  • 1 tension assignée d'un parafoudre

    1. номинальное напряжение ОПН

     

    номинальное напряжение

    Действующее значение напряжения промышленной частоты, которое ограничитель может выдерживать в течение 10 с в процессе рабочих испытаний. Номинальное напряжение должно быть не менее 1,25 наибольшего длительно допустимого рабочего напряжения.
    [ ГОСТ Р 52725-2007]

    EN

    rated voltage of an arrester
    Ur

    maximum permissible r.m.s. value of power-frequency voltage between its terminals at which it is designed to operate correctly under temporary overvoltage conditions as established in the operating duty tests
    NOTE 1 The rated voltage is used as a reference parameter for the specification of operating characteristics.
    NOTE 2 The rated voltage as defined in this standard is the 10 s power-frequency voltage used in the operating duty test after high-current or long-duration impulses. Tests used to establish the voltage rating in IEC 60099-1, as well as some national standards, involve the application of repetitive impulses at nominal current with power-frequency voltage applied. Attention is drawn to the fact that these two methods used to established rating do not necessarily produce equivalent values (a resolution to this discrepancy is under consideration).
    [IEC 60099-4, ed. 2.0 (2004-05)]

    FR

    tension assignée d'un parafoudre
    Ur

    valeur maximale de la tension efficace à fréquence industrielle admissible entre ses bornes pour laquelle le parafoudre est prévu pour fonctionner correctement dans des conditions de surtension temporaires comme il est défini dans les essais de fonctionnement
    NOTE 1 La tension assignée est utilisée comme paramètre de référence pour la spécification des caractéristiques de fonctionnement.
    NOTE 2 La tension assignée comme définie dans la présente norme est la tension à fréquence industrielle de 10 s, utilisée pour vérifier la stabilité après application des chocs de courant de grande amplitude ou de longue durée lors de l'essai de fonctionnement. Les essais utilisés pour définir la tension assignée dans la CEI 60099-1, ainsi que dans certaines normes nationales, impliquent l'application de chocs répétés au courant nominal pendant que la tension à fréquence industrielle est appliquée. On attire l'attention sur le fait que ces deux méthodes utilisées pour définir les valeurs assignées ne produisent pas nécessairement des valeurs équivalentes (une résolution de cette différence est à l'étude).
    [IEC 60099-4, ed. 2.0 (2004-05)]

    Тематики

    • высоковольтный аппарат, оборудование...

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > tension assignée d'un parafoudre

  • 2 installation de distribution

    1. распределительное устройство

     

    распределительное устройство
    Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [РД 34.20.185-94]

    распределительное устройство

    Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
    Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
    [ ГОСТ 24291-90]
    [ ГОСТ Р 53685-2009]

    электрическое распределительное устройство
    распределительное устройство
    Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
    Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
    [ОСТ 45.55-99]

    распределительное устройство
    Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [ПОТ Р М-016-2001]
    [РД 153-34.0-03.150-00]

    устройство распределительное
    Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    EN

    switching substation
    a substation which includes switchgear and usually busbars, but no power transformers
    [IEV number 605-01-02]

    FR

    poste de sectionnement
    poste de coupure

    poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
    [IEV number 605-01-02]

    В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
    На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]


    КЛАССИФИКАЦИЯ

    В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:

    • по назначению:
      • генерирующие,
      • преобразовательно-распределительные,
      • потребительские.

        Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;

     Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласно ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:

    для электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
    для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.

    Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.

    Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.

    Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.

    Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.

    • по способу управления ПС могут быть:
      • только с телесигнализацией,
      • телеуправляемыми с телесигнализацией,
      • с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).


    Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.

    В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.

    В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
     



    Several different classifications of switchgear can be made:

    A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.

    Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.

