Перевод: с русского на немецкий

с немецкого на русский

without+the+need+for

  • 1 длительный допустимый ток

    1. Strombelastbarkeit, f
    2. Dauerstrombelastbarkeit, f

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-немецкий словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • The Market for Liberty —   Cover of the hardback edition …   Wikipedia

  • Need for Speed — This article is about the game series. For the first Need for Speed video game, see The Need for Speed. For other uses, see Need for Speed (disambiguation). Need for Speed Current logo. Genres Racing …   Wikipedia

  • No Need for Bushido — banner Author(s) Alex Kolesar and Joseph Kovell Website …   Wikipedia

  • The Market for Lemons — The Market for Lemons: Quality Uncertainty and the Market Mechanism is a 1970 paper by the economist George Akerlof. It discusses information asymmetry, which occurs when the seller knows more about a product than the buyer. A lemon is an… …   Wikipedia

  • The center for arts education — (CAE) The Center for Arts Education (CAE) is a nonprofit organization that is committed to stimulating and sustaining quality arts education as an essential part of every child’s education in the New York City public schools. Since 1996, CAE has… …   Wikipedia

  • The Guide for the Perplexed — This article is about the 12th century book by Maimonides. For the 1977 book by E.F. Schumacher, see A Guide for the Perplexed. For the 2001 novel by Gilad Atzmon, see A Guide to the Perplexed. The title page of The Guide for the Perplexed The… …   Wikipedia

  • The Singularity Is Near — The Singularity Is Near: When Humans Transcend Biology   …   Wikipedia

  • The Theory of Moral Sentiments — was written by Adam Smith in 1759. It provided the ethical, philosophical, psychological and methodological underpinnings to Smith s later works, including The Wealth of Nations (1776), A Treatise on Public Opulence (1764) (first published in… …   Wikipedia

  • The Shock Doctrine — The Shock Doctrine: The Rise of Disaster Capitalism   …   Wikipedia

  • The Humble Guys — (THG) were a cracking group for the IBM PC during the late 1980s founded by two friends known by the pseudonyms Candyman and Fabulous Furlough. The group was also noticed in the demoscene for some of their cracktros.THG was the first group to… …   Wikipedia

  • The Apprentice (U.S. season 5) — Infobox Television The Apprentice season name = The Apprentice 5 first aired = February 27, 2006 last aired = June 5, 2006 filming started = September, 2005 filming completed = November, 2005 winner = Sean Yazbeck number candidates = 18 number… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»