21 réducteur de courant
трансформатор тока
Трансформатор, в котором при нормальных условиях применения вторичный ток практически пропорционален первичному току и при правильном включении сдвинут относительно него по фазе на угол, близкий к нулю.
[ ГОСТ 18685-73]
трансформатор тока
Трансформатор, сигнал на выходе которого пропорционален входному току. [МЭС 321-02-01, измененный ]
Примечание
Катушка Роговского с интегрирующей цепью представляет собой широкополосный трансформатор тока.
[МЭК 60-2]EN
current transformer
an instrument transformer in which the secondary current, in normal conditions of use, is substantially proportional to the primary current and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections
[IEV number 321-02-01]FR
transformateur de courant
transformateur de mesure dans lequel le courant secondaire est, dans les conditions normales d'emploi, pratiquement proportionnel au courant primaire et déphasé par rapport à celui-ci d'un angle approximativement nul pour un sens approprié des connexions
[IEV number 321-02-01]... электромагнитные трансформаторы тока (далее — трансформаторы) на номинальное напряжение от 0,66 до 750 кВ включительно, предназначенные для передачи сигнала измерительной информации приборам измерения, защиты, автоматики, сигнализации и управления в электрических цепях переменного тока частотой 50 или 60 Гц.
[ ГОСТ 7746-2001]Параллельные тексты EN-RU
Inductive current transformers (CT) step the operating currents and short-circuit currents down to values which are suitable for measuring instruments and protective devices connected.
[Siemens]Электромагнитные трансформаторы тока понижают значение рабочих токов и токов короткого замыкания до значений, приемлемых для измерительных приборов и устройств защиты.
[Перевод Интент]Тематики
Классификация
>>>Обобщающие термины
Синонимы
- ТТ
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > réducteur de courant
-
22 transformateur de courant
трансформатор тока
Трансформатор, в котором при нормальных условиях применения вторичный ток практически пропорционален первичному току и при правильном включении сдвинут относительно него по фазе на угол, близкий к нулю.
[ ГОСТ 18685-73]
трансформатор тока
Трансформатор, сигнал на выходе которого пропорционален входному току. [МЭС 321-02-01, измененный ]
Примечание
Катушка Роговского с интегрирующей цепью представляет собой широкополосный трансформатор тока.
[МЭК 60-2]EN
current transformer
an instrument transformer in which the secondary current, in normal conditions of use, is substantially proportional to the primary current and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections
[IEV number 321-02-01]FR
transformateur de courant
transformateur de mesure dans lequel le courant secondaire est, dans les conditions normales d'emploi, pratiquement proportionnel au courant primaire et déphasé par rapport à celui-ci d'un angle approximativement nul pour un sens approprié des connexions
[IEV number 321-02-01]... электромагнитные трансформаторы тока (далее — трансформаторы) на номинальное напряжение от 0,66 до 750 кВ включительно, предназначенные для передачи сигнала измерительной информации приборам измерения, защиты, автоматики, сигнализации и управления в электрических цепях переменного тока частотой 50 или 60 Гц.
[ ГОСТ 7746-2001]Параллельные тексты EN-RU
Inductive current transformers (CT) step the operating currents and short-circuit currents down to values which are suitable for measuring instruments and protective devices connected.
[Siemens]Электромагнитные трансформаторы тока понижают значение рабочих токов и токов короткого замыкания до значений, приемлемых для измерительных приборов и устройств защиты.
