1 arcing time
- время дуги
- время горения дуги при отключении повреждения дугогасящим аппаратом
- время горения дуги
- время (горения) дуги
время (горения) дуги
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
время горения дуги при отключении повреждения дугогасящим аппаратом
—
[В.А.Семенов. Англо-русский словарь по релейной защите]Тематики
EN
время дуги
Время между моментами возникновения и окончательного погасания дуги.
[ ГОСТ Р 50339. 0-2003 ( МЭК 60269-1-98)]EN
arcing time
interval of time between the instant of the initiation of the arc and the instant of final arc extinction
[IEC 60127-1, ed. 2.0 (2006-06)]
arcing time
interval of time between the instant of the initiation of the arc between the arcing contacts and the instant of final arc extinction
[IEC 60077-3, ed. 1.0 (2001-12)]
arcing time
interval of time between the instant of the initiation of the arc in a fuse and the instant of final arc extinction in that fuse
[IEC 60077-5, ed. 1.0 (2003-07)]
arcing time
interval of time between the instant of the initiation of the arc in a pole or a fuse and the instant of final arc extinction in that pole or that fuse
[IEC 60282-2, ed. 3.0 (2008-04)]FR
durée d’arc
intervalle de temps entre l’instant du début de l’arc entre les contacts de coupure et l’instant de l’extinction finale de l’arc
[IEC 60077-3, ed. 1.0 (2001-12)]
durée d’arc
intervalle de temps entre l'instant de début de l'arc dans un fusible et l'instant de l'extinction finale de l'arc dans ce fusible
[IEC 60077-5, ed. 1.0 (2003-07)]
durée d’arc
intervalle de temps entre l’instant de début de l’arc sur un pôle ou sur un fusible et l’instant de l’extinction finale de l’arc sur ce pôle ou ce fusible
[IEC 60282-2, ed. 3.0 (2008-04)]Параллельные тексты EN-RU
Thanks to the new arcing chambers, the arc extinction time has been reduced, thereby guaranteeing high short-circuit current limitation.
[ABB]Благодаря применению новых дугогасительных камер уменьшено время дуги, вследствие чего гарантируется ограничение больших значений токов короткого замыкания.
[Перевод Интент]Тематики
- выключатель автоматический
- высоковольтный аппарат, оборудование...
- предохранитель
EN
FR
3.21 время горения дуги (arcing time): Промежуток времени между моментом возникновения дуги и моментом ее полного угасания.
Источник: ГОСТ Р МЭК 60127-1-2005: Миниатюрные плавкие предохранители. Часть 1. Терминология для миниатюрных плавких предохранителей и общие требования к миниатюрным плавким вставкам оригинал документа
Англо-русский словарь нормативно-технической терминологии > arcing time
-
2 current
1) течение; поток4) вчт. текущая запись•-
absorption current
- ac anode current -
action current
-
active current
-
actuating current
-
admissible continuous current
-
air current
-
alongshore current
-
alternate current
-
anode current
-
arbitrary noise current
-
arc current
-
arc-back current
-
arcing ground fault current
-
armature current
-
ascending current
-
audio-frequency current
-
avalanche current
-
back current
-
back short circuit current
-
backward current
-
barogradient current
-
base current
-
beam current
-
bearing currents
-
beating current
-
beat current
-
biasing current
-
bias current
-
biphase current
-
bleeder current
-
blind current
-
blowing current
-
body current
-
bottom current
-
boundary current
-
braking current
-
branch current
-
break induced current
-
breakaway starting current
-
breakdown current
-
breaking current
-
bucking current
-
bulk current
-
bypass current
-
capacitance current
-
capacitive current
-
capacity current
-
carrier current
-
cathode current
-
channel current
-
charging current
-
circulating current
-
circumpolar current
-
collector current
-
complex sinusoidal current
-
complex current
-
conduction current
-
conjugate complex sinusoidal current
-
conjugate complex current
-
constant current
-
consumption current
-
continuous current
-
continuous traction current
-
control current
-
convection current
-
core-loss current
-
creeping current
-
critical current
-
cross current
-
crystal current
-
current of realm
-
current of run-unit
-
current of set
-
cutoff current
-
damped alternating current
-
damped current
-
dark current
-
deep-water current
-
deep current
-
delta currents
-
density current
-
descending current
-
design current
-
dielectric absorption current
-
dielectric current
-
diffusion current
-
direct current
-
direct-axis current
-
discharge current
-
discontinuous current
-
displacement current
-
downward current
-
drift current
-
drive current
-
drop-away current
-
earth current
-
earth fault current
-
eddy currents
-
effective current
-
electric current
-
electrode current
-
electrolysis current
-
electron current
-
electron-beam induced current
-
emission current
-
emitter current
-
equalizing current
-
equivalent input noise current
-
excess current
-
exchange current
-
excitation current
-
external current
-
extra current
-
extraction current
-
extraneous current
-
feedback current
-
field current
-
filament current
-
firing current
-
flood current
-
fluctuating current
-
focusing-coil current
-
focus current
-
fold back current
-
follow current
-
forced alternating current
-
forced current
-
foreign currents
-
forward current
-
Foucault currents
-
free alternating current
-
free current
-
full-load current
-
fusing current
-
galvanic current
-
gas current
-
gate current
-
gate nontrigger current
-
gate trigger current
-
gate turnoff current
-
generation-recombination current
