-
1 strip a wire (of its insulation)
Электроника: зачищать (провод от изоляции)Универсальный англо-русский словарь > strip a wire (of its insulation)
-
2 strip a wire of its insulation
Электроника: зачищать провод от изоляцииУниверсальный англо-русский словарь > strip a wire of its insulation
-
3 insulation
изолирование
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
электрическая изоляция
изоляция
Часть электротехнического устройства, электрически разделяющая его узлы и (или) детали.
[ ГОСТ 21515-76]
изоляция
-
[IEV number 151-15-41]
изоляция
-
[IEV number 151-15-42]EN
insulation (1)
all the materials and parts used to insulate conductive elements of a device
[IEV number 151-15-41]
insulation (2)
set of properties which characterize the ability of an insulation to provide its function
NOTE – Examples of relevant properties are: resistance, breakdown voltage.
Source: 151-15-41
[IEV number 151-15-42]FR
isolation, f
ensemble des matériaux et parties utilisés pour isoler des éléments conducteurs d'un dispositif
[IEV number 151-15-41]
isolement, m
ensemble des propriétés qui caractérisent l’aptitude d’une isolation à assurer sa fonction
NOTE – Des exemples de propriétés pertinentes sont la résistance, la tension de claquage.
[IEV number 151-15-42]Примечание - Изоляция может быть твердой, жидкой или газообразной (например, воздух), или представлять собой любую комбинацию указанных состояний.
[ ГОСТ Р МЭК 61140-2000]п ерекрытие по поверхности изоляции
Испытание изоляции полным испытательным напряжением
Тематики
- электрическая изоляция
- электротехника, основные понятия
Синонимы
Сопутствующие термины
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > insulation
-
4 ITS
1) Компьютерная техника: Information Technology Standard, integrated test system, Information Technical Security2) Биология: (internal transcribed spacer) внутренний транскрибируемый участок (разделяющий гены двух рРНК)3) Военный термин: Imagery Transmission System, Institute for Telecommunications Sciences, Integrated Test Schedule, improved third stage, infantry transportable Swingfire, infinite time span, information transfer satellite, information transfer system, infrared tracking system, initial training school, instrument time, simulated, integrated target system, integrated test specifications, intersectional transportation service4) Техника: Idaho Test Station, Institute for Telecommunication Science, important to safety, improved technical specification, instrumentation and telemetry system, intelligent terminal system, interactive terminal support, international telecommunications service, inventory tracking system5) Сельское хозяйство: infectious turkey sinusitis6) Юридический термин: Income Tax Service, Internal Transcribed Spacer7) Автомобильный термин: idle tracking switch8) Биржевой термин: (Information Trading System) ИТС (Информационно-торговая система)9) Политика: Instructional Technology Specialist10) Сокращение: Incompatible Timesharing System, Independent Target System, Initial Training Squadron (UK Royal Air Force), Institute for Telecommunication Sciences, Intelligent Tutoring System, Interactive Training System, International Temperature Scale, International Thermal Sight, International Trade Secretariat, insulation test specification, Международная служба розыска International Tracing Service11) Физиология: I'm Tired Syndrome12) Вычислительная техника: Incompatible Time-sharing System (DEC), International Telecommunications Society (organization)14) Банковское дело: Межрыночная торговая система (компьютерная система, связывающая биржи США; Intermarket Trading System)15) Транспорт: Intelligent Transportation System16) СМИ: Insertion Test Signal17) Деловая лексика: Integrated Technology Strategy18) Глоссарий компании Сахалин Энерджи: инструкция поставщику (Instruction to Supplier), Information Technology Services19) Инвестиции: Intermarket Trading System20) Автоматика: integrated tooling system21) Сахалин Р: Instruction to Supplier22) Расширение файла: Internet Document Set, Invitation To Send23) SAP.тех. ITS-сервер24) Высокочастотная электроника: intelligent transportation systems25) Программное обеспечение: Integrated Tertiary Software -
5 its