[Перевод Интент]Тематики
Классификация
>>>Обобщающие термины
Синонимы
- ТТ
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > transformateur de courant
-
23 positive phase-sequence reactance
реактивное сопротивление прямой последовательности
-EN
positive sequence reactance
the quotient of the reactive fundamental component of the positive sequence armature voltage, due to the sinusoidal positive sequence armature current at rated frequency, by the value of that component of current, the machine running at rated speed
[IEV ref 411-50-14]FR
réactance directe
quotient du terme fondamental de la composante réactive de la tension d'induit directe, due à la composante directe du courant d'induit sinusoïdal à fréquence assignée, par la valeur de ce courant, la machine tournant à sa vitesse assignée
[IEV ref 411-50-14]
Тематики
- электротехника, основные понятия
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > positive phase-sequence reactance
-
24 transformateur de courant compoundé
трансформатор тока со вспомогательной обмоткой (для компенсации фазовой погрешности)
-EN
compound-wound current transformer
a current transformer having an auxiliary winding with an independent supply especially intended to reduce the phase displacement between the primary and secondary currents
[IEV number 321-02-14]FR
transformateur de courant compoundé
transformateur de courant comportant un enroulement auxiliaire, alimenté indépendamment et destiné essentiellement à réduire le déphasage entre les courants primaire et secondaire
[IEV number 321-02-14]Тематики
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > transformateur de courant compoundé
-
25 three-phase four-wire a.c. system
трехфазная четырехпроводная система переменного тока
-
[Интент]EN
three-phase four-wire a.c. system
system comprising four conductors of which three are connected to a three-phase supply and the fourth to a neutral point in the source of supply
[IEC 60092-507, ed. 2.0 (2008-01)]FR
distribution en triphasé à trois fils
réseau à courant alternatif comprenant quatre conducteurs dont trois sont raccordés à une source triphasée et le quatrième au point neutre de la source de l’alimentation
[IEC 60092-507, ed. 2.0 (2008-01)]Трехфазная четырехпроводная сеть с глухозаземленной нейтралью
Параллельные тексты EN-RU
Ground-fault protection in 3P+N system is activated by installing a external sensor(CT) in the neutral conductor and connecting to ET Trip System.
[Schneider Electric]Защита от замыкания на землю в 3-фазной четырехпроводной сети осуществляется с помощью внешнего трансформатора тока (ТТ), установленного на нулевом рабочем проводнике и подключенного к расцепителю ET.
[Перевод Интент]
Тематики
Синонимы
EN
- 3P+N system
- 3PH4W
- three-phase four-wire a.c. system
- three-phase system with neutral
FR
Англо-русский словарь нормативно-технической терминологии > three-phase four-wire a.c. system
-
26 three-phase system with neutral
трехфазная четырехпроводная система переменного тока
-
[Интент]EN
three-phase four-wire a.c. system
system comprising four conductors of which three are connected to a three-phase supply and the fourth to a neutral point in the source of supply
[IEC 60092-507, ed. 2.0 (2008-01)]FR
distribution en triphasé à trois fils
réseau à courant alternatif comprenant quatre conducteurs dont trois sont raccordés à une source triphasée et le quatrième au point neutre de la source de l’alimentation
[IEC 60092-507, ed. 2.0 (2008-01)]Трехфазная четырехпроводная сеть с глухозаземленной нейтралью
Параллельные тексты EN-RU
Ground-fault protection in 3P+N system is activated by installing a external sensor(CT) in the neutral conductor and connecting to ET Trip System.
[Schneider Electric]Защита от замыкания на землю в 3-фазной четырехпроводной сети осуществляется с помощью внешнего трансформатора тока (ТТ), установленного на нулевом рабочем проводнике и подключенного к расцепителю ET.
[Перевод Интент]
Тематики
Синонимы
EN
- 3P+N system
- 3PH4W
- three-phase four-wire a.c. system
- three-phase system with neutral
FR
Англо-русский словарь нормативно-технической терминологии > three-phase system with neutral
-
27 tension phase-neutre
фазное напряжение
Напряжение между линейным и нейтральным проводниками в данной точке электрической цепи переменного тока.