-
gradient current
-
grib current
-
ground current
-
ground-return current
-
harmonic current
-
heat current
-
heater current
-
high-frequency current
-
high-level input current
-
high-level output current
-
holding current
-
hold current
-
hold-on current
-
hole current
-
idle current
-
image current
-
impressed current
-
incident current
-
induced current
-
initial current
-
injection current
-
inphase current
-
input current
-
input leakage current
-
input offset current
-
inrush current
-
inshore current
-
instantaneous carrying current
-
instantaneous current
-
insulation current
-
interference current
-
intermittent current
-
inverse current
-
ion production current
-
ionic current
-
ion current
-
ionization current
-
irradiation-saturation current
-
lagging current
-
latching current
-
leading current
-
leakage current
-
let-go current
-
light current
-
lightning current
-
line charging current
-
linear current
-
load current
-
locked-rotor current
-
loop current
-
loss current
-
low-level input current
-
low-level output current
-
magnetization current
-
majority-carrier current
-
majority current
-
make induced current
-
make-and-brake current
-
making current
-
maximum power current
-
minority-carrier current
-
minority current
-
motor inrush current
-
nearshore current
-
near-surface current
-
net current
-
neutral current
-
neutron current
-
neutron diffusion current
-
noise current
-
no-load current
-
nonsinusoidal current
-
nontrigger current
-
non-turn-off
-
offset current
-
offshore current
-
off-state current
-
on-state current
-
open-circuit current
-
operating current
-
output current
-
overload current
-
parasitic current
-
peak arc current
-
peak current
-
peak switching current
-
peak withstand current
-
peak-point current
-
peak-to-peak current
-
perception current
-
periodic current
-
persistent current
-
phase current
-
phase-fault current
-
phasor current
-
photo-electric current
-
photo current
-
photo-generated current
-
photo-induced current
-
pickup current
-
piezoelectric current
-
pinch current
-
plasma current
-
polarization current
-
polyphase current
-
postarc current
-
power current
-
power follow current
-
prebreakdown current
-
preconduction current
-
primary current
-
principal current
-
probe current
-
pull-in current
-
pulsating current
-
pulse current
-
pyroelectric current
-
quadrature-axis current
-
quiescent current
-
rated current
-
rated temperature-rise current
-
reactive current
-
read current
-
recombination current
-
rectified current
-
reflected current
-
regulated current
-
relative short-circuit current
-
release current
-
residual current
-
rest current
-
return current
-
reverse current
-
reverse-biased current
-
reverse-induced current
-
RF current
-
ringing current
-
rip current
-
ripple current
-
root-mean-square current
-
running current
-
rupturing current
-
saturated drain current
-
saturation current
-
saw-tooth current
-
secondary current
-
secondary-electron emission current
-
shaft currents
-
sheath current
-
shelf current
-
shield current
-
shock current
-
short-circuit current
-
short-noise current
-
short-time thermal current
-
short-time withstand current
-
sine-wave current
-
single-phase current
-
sinusoidal current
-
slope current
-
sneak current
-
spindle-motor current
-
split current
-
stalled-motor current
-
standby current
-
standing current
-
star currents
-
starter current
-
steady leakage current
-
steady surface current
-
steady volume current
-
steady-state current
-
stray current
-
stroke current
-
subsurface current
-
subsynchronous frequency current
-
subsynchronous current
-
subtransient armature current
-
superconduction current
-
superimposed current
-
supply current
-
surface current
-
surface-leakage current
-
surge current
-
suspension current
-
sustained current
-
sustaining current
-
switched current
-
switching current
-
symmetrical alternate current
-
synchronizing current
-
telluric current
-
test current
-
thermal current
-
thermal noise current
-
thermionic current
-
thermostimulated current
-
three-phase current
-
threshold current
-
through current
-
tidal current
-
tolerance current
-
traction current
-
traffic current
-
transfer current
-
transient current
-
transient-decay current
-
transmission-line current
-
trigger current
-
turbidity current
-
turnoff current
-
turn-on current
-
two-phase current
-
undulating current
-
unidirectional current
-
unsymmetrical currents
-
upward current
-
valley point current
-
variable current
-
vector current
-
virtual current
-
voice-frequency current
-
voltaic current
-
wattful current
-
wattless current
-
welding current
-
whirling currents
-
wind current
-
withdrawal current
-
working current
-
work current
-
Zener current
-
zero-sequence current -
3 arcing ground fault current
Большой англо-русский и русско-английский словарь > arcing ground fault current
-
4 arcing ground fault current
Англо-русский словарь технических терминов > arcing ground fault current
-
5 arcing ground fault current
Техника: ток дугового замыкания на землюУниверсальный англо-русский словарь > arcing ground fault current
-
6 selectivity-limit current
предельный ток селективности Is Токовая координата точки пересечения полной время-токовой характеристики защитного аппарата со стороны нагрузки и преддуговой (для плавких предохранителей) время-токовой характеристики или время-токовой характеристики расцепления второго защитного аппарата.