1) Компьютерная техника: Information Technology Standard, integrated test system, Information Technical Security2) Биология: (internal transcribed spacer) внутренний транскрибируемый участок (разделяющий гены двух рРНК)3) Военный термин: Imagery Transmission System, Institute for Telecommunications Sciences, Integrated Test Schedule, improved third stage, infantry transportable Swingfire, infinite time span, information transfer satellite, information transfer system, infrared tracking system, initial training school, instrument time, simulated, integrated target system, integrated test specifications, intersectional transportation service4) Техника: Idaho Test Station, Institute for Telecommunication Science, important to safety, improved technical specification, instrumentation and telemetry system, intelligent terminal system, interactive terminal support, international telecommunications service, inventory tracking system5) Сельское хозяйство: infectious turkey sinusitis6) Юридический термин: Income Tax Service, Internal Transcribed Spacer7) Автомобильный термин: idle tracking switch8) Биржевой термин: (Information Trading System) ИТС (Информационно-торговая система)9) Политика: Instructional Technology Specialist10) Сокращение: Incompatible Timesharing System, Independent Target System, Initial Training Squadron (UK Royal Air Force), Institute for Telecommunication Sciences, Intelligent Tutoring System, Interactive Training System, International Temperature Scale, International Thermal Sight, International Trade Secretariat, insulation test specification, Международная служба розыска International Tracing Service11) Физиология: I'm Tired Syndrome12) Вычислительная техника: Incompatible Time-sharing System (DEC), International Telecommunications Society (organization)14) Банковское дело: Межрыночная торговая система (компьютерная система, связывающая биржи США; Intermarket Trading System)15) Транспорт: Intelligent Transportation System16) СМИ: Insertion Test Signal17) Деловая лексика: Integrated Technology Strategy18) Глоссарий компании Сахалин Энерджи: инструкция поставщику (Instruction to Supplier), Information Technology Services19) Инвестиции: Intermarket Trading System20) Автоматика: integrated tooling system21) Сахалин Р: Instruction to Supplier22) Расширение файла: Internet Document Set, Invitation To Send23) SAP.тех. ITS-сервер24) Высокочастотная электроника: intelligent transportation systems25) Программное обеспечение: Integrated Tertiary Software -
6 rated insulation voltage
- паспортное напряжение изоляции
- номинальное напряжение изоляции (аппарата), Ui
- номинальное напряжение изоляции
номинальное напряжение изоляции (аппарата), Ui
Значение напряжения, по которому определяют испытательное напряжение при испытании изоляционных свойств, расстояние утечки и воздушные зазоры.
Максимальное значение номинального рабочего напряжения не должно превышать наибольшего значения номинального напряжения изоляции.
Примечание — Для аппарата, у которого номинальное напряжение изоляции не устанавливается, его следует принимать как наибольшее значение любого номинального напряжения
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
rated insulation voltage, Ui
value of voltage to which dielectric tests and creepage distances are referred
[IEC 62314, ed. 1.0 (2006-05)]
rated insulation voltage (RIV)
voltage value assigned by the manufacturer to the equipment or to a part of it, characterizing the specified (long-term) withstand capability of its insulation
NOTE 1 The rated insulation voltage is higher than or equal to the rated voltage of the equipment, or to the rated voltage of the concerned part of the equipment, which is primarily related to functional performance.
NOTE 2 The rated insulation voltage refers to the insulation between electric circuits, between live parts and exposed conductive parts and within an electric circuit.
NOTE 3 For clearances and solid insulation, the peak value of the voltage occurring across the insulation or clearance is the determining value for the rated insulation voltage. For creepage distances the r.m.s. value is the determining value
[IEC 62103, ed. 1.0 (2003-07)]FR
tension assignée d'isolement (TIA)
valeur efficace de la tension de tenue fixée par le constructeur au matériel ou à une de ses parties, caractérisant la capacité de tenue spécifiée (à long terme) de son isolation
NOTE 1 La tension assignée d'isolement est supérieure ou égale à la tension assignée du matériel ou de la partie concernée de l’appareil qui est principalement liée aux caractéristiques fonctionnelles.
NOTE 2 La tension d'isolement assignée se rapporte à l'isolation entre circuits électriques, entre parties conductrices et masses, et à l'intérieur du circuit électrique.