[ ГОСТ Р МЭК 60050-195-2005]
[ ГОСТ Р МЭК 60050-826-2009]EN
line-to-neutral voltage
voltage between a line conductor and the neutral conductor at a given point of an AC circuit
Source: 601-01-30 MOD
[IEV number 195-05-02]FR
tension phase-neutre
tension entre un conducteur de ligne et le conducteur de neutre en un point donné d'un circuit à courant alternatif
Source: 601-01-30 MOD
[IEV number 195-05-02]Недопустимые, нерекомендуемые
Тематики
EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > tension phase-neutre
-
28 линейный ток
линейный ток
Ток, протекающий в линейном проводнике трехфазной электрической цепи, соединяющем источник и приемник электрической энергии.EN
phase current, I
value of the current flowing in each phase of an electrical distribution system
[IEC 61557-12, ed. 1.0 (2007-08)]FR
courant de phase, I
valeur du courant circulant dans chaque phase d’un réseau de distribution électrique
[IEC 61557-12, ed. 1.0 (2007-08)]
Четырехпроводная система трехфазного токаНейтраль - обшая точка соединенных концов фазных обмоток генератора (источника питания). То же самое относится и к потребителю (нагрузке).
Линейные провода ( проводники) - проводники, присоединенные к началу фазных обмоток (А, В и С).
Звезда ( соединение звездой) - представленное на рисунке соединение, в котором начала обмоток соединены в одну общую точку.
Нулейвой провод ( проводник) или нулевой рабочий провод (проводник) - проводник соединяющий нейтрали генератора (источника питания) и потребителя (нагрузки). Нулевой провод выполняет роль обратного провода.
Линейное напряжение - напряжение между линейными проводами.
Фазное напряжение - напряжение между линейным и нулевым проводом.
Фазный ток - ток, протекающий по фазной обмотке генератора (источника питания) или потребителя.
Линейный ток - ток, протекающий по линейному проводу.
При соединении звездой линейный ток равен фазному.
При работе по нулевому проводу протекает ток, равный векторной сумме трех линейных токов: IА, IB и IC.
Если фазы нагружены равномерно, то ток нулевого провода равен нулю.
[На основе книги Кузнецов М. И. Основы электротехники. М, "Высшая Школа", 1964]Тематики
- электротехника, основные понятия
EN
FR
Русско-французский словарь нормативно-технической терминологии > линейный ток
-
29 линейный ток
линейный ток
Ток, протекающий в линейном проводнике трехфазной электрической цепи, соединяющем источник и приемник электрической энергии.EN
phase current, I
value of the current flowing in each phase of an electrical distribution system
[IEC 61557-12, ed. 1.0 (2007-08)]FR
courant de phase, I
valeur du courant circulant dans chaque phase d’un réseau de distribution électrique
[IEC 61557-12, ed. 1.0 (2007-08)]
Четырехпроводная система трехфазного токаНейтраль - обшая точка соединенных концов фазных обмоток генератора (источника питания). То же самое относится и к потребителю (нагрузке).
Линейные провода ( проводники) - проводники, присоединенные к началу фазных обмоток (А, В и С).
Звезда ( соединение звездой) - представленное на рисунке соединение, в котором начала обмоток соединены в одну общую точку.
Нулейвой провод ( проводник) или нулевой рабочий провод (проводник) - проводник соединяющий нейтрали генератора (источника питания) и потребителя (нагрузки). Нулевой провод выполняет роль обратного провода.
Линейное напряжение - напряжение между линейными проводами.
Фазное напряжение - напряжение между линейным и нулевым проводом.
Фазный ток - ток, протекающий по фазной обмотке генератора (источника питания) или потребителя.
Линейный ток - ток, протекающий по линейному проводу.
При соединении звездой линейный ток равен фазному.
При работе по нулевому проводу протекает ток, равный векторной сумме трех линейных токов: IА, IB и IC.
Если фазы нагружены равномерно, то ток нулевого провода равен нулю.
[На основе книги Кузнецов М. И. Основы электротехники. М, "Высшая Школа", 1964]Тематики
- электротехника, основные понятия
EN
FR
Русско-английский словарь нормативно-технической терминологии > линейный ток
-
30 line current
линейный ток
Ток, протекающий в линейном проводнике трехфазной электрической цепи, соединяющем источник и приемник электрической энергии.EN
phase current, I
value of the current flowing in each phase of an electrical distribution system
[IEC 61557-12, ed. 1.0 (2007-08)]FR
courant de phase, I
valeur du courant circulant dans chaque phase d’un réseau de distribution électrique
[IEC 61557-12, ed. 1.0 (2007-08)]
Четырехпроводная система трехфазного токаНейтраль - обшая точка соединенных концов фазных обмоток генератора (источника питания). То же самое относится и к потребителю (нагрузке).
