Перевод: со всех языков на французский

с французского на все языки

time+device

  • 1 time-saving

    (device, method) qui économise ou fait gagner du temps;
    it's a time-saving device cet appareil fait gagner du temps
    2 noun
    gain m de temps

    Un panorama unique de l'anglais et du français > time-saving

  • 2 аппарат с выдержкой времени

    1. interrupteur temporisé

     

    аппарат с выдержкой времени
    Коммутационный электрический аппарат, имеющий устройство, обеспечивающее специально предусмотренную выдержку времени от момента подачи команды на выполнение коммутационной операции до начала ее выполнения.
    [ ГОСТ 17703-72]

    EN

    time-delay switch
    TDS
    switch provided with a time-delay device which operates for a certain time (the delay time). It may be either manually actuated and/or remotely electrically initiated
    [IEC 60669-2-3, ed. 3.0 (2006-08)]


    time-delay switch
    TDS
    a switch provided with a time-delay device, which operates for a certain time (the delay time) and which is operated by hand and/or by remote control by means of pulses
    [IEV number 442-04-33]


    mechanical time-delay device
    device which, through a mechanical auxiliary, operates some time after the instant at which the conditions which cause it to operate are established
    NOTE - This definition is only applicable to the switching circuit.
    [IEC 60669-2-3, ed. 3.0 (2006-08)]

    FR

    interrupteurs temporisés (minuteries)
    interrupteur pourvu d’un dispositif de temporisation qui le fait fonctionner pendant un certain temps (la temporisation). Il peut être commandé manuellement et/ou lancé électriquement à distance
    [IEC 60669-2-3, ed. 3.0 (2006-08)]


    interrupteur temporisé
    interrupteur pourvu d'un dispositif de temporisation qui le fait fonctionner pendant un certain temps (la temporisation) et qui est commandé manuellement et/ou à distance au moyen d'impulsions
    [IEV number 442-04-33]


    dispositif mécanique à action différée
    dispositif qui, par l'effet d'un auxiliaire mécanique, fonctionne un certain temps après l'instant où les conditions prévues pour son fonctionnement sont réalisées
    NOTE - Cette définition s’applique seulement au circuit de l’interrupteur.
    [IEC 60669-2-3, ed. 3.0 (2006-08)]

    Тематики

    • аппарат, изделие, устройство...

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > аппарат с выдержкой времени

  • 3 электрическое реле времени

    1. relais temporisé
    2. relais à temps spécifié

     

    электрическое реле времени
    Логическое электрическое реле с нормируемой выдержкой времени
    [ ГОСТ 16022-83]

    EN

    time relay
    specified-time relay (deprecated)
    all-or-nothing relay with one or more specified time functions
    [IEV number 445-01-01]

    FR

    relais à temps spécifié, m
    relais de tout ou rien comportant une ou plusieurs fonctions temporelles spécifiées
    [IEV number 445-01-01]


    Рис. Schneider Electric

    Параллельные тексты EN-RU

    A timing relay is a component which is designed to time events in industrial automation systems by closing or opening contacts before, during or after a set timing period.
    [Schneider Electric]

    Реле времени - это устройства, предназначенные для применения в схемах промышленной автоматизации и в соответствии со своей функцией, реализующие заданные выдержки времени, и замыкающие или размыкающие контакты реле до, в процессе или после отсчета выдержки времени.
    [Перевод Интент]


    Недопустимые, нерекомендуемые

    Тематики

    Синонимы

    EN

    DE

    FR

    6. Электрическое реле времени

    D. Zeitrelais

    E. Time relay

    F. Relais temporisé

    Логическое электрическое реле с нормируемой выдержкой времени

    Источник: ГОСТ 16022-83: Реле электрические. Термины и определения оригинал документа

    Русско-французский словарь нормативно-технической терминологии > электрическое реле времени

  • 4 устройство дифференциального тока с преднамеренной выдержкой времени

    1. dispositif différentiel à possibilité de retard

     

    устройство дифференциального тока с преднамеренной выдержкой времени
    -
    [IEV number 442-05-11]

    EN

    residual current device with intentional time-delay
    residual current device specially designed in order to permit the association with a particular device, so that such an association operates as a time-delay residual current device
    [IEV number 442-05-11]

