойкость к импульсным напряжениям, кВ:
-
Оборудования на вводе в установку ( IV категория перенапряжения)
-
Оборудования распределительных и конечных цепей ( III категория перенапряжения)
-
Электробытовых приборов и электроприемников ( II категория перенапряжения)
-
Специально защищенного оборудования ( I категория перенапряжения)
[ ГОСТ Р 50571-4-44-2011( МЭК 60364-4-44: 2007) ]
Тематики
- электротехника, основные понятия
EN
- overvoltage categories
- overvoltage category (of a circuit or within an electrical system)
- overvoltage withstand categories
- surge voltage category
FR
Англо-русский словарь нормативно-технической терминологии > overvoltage category (of a circuit or within an electrical system)
-
Оборудования на вводе в установку ( IV категория перенапряжения)
-
54 установочный автомат
Большой англо-русский и русско-английский словарь > установочный автомат
-
55 cascading
- резервная защита
- перекрытие по поверхности гирлянды ЛЭП
- каскадный паровой нагрев
- каскадирование
- включение ступенями
включение ступенями
каскадное включение
многошаговый
многоуровневый
каскадный
—
[Л.Г.Суменко. Англо-русский словарь по информационным технологиям. М.: ГП ЦНИИС, 2003.]Тематики
Синонимы
EN
каскадирование
-Параллельные тексты EN-RU
Cascading originates from current-limiting technology.
If limiting breaking/making capacity of a circuit breaker is lower than prospective short-circuit current, it can be installed downstream of a current-limiting circuit breaker so that it can have improved breaking capacity due to current-limiting ability of the upstream circuit breaker.
Cascading technology helps lower cost of downstream switches and accessories.
[Schneider Electric]Принцип каскадирования основан на применении технологии токоограничения.
Если предельная отключающая/включающая способность автоматического выключателя ниже ожидаемого тока короткого замыкания, то его можно установить со стороны нагрузки при условии, что со стороны источника питания установлен токоограничивающий автоматический выключатель. Таким образом, отключающая способность выключателя со стороны нагрузки увеличивается за счет токоограничения выключателя, расположенного со стороны источника питания.Метод каскадирования позволяет применять более дешевые принадлежности и аппараты, включаемые со стороны нагрузки.
[Перевод Интент]Тематики
- выключатель автоматический
- предохранитель
- электротехника, основные понятия
EN
каскадный паровой нагрев
—
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
перекрытие по поверхности гирлянды ЛЭП
—
[А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]Тематики
EN
резервная защита
Координация по сверхтокам двух устройств для защиты от сверхтоков, соединенных последовательно, когда защитное устройство, расположенное, как правило, но необязательно на входной стороне, осуществляет защиту от сверхтока с помощью или без помощи второго защитного устройства, предотвращая его чрезмерную нагрузку.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]Параллельные тексты EN-RU Cascading or back-up protection
This consists of installing an upstream circuit-breaker D1 to help a downstream circuit-breaker D2 to break short-circuit currents greater than its ultimate breaking capacity lcuD2.
This value is marked lcuD2+D1.
Standard IEC 60947-2 recognises cascading between two circuit-breakers.
[Schneider Electric]Резервная защита
Смысл резервной защиты состоит в том, что расположенный выше автоматический выключатель D1 помогает расположенному ниже автоматическому выключателю D2 отключать токи короткого замыкания, превышающие предельную отключающую способность lcuD2.
Это значение обозначают lcuD2+D1.
Координация характеристик двух автоматических выключателей, реализуемая по принципу резервной защиты рассмотрена в стандарте МЭК 60947-2.
[Перевод Интент]
Рис. Schneider ElectricТематики
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > cascading
-
56 cascading method
каскадирование
-Параллельные тексты EN-RU
Cascading originates from current-limiting technology.
If limiting breaking/making capacity of a circuit breaker is lower than prospective short-circuit current, it can be installed downstream of a current-limiting circuit breaker so that it can have improved breaking capacity due to current-limiting ability of the upstream circuit breaker.
Cascading technology helps lower cost of downstream switches and accessories.
[Schneider Electric]Принцип каскадирования основан на применении технологии токоограничения.
Если предельная отключающая/включающая способность автоматического выключателя ниже ожидаемого тока короткого замыкания, то его можно установить со стороны нагрузки при условии, что со стороны источника питания установлен токоограничивающий автоматический выключатель. Таким образом, отключающая способность выключателя со стороны нагрузки увеличивается за счет токоограничения выключателя, расположенного со стороны источника питания.Метод каскадирования позволяет применять более дешевые принадлежности и аппараты, включаемые со стороны нагрузки.
[Перевод Интент]Тематики
- выключатель автоматический
- предохранитель
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > cascading method
-
57 cascading technology
каскадирование
-Параллельные тексты EN-RU
Cascading originates from current-limiting technology.
If limiting breaking/making capacity of a circuit breaker is lower than prospective short-circuit current, it can be installed downstream of a current-limiting circuit breaker so that it can have improved breaking capacity due to current-limiting ability of the upstream circuit breaker.
Cascading technology helps lower cost of downstream switches and accessories.
[Schneider Electric]Принцип каскадирования основан на применении технологии токоограничения.
Если предельная отключающая/включающая способность автоматического выключателя ниже ожидаемого тока короткого замыкания, то его можно установить со стороны нагрузки при условии, что со стороны источника питания установлен токоограничивающий автоматический выключатель. Таким образом, отключающая способность выключателя со стороны нагрузки увеличивается за счет токоограничения выключателя, расположенного со стороны источника питания.Метод каскадирования позволяет применять более дешевые принадлежности и аппараты, включаемые со стороны нагрузки.