Линейные провода ( проводники) - проводники, присоединенные к началу фазных обмоток (А, В и С).
Звезда ( соединение звездой) - представленное на рисунке соединение, в котором начала обмоток соединены в одну общую точку.
Нулейвой провод ( проводник) или нулевой рабочий провод (проводник) - проводник соединяющий нейтрали генератора (источника питания) и потребителя (нагрузки). Нулевой провод выполняет роль обратного провода.
Линейное напряжение - напряжение между линейными проводами.
Фазное напряжение - напряжение между линейным и нулевым проводом.
Фазный ток - ток, протекающий по фазной обмотке генератора (источника питания) или потребителя.
Линейный ток - ток, протекающий по линейному проводу.
При соединении звездой линейный ток равен фазному.
При работе по нулевому проводу протекает ток, равный векторной сумме трех линейных токов: IА, IB и IC.
Если фазы нагружены равномерно, то ток нулевого провода равен нулю.
[На основе книги Кузнецов М. И. Основы электротехники. М, "Высшая Школа", 1964]Тематики
- электротехника, основные понятия
EN
FR
Англо-русский словарь нормативно-технической терминологии > line current
-
31 дифференциальная защита от замыканий на землю
- Nullstromdifferentialschutz, m
дифференциальная защита от замыканий на землю
Защита, в которой остаточный ток комплекта из трех фазных трансформаторов тока уравновешен остаточным током на выходе такого же комплекта трансформаторов тока или, как это чаще бывает, одного трансформатора тока, расположенного на заземляющем соединении, если таковое имеется в нейтральной точке.
Примечание - Этот термин также употребляется в случаях, когда нейтраль защищаемой установки не заземлена, т.е. когда для защиты участка не требуется ни второй комплект из трех фазных трансформаторов тока, ни трансформатор тока в соединении нейтрали.
[Разработка типовых структурных схем микропроцессорных устройств РЗА на объектах ОАО "ФКС ЕЭС". Пояснительная записка. Новосибирск 2006 г.]EN
restricted earth-fault protection
ground differential protection (US)
protection in which the residual current from a set of three-phase current transformers is balanced against the residual output from a similar set of current transformers or, more usually, from a single current transformer located on the earthing connection, if any, of a neutral point
Note – This term is also used when the neutral of the protected plant is unearthed i.e. neither a second set of three-phase current transformers nor a current transformer in the neutral connection is needed to restrict the protected section.
[ IEV ref 448-14-29]FR
protection différentielle de défaut à la terre
protection dans laquelle le courant résiduel en provenance d'un ensemble de trois transformateurs de courant de phase est comparé à celui en provenance d'un ensemble similaire de transformateurs de courant ou, plus habituellement, d'un seul transformateur de courant placé dans la connexion de mise à la terre d'un point neutre, s'il y en a un
Note – Ce terme est aussi utilisé lorsque le neutre de l'installation protégée n'est pas relié à la terre, c'est à dire que ni un deuxième ensemble de trois transformateurs de courant de phase ni un transformateur de courant dans la connexion de neutre ne sont nécessaires pour limiter la section protégée
[ IEV ref 448-14-29]Тематики
EN
DE
- Nullstromdifferentialschutz, m
FR
Русско-немецкий словарь нормативно-технической терминологии > дифференциальная защита от замыканий на землю
-
32 protection différentielle de défaut à la terre
дифференциальная защита от замыканий на землю
Защита, в которой остаточный ток комплекта из трех фазных трансформаторов тока уравновешен остаточным током на выходе такого же комплекта трансформаторов тока или, как это чаще бывает, одного трансформатора тока, расположенного на заземляющем соединении, если таковое имеется в нейтральной точке.
Примечание - Этот термин также употребляется в случаях, когда нейтраль защищаемой установки не заземлена, т.е. когда для защиты участка не требуется ни второй комплект из трех фазных трансформаторов тока, ни трансформатор тока в соединении нейтрали.
