Перевод: с французского на русский

с русского на французский

bushings

  • 1 traversée

    1. проходной изолятор
    2. ввод (проходной изолятор)

     

    ввод
    Проходной изолятор, имеющий внутреннюю изоляцию из жидкого, твердого, газообразного диэлектрического материала или их комбинации.
    [ ГОСТ 27744-88 ]

    EN

    bushing
    device that enables one or several conductors to pass through a partition such as a wall or a tank, and insulate the conductors from it.
    NOTE 1 – The means of attachment (flange or fixing device) to the partition forms part of the bushing. The conductor may form an integral part of the bushing or be drawn into the central tube of the bushing.
    NOTE 2 – The bushings may be of the following types:
    - liquid-filled bushing;
    - liquid-insulated bushing;
    - gas-filled bushing;
    - gas-insulated bushing;
    - oil-impregnated paper bushing;
    - resin-bonded paper bushing;
    - resin-impregnated paper bushing;
    - ceramic, glass or analogous inorganic material bushing;
    - cast or moulded resin-insulated bushing;
    - combined insulation bushing;
    - compound-filled bushing;
    - gas-impregnated bushing.
    [IEV number 471-02-01]

    FR

    traversée
    dispositif servant à faire passer un ou plusieurs conducteurs à travers une paroi, telle qu’un mur ou une cuve, en isolant le(s) conducteur(s) de cette paroi.
    NOTE 1 – Les moyens de fixation (bride ou autre dispositif) sur la paroi font partie de la traversée. Le conducteur peut être solidaire de la traversée ou démontable.
    NOTE 2 – Les différentes traversées peuvent être les suivantes:
    - traversée à remplissage d’un liquide;
    - traversée à isolation liquide;
    - traversée à remplissage de gaz;
    - traversée à isolation gazeuse;
    - traversée en papier imprégné d’huile;
    - traversée en papier enduit de résine;
    - traversée en papier imprégné de résine;
    - traversée en matière céramique, en verre ou en matière inorganique analogue;
    - traversée à isolation en résine coulée ou moulée;
    - traversée à isolation combinée;
    - traversée à remplissage de mélange;
    - traversée imprégnée de gaz.
    [IEV number 471-02-01]

    0835

    Тематики

    EN

    DE

    • Durchführung, f

    FR

     

    проходной изолятор
    Изолятор, предназначенный для провода токоведущих элементов через стенку, имеющую другой электрический потенциал.
    [ ГОСТ 27744-88]


    проходной изолятор
    -
    [IEV number 151-15-40]

    EN

    (insulating) bushing
    insulator forming a passage for a conductor through a non-insulating partition
    [IEV number 151-15-40]

    bushing
    A bushing is a cyclindrical insulating component, usually made of ceramic, that houses a conductor. It enables a conductor to pass through a grounded enclosure, such as a transformer tank (the physical shell of a transformer), a wall or other physical barrier, to connect electrical installations. In the case of a transformer, bushings protect the conductors that connect a transformer’s core to the power system it serves through channels in the transformer’s housing.
    [ABB. Glossary of technical terms. 2010]

    FR

    isolateur de traversée, m
    traversée, f

    isolateur permettant le passage d'un conducteur à travers une paroi non isolante
    [IEV number 151-15-40]

    0317
    Проходной изолятор

    Параллельные тексты EN-RU

    The circuit breaker is connected via bushings to the rest of the switchgear at the flanges provided.
    [Siemens]

    С другими частями распределительного устройства силовой выключатель соединяется через проходные изоляторы, закрепленные в его фланцах.
    [Перевод Интент]

    Тематики

    Классификация

    >>>

    Обобщающие термины

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > traversée

  • 2 isolateur de traversée, m

    1. проходной изолятор

     

    проходной изолятор
    Изолятор, предназначенный для провода токоведущих элементов через стенку, имеющую другой электрический потенциал.
    [ ГОСТ 27744-88]


    проходной изолятор
    -
    [IEV number 151-15-40]

    EN

    (insulating) bushing
    insulator forming a passage for a conductor through a non-insulating partition
    [IEV number 151-15-40]

    bushing
    A bushing is a cyclindrical insulating component, usually made of ceramic, that houses a conductor. It enables a conductor to pass through a grounded enclosure, such as a transformer tank (the physical shell of a transformer), a wall or other physical barrier, to connect electrical installations. In the case of a transformer, bushings protect the conductors that connect a transformer’s core to the power system it serves through channels in the transformer’s housing.
    [ABB. Glossary of technical terms. 2010]

    FR

    isolateur de traversée, m
    traversée, f

    isolateur permettant le passage d'un conducteur à travers une paroi non isolante
    [IEV number 151-15-40]

    0317
    Проходной изолятор

    Параллельные тексты EN-RU

    The circuit breaker is connected via bushings to the rest of the switchgear at the flanges provided.
    [Siemens]

    С другими частями распределительного устройства силовой выключатель соединяется через проходные изоляторы, закрепленные в его фланцах.
    [Перевод Интент]

    Тематики

    Классификация

    >>>

    Обобщающие термины

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > isolateur de traversée, m

  • 3 traversée à isolation gazeuse

    1. ввод с газовой изоляцией

     

    ввод с газовой изоляцией
    Ввод, в котором основной изоляцией является газ (отличающийся от окружающего воздуха) под давлением, большим атмосферного или равным ему.
    [ ГОСТ 27744-88]