    [Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
    [ http://en.wikipedia.org/wiki/High_voltage_switchgear]

    Тематики

    Синонимы

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > installation de distribution

  • 3 poste de commutation

    1. распределительное устройство

     

    распределительное устройство
    Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [РД 34.20.185-94]

    распределительное устройство

    Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
    Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
    [ ГОСТ 24291-90]
    [ ГОСТ Р 53685-2009]

    электрическое распределительное устройство
    распределительное устройство
    Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
    Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
    [ОСТ 45.55-99]

    распределительное устройство
    Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [ПОТ Р М-016-2001]
    [РД 153-34.0-03.150-00]

    устройство распределительное
    Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    EN

    switching substation
    a substation which includes switchgear and usually busbars, but no power transformers
    [IEV number 605-01-02]

    FR

    poste de sectionnement
    poste de coupure

    poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
    [IEV number 605-01-02]

    В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
    На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]


    КЛАССИФИКАЦИЯ

    В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:

    • по назначению:
      • генерирующие,
      • преобразовательно-распределительные,
      • потребительские.

        Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;

     Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласно ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:

    для электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
    для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.

    Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.

    Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.

    Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.

    Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.

    • по способу управления ПС могут быть:
      • только с телесигнализацией,
      • телеуправляемыми с телесигнализацией,
      • с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).


    Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.

    В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.

    В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
     



    Several different classifications of switchgear can be made:

    A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.

    Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.

    [Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
    [ http://en.wikipedia.org/wiki/High_voltage_switchgear]

    Тематики

    Синонимы

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > poste de commutation

  • 4 poste de coupure

    1. распределительное устройство

     

    распределительное устройство
    Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [РД 34.20.185-94]

    распределительное устройство

    Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
    Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
    [ ГОСТ 24291-90]
    [ ГОСТ Р 53685-2009]

    электрическое распределительное устройство
    распределительное устройство
    Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
    Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
    [ОСТ 45.55-99]

    распределительное устройство
    Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [ПОТ Р М-016-2001]
    [РД 153-34.0-03.150-00]

    устройство распределительное
    Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    EN

    switching substation
    a substation which includes switchgear and usually busbars, but no power transformers
    [IEV number 605-01-02]

    FR

    poste de sectionnement
    poste de coupure

    poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
    [IEV number 605-01-02]

    В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
    На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]


    КЛАССИФИКАЦИЯ

    В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:

    • по назначению:
      • генерирующие,
      • преобразовательно-распределительные,
      • потребительские.

        Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;

     Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласно ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:

    для электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
    для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.

    Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.

    Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.

    Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.

    Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.

    • по способу управления ПС могут быть:
      • только с телесигнализацией,
      • телеуправляемыми с телесигнализацией,
      • с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).


    Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.

    В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.

    В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
     



    Several different classifications of switchgear can be made:

    A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.

    Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.

    [Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
    [ http://en.wikipedia.org/wiki/High_voltage_switchgear]

    Тематики

    Синонимы

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > poste de coupure

  • 5 poste de sectionnement

    1. распределительное устройство

     

    распределительное устройство
    Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [РД 34.20.185-94]

    распределительное устройство

    Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
    Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
    [ ГОСТ 24291-90]
    [ ГОСТ Р 53685-2009]

    электрическое распределительное устройство
    распределительное устройство
    Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
    Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
    [ОСТ 45.55-99]

    распределительное устройство
    Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
    [ПОТ Р М-016-2001]
    [РД 153-34.0-03.150-00]

    устройство распределительное
    Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    EN

    switching substation
    a substation which includes switchgear and usually busbars, but no power transformers
    [IEV number 605-01-02]

    FR

    poste de sectionnement
    poste de coupure

    poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
    [IEV number 605-01-02]

    В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
    На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]


    КЛАССИФИКАЦИЯ

    В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:

    • по назначению:
      • генерирующие,
      • преобразовательно-распределительные,
      • потребительские.

        Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;

     Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласно ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:

    для электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
    для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.

    Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.

    Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.

    Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.

    Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.

    • по способу управления ПС могут быть:
      • только с телесигнализацией,
      • телеуправляемыми с телесигнализацией,
      • с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).


    Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.

    В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.

    В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.

    [ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
     



    Several different classifications of switchgear can be made:

    A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.

    Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.