[Разработка типовых структурных схем микропроцессорных устройств РЗА на объектах ОАО "ФКС ЕЭС". Пояснительная записка. Новосибирск 2006 г.]EN
restricted earth-fault protection
ground differential protection (US)
protection in which the residual current from a set of three-phase current transformers is balanced against the residual output from a similar set of current transformers or, more usually, from a single current transformer located on the earthing connection, if any, of a neutral point
Note – This term is also used when the neutral of the protected plant is unearthed i.e. neither a second set of three-phase current transformers nor a current transformer in the neutral connection is needed to restrict the protected section.
[ IEV ref 448-14-29]FR
protection différentielle de défaut à la terre
protection dans laquelle le courant résiduel en provenance d'un ensemble de trois transformateurs de courant de phase est comparé à celui en provenance d'un ensemble similaire de transformateurs de courant ou, plus habituellement, d'un seul transformateur de courant placé dans la connexion de mise à la terre d'un point neutre, s'il y en a un
Note – Ce terme est aussi utilisé lorsque le neutre de l'installation protégée n'est pas relié à la terre, c'est à dire que ni un deuxième ensemble de trois transformateurs de courant de phase ni un transformateur de courant dans la connexion de neutre ne sont nécessaires pour limiter la section protégée
[ IEV ref 448-14-29]Тематики
EN
DE
- Nullstromdifferentialschutz, m
FR
Франко-русский словарь нормативно-технической терминологии > protection différentielle de défaut à la terre
-
33 Nullstromdifferentialschutz, m
дифференциальная защита от замыканий на землю
Защита, в которой остаточный ток комплекта из трех фазных трансформаторов тока уравновешен остаточным током на выходе такого же комплекта трансформаторов тока или, как это чаще бывает, одного трансформатора тока, расположенного на заземляющем соединении, если таковое имеется в нейтральной точке.
Примечание - Этот термин также употребляется в случаях, когда нейтраль защищаемой установки не заземлена, т.е. когда для защиты участка не требуется ни второй комплект из трех фазных трансформаторов тока, ни трансформатор тока в соединении нейтрали.
[Разработка типовых структурных схем микропроцессорных устройств РЗА на объектах ОАО "ФКС ЕЭС". Пояснительная записка. Новосибирск 2006 г.]EN
restricted earth-fault protection
ground differential protection (US)
protection in which the residual current from a set of three-phase current transformers is balanced against the residual output from a similar set of current transformers or, more usually, from a single current transformer located on the earthing connection, if any, of a neutral point
Note – This term is also used when the neutral of the protected plant is unearthed i.e. neither a second set of three-phase current transformers nor a current transformer in the neutral connection is needed to restrict the protected section.
[ IEV ref 448-14-29]FR
protection différentielle de défaut à la terre
protection dans laquelle le courant résiduel en provenance d'un ensemble de trois transformateurs de courant de phase est comparé à celui en provenance d'un ensemble similaire de transformateurs de courant ou, plus habituellement, d'un seul transformateur de courant placé dans la connexion de mise à la terre d'un point neutre, s'il y en a un
Note – Ce terme est aussi utilisé lorsque le neutre de l'installation protégée n'est pas relié à la terre, c'est à dire que ni un deuxième ensemble de trois transformateurs de courant de phase ni un transformateur de courant dans la connexion de neutre ne sont nécessaires pour limiter la section protégée
[ IEV ref 448-14-29]Тематики
EN
DE
- Nullstromdifferentialschutz, m
FR
Немецко-русский словарь нормативно-технической терминологии > Nullstromdifferentialschutz, m
-
34 дифференциальная защита от замыканий на землю
дифференциальная защита от замыканий на землю
Защита, в которой остаточный ток комплекта из трех фазных трансформаторов тока уравновешен остаточным током на выходе такого же комплекта трансформаторов тока или, как это чаще бывает, одного трансформатора тока, расположенного на заземляющем соединении, если таковое имеется в нейтральной точке.