    FR

    dispositif différentiel à possibilité de retard
    dispositif de coupure différentiel qui, grâce à des dispositions spéciales de construction, peut être combiné avec un dispositif particulier, de façon que cette combinaison constitue un dispositif de coupure différentiel temporisé
    [IEV number 442-05-11]

    Тематики

    Обобщающие термины

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > устройство дифференциального тока с преднамеренной выдержкой времени

  • 5 устройство выдержки времени

    1. dispositif de temporisation

     

    устройство выдержки времени
    -
    [IEV number 442-04-34]

    EN

    delay device
    device consisting of all components which have an influence on the delay time
    NOTE 1 – The delay device is energized by means of a pulse into the control circuit in an electrically controlled time-delay switch.
    NOTE 2 – The delay time can be adjustable.
    [IEV number 442-04-34]

    FR

    dispositif de temporisation
    dispositif composé de l'ensemble des constituants qui influencent la temporisation
    NOTE 1 – Dans les interrupteurs temporisés à commande électrique, le dispositif de temporisation est excité par une impulsion du circuit de commande.
    NOTE 2 – La temporisation peut être réglable.
    [IEV number 442-04-34]

    Тематики

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > устройство выдержки времени

  • 6 собственное время отключения

    1. durée d'ouverture (d'un appareil mécanique de connexion)

     

    собственное время отключения
    Собственным временем отключения называется интервал времени от момента подачи команды на отключение до момента прекращения соприкосновения (размыкания) дугогасительных контактов (для выключателей с шунтирующими резисторами следует различать время до момента прекращения соприкос-
    новения основных дугогасительных контактов и то же – для дугогасительных контактов шунтирующей цепи).
    Нормированное собственное время отключения выключателя принимается равным измеренному при отсутствии токовой нагрузки в главной цепи выключателя и при номинальном напряжении питания цепи управления.
    Собственное время отключения заключает в себе время оперирования любого вспомогательного оборудования, необходимого для отключения выключателя и являющегося его неотъемлемой частью.
    [IX Симпозиум «ЭЛЕКТРОТЕХНИКА 2030», доклад 4.53. 29 – 31 мая 2007 года]

    собственное время отключения
    to.c
    Интервал времени от момента подачи команды на отключение до момента прекращения соприкосновения (размыкания) дугогасительных контактов (для выключателей с шунтирующими резисторами следует различать время до момента прекращения соприкосновения основных дугогасительных контактов и то же - для дугогасительных контактов шунтирующей цепи).
    Собственное время отключения выключателя определяется в соответствии со способом отключения, как установлено ниже, и с любым устройством выдержки времени, являющимся неотъемлемой частью выключателя, установленным на свою минимальную регулировку:
    а) для выключателей, отключающих с помощью любой формы вспомогательной энергии, собственное время отключения представляет интервал времени между моментом подачи команды на катушку отключения или расцепитель выключателя, находящегося во включенном положении, и моментом, когда дугогасительные контакты разомкнутся во всех полюсах;
    б) для самоотключающегося выключателя собственное время отключения представляет интервал времени между моментом, при котором ток в главной цепи выключателя, находящегося во включенном положении, достигает значения срабатывания расцепителя максимального тока, и моментом, когда дугогасительные контакты разомкнутся во всех полюсах.
    Нормированное собственное время отключения выключателя принимается равным измеренному при отсутствии токовой нагрузки в главной цепи выключателя и при номинальном напряжении питания цепи управления.
    Для воздушных выключателей и для выключателей других видов с пневматическими приводами это время принимается равным измеренному при номинальном давлении воздуха.
    Примечания
    1 Собственное время отключения может изменяться в зависимости от значения отключаемого тока.
    2 Для многоразрывных выключателей момент, когда дугогасительные контакты разомкнутся во всех полюсах, определяется как момент размыкания контактов первого (по времени) разрыва полюса, размыкающегося последним.
    3 Собственное время отключения содержит в себе время оперирования любого вспомогательного оборудования, необходимого для отключения выключателя и являющегося его неотъемлемой частью.
    [ ГОСТ Р 52565-2006]

    EN

    opening time (of a mechanical switching device)
    the interval of time between the specified instant of initiation of the opening operation and the instant when the arcing contacts have separated in all poles
    NOTE – The instant of initiation of the opening operation, i.e. the application of the opening command (e.g. energizing the release, etc.) is given in the relevant specifications.
    [IEV number 441-17-36]