    [Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
    [ http://en.wikipedia.org/wiki/High_voltage_switchgear]

    Тематики

    Синонимы

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > poste de sectionnement

  • 6 démarrage direct

    1. прямой пуск вращающегося электродвигателя

     

    прямой пуск вращающегося электродвигателя
    Пуск вращающегося электродвигателя путем непосредственного подключения его к питающей сети.
    [ ГОСТ 27471-87]

    EN

    direct-on-line starting
    across-the-line starting (US)
    the process of starting a motor by connecting it directly to the supply at rated voltage
    [IEV number 411-52-15]

    FR

    démarrage direct
    mode de démarrage d'un moteur, consistant à lui appliquer directement sa pleine tension assignée
    [IEV number 411-52-15]

    0855
    Рис. ABB
    Схема прямого пуска электродвигателя

    Magnetic only circuit-breaker - Автоматический выключатель с электромагнитным расцепителем

    Contactor KL - Контактор KL

    Thermal relay - Тепловое реле

     

    Параллельные тексты EN-RU

    Direct-on-line starting

    Direct-on-line starting, which is often abbreviated as DOL, is perhaps the most traditional system and consists in connecting the motor directly to the supply network, thus carrying out starting at full voltage.

    Direct-on-line starting represents the simplest and the most economical system to start a squirrel-cage asynchronous motor and it is the most used.

    As represented in Figure 5, it provides the direct connection to the supply network and therefore starting is carried out at full voltage and with constant frequency, developing a high starting torque with very reduced acceleration times.

    The typical applications are relevant to small power motors also with full load starting.

    These advantages are linked to some problems such as, for example, the high inrush current, which - in the first instants - can reach values of about 10 to 12 times the rated current, then can decrease to about 6 to 8 times the rated current and can persist to reach the maximum torque speed.

    The effects of such currents can be identified with the high electro-dynamical stresses on the motor connection cables and could affect also the windings of the motor itself; besides, the high inrush torques can cause violent accelerations which stress the transmission components (belts and joints) generating distribution problems with a reduction in the mechanical life of these elements.

    Finally, also the possible electrical problems due to voltage drops on the supply line of the motor or of the connected equipment must be taken into consideration.
    [ABB]

    Прямой пуск

    Прямой пуск, который по-английски часто сокращенно обозначают как DOL, является, пожалуй наиболее распространенным способом пуска. Он заключается в непосредственном (т. е. прямом) подключении двигателя к питающей сети. Это означает, что пуск двигателя осуществляется при полном напряжении.

    Схема прямого пуска является наиболее простым, экономичным и чаще всего применяемым решением для электродвигателей с короткозамкнутым ротором.

    Схема прямого подключения к сети представлена на рисунке 5. Пуск осуществляется при полном напряжении и постоянной частоте сети. Электродвигатель развивает высокий пусковой момент при коротком времени разгона.

    Типичные области применения – маломощные электродвигатели, в том числе с пуском при полной нагрузке.

    Однако, наряду с преимуществами имеются и определенные недостатки, например, бросок пускового тока, достигающий в первоначальный момент 10…12-кратного значения от номинального тока электродвигателя. Затем ток двигателя уменьшается примерно до 6…8-кратного значения номинального тока и будет держаться на этом уровне до тех пор, пока скорость двигателя не достигнет максимального значения.

    Такое изменение тока оказывает значительное электродинамическое воздействие на кабель, подключенный к двигателю. Кроме того пусковой ток воздействует на обмотки двигателя. Высокий начальный пусковой момент может привести к значительному ускорению и следовательно к значительной нагрузке элементов привода (ремней, крепления узлов), что вызывает сокращение их срока службы.

    И, наконец, следует принять во внимание возможное возникновение проблем, связанных с падением напряжения в линии питания двигателя и подключенного к этой линии оборудования.
    [Перевод Интент]




     

    Тематики

    Синонимы

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > démarrage direct

  • 7 durée d'ouverture (d'un appareil mécanique de connexion)

    1. собственное время отключения
    2. время размыкания (контактного коммутационного аппарата)

     

    время размыкания (контактного коммутационного аппарата)
    Интервал времени между установленным начальным моментом размыкания и моментом разъединения дугогасительных контактов во всех полюсах.
    МЭК 60050 (441-17-36).
    Примечание.  Начальный момент размыкания (например подача сигнала к размыканию на расцепитель и т. п.), устанавливается в стандарте на соответствующий аппарат.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    EN

    opening time (of a mechanical switching device)
    the interval of time between the specified instant of initiation of the opening operation and the instant when the arcing contacts have separated in all poles
    NOTE – The instant of initiation of the opening operation, i.e. the application of the opening command (e.g. energizing the release, etc.) is given in the relevant specifications.
    [IEV number 441-17-36]

    FR

    durée d'ouverture (d'un appareil mécanique de connexion)
    intervalle de temps entre l'instant spécifié de début de la manoeuvre d'ouverture et l'instant de la séparation des contacts d'arc sur tous les pôles
    NOTE – L'instant de début de la manoeuvre d'ouverture, c'est-à-dire l'émission de l'ordre d'ouverture (par exemple l'alimentation d'un déclencheur, etc.) est donné dans les spécifications particulières.
    [IEV number 441-17-36]

     

    Тематики

    • аппарат, изделие, устройство...