NOTE 3 Pour les distances d'isolement et pour les isolants solides, la tension d'isolement assignée est déterminée par la valeur de crête de la tension apparaissant aux bornes de l'isolant ou de la distance. Pour les lignes de fuites, c'est la tension efficace qu'il faut prendre
[IEC 62103, ed. 1.0 (2003-07)]Тематики
- аппарат, изделие, устройство...
- выключатель автоматический
EN
- rated insulation voltage
- rated insulation voltage, Ui
- RIV
FR
паспортное напряжение изоляции
-
[IEV number 312-06-02]EN
rated insulation voltage
working voltage assigned by the manufacturer of the instrument, to characterize its insulation
[IEV number 312-06-02]FR
tension d'isolement assignée
tension de travail fixée par le constructeur de l’appareil pour caractériser son isolation
[IEV number 312-06-02]EN
DE
FR
3.20 номинальное напряжение изоляции (rated insulation voltage): Значение действующего выдерживаемого напряжения, указанное изготовителем для оборудования или его части, характеризующее указанную (долгосрочную) прочность его изоляции.
[Определение 1.3.9.1 МЭК 60664-1].
Примечание - Номинальное напряжение изоляции не обязательно равно номинальному напряжению оборудования, которое прежде всего связано с функциональными характеристиками.
Источник: ГОСТ Р 52350.11-2005: Электрооборудование для взрывоопасных газовых сред. Часть 11. Искробезопасная электрическая цепь "I" оригинал документа
3.13 номинальное напряжение изоляции (rated insulation voltage), UНм (UNm): Напряжение при номинальной частоте, прикладываемое между выводом обмотки и какой-либо другой цепью или проводящей частью, находящейся вне обмотки.
Источник: ГОСТ Р 54801-2011: Трансформаторы тяговые и реакторы железнодорожного подвижного состава. Основные параметры и методы испытаний оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated insulation voltage
-
7 rated insulation voltage, Ui
- номинальное напряжение изоляции (аппарата), Ui
номинальное напряжение изоляции (аппарата), Ui
Значение напряжения, по которому определяют испытательное напряжение при испытании изоляционных свойств, расстояние утечки и воздушные зазоры.
Максимальное значение номинального рабочего напряжения не должно превышать наибольшего значения номинального напряжения изоляции.
Примечание — Для аппарата, у которого номинальное напряжение изоляции не устанавливается, его следует принимать как наибольшее значение любого номинального напряжения
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
rated insulation voltage, Ui
value of voltage to which dielectric tests and creepage distances are referred
[IEC 62314, ed. 1.0 (2006-05)]
rated insulation voltage (RIV)
voltage value assigned by the manufacturer to the equipment or to a part of it, characterizing the specified (long-term) withstand capability of its insulation
NOTE 1 The rated insulation voltage is higher than or equal to the rated voltage of the equipment, or to the rated voltage of the concerned part of the equipment, which is primarily related to functional performance.
NOTE 2 The rated insulation voltage refers to the insulation between electric circuits, between live parts and exposed conductive parts and within an electric circuit.
NOTE 3 For clearances and solid insulation, the peak value of the voltage occurring across the insulation or clearance is the determining value for the rated insulation voltage. For creepage distances the r.m.s. value is the determining value
[IEC 62103, ed. 1.0 (2003-07)]FR
tension assignée d'isolement (TIA)
valeur efficace de la tension de tenue fixée par le constructeur au matériel ou à une de ses parties, caractérisant la capacité de tenue spécifiée (à long terme) de son isolation
NOTE 1 La tension assignée d'isolement est supérieure ou égale à la tension assignée du matériel ou de la partie concernée de l’appareil qui est principalement liée aux caractéristiques fonctionnelles.
NOTE 2 La tension d'isolement assignée se rapporte à l'isolation entre circuits électriques, entre parties conductrices et masses, et à l'intérieur du circuit électrique.
