1 длительный допустимый ток
- Strombelastbarkeit, f
- Dauerstrombelastbarkeit, f
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Русско-немецкий словарь нормативно-технической терминологии > длительный допустимый ток
См. также в других словарях:
allowed value — leidžiamoji vertė statusas T sritis automatika atitikmenys: angl. allowed value; permitted value vok. zulässiger Wert, m rus. разрешенное значение, n pranc. valeur admissible, f; valeur légale, f; valeur permise, f … Automatikos terminų žodynas
allowed value — leidžiamoji vertė statusas T sritis fizika atitikmenys: angl. allowed value vok. zulässiger Wert, m rus. дозволенное значение, n; допустимое значение, n; разрешённое значение, n pranc. valeur admise, f; valeur admissible, f … Fizikos terminų žodynas
Allowed value — Допустимое значение … Краткий толковый словарь по полиграфии
Value Added Tax-free Exports from the Channel Islands — are exports of goods from the Channel Islands on which value added tax (VAT) is not levied. In recent years, companies in the United Kingdom have expressed concern at the competition thereby offered to their goods on which VAT is… … Wikipedia
Value change dump — is an ASCII based format for dumpfiles generated by EDA logic simulation tools. The standard, four value VCD format was defined along with the Verilog hardware description language by the IEEE Standard 1364 1995 in 1995. An Extended VCD format… … Wikipedia
Value added tax — Taxation An aspect of fiscal policy … Wikipedia
Value over replacement player — In baseball, value over replacement player (or VORP) is a statistic invented by Keith Woolner that demonstrates how much a hitter contributes offensively or how much a pitcher contributes to his team in comparison to a fictitious replacement… … Wikipedia
Value Added Tax in Madhya Pradesh — MADHYA PRADESH VALUE ADDED TAX ACTVAT Tax payable on value addition. Value Addition is not profit it is difference between sale prices and purchase price.METHODS OF CHARGING VAT1. Subtraction Method In this method tax is charged on difference of… … Wikipedia
value domain — noun The set of allowed values for a data element … Wiktionary
permitted value — leidžiamoji vertė statusas T sritis automatika atitikmenys: angl. allowed value; permitted value vok. zulässiger Wert, m rus. разрешенное значение, n pranc. valeur admissible, f; valeur légale, f; valeur permise, f … Automatikos terminų žodynas