1 длительный допустимый ток
- Strombelastbarkeit, f
- Dauerstrombelastbarkeit, f
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Русско-немецкий словарь нормативно-технической терминологии > длительный допустимый ток
См. также в других словарях:
allowable limit — leidžiamoji riba statusas T sritis fizika atitikmenys: angl. allowable limit; permissible limit vok. zulässige Grenze, f rus. допустимый предел, m pranc. limite admissible, f … Fizikos terminų žodynas
Limit state design — (LSD) refers to a design methodology used in structural engineering. The methodology is in fact a modernization and rationalization of engineering knowledge which was well established prior to the adoption of LSD. Beyond the concept of a limit… … Wikipedia
allowable — al‧low‧a‧ble [əˈlaʊəbl] adjective 1. acceptable according to the rules: • The government has cut by 35% this year s allowable catch of fish. 2. ACCOUNTING an allowable amount, cost, or expense does not need to be counted as part of income or… … Financial and business terms
limit — {{Roman}}I.{{/Roman}} noun ADJECTIVE ▪ outer ▪ northern, southern, etc. ▪ three mile, etc. ▪ city … Collocations dictionary
allowable — adj. Allowable is used with these nouns: ↑expense, ↑limit … Collocations dictionary
limit of error — didžiausia leidžiamoji paklaida statusas T sritis Standartizacija ir metrologija apibrėžtis Matavimo priemonės paklaidos norma, kurią nustato metrologijos taisyklės arba gamintojas. Didžiausia leidžiamoji paklaida rodo priemonės tikslumą.… … Penkiakalbis aiškinamasis metrologijos terminų žodynas
limit of error — didžiausioji leidžiamoji paklaida statusas T sritis fizika atitikmenys: angl. limit of error; maximum allowable error vok. Fehlergrenze, f rus. предельно допустимая погрешность, f pranc. erreur maximale permise, f; erreur maximale tolérée, f … Fizikos terminų žodynas
limit — A boundary or end. [L. limes, boundary] critical l. the upper or lower boundary of a laboratory test result that indicates a life threatening value. elastic l. the greatest stress to which a material may be subjected and still be capable of… … Medical dictionary
permissible limit — leidžiamoji riba statusas T sritis fizika atitikmenys: angl. allowable limit; permissible limit vok. zulässige Grenze, f rus. допустимый предел, m pranc. limite admissible, f … Fizikos terminų žodynas
price limit — The maximum advance or decline from the previous day s settlement permitted for a contract in one trading session by the rules of the exchange. According to the Chicago Board of Trade rules, an expanded allowable price range set during volatile… … Financial and business terms
variable limit — According to the Chicago Board of Trade rules, an expanded allowable price range set during volatile markets. Chicago Board of Trade glossary Most exchanges set limits on the maximum daily price movement of some of the futures contracts traded on … Financial and business terms