NOTE 3 Pour les distances d'isolement et pour les isolants solides, la tension d'isolement assignée est déterminée par la valeur de crête de la tension apparaissant aux bornes de l'isolant ou de la distance. Pour les lignes de fuites, c'est la tension efficace qu'il faut prendre
[IEC 62103, ed. 1.0 (2003-07)]Тематики
- аппарат, изделие, устройство...
- выключатель автоматический
EN
- rated insulation voltage
- rated insulation voltage, Ui
- RIV
FR
Англо-русский словарь нормативно-технической терминологии > rated insulation voltage, Ui
-
8 elastomeric insulation
эластомерная изоляция
изоляция из материала, который деформируется при незначительном механическом воздействии и возвращается о свое первоначальное состояние после снятия этого воздействия
Примечание. Эта изоляция обычно сшитая, но может быть также термопластичной
[IEV number 461-02-13]EN
elastomeric insulation
insulation made of a material that deforms under low mechanical stress and returns to its original state upon release of that stress
NOTE – This insulation is normally cross-linked but it may also be thermoplastic.
[IEV number 461-02-13]FR
isolation élastomère
isolation constituée d'un matériau qui se déforme sous l'action d'une faible contrainte mécanique et reprend sa forme initiale lorsque la contrainte cesse d'agir
NOTE – Cette isolation, généralement réticulée, peut être également thermoplastique.
[IEV number 461-02-13]Тематики
- кабели, провода...
EN
DE
- elastomere Isolierung, f
FR
Англо-русский словарь нормативно-технической терминологии > elastomeric insulation
-
9 continuous current-carrying capacity
длительная пропускная способность по току
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Англо-русский словарь нормативно-технической терминологии > continuous current-carrying capacity
-
10 ampacity (US)
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Англо-русский словарь нормативно-технической терминологии > ampacity (US)
-
11 continuous current
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
непрерывный ток
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999]Тематики
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > continuous current
-
12 current-carrying capacity
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
предельно допустимый ток
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
прочность печатной платы к токовой нагрузке
Свойство печатной платы сохранять электрические и механические характеристики после воздействия максимально допустимой токовой нагрузки на печатный проводник или металлизированное отверстие печатной платы.
[ ГОСТ Р 53386-2009]Тематики
EN
Англо-русский словарь нормативно-технической терминологии > current-carrying capacity
-
13 RIV
- номинальное напряжение изоляции (аппарата), Ui
номинальное напряжение изоляции (аппарата), Ui
Значение напряжения, по которому определяют испытательное напряжение при испытании изоляционных свойств, расстояние утечки и воздушные зазоры.
Максимальное значение номинального рабочего напряжения не должно превышать наибольшего значения номинального напряжения изоляции.
Примечание — Для аппарата, у которого номинальное напряжение изоляции не устанавливается, его следует принимать как наибольшее значение любого номинального напряжения
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]EN
rated insulation voltage, Ui
value of voltage to which dielectric tests and creepage distances are referred
[IEC 62314, ed. 1.0 (2006-05)]
rated insulation voltage (RIV)
voltage value assigned by the manufacturer to the equipment or to a part of it, characterizing the specified (long-term) withstand capability of its insulation
NOTE 1 The rated insulation voltage is higher than or equal to the rated voltage of the equipment, or to the rated voltage of the concerned part of the equipment, which is primarily related to functional performance.
NOTE 2 The rated insulation voltage refers to the insulation between electric circuits, between live parts and exposed conductive parts and within an electric circuit.
NOTE 3 For clearances and solid insulation, the peak value of the voltage occurring across the insulation or clearance is the determining value for the rated insulation voltage. For creepage distances the r.m.s. value is the determining value
[IEC 62103, ed. 1.0 (2003-07)]FR
tension assignée d'isolement (TIA)
valeur efficace de la tension de tenue fixée par le constructeur au matériel ou à une de ses parties, caractérisant la capacité de tenue spécifiée (à long terme) de son isolation
NOTE 1 La tension assignée d'isolement est supérieure ou égale à la tension assignée du matériel ou de la partie concernée de l’appareil qui est principalement liée aux caractéristiques fonctionnelles.
NOTE 2 La tension d'isolement assignée se rapporte à l'isolation entre circuits électriques, entre parties conductrices et masses, et à l'intérieur du circuit électrique.
