  • 1 длительный допустимый ток

    1. courant permanent admissible, m
    2. courant admissible, m

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-французский словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • Cable jetting — is a technique to install cables in ducts [http://www.plumettaz.ch/en/products/optical fiber/jetting explanation.asp] . It is commonly used to install cables with optical fibers in underground polyethylene ducts and is an alternative to pulling …   Wikipedia

  • Cable lacing — is a method for tying wiring harnesses and cable looms, traditionally used in telecommunication, naval, and aerospace applications. This old cable management technique, taught to generations of linemen, is still used in some modern applications… …   Wikipedia

  • cable — [kā′bəl] n. [ME & OFr < LL capulum, a cable, rope < L capere, to take hold: see HAVE] 1. a thick, heavy rope, now often of wire strands 2. the strong, heavy chain attached to a ship s anchor: anchor cables were formerly of rope 3. CABLE… …   English World dictionary

  • cable — cablelike, adj. /kay beuhl/, n., v., cabled, cabling. n. 1. a heavy, strong rope. 2. a very strong rope made of strands of metal wire, as used to support cable cars or suspension bridges. 3. a cord of metal wire used to operate or pull a… …   Universalium

  • Cable — /kay beuhl/, n. George Washington, 1844 1925, U.S. novelist and short story writer. * * * (as used in expressions) Cable News Network cable modem cable structure cable television coaxial cable * * * ▪ electronics …   Universalium

  • Cable harness — [ car audio cables.] A cable harness, also known as a wire harness or wiring loom, is a string of cables and/or wires which transmit informational signals or operating currents (energy). The cables are bound together by clamps, cable ties,… …   Wikipedia

  • Cable-backed bow — A cable backed bow is a bow reinforced with a cable on the back. The cable is made from either animal, vegetable or synthetic fibers and is tightened to increase the strength of the bow. A cable will relieve tension stress from the back of the… …   Wikipedia

  • cable — Noun: A heavy rope, often made of wire; an underground or underseas bundle of wires in insulation used for the transmission of messages by telegraph or telephone. Verb: To send a message by underseas cable …   Ballentine's law dictionary

  • Optical fiber cable — A TOSLINK optical fiber cable with a clear jacket. These plastic fiber cables are used mainly for digital audio connections between devices. An optical fiber cable is a cable containing one or more optical fibers. The optical fiber elements are… …   Wikipedia

  • Monster Cable Products — For the company that runs a job recruitment website, see Monster Worldwide. Monster Cable Products Type Private Industry Consumer Electronics …   Wikipedia

  • Cross Sound Cable — The Cross Sound Cable is a 40 kilometres (25 mi) long bipolar high voltage direct current (HVDC) submarine power cable between New Haven, Connecticut, USA and Shoreham, Long Island New York , USA. The Cross Sound Cable can transmit a maximum …   Wikipedia

Поделиться ссылкой на выделенное