    EN

    DE

    FR

     

    собственное время отключения
    Собственным временем отключения называется интервал времени от момента подачи команды на отключение до момента прекращения соприкосновения (размыкания) дугогасительных контактов (для выключателей с шунтирующими резисторами следует различать время до момента прекращения соприкос-
    новения основных дугогасительных контактов и то же – для дугогасительных контактов шунтирующей цепи).
    Нормированное собственное время отключения выключателя принимается равным измеренному при отсутствии токовой нагрузки в главной цепи выключателя и при номинальном напряжении питания цепи управления.
    Собственное время отключения заключает в себе время оперирования любого вспомогательного оборудования, необходимого для отключения выключателя и являющегося его неотъемлемой частью.
    [IX Симпозиум «ЭЛЕКТРОТЕХНИКА 2030», доклад 4.53. 29 – 31 мая 2007 года]

    собственное время отключения
    to.c
    Интервал времени от момента подачи команды на отключение до момента прекращения соприкосновения (размыкания) дугогасительных контактов (для выключателей с шунтирующими резисторами следует различать время до момента прекращения соприкосновения основных дугогасительных контактов и то же - для дугогасительных контактов шунтирующей цепи).
    Собственное время отключения выключателя определяется в соответствии со способом отключения, как установлено ниже, и с любым устройством выдержки времени, являющимся неотъемлемой частью выключателя, установленным на свою минимальную регулировку:
    а) для выключателей, отключающих с помощью любой формы вспомогательной энергии, собственное время отключения представляет интервал времени между моментом подачи команды на катушку отключения или расцепитель выключателя, находящегося во включенном положении, и моментом, когда дугогасительные контакты разомкнутся во всех полюсах;
    б) для самоотключающегося выключателя собственное время отключения представляет интервал времени между моментом, при котором ток в главной цепи выключателя, находящегося во включенном положении, достигает значения срабатывания расцепителя максимального тока, и моментом, когда дугогасительные контакты разомкнутся во всех полюсах.
    Нормированное собственное время отключения выключателя принимается равным измеренному при отсутствии токовой нагрузки в главной цепи выключателя и при номинальном напряжении питания цепи управления.
    Для воздушных выключателей и для выключателей других видов с пневматическими приводами это время принимается равным измеренному при номинальном давлении воздуха.
    Примечания
    1 Собственное время отключения может изменяться в зависимости от значения отключаемого тока.
    2 Для многоразрывных выключателей момент, когда дугогасительные контакты разомкнутся во всех полюсах, определяется как момент размыкания контактов первого (по времени) разрыва полюса, размыкающегося последним.
    3 Собственное время отключения содержит в себе время оперирования любого вспомогательного оборудования, необходимого для отключения выключателя и являющегося его неотъемлемой частью.
    [ ГОСТ Р 52565-2006]

    EN

    opening time (of a mechanical switching device)
    the interval of time between the specified instant of initiation of the opening operation and the instant when the arcing contacts have separated in all poles
    NOTE – The instant of initiation of the opening operation, i.e. the application of the opening command (e.g. energizing the release, etc.) is given in the relevant specifications.
    [IEV number 441-17-36]

    FR

    durée d'ouverture (d'un appareil mécanique de connexion)
    intervalle de temps entre l'instant spécifié de début de la manoeuvre d'ouverture et l'instant de la séparation des contacts d'arc sur tous les pôles
    NOTE – L'instant de début de la manoeuvre d'ouverture, c'est-à-dire l'émission de l'ordre d'ouverture (par exemple l'alimentation d'un déclencheur, etc.) est donné dans les spécifications particulières.
    [IEV number 441-17-36]

    См. также полное время отключения

    Коммутационный цикл

    0732_1

    Параллельные тексты EN-RU

    1

    Breaker closed - apply auxillary power to activate the release.