Предельный ток селективности (см. рисунок А.1) — это предельное значение тока:- ниже которого при последовательном соединении двух аппаратов защиты от сверхтоков защитный аппарат со стороны нагрузки завершает операцию отключения, чтобы воспрепятствовать началу действия второго защитного аппарата (т. е. обеспечивается селективность);
- выше которого при последовательном соединении двух аппаратов защиты от сверхтоков защитный аппарат со стороны нагрузки может не успеть вовремя завершить операцию отключения, чтобы воспрепятствовать началу действия второго защитного аппарата (т. е. селективность не обеспечивается).
I - ожидаемый ток короткого замыкания;
Is - предельный ток селективности;
Icu - номинальная предельная наибольшая отключающая способность;
А - преддуговая характеристика плавкого предохранителя;
В - рабочая характеристика плавкого предохранителя;
С - рабочая характеристика нетокоограничивающего выключателя (N) (время отключения/ток и I2t/ток) Примечания.
1. А считают нижним пределом, В и С - верхними пределами.
2. Недиабатическая зона для I2t показана пунктиром Рис. А1.
Координация по сверхтокам между автоматическим выключателем и предохранителем
или резервной защитой, осуществляемой предохранителем.
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]EN
selectivity-limit current
the current coordinate of the intersection between the maximum break time-current characteristic of the protective device on the load side and the pre-arcing (for fuses) or tripping (for residual current devices) time-current characteristic of the other protective device
[IEV number 442-05-60]FR
courant limite
coordonnée du courant de l'intersection entre la caractéristique de durée maximale de coupure temps-courant du dispositif de protection côté aval et la caractéristique temps-courant de pré-arc (pour les fusibles) ou de déclenchement (pour les dispositifs de coupure différentiels) de l'autre dispositif de protection.
[IEV number 442-05-60]Тематики
- аппарат, изделие, устройство...
- выключатель автоматический
Синонимы
- Is
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > selectivity-limit current
-
7 time-current characteristic
время-токовая характеристика
Кривая, отражающая взаимосвязь времени, например преддугового или рабочего, и ожидаемого тока в указанных условиях эксплуатации.
МЭК 60050 (441-17-13).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
time-current characteristic
a curve giving the time, e.g. pre-arcing time or operating time, as a function of the prospective current under stated conditions of operation
[IEV number 441-17-13]FR
caractéristique temps-courant
courbe donnant la durée, par exemple durée de préarc ou durée de fonctionnement, en fonction du courant présumé dans des conditions déterminées de fonctionnement
[IEV number 441-17-13]
Время-токовая характеристика представляет собой зависимость времения срабатывания автоматического выключателя от тока, протекающего в его главной цепи.
На рисунке представлена типичная время-токовая характеристика автоматического выключателя.
По оси ординат отложено время срабатывания автоматического выключателя в секундах.
По оси абсцисс — отношение тока, протекающего в главной цепи автоматического выключателя к номинальному току.
Из графика видно, что при значении I/Iн≤1 время отключения автоматического выключателя стремится к бесконечности.
Иными словами, до тех пор, пока ток, протекающий в главной цепи автоматического выключателя, меньше или равен номинальному току, автоматический выключатель не отключится.
Из графика также видно, что чем больше значение I/Iн, тем быстрее автоматический выключатель отключится. Так, например, (для левой кривой) при значении I/Iн=7 автоматический выключатель отключится через 0,1 секунды, а при I/Iн=3 - через 20 секунд.
[Интент]
Рис. Legrand В автоматических выключателях с микропроцессорным расцепителем время-токовая характеристика имеет вид, представленный на рисунке и ее можно настраивать.
