air+cooling+device

  • 1 длительный допустимый ток

    1. courant permanent admissible, m
    2. courant admissible, m

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-французский словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • Air cooling — In devices generating heat, such as gasoline engine motor vehicles, the cooling of the device by increasing its radiating surface by means of ribs or radiators, and placing it so that it is exposed to a current of air. Cf. {Water cooling}. {Air… …   The Collaborative International Dictionary of English

  • Air-cooled — Air cooling Air cooling In devices generating heat, such as gasoline engine motor vehicles, the cooling of the device by increasing its radiating surface by means of ribs or radiators, and placing it so that it is exposed to a current of air. Cf …   The Collaborative International Dictionary of English

  • cooling system — Apparatus used to keep the temperature of a structure or device from exceeding limits imposed by needs of safety and efficiency. In a mechanical transmission, the oil loses its lubricating capacity if overheated; in a hydraulic coupling or… …   Universalium

  • air-cool — verb equip with an apparatus for controlling the humidity and temperature Our house is not air conditioned • Syn: ↑air condition • Derivationally related forms: ↑air conditioner (for: ↑air condition), ↑air conditioning …   Useful english dictionary

  • Air Movement and Control Association — The Air Movement and Control Association International, Inc. (AMCA; pronounced Am Cah ) is a nonprofit organization that creates standards for, tests, and rates Heating, Ventilating, and Air Conditioning (HVAC) equipment. It is best known for its …   Wikipedia

  • air conditioner — noun a system that keeps air cool and dry • Syn: ↑air conditioning • Derivationally related forms: ↑air condition (for: ↑air conditioning), ↑air condition • Hypernyms: ↑ …   Useful english dictionary

  • Air brake (road vehicle) — Air brakes are used in trucks, buses, trailers, and semi trailers. George Westinghouse first developed air brakes for use in railway service. A safer air brake was patented by him on March 5, 1872. Originally constructed for use on trains, and… …   Wikipedia

  • Air gun — Air rifle and Air pistol redirect here. For other uses, see Air gun (disambiguation) An air gun (air rifle or air pistol) is a rifle or pistol which fires projectiles by means of compressed air or other gas, (in contrast to a firearm which uses… …   Wikipedia

  • Air pollution — from World War II production Smog over …   Wikipedia

  • cooling tower — Device which cools by water evaporation in air. Water is cooled to wet bulb temperature of air …   Dictionary of automotive terms

  • Air handler — An air handling unit; air flow is from the right to left in this case. Some AHU components shown are: 1 Supply duct 2 Fan compartment 3 Vibration isolator ( flex joint ) 4 Heating and/or cooling coil 5 Filter compartment 6 Mixed (recirculated +… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»