    Выключатель во включенном положении. Начинает прикладываться внешнее усилие, направленное на отключение.

    2

    Contact separation - start of arc.

    Наличие зазора между разомкнутыми контактами. Возникновение дуги.

    3

    Extinction of arc.

    Погасание дуги.

    4

    Breacer open - initiation of closing movement.

    Выключатель в отключенном положении. Инициирование включения.

    5

    Current starts to flow in the conducting path (preignition)

    Начало протекания тока (начало горения дуги в изоляционном промежутке между разомкнутыми контактами).

    6

    Contact touch.

    Соприкосновение контактов.

    -

    Opening time.

    Собственное время отключения.

    -

    Arcing time

    Время дуги.

    -

    Make time.

    Время включения.

    -

    Break time/Interrupting time

    Полное время отключения

    -

    Dead time.

    Бестоковая пауза.

    -

    Closing time.

    Собственное время включения.

    -

    Reclosing time.

    Цикл автоматического повторного включения.

     

    [Siemens]

    [Перевод Интент]

    Тематики

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > durée d'ouverture (d'un appareil mécanique de connexion)

  • 8 tableau de répartition, m

    1. распределительный щит
    2. распределительная панель

     

    распределительная панель
    НКУ, состоящее из коммутационных устройств или устройств защиты (например, плавких предохранителей), присоединенных к одной или нескольким выходным цепям с питанием от одной или нескольких входящих цепей, а также зажимов для нейтрального проводника и проводников цепей защиты. Оно может также содержать сигнальные устройства и другие устройства контроля.
    [ ГОСТ Р 51321. 3-99 ( МЭК 60439-3-90)]


    панель распределительная
    Панель многопанельного ВРУ, содержащая аппараты блока(ов) распределения и в которой могут также размещаться блоки учета, блоки автоматического или неавтоматического управления освещением и т. п.
    [ ГОСТ Р 51732-2001]

    EN

    distribution board
    assembly containing different types of switchgear and controlgear associated with one or more outgoing electric circuits fed from one or more incoming electric circuits, together with terminals for the neutral and protective conductors.
    [IEV number 826-16-08]

    FR

    tableau de répartition, m
    ensemble comportant différents types d'appareillage associés à un ou plusieurs circuits électriques de départ alimentés par un ou plusieurs circuits électriques d'arrivée, ainsi que des bornes pour les conducteurs neutre et de protection.
    [IEV number 826-16-08]

     

     

    распределительная панель
    -

    EN

    distribution board
    an assembly of one or more overcurrent protective devices, arranged for the distribution of electrical power to final subcircuits
    [IEC 60092-101, ed. 4.0 (1994-10)]

    FR

    panneau de distribution
    ensemble comprenant un ou plusieurs dispositifs de protection contre les surintensités et assurant la distribution d'énergie électrique à des circuits terminaux
    [IEC 60092-101, ed. 4.0 (1994-10)]

    Тематики

    EN

    DE

    • elektrischer Verteiler, m
    • Verteiler, m

    FR

     

    распределительный щит
    Комплектное устройство, содержащее различную коммутационную аппаратуру, соединенное с одной или более отходящими электрическими цепями, питающееся от одной или более входящих цепей, вместе с зажимами для присоединения нейтральных и защитных проводников.
    [ ГОСТ Р МЭК 60050-826-2009]

    щит распределительный
    Электротехническое устройство, объединяющее коммутационную, регулирующую и защитную аппаратуру, а также контрольно-измерительные и сигнальные приборы
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    распределительный щит

    [А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]

    EN

    distribution board
    assembly containing different types of switchgear and controlgear associated with one or more outgoing electric circuits fed from one or more incoming electric circuits, together with terminals for the neutral and protective conductors.
    [IEV number 826-16-08]

    FR

    tableau de répartition, m
    ensemble comportant différents types d'appareillage associés à un ou plusieurs circuits électriques de départ alimentés par un ou plusieurs circuits électriques d'arrivée, ainsi que des bornes pour les conducteurs neutre et de protection.
    [IEV number 826-16-08]

    Параллельные тексты EN-RU

    Distribution switchboards, including the Main LV Switchboard (MLVS), are critical to the dependability of an electrical installation. They must comply with well-defined standards governing the design and construction of LV switchgear assemblies

    A distribution switchboard is the point at which an incoming-power supply divides into separate circuits, each of which is controlled and protected by the fuses or switchgear of the switchboard. A distribution switchboard is divided into a number of functional units, each comprising all the electrical and mechanical elements that contribute to the fulfilment of a given function. It represents a key link in the dependability chain.