В такой время-токовой характеристике различают три зоны срабатывания:
- « Большая задержка». Эта зона соответствует тепловому расцепителю и защищает цепь от перегрузки;
- « Малая задержка». Это защита от «слабых» коротких замыканий (обычно в конце защищаемой линий). Порог срабатывания, как правило, можно настроить. За счет изменения порога срабатывания можно увеличить время задержки до 1 секунды, что используется для обеспечения надежной селективности срабатывания относительно расположенных ниже аппаратов защиты;
- « Мгновенно». Это защита от «мощных» коротких замыканий. Порог срабатывания устанавливается при изготовлении и зависит от модели автоматического выключателя.
Примечание. Представленная на рисунке характеристика называется также
трехступенчатой защитной характеристикой. См. " защитная характеристика автоматического выключателя"
[Интент]Тематики
- выключатель автоматический
- предохранитель
- расцепитель, тепловое реле
Синонимы
EN
- characteristic curve
- T-C curve
- time-current characteristic
- trip characteristic
- trip curve
- trip curve characteristic
- tripping characteristic
- tripping curve
DE
- Zeit/Strom-Kennlinie
FR
2.3.16 времятоковая характеристика (time-current characteristic): Кривая зависимости преддугового времени или времени отключения от ожидаемого тока в установленных условиях срабатывания.
[МЭС 441-17-13]
Примечание - Для времени свыше 0,1 с можно практически пренебречь разницей между преддуговым временем и временем отключения.
Источник: ГОСТ Р МЭК 60269-1-2010: Предохранители низковольтные плавкие. Часть 1. Общие требования оригинал документа
Англо-русский словарь нормативно-технической терминологии > time-current characteristic
8 critical load current
критический ток нагрузки
Значение тока отключения в пределах диапазона условий эксплуатации, при котором время дуги заметно увеличивается.
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
critical load current
value of breaking current, within the range of service conditions, at which the arcing time is significantly extended
[IEC 60947-1, ed. 5.0 (2007-06)]FR
courant critique de charge
valeur de courant coupé, dans le domaine des conditions de service, à laquelle la durée d'arc est notablement étendue
[IEC 60947-1, ed. 5.0 (2007-06)]Тематики
- выключатель автоматический
- выключатель, переключатель
- электротехника, основные понятия
EN
FR
Англо-русский словарь нормативно-технической терминологии > critical load current
9 weak-current arcing fault
Большой англо-русский и русско-английский словарь > weak-current arcing fault
10 weak-current arcing fault
Англо-русский словарь технических терминов > weak-current arcing fault
11 weak-current arcing fault
Техника: маломощное дуговое замыканиеУниверсальный англо-русский словарь > weak-current arcing fault
12 weak-current arcing fault
Англо-русский словарь по машиностроению > weak-current arcing fault
13 arc-proof low voltage switchgear and controlgear assembly
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof low voltage switchgear and controlgear assembly
14 arc-proof switchboard
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof switchboard
15 arc-proof switchgear
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-proof switchgear
16 arc-resistant switchgear
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > arc-resistant switchgear
17 internal arc-proof switchgear and controlgear assemblу
НКУ с защитой от воздействия электрической дуги
комплектное устройство с защитой от электрической дуги
низковольтное комплектное устройство с защитой от электрической дуги
НКУ распределения и управления с защитой от электрической дуги
-
[Интент]EN
arc-resistant switchgear
A type of switchgear design which is designed to withstand the effects of an internal arcing fault, without causing harm to personnel who are located in defined areas. It is not intended to withstand these internal arcing fault without possibly causing physical damage to the structure and/or components, but often the physical damage is less with an arc-resistant design.
There are three classes of protection:
Type A - eliminates the emission of gases and particles from the front of the switchgear during an internal arcing fault,
Type B - eliminates the emission of gases and particles from the front and sides of the switchgear during an internal arcing fault,
Type C - eliminates the emission of gases and particles from the front and sides of the switchgear, from between compartments within the same cell, and between adjacent cells during an internal arcing fault.
Arc-resistant switchgear has traditionally been metal-clad, but the basic concept could also be applied to other types of switchgear as well.
arc-proof switchgear
An incorrect term. Please refer to arc-resistant switchgear
[Schneider Electric]
[ http://electrical-engineering-portal.com/glossary-of-medium-voltage-switchgear-terms]Параллельные тексты EN-RU
If the electric arc occurs inside LV switchgear it generates internal overpressures and results in local overheatings which may cause high mechanical and thermal stresses in the equipment.
Besides, the involved materials can generate hot decomposition products, gases or fumes, which, due to the overpressure, are almost always ejected to the outside of the enclosure thus jeopardizing the operator safety.
The European Directive 2006/95/EC states the fundamental safety requirements for low voltage electric materials (from 50 V to 1000 V in alternating current, from 75 V to 1500 V in continuos current) to be put on the market within the European Community.