Примечание - Этот термин также употребляется в случаях, когда нейтраль защищаемой установки не заземлена, т.е. когда для защиты участка не требуется ни второй комплект из трех фазных трансформаторов тока, ни трансформатор тока в соединении нейтрали.
[Разработка типовых структурных схем микропроцессорных устройств РЗА на объектах ОАО "ФКС ЕЭС". Пояснительная записка. Новосибирск 2006 г.]EN
restricted earth-fault protection
ground differential protection (US)
protection in which the residual current from a set of three-phase current transformers is balanced against the residual output from a similar set of current transformers or, more usually, from a single current transformer located on the earthing connection, if any, of a neutral point
Note – This term is also used when the neutral of the protected plant is unearthed i.e. neither a second set of three-phase current transformers nor a current transformer in the neutral connection is needed to restrict the protected section.
[ IEV ref 448-14-29]FR
protection différentielle de défaut à la terre
protection dans laquelle le courant résiduel en provenance d'un ensemble de trois transformateurs de courant de phase est comparé à celui en provenance d'un ensemble similaire de transformateurs de courant ou, plus habituellement, d'un seul transformateur de courant placé dans la connexion de mise à la terre d'un point neutre, s'il y en a un
Note – Ce terme est aussi utilisé lorsque le neutre de l'installation protégée n'est pas relié à la terre, c'est à dire que ni un deuxième ensemble de trois transformateurs de courant de phase ni un transformateur de courant dans la connexion de neutre ne sont nécessaires pour limiter la section protégée
[ IEV ref 448-14-29]Тематики
EN
DE
- Nullstromdifferentialschutz, m
FR
Русско-английский словарь нормативно-технической терминологии > дифференциальная защита от замыканий на землю
-
35 дифференциальная защита от замыканий на землю
дифференциальная защита от замыканий на землю
Защита, в которой остаточный ток комплекта из трех фазных трансформаторов тока уравновешен остаточным током на выходе такого же комплекта трансформаторов тока или, как это чаще бывает, одного трансформатора тока, расположенного на заземляющем соединении, если таковое имеется в нейтральной точке.
Примечание - Этот термин также употребляется в случаях, когда нейтраль защищаемой установки не заземлена, т.е. когда для защиты участка не требуется ни второй комплект из трех фазных трансформаторов тока, ни трансформатор тока в соединении нейтрали.
[Разработка типовых структурных схем микропроцессорных устройств РЗА на объектах ОАО "ФКС ЕЭС". Пояснительная записка. Новосибирск 2006 г.]EN
restricted earth-fault protection
ground differential protection (US)
protection in which the residual current from a set of three-phase current transformers is balanced against the residual output from a similar set of current transformers or, more usually, from a single current transformer located on the earthing connection, if any, of a neutral point
Note – This term is also used when the neutral of the protected plant is unearthed i.e. neither a second set of three-phase current transformers nor a current transformer in the neutral connection is needed to restrict the protected section.
[ IEV ref 448-14-29]FR
protection différentielle de défaut à la terre
protection dans laquelle le courant résiduel en provenance d'un ensemble de trois transformateurs de courant de phase est comparé à celui en provenance d'un ensemble similaire de transformateurs de courant ou, plus habituellement, d'un seul transformateur de courant placé dans la connexion de mise à la terre d'un point neutre, s'il y en a un
Note – Ce terme est aussi utilisé lorsque le neutre de l'installation protégée n'est pas relié à la terre, c'est à dire que ni un deuxième ensemble de trois transformateurs de courant de phase ni un transformateur de courant dans la connexion de neutre ne sont nécessaires pour limiter la section protégée
[ IEV ref 448-14-29]Тематики
EN
DE
- Nullstromdifferentialschutz, m
FR
Русско-французский словарь нормативно-технической терминологии > дифференциальная защита от замыканий на землю
-
36 ground differential protection
дифференциальная защита нулевой последовательности
дифференциальная токовая защита нулевой последовательности
ДНП
Предназначена для защиты (трансформатора) от замыканий на землю. Реагирует на разность тока в нейтрали и расчетного тока нулевой последовательности со стороны ВН.
