Перевод: со всех языков на французский

с французского на все языки

complex+systems

  • 1 длительный допустимый ток

    1. courant permanent admissible, m
    2. courant admissible, m

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-французский словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • Complex systems — A visual, organizational map of complex systems science See also: Complex system Complex systems present problems in mathematical modelling. The equations from which complex system models are developed generally derive from statistical physics,… …   Wikipedia

  • Complex Systems (journal) —   Discipline Complex Systems …   Wikipedia

  • New England Complex Systems Institute — Location Cambridge, MA Address 238 Main Street #319, Cambridge, MA Website necsi.edu The New England Complex Systems Institute (NECSI) is an American research institution dedicated to advancing the study …   Wikipedia

  • Center for Complex Systems and Brain Sciences — The Center for Complex Systems and Brain Sciences is a multi disciplinary research institute, internationally active in the fields of complexity science and neuroscience. The center is located in the Charles E. Schmidt College of Science of… …   Wikipedia

  • Max Planck Institute for the Physics of Complex Systems — The Max Planck Institute for the Physics of Complex systems is one of the 80 institutes of the Max Planck Gesellschaft, located in Dresden, Germany. Contents 1 Research 2 Collaborations …   Wikipedia

  • Institute for Biocomputation and Physics of Complex Systems — Established 8th October 2002 Location Zaragoza, Aragón, Spain …   Wikipedia

  • Mathematics Of Information Technology And Complex Systems — MITACS est l acronyme de Mathematics of Information Technology and Complex systems, c est à dire mathématiques des technologies de l information et des systèmes complexes. Il est installé à l Université Simon Fraser. C est un réseau canadien de… …   Wikipédia en Français

  • Mathematics of information technology and complex systems — MITACS est l acronyme de Mathematics of Information Technology and Complex systems, c est à dire mathématiques des technologies de l information et des systèmes complexes. Il est installé à l Université Simon Fraser. C est un réseau canadien de… …   Wikipédia en Français

  • Interdisciplinary Description of Complex Systems — (INDECS) is a peer reviewed scientific journal on complex systems, published in Zagreb, Croatia. It is published by a non governmental organization, the society znanost.org. See also * Croatian Interdisciplinary Society External links *… …   Wikipedia

  • Mathematics of Information Technology and Complex systems — MITACS est l acronyme de Mathematics of Information Technology and Complex systems, c est à dire mathématiques des technologies de l information et des systèmes complexes. Il est installé à l Université Simon Fraser. C est un réseau canadien de… …   Wikipédia en Français

  • Complex system biology — Complex systems biology (CSB) is a branch or subfield of mathematical and theoretical biology concerned with complexity of both structure and function in biological organisms, as well as the emergence and evolution of organisms and species, with… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»