Among the essential safety requirements defined by this Directive particular importance is given to the need of taking technical measures to prevent “temperature rises, electric arcs or radiations which may result in hazards” from occurring.
This aspect has always been highly considered for apparatus, but it has been wrongly neglected for electrical switchgear and only in the last 10-15 years it has been catching on both at Italian as well as at international level.
Safety for the operator and for the installation in case of arcing inside LV switchgear can be obtained through three different design philosophies:
1. assemblies mechanically capable of withstanding the electric arc (passive protection)
2. assemblies equipped with devices limiting the effects of internal arcing (active protection)
3. assemblies equipped with current limiting circuitbreakers.
These three solutions (also combined together) have found a remakable development in the industrial field and have been successfully applied by the main manufacturers of LV switchgear and controlgear assemblies.
As it can be seen hereafter by examining the first two solutions, an “active” protection against arc faults is intrinsecally more complex than a “passive” one.
This because of the presence of additional electromechanical/ electronic devices5 which limit the arcing effects and which, by their nature, may be subject to faults or not-tripping.
[ABB]Дуга, возникшая внутри НКУ, создает внутреннее избыточное давление и вызывает локальный перегрев, что может привести к воздействию на оборудование значительного механического напряжения и перепада температур.
Кроме того, под воздействием дуги различные материалы разлагаются на продукты, имеющие высокую температуру, в том числе газы и дым, которые почти всегда вырываются из оболочки НКУ под высоким давлением, подвергая опасности оперативный персонал.
Европейская директива 2006/95/EC определяет основные требования безопасности для низковольтного (от 50 до 1000 В переменного тока и от 75 до 1500 В постоянного тока) оборудования поставляемого на рынок Европейского Сообщества.
Одно из основных требований безопасности, определяемое данной директивой как наиболее важное, заключается в необходимости предпринять технические меры для предотвращения "подъема температуры, возникновения электрической дуги или излучения", которые могут причинить ущерб.
Данная проблема всегда учитывалась при создании различных аппаратов, но незаслуженно игнорировалась при разработке электрических комплектных устройств, и только в последние 10-15 лет ей стали уделять должное внимание как в Италии, так и во всем мире.
При возникновении электрической дуги внутри НКУ безопасность оператора и электроустановки обеспечивается тремя способами:
1. Конструкция НКУ должна выдерживать механические воздействия, возникающие при горении электрической дуги (пассивная защита).
2. НКУ должно быть оснащено устройствами, ограничивающими воздействие электрической дуги (активная защита)
3. НКУ должны быть оснащены токоограничивающими автоматическими выключателями.
Указанные три способа (применяемые совместно) получили дальнейшее развитие в промышленности и успешно применяются основными изготовителями НКУ распределения и управления.
Как будет показано далее при рассмотрении первых двух способов, активная защита от дуговых» неисправностей является более сложной, чем пассивная защита.
Это объясняется необходимостью использования дополнительных электромеханических или электронных устройств, задачей которых является ограничение воздействий дуги и которые сами могут оказаться неисправными и не сработать.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
Синонимы
- комплектное устройство с защитой от электрической дуги
- низковольтное комплектное устройство с защитой от электрической дуги
- НКУ распределения и управления с защитой от электрической дуги
EN
Англо-русский словарь нормативно-технической терминологии > internal arc-proof switchgear and controlgear assemblу
18 arc extinction time
время дуги
Время между моментами возникновения и окончательного погасания дуги.
[ ГОСТ Р 50339. 0-2003 ( МЭК 60269-1-98)]EN
arcing time
interval of time between the instant of the initiation of the arc and the instant of final arc extinction
[IEC 60127-1, ed. 2.0 (2006-06)]
arcing time
interval of time between the instant of the initiation of the arc between the arcing contacts and the instant of final arc extinction
[IEC 60077-3, ed. 1.0 (2001-12)]
arcing time
interval of time between the instant of the initiation of the arc in a fuse and the instant of final arc extinction in that fuse
[IEC 60077-5, ed. 1.0 (2003-07)]
arcing time
interval of time between the instant of the initiation of the arc in a pole or a fuse and the instant of final arc extinction in that pole or that fuse
[IEC 60282-2, ed. 3.0 (2008-04)]FR
durée d’arc
intervalle de temps entre l’instant du début de l’arc entre les contacts de coupure et l’instant de l’extinction finale de l’arc
[IEC 60077-3, ed. 1.0 (2001-12)]
durée d’arc
intervalle de temps entre l'instant de début de l'arc dans un fusible et l'instant de l'extinction finale de l'arc dans ce fusible
[IEC 60077-5, ed. 1.0 (2003-07)]
durée d’arc
intervalle de temps entre l’instant de début de l’arc sur un pôle ou sur un fusible et l’instant de l’extinction finale de l’arc sur ce pôle ou ce fusible
[IEC 60282-2, ed. 3.0 (2008-04)]Параллельные тексты EN-RU
Thanks to the new arcing chambers, the arc extinction time has been reduced, thereby guaranteeing high short-circuit current limitation.
