Перевод: с русского на немецкий

с немецкого на русский

wiring+board

  • 1 длительный допустимый ток

    1. Strombelastbarkeit, f
    2. Dauerstrombelastbarkeit, f

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-немецкий словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • Wiring board — Монтажная панель; Монтажная плата …   Краткий толковый словарь по полиграфии

  • board — board1 W1S1 [bo:d US bo:rd] n ▬▬▬▬▬▬▬ 1¦(information)¦ 2¦(for putting things on)¦ 3¦(group of people)¦ 4¦(in names)¦ 5¦(in building)¦ 6 on board 7¦(meals)¦ 8 go by the board 9¦(in water sports)¦ 10 across the board …   Dictionary of contemporary English

  • Wiring pencil — A wiring pencil (often sold under the trade names of road runner and verowire) is a tool for making electrical connections.A small reel of copper wire coated with a special insulating varnish is mounted on the end of the tool. The wire runs down… …   Wikipedia

  • board — 1 noun 1 INFORMATION (C) a flat wide piece of wood, plastic etc that shows a particular type of information: I wrote the examples up on the board. | Can I put this notice on the board? | I ll check the departure board for train times. see also:… …   Longman dictionary of contemporary English

  • board —    A circuit card that can be altered with the addition or deletion of external wiring …   IT glossary of terms, acronyms and abbreviations

  • Printed circuit board — Part of a 1983 Sinclair ZX Spectrum computer board; a populated PCB, showing the conductive traces, vias (the through hole paths to the other surface), and some mounted electrical components A printed circuit board, or PCB, is used to… …   Wikipedia

  • Consumer mains wiring — Đomestic consumer mains wiring refers to the wiring in the house hold premises and low voltage installations. Even though arbitrary electric wiring demands detailed calculations for selection of conductor sizes, circuit breakers, voltage drops… …   Wikipedia

  • Distribution board — A fairly standard American circuit breaker panel manufactured by General Electric and using interchangeable circuit breakers A distribution board (or panelboard) is a component of an electricity supply system which divides an electrical power… …   Wikipedia

  • Electricity Supply Board — Infobox Company company name = Electricity Supply Board company company type = Statutory Corporation foundation = Dublin, Ireland (1927) location = Dublin, Ireland key people = Padraig McManus, CEO Lochlann Quinn Chairman num employees = 7000… …   Wikipedia

  • Turret board — Turret boards were an early attempt at making electronic circuits that were relatively rugged, producible, and serviceable in the days before printed circuit boards (PCBs). As this method was somewhat more expensive than conventional point to… …   Wikipedia

  • printed circuit board — noun a thin plate or card on which chips, wiring, and other electronic components are placed to create an assembly unit. Abbrev.: PCB Also, printed circuit. {from the original production method which employed etching a metallic coating on a thin… …  

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»