    Consequently, the type of distribution switchboard must be perfectly adapted to its application. Its design and construction must comply with applicable standards and working practises.

    [Schneider Electric]

    Распределительные щиты, включая главный распределительный щит низкого напряжения (ГРЩ), играют решающую роль в обеспечении надежности электроустановки. Они должны отвечать требованиям соответствующих стандартов, определяющих конструкцию и порядок изготовления НКУ распределения электроэнергии.

    В распределительном щите выполняется прием электроэнергии и ее распределение по отдельным цепям, каждая из которых контролируется и защищается плавкими предохранителями или автоматическими выключателями.
    Распределительный щит состоит из функциональных блоков, включающих в себя все электрические и механические элементы, необходимые для выполнения требуемой функции. Распределительный щит представляет собой ключевое звено в цепи обеспечения надежности.

    Тип распределительного щита должен соответствовать области применения. Конструкция и изготовление распределительного щита должны удовлетворять требованиям применимых стандартов и учитывать накопленную практику применения.

    [Перевод Интент]

     

    5654

    Рис. Schneider Electric

    With Prisma Plus G you can be sure to build 100% Schneider Electric switchboards that are safe, optimised:

    > All components (switchgear, distribution blocks, prefabricated connections, etc.) are perfectly rated and coordinated to work together;

    > All switchboard configurations, even the most demanding ones, have been tested.

    You can prove that your switchboard meets the current standards, at any time.

    You can be sure to build a reliable electrical installation and give your customers full satisfaction in terms of dependability and safety for people and the installation.

    Prisma Plus G with its discreet design, blends harmoniously into all tertiary and industrial buildings, including in entrance halls and passageways.

    With Prisma Plus G you can build just the right switchboard for your customer, sized precisely to fit costs and needs.

    With this complete, prefabricated and tested system, it's easy to upgrade your installation and still maintain the performance levels.

    > The wall-mounted and floor-standing enclosures combine easily with switchboards already in service.

    > Devices can be replaced or added at any time.

    [Schneider Electric]

    С помощью оболочек Prisma Plus G можно создавать безопасные распределительные щиты, на 100 % состоящие из изделий Schneider Electric:

    > все изделия (коммутационная аппаратура, распределительные блоки, готовые заводские соединения и т. д.) полностью совместимы механически и электрически;

    > все варианты компоновки распределительных щитов, в том числе для наиболее ответственных применений, прошли испытания.

    В любое время вы можете доказать, что ваши распределительные щиты полностью соответствуют требованиям действующих стандартов.

    Вы можете быть полностью уверены в том, что создаете надежные электроустановки, удовлетворяющие всем требованиям безопасности для людей и оборудования

    Благодаря строгому дизайну, распределительные щиты Prisma Plus G гармонично сочетаются с интерьером любого общественного или промышленного здания. Они хорошо смотрятся и в вестибюле, и в коридоре.

    Применяя оболочки Prisma Plus G можно создавать распределительные щиты, точно соответствующие требованиям заказчика как с точки зрения технических характеристик, так и стоимости.

    С помощью данной испытанной системы, содержащей все необходимые компоненты заводского изготовления можно легко модернизировать существующую электроустановку и поддерживать её уровни производительности.

    > Навесные и напольные оболочки можно легко присоединить к уже эксплуатируемым распределительным щитам.

    > Аппаратуру можно заменять или добавлять в любое время.

    [Перевод Интент]

     

    The switchboard, central to the electrical installation.

    Both the point of arrival of energy and a device for distribution to the site applications, the LV switchboard is the intelligence of the system, central to the electrical installation.