[ABB]Благодаря применению новых дугогасительных камер уменьшено время дуги, вследствие чего гарантируется ограничение больших значений токов короткого замыкания.
[Перевод Интент]Тематики
- выключатель автоматический
- высоковольтный аппарат, оборудование...
- предохранитель
EN
FR
Англо-русский словарь нормативно-технической терминологии > arc extinction time
19 breaking time
время срабатывания (автоматического выключателя)
-
[Интент]
время расцепления
-
[IEV ref 442-05-53]EN
tripping time
the time interval from the instant at which the associated tripping current begins to flow in the main circuit to the instant when this current is interrupted (in all poles)
[IEV ref 442-05-53]FR
temps de déclenchement
intervalle de temps entre le moment où le courant de déclenchement associé commence à circuler dans le circuit principal et le moment où le courant est interrompu (dans tous les pôles)
[IEV ref 442-05-53]2.3.10. Выключатели с максимальными расцепителями токов должны быть термически и динамически стойкими во всем диапазоне токов, вплоть до токов, установленных в технических условиях на выключатели конкретных серий и типов, характеризующих наибольшие включающую и отключающую способности при регламентированном для выключателей времени срабатывания и заданных параметрах цепи.
2.3.12.3. Токи срабатывания и несрабатывания выключателей с максимальными расцепителями тока, с обратно зависимой от тока выдержкой времени, а также их собственные времена срабатывания и несрабатывания в процессе эксплуатации в условиях, установленных в настоящем стандарте, должны устанавливаться в технических условиях на выключатели конкретных серий и типов
Для расцепителя с замедлением времени срабатывания при восстановлении напряжения от 0,9 номинального в течение 0,66 заданного времени срабатывания не должно происходить отключения выключателя, и система расцепления должна возвратиться в исходное положение, соответствующее состоянию расцепителя при его номинальном напряжении.
время срабатывания максимальных расцепителей тока в зоне токов перегрузки при 2,5-кратной уставке по току не превышает времени, установленного для двукратной уставки по току для выключателей категории Р-1, и времени, указанного для выключателей категории Р-2;
[ ГОСТ 9098-78]
551.4.3.3.1 Если защита от короткого замыкания для частей установки, электропитание на которые подается от статического инвертора, основывается на автоматическом включении выключателя байпаса и время срабатывания защитных устройств на питающей стороне выключателя байпаса более времени, установленного в разделе 411 МЭК 60364-4-41 [ 2 ], должно быть обеспечено дополнительное уравнивание потенциалов между одновременно доступными открытыми проводящими частями и сторонними проводящими частями на стороне нагрузки статического инвертора в соответствии с пунктом 415.2 МЭК 60364-4-41 [ 2 ].
[ ГОСТ Р 50571. 29-2009 ( МЭК 60364-5-55: 2008)]
Тематики
EN
DE
- Auslösedauer, f
FR
время отключения
Интервал времени между началом времени размыкания контактного коммутационного аппарата (или преддугового времени плавкого предохранителя) и моментом угасания дуги.
МЭК 60050(441-17-39).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
полное время отключения
Интервал времени между началом операции отключения и окончанием погасания дуги во всех полюсах.
[ ГОСТ Р 52565-2006]
полное время отключения выключателя
Время срабатывания расцепителей, механизма выключателя, расхождения силовых контактов и окончания гашения дуги в дугогасительных камерах (используется при проверке селективности защиты).
[А.В.Беляев. Выбор аппаратуры, защит и кабелей в сетях 0,4 кВ. - Л.: Энергоатомиздат. 1988.]EN
break-time
the interval of time between the beginning of the opening time of a mechanical switching device (or the pre-arcing time of a fuse) and the end of the arcing time
[IEV number 441-17-39]FR
durée de coupure
intervalle de temps entre le début de la durée d'ouverture d'un appareil mécanique de connexion, ou le début de la durée de préarc d'un fusible, et la fin de la durée d'arc
[IEV number 441-17-39]См. также собственное время отключения

Параллельные тексты EN-RU 1
Breaker closed - apply auxillary power to activate the release.
Выключатель во включенном положении. Начинает прикладываться внешнее усилие, направленное на отключение.
2
Contact separation - start of arc.
Наличие зазора между разомкнутыми контактами. Возникновение дуги.