[СТО 56947007-29.120.70.100-2011]Дифференциальная защита нулевой последовательности (ДНП) имеет три принципа действия:
-
ДНП с торможением по сумме фазных токов;
базируется на сравнении тока 3I0, полученного, как геометрическая сумма фазных токов рассматриваемой обмотки трансформатора (устройство MICOM P63х рассчитывает сумму трех фазных токов), с протекающим в ее нейтрали током IНЕЙТРАЛИ, -
ДНП с торможением от максимального фазного тока,
базируется на сравнении максимального фазного тока рассматриваемой обмотки трансформатора (автотрансформатора), с протекающим в ее нейтрали током IНЕЙТРАЛИ, -
высокоомная ДНП
(в Российской Федерации не применяется).
[СТО 56947007-29.120.70.100-2011]
Тематики
Синонимы
EN
дифференциальная защита от замыканий на землю
Защита, в которой остаточный ток комплекта из трех фазных трансформаторов тока уравновешен остаточным током на выходе такого же комплекта трансформаторов тока или, как это чаще бывает, одного трансформатора тока, расположенного на заземляющем соединении, если таковое имеется в нейтральной точке.
Примечание - Этот термин также употребляется в случаях, когда нейтраль защищаемой установки не заземлена, т.е. когда для защиты участка не требуется ни второй комплект из трех фазных трансформаторов тока, ни трансформатор тока в соединении нейтрали.
[Разработка типовых структурных схем микропроцессорных устройств РЗА на объектах ОАО "ФКС ЕЭС". Пояснительная записка. Новосибирск 2006 г.]EN
restricted earth-fault protection
ground differential protection (US)
protection in which the residual current from a set of three-phase current transformers is balanced against the residual output from a similar set of current transformers or, more usually, from a single current transformer located on the earthing connection, if any, of a neutral point
Note – This term is also used when the neutral of the protected plant is unearthed i.e. neither a second set of three-phase current transformers nor a current transformer in the neutral connection is needed to restrict the protected section.
[ IEV ref 448-14-29]FR
protection différentielle de défaut à la terre
protection dans laquelle le courant résiduel en provenance d'un ensemble de trois transformateurs de courant de phase est comparé à celui en provenance d'un ensemble similaire de transformateurs de courant ou, plus habituellement, d'un seul transformateur de courant placé dans la connexion de mise à la terre d'un point neutre, s'il y en a un
Note – Ce terme est aussi utilisé lorsque le neutre de l'installation protégée n'est pas relié à la terre, c'est à dire que ni un deuxième ensemble de trois transformateurs de courant de phase ni un transformateur de courant dans la connexion de neutre ne sont nécessaires pour limiter la section protégée
[ IEV ref 448-14-29]Тематики
EN
DE
- Nullstromdifferentialschutz, m
FR
Англо-русский словарь нормативно-технической терминологии > ground differential protection
-
ДНП с торможением по сумме фазных токов;
-
37 restricted earth-fault protection
дифференциальная защита от замыканий на землю
Защита, в которой остаточный ток комплекта из трех фазных трансформаторов тока уравновешен остаточным током на выходе такого же комплекта трансформаторов тока или, как это чаще бывает, одного трансформатора тока, расположенного на заземляющем соединении, если таковое имеется в нейтральной точке.
Примечание - Этот термин также употребляется в случаях, когда нейтраль защищаемой установки не заземлена, т.е. когда для защиты участка не требуется ни второй комплект из трех фазных трансформаторов тока, ни трансформатор тока в соединении нейтрали.
[Разработка типовых структурных схем микропроцессорных устройств РЗА на объектах ОАО "ФКС ЕЭС". Пояснительная записка. Новосибирск 2006 г.]EN
restricted earth-fault protection
ground differential protection (US)
protection in which the residual current from a set of three-phase current transformers is balanced against the residual output from a similar set of current transformers or, more usually, from a single current transformer located on the earthing connection, if any, of a neutral point
Note – This term is also used when the neutral of the protected plant is unearthed i.e. neither a second set of three-phase current transformers nor a current transformer in the neutral connection is needed to restrict the protected section.