    FR

    durée d'ouverture (d'un appareil mécanique de connexion)
    intervalle de temps entre l'instant spécifié de début de la manoeuvre d'ouverture et l'instant de la séparation des contacts d'arc sur tous les pôles
    NOTE – L'instant de début de la manoeuvre d'ouverture, c'est-à-dire l'émission de l'ordre d'ouverture (par exemple l'alimentation d'un déclencheur, etc.) est donné dans les spécifications particulières.
    [IEV number 441-17-36]

    См. также полное время отключения

    Коммутационный цикл

    0732_1

    Параллельные тексты EN-RU

    1

    Breaker closed - apply auxillary power to activate the release.

    Выключатель во включенном положении. Начинает прикладываться внешнее усилие, направленное на отключение.

    2

    Contact separation - start of arc.

    Наличие зазора между разомкнутыми контактами. Возникновение дуги.

    3

    Extinction of arc.

    Погасание дуги.

    4

    Breacer open - initiation of closing movement.

    Выключатель в отключенном положении. Инициирование включения.

    5

    Current starts to flow in the conducting path (preignition)

    Начало протекания тока (начало горения дуги в изоляционном промежутке между разомкнутыми контактами).

    6

    Contact touch.

    Соприкосновение контактов.

    -

    Opening time.

    Собственное время отключения.

    -

    Arcing time

    Время дуги.

    -

    Make time.

    Время включения.

    -

    Break time/Interrupting time

    Полное время отключения

    -

    Dead time.

    Бестоковая пауза.

    -

    Closing time.

    Собственное время включения.

    -

    Reclosing time.

    Цикл автоматического повторного включения.

     

    [Siemens]

    [Перевод Интент]

    Тематики

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > собственное время отключения

  • 7 автоматическое повторное включение

    1. refermeture automatique
    2. réenclenchement automatique

     

    автоматическое повторное включение
    АПВ

    Коммутационный цикл, при котором выключатель вслед за его отключением автоматически включается через установленный промежуток времени (О - tбт - В).
    [ ГОСТ Р 52565-2006]

    автоматическое повторное включение
    АПВ

    Автоматическое включение аварийно отключившегося элемента электрической сети
    [ОАО РАО "ЕЭС России" СТО 17330282.27.010.001-2008]

    (автоматическое) повторное включение
    АПВ


    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва]

    EN

    automatic reclosing
    automatic reclosing of a circuit-breaker associated with a faulted section of a network after an interval of time which permits that section to recover from a transient fault
    [IEC 61936-1, ed. 1.0 (2002-10)]
    [IEV 604-02-32]


    auto-reclosing
    the operating sequence of a mechanical switching device whereby, following its opening, it closes automatically after a predetermined time
    [IEC 62271-100, ed. 2.0 (2008-04)]
    auto-reclosing (of a mechanical switching device)
    the operating sequence of a mechanical switching device whereby, following its opening, it closes automatically after a predetermined time
    [IEV number 441-16-10]

    FR

    réenclenchement automatique
    refermeture du disjoncteur associé à une fraction de réseau affectée d'un défaut, par un dispositif automatique après un intervalle de temps permettant la disparition d'un défaut fugitif
    [IEC 61936-1, ed. 1.0 (2002-10)]
    [IEV 604-02-32]


    refermeture automatique
    séquence de manoeuvres par laquelle, à la suite d’une ouverture, un appareil mécanique de connexion est refermé automatiquement après un intervalle de temps prédéterminé
    [IEC 62271-100, ed. 2.0 (2008-04)]
    refermeture automatique (d'un appareil mécanique de connexion)
    séquence de manoeuvres par laquelle, à la suite d'une ouverture, un appareil mécanique de connexion est refermé automatiquement après un intervalle de temps prédéterminé
    [IEV number 441-16-10]