3
Extinction of arc.
Погасание дуги.
4
Breacer open - initiation of closing movement.
Выключатель в отключенном положении. Инициирование включения.
5
Current starts to flow in the conducting path (preignition)
Начало протекания тока (начало горения дуги в изоляционном промежутке между разомкнутыми контактами).
6
Contact touch.
Соприкосновение контактов.
-
Opening time.
Собственное время отключения.
-
Arcing time
Время дуги.
-
Make time.
Время включения.
-
Break time/Interrupting time
-
Dead time.
Бестоковая пауза.
-
Closing time.
Собственное время включения.
-
Reclosing time.
Цикл автоматического повторного включения.
[Siemens]
[Перевод Интент]
Тематики
- аппарат, изделие, устройство...
- выключатель автоматический
- выключатель, переключатель
Синонимы
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > breaking time
20 assembly equipped with devices limiting internal arc effects
НКУ с устройствами ограничения воздействия внутренней дуги
-
[Интент]Параллельные тексты EN-RU
Assemblies equipped with devices limiting internal arc effects (active protection)
A design philosophy which is completely different from that just considered consists in guaranteeing the resistance to internal arcing by installing devices limiting the arc.
The approaches in that direction can be of two different types:
• limiting the destructive effects of the arc, once it has occured, by means of arc detectors
• limiting the destructive effects of the arc, once it has occured, by means of overpressure detectors.
The first possibility consists in installing in the assembly arc detectors which sense the light flux associated with the electric arc phenomenon.
Once the arc has been detected, these devices send an opening signal to the incoming circuit-breaker, thus guaranteeing tripping times of the order of 1-2 ms, therefore shorter than those proper of the circuit-breaker.
The operating logic of an arc detector is the following: the occurrence of an arc inside the switchboard is detected by the arc detector because an intense light radiation is associated with this phenomenon.
The arcing control system detects the event and sends a tripping signal to the circuit-breaker.
All the above with trip times of a few milliseconds and supplanting the tripping of the CB overcurrent relay which, for example, could be delayed due to current selectivity questions.
Figure 1 shows the possible positions where this device can be installed inside a switchboard.
The ideal solution is that which provides the installation of at least one detector for each column, with the consequent reduction to a minimum of the length of the optical fibers carrying the signal.
In order to prevent from an unwanted tripping caused by light sources indepent of the arc (lamps, solar radiation etc.), an additional current sensor is often positioned at the incoming of the main circuit-breaker.
Only in the event of an arc, both the incoming sensor which detects an “anomalous” current due to the arc fault as well as the sensor detecting the light radiation as sociated with the arc enable the system to intervene and allow the consequent opening of the circuit-breaker.
The second possibility consists in installing overpressure sensors inside the switchboard.
As previously described, the overpressure wave is one of the other effects occurring inside an assembly in case of arcing.
As a consequence it is possible to install some pressure sensors which are able to signal the pressure peak associated with the arc ignition with a delay of about 10-15 ms.
The signal operates on the supply circuit-breaker without waiting for the trip times of the selectivity protections to elapse, which are necessarily longer.
Such a system does not need any electronic processing device, since it acts directly on the tripping coil of the supply circuit-breaker.
Obviously it is essential that the device is set at fixed trip thresholds.
When an established internal overpressure is reached, the arc detector intervenes.
However, it is not easy to define in advance the value of overpressure generated by an arc fault inside a switchboard.
[ABB]НКУ с устройствами ограничения воздействия внутренней дуги (активная защита)
Для решения этой задачи используются совершенно другие, отличающиеся от ранее рассмотренных, принципы, заключающиеся в том, что противодействие внутренней дуге обеспечивается применением устройств, ограничивающих саму дугу.
Существует два типа решения проблемы в этом направлении:
• ограничение разрушающего воздействия дуги после того, как ее обнаружат специальные устройства
• ограничение разрушающего воздействия дуги после того, как специальные устройства обнаружат возникновение избыточного давления.
В первом случае в НКУ устанавливают устройства обнаружения дуги, реагирующие на световой поток, сопровождающий явление электрической дуги.
При обнаружении дуги данные устройства посылают сигнал управления на размыкание вводного автоматического выключателя. Гарантируемое время реакции составляет 1-2 мс, что меньше времени срабатывания автоматического выключателя.
Логика работы устройства обнаружения дуги следующая: Дуга, возникшая внутри НКУ, обнаруживается датчиком, реагирующим на интенсивное световое излучение, которым сопровождается горение дуги.
Обнаружив дугу, система управления посылает сигнал автоматическому выключателю.
Время срабатывания датчика и системы управления составляет несколько миллисекунд, что меньше времени срабатывания автоматического выключателя, осуществляющего защиту от сверхтока, который обычно для обеспечения требуемой селективности срабатывает с задержкой.