    [Schneider Electric]

    Распределительный щит – «сердце» электроустановки.

    Низковольтное комплектное устройство распределения является «сердцем» электроустановки, поскольку именно оно принимает электроэнергию из сети и распределяет её по территориально распределенным нагрузкам.

    [Перевод Интент]

    Тематики

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > tableau de répartition, m

  • 9 tableau de distribution

    1. распределительный щит

     

    распределительный щит
    Комплектное устройство, содержащее различную коммутационную аппаратуру, соединенное с одной или более отходящими электрическими цепями, питающееся от одной или более входящих цепей, вместе с зажимами для присоединения нейтральных и защитных проводников.
    [ ГОСТ Р МЭК 60050-826-2009]

    щит распределительный
    Электротехническое устройство, объединяющее коммутационную, регулирующую и защитную аппаратуру, а также контрольно-измерительные и сигнальные приборы
    [Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]

    распределительный щит

    [А.С.Гольдберг. Англо-русский энергетический словарь. 2006 г.]

    EN

    distribution board
    assembly containing different types of switchgear and controlgear associated with one or more outgoing electric circuits fed from one or more incoming electric circuits, together with terminals for the neutral and protective conductors.
    [IEV number 826-16-08]

    FR

    tableau de répartition, m
    ensemble comportant différents types d'appareillage associés à un ou plusieurs circuits électriques de départ alimentés par un ou plusieurs circuits électriques d'arrivée, ainsi que des bornes pour les conducteurs neutre et de protection.
    [IEV number 826-16-08]

    Параллельные тексты EN-RU

    Distribution switchboards, including the Main LV Switchboard (MLVS), are critical to the dependability of an electrical installation. They must comply with well-defined standards governing the design and construction of LV switchgear assemblies

    A distribution switchboard is the point at which an incoming-power supply divides into separate circuits, each of which is controlled and protected by the fuses or switchgear of the switchboard. A distribution switchboard is divided into a number of functional units, each comprising all the electrical and mechanical elements that contribute to the fulfilment of a given function. It represents a key link in the dependability chain.

    Consequently, the type of distribution switchboard must be perfectly adapted to its application. Its design and construction must comply with applicable standards and working practises.

    [Schneider Electric]

    Распределительные щиты, включая главный распределительный щит низкого напряжения (ГРЩ), играют решающую роль в обеспечении надежности электроустановки. Они должны отвечать требованиям соответствующих стандартов, определяющих конструкцию и порядок изготовления НКУ распределения электроэнергии.

    В распределительном щите выполняется прием электроэнергии и ее распределение по отдельным цепям, каждая из которых контролируется и защищается плавкими предохранителями или автоматическими выключателями.
    Распределительный щит состоит из функциональных блоков, включающих в себя все электрические и механические элементы, необходимые для выполнения требуемой функции. Распределительный щит представляет собой ключевое звено в цепи обеспечения надежности.

    Тип распределительного щита должен соответствовать области применения. Конструкция и изготовление распределительного щита должны удовлетворять требованиям применимых стандартов и учитывать накопленную практику применения.

    [Перевод Интент]

     

    5654

    Рис. Schneider Electric

    With Prisma Plus G you can be sure to build 100% Schneider Electric switchboards that are safe, optimised:

    > All components (switchgear, distribution blocks, prefabricated connections, etc.) are perfectly rated and coordinated to work together;

    > All switchboard configurations, even the most demanding ones, have been tested.

    You can prove that your switchboard meets the current standards, at any time.

    You can be sure to build a reliable electrical installation and give your customers full satisfaction in terms of dependability and safety for people and the installation.

    Prisma Plus G with its discreet design, blends harmoniously into all tertiary and industrial buildings, including in entrance halls and passageways.

    With Prisma Plus G you can build just the right switchboard for your customer, sized precisely to fit costs and needs.

    With this complete, prefabricated and tested system, it's easy to upgrade your installation and still maintain the performance levels.

    > The wall-mounted and floor-standing enclosures combine easily with switchboards already in service.

    > Devices can be replaced or added at any time.