     
    Автоматическое повторное включение (АПВ), быстрое автоматическое обратное включение в работу высоковольтных линий электропередачи и электрооборудования высокого напряжения после их автоматического отключения; одно из наиболее эффективных средств противоаварийной автоматики. Повышает надёжность электроснабжения потребителей и восстанавливает нормальный режим работы электрической системы. Во многих случаях после быстрого отключения участка электрической системы, на котором возникло короткое замыкание в результате кратковременного нарушения изоляции или пробоя воздушного промежутка, при последующей подаче напряжения повторное короткое замыкание не возникает.   АПВ выполняется с помощью автоматических устройств, воздействующих на высоковольтные выключатели после их аварийного автоматического отключения от релейной защиты. Многие из этих автоматических устройств обеспечивают АПВ при самопроизвольном отключении выключателей, например при сильных сотрясениях почвы во время близких взрывов, землетрясениях и т. п. Эффективность АПВ тем выше, чем быстрее следует оно за аварийным отключением, т. е. чем меньше время перерыва питания потребителей. Это время зависит от длительности цикла АПВ. В электрических системах применяют однократное АПВ — с одним циклом, двукратное — при неуспешном первом цикле, и трёхкратное — с тремя последовательными циклами. Цикл АПВ — время от момента подачи сигнала на отключение до замыкания цепи главными контактами выключателя — состоит из времени отключения и включения выключателя и времени срабатывания устройства АПВ. Длительность бестоковой паузы, когда потребитель не получает электроэнергию, выбирается такой, чтобы успело произойти восстановление изоляции (деионизация среды) в месте короткого замыкания, привод выключателя после отключения был бы готов к повторному включению, а выключатель к моменту замыкания его главных контактов восстановил способность к отключению поврежденной цепи в случае неуспешного АПВ. Время деионизации зависит от среды, климатических условий и других факторов. Время восстановления отключающей способности выключателя определяется его конструкцией и количеством циклов АПВ., предшествовавших данному. Обычно длительность 1-го цикла не превышает 0,5—1,5 сек, 2-го — от 10 до 15 сек, 3-го — от 60 до 120 сек.

    Наиболее распространено однократное АПВ, обеспечивающее на воздушных линиях высокого напряжения (110 кв и выше) до 86 %, а на кабельных линиях (3—10 кв) — до 55 % успешных включений. Двукратное АПВ обеспечивает во втором цикле до 15 % успешных включений. Третий цикл увеличивает число успешных включений всего на 3—5 %. На линиях электропередачи высокого напряжения (от 110 до 500 кВ) применяется однофазовое АПВ; при этом выключатели должны иметь отдельные приводы на каждой фазе.

    Применение АПВ экономически выгодно, т. к. стоимость устройств АПВ и их эксплуатации несравнимо меньше ущерба из-за перерыва в подаче электроэнергии.
    [ БСЭ]

     

    НАЗНАЧЕНИЕ И ОБЛАСТЬ ПРИМЕНЕНИЯ АПВ

    Опыт эксплуатации сетей высокого напряжения показал, что если поврежденную линию электропередачи быстро отключить, т. е. снять с нее напряжение, то в большинстве случаев повреждение ликвидируется. При этом электрическая дуга, возникавшая в месте короткого замыкания (КЗ), не успевает вызвать существенных разрушений оборудования, препятствующих обратному включению линии под напряжение.
    Самоустраняющиеся повреждения принято называть неустойчивыми. Такие повреждения возникают в результате грозовых перекрытий изоляции, схлестывания проводов при ветре и сбрасывании гололеда, падения деревьев, задевания проводов движущимися механизмами.
    Данные о повреждаемости воздушных линий электропередачи (ВЛ) за многолетний период эксплуатации показывают, что доля неустойчивых повреждений весьма высока и составляет 50—90 %.
    При ликвидации аварии оперативный персонал производит обычно опробование линии путем включения ее под напряжение, так как отыскание места повреждения на линии электропередачи путем ее обхода требует длительного времени, а многие повреждения носят неустойчивый характер. Эту операцию называют повторным включением.
    Если КЗ самоустранилось, то линия, на которой произошло неустойчивое повреждение, при повторном включении остается в работе. Поэтому повторные включения при неустойчивых повреждениях принято называть успешными.
    На ВЛ успешность повторного включения сильно зависит от номинального напряжения линий. На линиях ПО кВ и выше успешность повторного включения значительно выше, чем на ВЛ 6—35 кВ. Высокий процент успешных повторных включений в сетях высокого и сверхвысокого напряжения объясняется быстродействием релейной защиты (как правило, не более 0,1-0,15 с), большим сечением проводов и расстояний между ними, высокой механической прочностью опор. [Овчинников В. В., Автоматическое повторное включение. — М.:Энергоатомиздат, 1986.— 96 с: ил. — (Б-ка электромонтера; Вып. 587). Энергоатомиздат, 1986]

    АВТОМАТИЧЕСКОЕ ПОВТОРНОЕ ВКЛЮЧЕНИЕ (АПВ)

    3.3.2. Устройства АПВ должны предусматриваться для быстрого восстановления питания потребителей или межсистемных и внутрисистемных связей путем автоматического включения выключателей, отключенных устройствами релейной защиты.