На рис. 1 показаны места возможной установки устройства защиты внутри НКУ.
Идеальным решением является установка, по крайней мере, одного устройства защиты в каждый шкаф многошкафного НКУ.
Это позволит до минимума сократить длину оптоволоконных кабелей передачи сигнала.
Для предотвращения ложного срабатывания от других источников света (т. е. не от дуги), например, таких как лампы, солнечное излучение и т. п., дополнительно в главной цепи вводного автоматического выключателя устанавливают датчик тока.
Только при наличии двух событий, а именно: срабатывания датчика света и обнаружения аномального увеличения тока, система управления считает, что возникла электрическая дуга и подает команду на отключение вводного автоматического выключателя.
Второе решение заключается в установке внутри НКУ датчика избыточного давления.
Как было описано ранее, одним из характерных проявлений электрической дуги, возникшей внутри НКУ, является ударная волна.
Это означает, что можно установить несколько датчиков давления, задачей которых является обнаружение импульса давления (с задержкой 10…15 мс), обусловленного зажиганием дуги.
Сигнал от датчиков давления поступает на вводной автоматический выключатель, который срабатывает без задержки на обеспечение селективности.
Такая система не нуждается в электронном устройстве обработки информации, поскольку воздействует непосредственно на независимый расцепитель автоматического выключателя.
Вполне понятно, что такое устройство имеет фиксированный порог срабатывания.
Датчик-реле дуги сработает, как только будет достигнуто заданное значение избыточного давления.
Следует иметь в виду, что не так легко заранее определить значение избыточного давления, которое будет создано при зажигании дуги внутри НКУ.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
EN
Англо-русский словарь нормативно-технической терминологии > assembly equipped with devices limiting internal arc effects
СтраницыСм. также в других словарях:
Current transformer — A CT for operation on a 110 kV grid In electrical engineering, a current transformer (CT) is used for measurement of electric currents. Current transformers, together with voltage transformers (VT) (potential transformers (PT)), are known as … Wikipedia
Residual-current device — A two pole residual current device A Residual Current Device is a generic term covering both RCCBs and RCBOs. A Residual Current Circuit Breaker (RCCB) is an electrical wiring device that disconnects a circuit whenever it detects that the… … Wikipedia
High-voltage direct current — HVDC or high voltage, direct current electric power transmission systems contrast with the more common alternating current systems as a means for the bulk transmission of electrical power. The modern form of HVDC transmission uses technology… … Wikipedia
Arc-fault circuit interrupter — An arc fault circuit interrupter (AFCI) is a circuit breaker designed to prevent fires by detecting non working electrical arcs and disconnect power before the arc starts a fire. The AFCI should distinguish between a working arc that may occur in … Wikipedia
Relay — This article is about the electrical component. For other uses, see Relay (disambiguation). Automotive style miniature relay, dust cover is taken off A relay is an electrically operated switch. Many relays use an electromagnet to operate a… … Wikipedia
Electric arc — An electric arc is an electrical breakdown of a gas which produces an ongoing plasma discharge, resulting from a current flowing through normally nonconductive media such as air. A synonym is arc discharge. The phenomenon was first described by… … Wikipedia
НКУ с защитой от воздействия электрической дуги — комплектное устройство с защитой от электрической дуги низковольтное комплектное устройство с защитой от электрической дуги НКУ распределения и управления с защитой от электрической дуги [Интент] EN arc resistant switchgear A type of switchgear… … Справочник технического переводчика
Diaphragm (contraceptive) — Diaphragm 1: bladder, 2: pubic bone, 3: urethra, 4: vagina, 5: uterus, 6: fornix, 7: cervix, 8: diaphragm, 9: rectum Background … Wikipedia
время — 3.3.4 время tE (time tE): время нагрева начальным пусковым переменным током IА обмотки ротора или статора от температуры, достигаемой в номинальном режиме работы, до допустимой температуры при максимальной температуре окружающей среды. Источник … Словарь-справочник терминов нормативно-технической документации
Vacuum tube — This article is about the electronic device. For experiments in an evacuated pipe, see free fall. For the transport system, see pneumatic tube. Modern vacuum tubes, mostly miniature style In electronics, a vacuum tube, electron tube (in North… … Wikipedia
Extra-low voltage — IEC voltage range AC DC defining risk High voltage (supply system) > 1000 Vrms > 1500 V electrical arcing Low voltage (supply system) 25–1000 Vrms 60–1500 V electrical shock Extra low voltage (supply system) < 25 V … Wikipedia
Перевод: с английского на русский
с русского на английский- С русского на:
- Английский
- С английского на:
- Все языки
- Немецкий