NOTE 3 Pour les distances d'isolement et pour les isolants solides, la tension d'isolement assignée est déterminée par la valeur de crête de la tension apparaissant aux bornes de l'isolant ou de la distance. Pour les lignes de fuites, c'est la tension efficace qu'il faut prendre
[IEC 62103, ed. 1.0 (2003-07)]Тематики
- аппарат, изделие, устройство...
- выключатель автоматический
EN
- rated insulation voltage
- rated insulation voltage, Ui
- RIV
FR
Англо-русский словарь нормативно-технической терминологии > RIV
-
14 strip a wire
1) Техника: зачищать провод2) Электроника: (of its insulation) зачищать (провод от изоляции)3) Макаров: зачищать провод (снимать изоляцию) -
15 rated impulse voltage
номинальное импульсное напряжение
Напряжение, определяемое на основе номинального напряжения и категории перенапряжения электроприбора, характеризующих установленную способность его изоляции выдерживать кратковременные перенапряжения.
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]EN
rated impulse voltage
voltage derived from the rated voltage and the overvoltage category of the appliance, characterizing the specified withstand capability of its insulation against transient overvoltages
[IEC 60335-1, ed. 4.0 (2001-05)]FR
tension assignée de tenue aux chocs
tension déduite de la tension assignée et de la catégorie de surtension de l’appareil, caractérisant la capacité de tenue spécifiée de son isolation contre des surtensions transitoires
[IEC 60335-1, ed. 4.0 (2001-05)]Тематики
EN
FR
Англо-русский словарь нормативно-технической терминологии > rated impulse voltage
-
16 insulated conductor
- изолированный проводник
- изолированный провод
- изолированная жила (термин употребляется в Северной Америке)
изолированная жила (термин употребляется в Северной Америке)
совокупность элементов, состоящая из жилы, ее изоляции (и экранов, если они есть)
Примечание. В Северной Америке термин «core of a cable» определяется как совокупность компонентов кабеля, расположенных под общим защитным покровом, таким как оболочка. Такое применение этого термина не допустимо
[IEV number 461-04-04]EN
core
insulated conductor
assembly comprising a conductor with its own insulation (and screens if any)
NOTE – In North American usage, the core of a cable has been defined as the assembly of components of a cable lying under a common covering such as the sheath. Such usage is deprecated.
[IEV number 461-04-04]FR
conducteur (isolé)
ensemble comprenant l'âme, son enveloppe isolante et ses écrans éventuels
NOTE – En Amérique du Nord le terme “core of a cable” a été défini comme l'ensemble des constituants d'un câble disposés sous un revêtement commun, tel que la gaine. L'utilisation de ce terme est déconseillée dans ce sens.
[IEV number 461-04-04]Тематики
- кабели, провода...
EN
DE
- Ader, f
FR
изолированный провод
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]EN
core insulated conductor
assembly comprising a conductor and its own insulation (and screens, if any)
[IEC 61892-4, ed. 1.0 (2007-06)]
core-insulated conductor (North America)
assembly comprising a conductor and its own insulation (and screens, if any)
NOTE In North American usage, the core of a cable has been defined as the assembly of components of a cable lying under a common covering such as the sheath (jacket).
[IEC 60092-350, ed. 3.0 (2008-02)]FR
conducteur (isolé)
ensemble comprenant l'âme, son enveloppe isolante et ses écrans éventuels
Note – En Amérique du Nord le terme “core of a cable” a été défini comme l'ensemble des constituants d'un câble disposés sous un revêtement commun, tel que la gaine. L'utilisation de ce terme est déconseillée dans ce sens.
[ IEV ref 461-04-04]Рис. Schneider Electric
Параллельные тексты EN-RU
An insulated conductor is made up of a conductor core and its
insulating envelope.
[Schneider Electric]Изолированный провод состоит из токопроводящей жилы и изоляции провода.
[Перевод Интент]Тематики
- кабели, провода...