[Перевод Интент]Тематики
- выключатель автоматический
- предохранитель
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > cascading technology
-
58 breaker
1) выключатель2) абонент системы персональной радиосвязи, пытающийся передать сообщение по занятому каналу•- automatic reclosing circuit breaker
- automatic tripping circuit breaker
- circuit breaker
- contact breaker
- current limiting circuit breaker
- deion circuit breaker
- double-throw breaker
- double-throw circuit breaker
- field circuit breaker
- gas-blast circuit breaker
- magnetic circuit breaker
- mercury breaker
- oil circuit breaker
- overvoltage tripping circuit breaker
- reverse power tripping circuit breaker
- series overcurrent tripping circuit breaker
- series undercurrent tripping circuit breaker
- shunt tripping circuit breaker
- single-throw breaker
- single-throw circuit breaker
- thermal circuit breaker
- transformer overcurrent tripping circuit breaker
- transformer undercurrent tripping circuit breaker
- trip-free circuit breaker
- undervoltage tripping circuit breaker -
59 breaker
1) выключатель2) абонент системы персональной радиосвязи, пытающийся передать сообщение по занятому каналу•- automatic reclosing circuit breaker
- automatic tripping circuit breaker
- circuit breaker
- contact breaker
- current limiting circuit breaker
- deion circuit breaker
- double-throw breaker
- double-throw circuit breaker
- field circuit breaker
- gas-blast circuit breaker
- magnetic circuit breaker
- mercury breaker
- oil circuit breaker
- overvoltage tripping circuit breaker
- reverse power tripping circuit breaker
- series overcurrent tripping circuit breaker
- series undercurrent tripping circuit breaker
- shunt tripping circuit breaker
- single-throw breaker
- single-throw circuit breaker
- thermal circuit breaker
- transformer overcurrent tripping circuit breaker
- transformer undercurrent tripping circuit breaker
- trip-free circuit breaker
- undervoltage tripping circuit breakerThe New English-Russian Dictionary of Radio-electronics > breaker
-
60 breaker
1) = crusher дробилка, дробильная установка2) машинист дробилки; отбойщик; отбойный шпур; обогатительная фабрика; прерыватель, выключатель; разрезной шпур, врубовой шпур; измельчитель; лом; размыкатель•
- bit breaker
- cake breaker
- circuit breaker
- coal breaker
- concrete breaker
- contact breaker
- continuous breaker
- core breaker
- curcuit breaker
- current-limiting circuit
- duplex breaker
- emergency breaker
- fused breaker
- gyratory breaker
- gyratory cone breaker
- hammer breaker
- jaw breaker
- pavement breaker
- paving breaker
- pick breaker
- pin breaker
- preliminary breaker
- primary breaker
- reciprocating breaker
- rock breaker
- roll breaker
- spindle breaker
- stone breaker
См. также в других словарях:
current-limiting circuit breaker — ribinės srovės išjungiklis statusas T sritis radioelektronika atitikmenys: angl. current limiting circuit breaker vok. Strombegrenzungsschalter, m rus. токоограничивающий выключатель, m pranc. disjoncteur limiteur de courant, m … Radioelektronikos terminų žodynas
Current limiting — is the practice in electrical or electronic circuits of imposing an upper limit on the current that may be delivered to a load with the purpose of protecting the circuit generating or transmitting the current from harmful effects due to a short… … Wikipedia
current-limiting reactor — ˈ ̷ ̷ ̷ ̷ˌ ̷ ̷ ̷ ̷ ̷ ̷ noun : an electrical inductance made up of a number of turns of wire of low ohmic resistance and inserted in series with a line to limit the current that can flow under short circuit … Useful english dictionary
Current source — Figure 1: An ideal current source, I, driving a resistor, R, and creating a voltage V A current source is an electrical or electronic device that delivers or absorbs electric current. A current source is the dual of a voltage source. The term… … Wikipedia
Circuit total limitation — (CTL) is one of the present day standards for electrical panels sold in the United States according to the National Electrical Code. The 1965 edition of the NEC, article 384 15 was the first reference to the circuit total limitation of… … Wikipedia
Current mirror — A current mirror is a circuit designed to copy a current through one active device by controlling the current in another active device of a circuit, keeping the output current constant regardless of loading. The current being copied can be, and… … Wikipedia
Circuit de la Sarthe — For the French road bicycle racing stage race, see Circuit de la Sarthe (cycling) Circuit des 24 Heures Circuit de la Sarthe Location Le Mans, France … Wikipedia
Constant current diode — Circuit Constant current diode (also called CLD, current limiting diode, constant current diode, diode connected transistor or CRD,current regulating diode) consists of a JFET with the gate shorted to the source, and it functions like a two… … Wikipedia
current limiter — noun : a fuse to break a circuit when a predetermined current is exceeded * * * Elect. a device, as a resistor or fuse, that limits the flow of current to a prescribed amount, independent of the voltage applied. * * * current limiter, an… … Useful english dictionary
LED circuit — In electronics, the basic LED circuit is an electrical circuit used to power a light emitting diode (LED). It consists of up to four components connected in series: a voltage source, a current limiting resistor, an LED, and optionally a switch to … Wikipedia
Inrush current limiter — An inrush current limiter is a component used to limit inrush current. Negative temperature coefficient (NTC) thermistors and fixed resistors are often used for this. Less often, other components are also used.The inrush current limiter is placed … Wikipedia