[ IEV ref 448-14-29]FR
protection différentielle de défaut à la terre
protection dans laquelle le courant résiduel en provenance d'un ensemble de trois transformateurs de courant de phase est comparé à celui en provenance d'un ensemble similaire de transformateurs de courant ou, plus habituellement, d'un seul transformateur de courant placé dans la connexion de mise à la terre d'un point neutre, s'il y en a un
Note – Ce terme est aussi utilisé lorsque le neutre de l'installation protégée n'est pas relié à la terre, c'est à dire que ni un deuxième ensemble de trois transformateurs de courant de phase ni un transformateur de courant dans la connexion de neutre ne sont nécessaires pour limiter la section protégée
[ IEV ref 448-14-29]Тематики
EN
DE
- Nullstromdifferentialschutz, m
FR
Англо-русский словарь нормативно-технической терминологии > restricted earth-fault protection
-
38 фаза тока
neng. phase de courant, (синусоидального) phase en courant -
39 ток в фазе
neng. courant en phase -
40 ток, совпадающий по фазе
neng. courant en phaseDictionnaire russe-français universel > ток, совпадающий по фазе
См. также в других словарях:
courant de phase — fazinė srovė statusas T sritis automatika atitikmenys: angl. phase current vok. Phasenstrom, m rus. фазный ток, m; фазовый ток, m pranc. courant de phase, m … Automatikos terminų žodynas
courant de phase — fazinė srovė statusas T sritis fizika atitikmenys: angl. phase current vok. Phasenstrom, m rus. фазный ток, m; фазовый ток, m pranc. courant de phase, m … Fizikos terminų žodynas
Courant Alternatif — Pour les articles homonymes, voir Courant alternatif (revue). Le courant alternatif (qui peut être abrégé par CA, ou AC, pour Alternating Current en anglais, étant cependant souvent utilisé) est un courant électrique qui change de sens. Ce… … Wikipédia en Français
Courant électrique alternatif — Courant alternatif Pour les articles homonymes, voir Courant alternatif (revue). Le courant alternatif (qui peut être abrégé par CA, ou AC, pour Alternating Current en anglais, étant cependant souvent utilisé) est un courant électrique qui change … Wikipédia en Français
Phase (électricité) — Pour les articles homonymes, voir Phase. Le mot phase désigne : un décalage temporel entre des tensions ou signaux ; un des fils conducteurs, également appelé fil de phase, qui transporte un courant alternatif avec un tel décalage… … Wikipédia en Français
Courant alternatif — Pour les articles homonymes, voir Courant alternatif (revue). Le courant alternatif (qui peut être abrégé par CA, ou AC, pour Alternating Current en anglais, cependant souvent utilisé) est un courant électrique qui change de sens, il est tantôt… … Wikipédia en Français
Phase mobile — Chromatographie La chromatographie est une technique d analyse qualitative et quantitative de la chimie analytique dans laquelle l échantillon contenant une ou plusieurs espèces est entraîné par un courant de phase mobile (liquide, gaz ou fluide… … Wikipédia en Français
Phase stationnaire — Chromatographie La chromatographie est une technique d analyse qualitative et quantitative de la chimie analytique dans laquelle l échantillon contenant une ou plusieurs espèces est entraîné par un courant de phase mobile (liquide, gaz ou fluide… … Wikipédia en Français
phase current — fazinė srovė statusas T sritis automatika atitikmenys: angl. phase current vok. Phasenstrom, m rus. фазный ток, m; фазовый ток, m pranc. courant de phase, m … Automatikos terminų žodynas
phase current — fazinė srovė statusas T sritis fizika atitikmenys: angl. phase current vok. Phasenstrom, m rus. фазный ток, m; фазовый ток, m pranc. courant de phase, m … Fizikos terminų žodynas
Courant De Court-circuit — Le courant de court circuit d un générateur de tension parfait est, en théorie, infini. Fort heureusement, en pratique, la valeur du courant de court circuit est finie, limitée par les impédances internes de la source, des divers tronçons de… … Wikipédia en Français