EN
- core insulated conductor
- core-insulated conductor
- covered conductor
- covered wire
- insulated conductor
DE
- Ader, f
FR
изолированный проводник
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > insulated conductor
-
17 core insulated conductor
изолированный провод
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]EN
core insulated conductor
assembly comprising a conductor and its own insulation (and screens, if any)
[IEC 61892-4, ed. 1.0 (2007-06)]
core-insulated conductor (North America)
assembly comprising a conductor and its own insulation (and screens, if any)
NOTE In North American usage, the core of a cable has been defined as the assembly of components of a cable lying under a common covering such as the sheath (jacket).
[IEC 60092-350, ed. 3.0 (2008-02)]FR
conducteur (isolé)
ensemble comprenant l'âme, son enveloppe isolante et ses écrans éventuels
Note – En Amérique du Nord le terme “core of a cable” a été défini comme l'ensemble des constituants d'un câble disposés sous un revêtement commun, tel que la gaine. L'utilisation de ce terme est déconseillée dans ce sens.
[ IEV ref 461-04-04]Рис. Schneider Electric
Параллельные тексты EN-RU
An insulated conductor is made up of a conductor core and its
insulating envelope.
[Schneider Electric]Изолированный провод состоит из токопроводящей жилы и изоляции провода.
[Перевод Интент]Тематики
- кабели, провода...
EN
- core insulated conductor
- core-insulated conductor
- covered conductor
- covered wire
- insulated conductor
DE
- Ader, f
FR
Англо-русский словарь нормативно-технической терминологии > core insulated conductor
-
18 core-insulated conductor
изолированный провод
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]EN
core insulated conductor
assembly comprising a conductor and its own insulation (and screens, if any)
[IEC 61892-4, ed. 1.0 (2007-06)]
core-insulated conductor (North America)
assembly comprising a conductor and its own insulation (and screens, if any)
NOTE In North American usage, the core of a cable has been defined as the assembly of components of a cable lying under a common covering such as the sheath (jacket).
[IEC 60092-350, ed. 3.0 (2008-02)]FR
conducteur (isolé)
ensemble comprenant l'âme, son enveloppe isolante et ses écrans éventuels
Note – En Amérique du Nord le terme “core of a cable” a été défini comme l'ensemble des constituants d'un câble disposés sous un revêtement commun, tel que la gaine. L'utilisation de ce terme est déconseillée dans ce sens.
[ IEV ref 461-04-04]Рис. Schneider Electric
Параллельные тексты EN-RU
An insulated conductor is made up of a conductor core and its
insulating envelope.
[Schneider Electric]Изолированный провод состоит из токопроводящей жилы и изоляции провода.
[Перевод Интент]Тематики
- кабели, провода...
EN
- core insulated conductor
- core-insulated conductor
- covered conductor
- covered wire
- insulated conductor
DE
- Ader, f
FR
Англо-русский словарь нормативно-технической терминологии > core-insulated conductor
-
19 covered conductor
изолированный провод
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]EN
core insulated conductor
assembly comprising a conductor and its own insulation (and screens, if any)
[IEC 61892-4, ed. 1.0 (2007-06)]
core-insulated conductor (North America)
assembly comprising a conductor and its own insulation (and screens, if any)
NOTE In North American usage, the core of a cable has been defined as the assembly of components of a cable lying under a common covering such as the sheath (jacket).
[IEC 60092-350, ed. 3.0 (2008-02)]FR
conducteur (isolé)
ensemble comprenant l'âme, son enveloppe isolante et ses écrans éventuels
Note – En Amérique du Nord le terme “core of a cable” a été défini comme l'ensemble des constituants d'un câble disposés sous un revêtement commun, tel que la gaine. L'utilisation de ce terme est déconseillée dans ce sens.
[ IEV ref 461-04-04]Рис. Schneider Electric
Параллельные тексты EN-RU
An insulated conductor is made up of a conductor core and its
insulating envelope.
[Schneider Electric]Изолированный провод состоит из токопроводящей жилы и изоляции провода.
[Перевод Интент]Тематики
- кабели, провода...