    EN

    gas-insulated bushing
    bushing in which the major insulation consists of gas (other than ambient air) at atmospheric pressure or higher
    NOTE 1 This definition includes bushings which are intended to form an integral part of gas-insulated equipment, the gas of the equipment being in communication with that of the bushing.
    NOTE 2 A bushing which contains solid insulating materials other than the envelope containing the gas (e.g. support for conducting layers or insulating cylinder), is a combined insulation bushing (see 3.13).
    NOTE 3 A bushing in which the desired voltage grading is obtained by an arrangement of conducting or semi-conducting layers incorporated in an insulating material (e.g. plastic film) is referred to as a gas insulated condenser graded bushing.
    [IEC 60137, ed. 6.0 (2008-07)]

    FR

    traversée à isolation gazeuse
    traversée dont l'isolation principale est assurée par un gaz (autre que l'air ambiant) à une pression supérieure ou égale à la pression atmosphérique
    NOTE 1 Cette définition comprend les traversées destinées à faire partie intégrante d'une installation à isolation gazeuse où le gaz de l'installation est en communication avec celui de la traversée.
    NOTE 2 Une traversée qui comporte des matériaux isolants solides autres que l'enveloppe contenant le gaz (par exemple un support pour des couches conductrices ou un cylindre isolant) est une traversée à isolation composite (voir 3.13).
    NOTE 3 Une traversée dans laquelle la répartition de tension souhaitée est obtenue par la disposition de couches conductrices ou semi-conductrices incorporées au matériau isolant (par exemple film plastique) est désignée par une traversée à isolation gazeuse à répartition capacitive.
    [IEC 60137, ed. 6.0 (2008-07)]

    Тематики

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > traversée à isolation gazeuse

  • 4 sectionneur

    1. разъединитель

     

    разъединитель
    Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
    Примечание.
    1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
    Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.

    0043 Условное обозначение контакта разъединителя

    [ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]

    разъединитель
    Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
    Примечания
    1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
    2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
    3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
    4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
    [ ГОСТ Р 52726-2007]

    EN

    disconnector
    a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
    NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
    [IEV number 441-14-05]

    disconnector

    IEV 441-14-05 is applicable with the following additional notes:
    NOTE 1
    "Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
    "No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
    NOTE 2
    For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
    [IEC 62271-102]

    FR

    sectionneur
    appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
    NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
    [IEV number 441-14-05]

    Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:

    • изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
    • иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
    • быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
    • обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;

    [ ГОСТ Р МЭК 60204-1-2007]


    Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
    Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
    Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
    Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:

    1. Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
    2. Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
    3. Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
    4. Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
    5. Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
    6. Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.

    [ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]


    Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
    [ http://relay-protection.ru/content/view/46/8/1/1/]


    Параллельные тексты EN-RU

    b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
    [IEC 60204-1-2006]

    б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
    [Перевод Интент]

    Тематики

    • высоковольтный аппарат, оборудование...
    • релейная защита
    • электротехника, основные понятия

    Классификация

    >>>

    EN

    DE

    FR

    Смотри также

    Франко-русский словарь нормативно-технической терминологии > sectionneur

См. также в других словарях:

  • Bushings — Die so genannten Doh Doh sind Gummiringe, die sich zwischen den Achsen eines Skateboards befinden. Sie dienen zur Dämpfung der Kraft, die auf die Achse drückt. Der Fahrer kann durch Anziehen oder Lösen der Mittelschraube (King Pin) den Druck auf… …   Deutsch Wikipedia

  • bushings — Смотри Вкладыши …   Энциклопедический словарь по металлургии

  • bushings — n. metal insert (Mechanics, Electronics) …   English contemporary dictionary

  • Drill bushing — A drill bushing, also known as a jig bushing,[1] is a tool used in metalworking jigs to guide cutting tools, most commonly drill bits. Other tools that are commonly used in a drill bushing include counterbores, countersinks, and reamers. They are …   Wikipedia

  • Roller chain — [ frame|right|Roller chain and sprocket] Roller chain or bush roller chain is the type of chain most commonly used for transmission of mechanical power on bicycles, motorcycles, and in industrial and agricultural machinery. It is simple, reliable …   Wikipedia

  • Bushing (electrical) — A bushing is an electrical engineering component that insulates a high voltage conductor passing through a metal enclosure. Bushings appear on switchgear, transformers, circuit breakers and other high voltage equipment. Description The bushing is …   Wikipedia

  • Mountainboarding — MBS Pro 100 Mountainboard with noSno soft bindings Mountainboarding, also known as Dirtboarding, Offroad Boarding, Grass Boarding, and All Terrain Boarding (ATB), is a well established[1] if little known extreme sport, derived from snowboarding.… …   Wikipedia

  • Bushing — A mechanical bushing is a cylindrical lining designed to reduce friction and wear inside a hole, or constrict and restrain motion of mechanical parts. Bushing types One type of bushing is the threaded insert , a hardened metal insert with a… …   Wikipedia

  • Tenneco — Infobox Company company company name = Tenneco, Inc. industry = Auto parts foundation = company type = Public NYSE|TEN location = Lake Forest, Illinois products = Ride control, Emissions control, Elastomers revenue = $6,184 Mil (2007 Sales) key… …   Wikipedia

  • Skateboard — Skateboarder in the air A …   Wikipedia

  • Plain bearing — Crankshaft plain bearing shells A plain bearing, also known as a plane bearing[1] or a friction bearing[2] is the simplest type of bearing, comprising just a bearing surface and no rolling elem …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»