    [Schneider Electric]

    С помощью оболочек Prisma Plus G можно создавать безопасные распределительные щиты, на 100 % состоящие из изделий Schneider Electric:

    > все изделия (коммутационная аппаратура, распределительные блоки, готовые заводские соединения и т. д.) полностью совместимы механически и электрически;

    > все варианты компоновки распределительных щитов, в том числе для наиболее ответственных применений, прошли испытания.

    В любое время вы можете доказать, что ваши распределительные щиты полностью соответствуют требованиям действующих стандартов.

    Вы можете быть полностью уверены в том, что создаете надежные электроустановки, удовлетворяющие всем требованиям безопасности для людей и оборудования

    Благодаря строгому дизайну, распределительные щиты Prisma Plus G гармонично сочетаются с интерьером любого общественного или промышленного здания. Они хорошо смотрятся и в вестибюле, и в коридоре.

    Применяя оболочки Prisma Plus G можно создавать распределительные щиты, точно соответствующие требованиям заказчика как с точки зрения технических характеристик, так и стоимости.

    С помощью данной испытанной системы, содержащей все необходимые компоненты заводского изготовления можно легко модернизировать существующую электроустановку и поддерживать её уровни производительности.

    > Навесные и напольные оболочки можно легко присоединить к уже эксплуатируемым распределительным щитам.

    > Аппаратуру можно заменять или добавлять в любое время.

    [Перевод Интент]

     

    The switchboard, central to the electrical installation.

    Both the point of arrival of energy and a device for distribution to the site applications, the LV switchboard is the intelligence of the system, central to the electrical installation.

    [Schneider Electric]

    Распределительный щит – «сердце» электроустановки.

    Низковольтное комплектное устройство распределения является «сердцем» электроустановки, поскольку именно оно принимает электроэнергию из сети и распределяет её по территориально распределенным нагрузкам.

    [Перевод Интент]

    Тематики

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > tableau de distribution

См. также в других словарях:

  • Application checkpointing — Checkpointing is a technique for inserting fault tolerance into computing systems. It basically consists of storing a snapshot of the current application state, and later on, use it for restarting the execution in case of failure. Contents 1… …   Wikipedia

  • Application Enhancer — (APE) is a software program released by Unsanity for Apple s Mac OS X operating system. Application Enhancer provides a framework that allows third party developers to write haxies for OS X. It also provides a daemon to load haxies when certain… …   Wikipedia

  • Application lifecycle management — (ALM) regards the process of delivering software as a continuously repeating cycle of inter related steps: definition, design, development, testing, deployment and management. Each of these steps needs to be carefully monitored and controlled.… …   Wikipedia

  • Current use — is a phrase used to describe the present condition of land use and corresponding scheme for property tax incentives for qualifying land owners (typically rural) who wish to preserve open space and avoid having their property assessed at the best… …   Wikipedia

  • Current-to-voltage converter — In electronics, a transimpedance amplifier is an amplifier that converts current to voltage. Its input ideally has zero impedance, and the input signal is a current. Its output may have low impedance, or in high frequency applications, may be… …   Wikipedia

  • Current injection technique — The current injection technique is a technique developed to reduce the turn OFF switching transient of power bipolar semiconductor devices. It was developed and published by Dr S. Eio of Staffordshire University (United Kingdom) in 2007.… …   Wikipedia

  • Application delivery network — An Application Delivery Network (ADN) is a suite of technologies that, when deployed together, provide application availability, security, and acceleration. At the core of an ADN is the Application Delivery Controller (ADC), an advanced traffic… …   Wikipedia

  • Current loop — This article is about the electrical signaling schemes. For the oceanic phenomenon, see Loop current. A current loop describes two different electrical signalling schemes. Contents 1 Digital 2 Analog 3 Process control use …   Wikipedia

  • Current transformer — A CT for operation on a 110 kV grid In electrical engineering, a current transformer (CT) is used for measurement of electric currents. Current transformers, together with voltage transformers (VT) (potential transformers (PT)), are known as …   Wikipedia

  • Current density — This page is about the electric current density in electromagnetism. For the probability current density in quantum mechanics, see Probability current. Current density is a measure of the density of flow of a conserved charge. Usually the charge… …   Wikipedia

  • Current liability — Accountancy Key concepts Accountant · Accounting period · Bookkeeping · Cash and accrual basis · Cash flow management · Chart of accounts  …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»