EN
- core insulated conductor
- core-insulated conductor
- covered conductor
- covered wire
- insulated conductor
DE
- Ader, f
FR
Англо-русский словарь нормативно-технической терминологии > covered conductor
-
20 covered wire
изолированный провод
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]EN
core insulated conductor
assembly comprising a conductor and its own insulation (and screens, if any)
[IEC 61892-4, ed. 1.0 (2007-06)]
core-insulated conductor (North America)
assembly comprising a conductor and its own insulation (and screens, if any)
NOTE In North American usage, the core of a cable has been defined as the assembly of components of a cable lying under a common covering such as the sheath (jacket).
[IEC 60092-350, ed. 3.0 (2008-02)]FR
conducteur (isolé)
ensemble comprenant l'âme, son enveloppe isolante et ses écrans éventuels
Note – En Amérique du Nord le terme “core of a cable” a été défini comme l'ensemble des constituants d'un câble disposés sous un revêtement commun, tel que la gaine. L'utilisation de ce terme est déconseillée dans ce sens.
[ IEV ref 461-04-04]Рис. Schneider Electric
Параллельные тексты EN-RU
An insulated conductor is made up of a conductor core and its
insulating envelope.
[Schneider Electric]Изолированный провод состоит из токопроводящей жилы и изоляции провода.
[Перевод Интент]Тематики
- кабели, провода...
EN
- core insulated conductor
- core-insulated conductor
- covered conductor
- covered wire
- insulated conductor
DE
- Ader, f
FR
Англо-русский словарь нормативно-технической терминологии > covered wire
См. также в других словарях:
ITS — • Incompatible Time Sharing System, Betriebssystem geschrieben für die PDP 10 am MIT • Intelligent Tutoring Systems, International Conference (informationswissenschaftl. Veoeffentlichungen) • Institute for Telecommunication Sciences ( > IEEE… … Acronyms
ITS — [1] Incompatible Time Sharing System, Betriebssystem geschrieben für die PDP 10 am MIT [2] Intelligent Tutoring Systems, International Conference (informationswissenschaftl. Veröffentlichungen) [3] Institute for Telecommunication Sciences ( >… … Acronyms von A bis Z
R-value (insulation) — The R value or R value is a measure of thermal resistance (K·m²/W) [Oak Ridge National Laboratory, [http://www.ornl.gov/sci/roofs+walls/insulation/ins 02.html Which Kind Of Insulation Is Best?] , retrieved 2008 07 13.] used in the building and… … Wikipedia
Building insulation materials — A selection of insulation materials can aid in building insulation. All of these are based on standard principles of thermal insulation. Materials used to reduce heat transfer by conduction, radiation or convection are employed in varying… … Wikipedia
Wool insulation — is made from sheep wool that is mechanically bonded together to form insulating batts and ropes. Batts are commonly used in timber frame buildings and ropes are primarily used between the logs in log homes. Wool insulation is used for both… … Wikipedia
Thermal insulation — The term thermal insulation can refer to materials used to reduce the rate of heat transfer, or the methods and processes used to reduce heat transfer.Heat energy can be transferred by conduction, convection, radiation or when undergoing a phase… … Wikipedia
Building insulation — refers broadly to any object in a building used as insulation for any purpose. Whilst the majority of insulation in buildings is for thermal purposes, the term also applies to acoustic insulation, fire insulation, and impact insulation. Often an… … Wikipedia
Cellulose insulation — The word cellulose comes from the French word for a living cellule and glucose, which is sugar. Insulation is low thermal conductivity material used to separate the internal climate and sounds of a building from external climate and sounds.… … Wikipedia
Installing building insulation — Due to the variety of building insulation materials available and the various building elements that may require insulation, there are a number of ways of installing building insulation.Where to insulateWhere to insulate depends on where your… … Wikipedia
Exterior insulation finishing system — Exterior insulation and finishing system (EIFS) is a type of building exterior wall cladding system that provides exterior walls with an insulated finished surface and waterproofing in an integrated composite material system. Contents 1… … Wikipedia
Multi-layer insulation — Closeup of Multi layer insulation from a satellite. The metal coated plastic layers and the scrim separator are visible. Multi layer insulation, or MLI, is thermal insulation composed of multiple layers of thin sheets often used on spacecraft. It … Wikipedia