1 длительный допустимый ток
- Strombelastbarkeit, f
- Dauerstrombelastbarkeit, f
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Русско-немецкий словарь нормативно-технической терминологии > длительный допустимый ток
См. также в других словарях:
Continuous Flow System — Tintenbehälter eines CIS Die Schläuche am Druckkopf Ein Continuous Ink System (CIS), auch Continuous Ink Supply System (CISS) genannt, ist ein kostengünstiger Ersatz für Patronen von Tintendruckern. Im Gegensatz z … Deutsch Wikipedia
Continuous ink system — A continuous ink system (CIS), also known as a continuous ink supply system (CISS), a continuous flow system (CFS), an automatic ink refill system (AIRS), a bulk feed ink system, or an off axis ink delivery system is a method for delivering a… … Wikipedia
Continuous Flow Analysis — (CFA) bezeichnet eine Analysentechnik, die nasschemische Analyseverfahren automatisch durchführt. Dabei werden die Verfahrenschritte von photometrisch analytischen Methoden in einem kontinuierliche Fluss von Probe und Reagenzien in der… … Deutsch Wikipedia
Continuous-flow manufacturing — (CFM) is a manufacturing strategy that produces a part via a just in time and kanban production approach, and calls for an ongoing examination and improvement efforts which ultimately requires integration of all elements of the production system … Wikipedia
Continuous Flow Manufacturing — (CFM) is a manufacturing strategy that produces a part via a just in time and kan ban production approach, and calls for an ongoing examination and improvement efforts which ultimately requires integration of all elements of the production system … Wikipedia
continuous-flow oxygen system — An oxygen system in which a metered quantity of oxygen is continuously supplied to the oxygen mask. A rebreathable type mask is generally used with such an oxygen system. Also called a constant flow oxygen system … Aviation dictionary
continuous-flow fuel injection system — The system for measuring fuel and delivering it under low pressure to the outside of the intake valve. This fuel, along with air necessary for combustion, is pulled into the cylinder when the intake valve opens. In spite of its name, it is not… … Aviation dictionary
Continuous reactor — Continuous reactors (alternatively referred to as flow reactors) carry material as a flowing stream. Reactants are continuously fed into the reactor and emerge as continuous stream of product. Continuous reactors are used for a wide variety of… … Wikipedia
Continuous motion pot washing — systems are (in the most basic form) three compartment sinks with an agitating wash compartment. Most commonly used in the food service industry, the term continuous motion pot washing describes washing systems that do not have a set wash cycle… … Wikipedia
continuous cycle absorption system — System which has a continuous flow of energy input … Dictionary of automotive terms
Flow chemistry — In flow chemistry, a chemical reaction is run in a continuously flowing stream rather than in batch production. In other words, pumps move fluid into a tube, and where tubes join one another, the fluids contact one another. If these fluids are… … Wikipedia