    Должно предусматриваться автоматическое повторное включение:

    1) воздушных и смешанных (кабельно-воздушных) линий всех типов напряжением выше 1 кВ. Отказ от применения АПВ должен быть в каждом отдельном случае обоснован. На кабельных линиях 35 кВ и ниже АПВ рекомендуется применять в случаях, когда оно может быть эффективным в связи со значительной вероятностью повреждений с образованием открытой дуги (например, наличие нескольких промежуточных сборок, питание по одной линии нескольких подстанций), а также с целью исправления неселективного действия защиты. Вопрос о применении АПВ на кабельных линиях 110 кВ и выше должен решаться при проектировании в каждом отдельном случае с учетом конкретных условий;

    2) шин электростанций и подстанций (см. 3.3.24 и 3.3.25);

    3) трансформаторов (см. 3.3.26);

    4) ответственных электродвигателей, отключаемых для обеспечения самозапуска других электродвигателей (см. 3.3.38).

    Для осуществления АПВ по п. 1-3 должны также предусматриваться устройства АПВ на обходных, шиносоединительных и секционных выключателях.

    Допускается в целях экономии аппаратуры выполнение устройства группового АПВ на линиях, в первую очередь кабельных, и других присоединениях 6-10 кВ. При этом следует учитывать недостатки устройства группового АПВ, например возможность отказа в случае, если после отключения выключателя одного из присоединений отключение выключателя другого присоединения происходит до возврата устройства АПВ в исходное положение.

    3.3.3. Устройства АПВ должны быть выполнены так, чтобы они не действовали при:

    1) отключении выключателя персоналом дистанционно или при помощи телеуправления;

    2) автоматическом отключении от релейной защиты непосредственно после включения персоналом дистанционно или при помощи телеуправления;

    3) отключении выключателя защитой от внутренних повреждений трансформаторов и вращающихся машин, устройствами противоаварийной автоматики, а также в других случаях отключений выключателя, когда действие АПВ недопустимо. АПВ после действия АЧР (ЧАПВ) должно выполняться в соответствии с 3.3.81.

    Устройства АПВ должны быть выполнены так, чтобы была исключена возможностью многократного включения на КЗ при любой неисправности в схеме устройства.

    Устройства АПВ должны выполняться с автоматическим возвратом.

    3.3.4. При применении АПВ должно, как правило, предусматриваться ускорение действия релейной защиты на случай неуспешного АПВ. Ускорение действия релейной защиты после неуспешного АПВ выполняется с помощью устройства ускорения после включения выключателя, которое, как правило, должно использоваться и при включении выключателя по другим причинам (от ключа управления, телеуправления или устройства АВР). При ускорении защиты после включения выключателя должны быть приняты меры против возможного отключения выключателя защитой под действием толчка тока при включении из-за неодновременного включения фаз выключателя.

    Не следует ускорять защиты после включения выключателя, когда линия уже включена под напряжение другим своим выключателем (т. е. при наличии симметричного напряжения на линии).

    Допускается не ускорять после АПВ действие защит линий 35 кВ и ниже, выполненных на переменном оперативном токе, если для этого требуется значительное усложнение защит и время их действия при металлическом КЗ вблизи места установки не превосходит 1,5 с.

    3.3.5. Устройства трехфазного АПВ (ТАПВ) должны осуществляться преимущественно с пуском при несоответствии между ранее поданной оперативной командой и отключенным положением выключателя; допускается также пуск устройства АПВ от защиты.

    3.3.6. Могут применяться, как правило, устройства ТАПВ однократного или двукратного действия (последнее - если это допустимо по условиям работы выключателя). Устройство ТАПВ двукратного действия рекомендуется принимать для воздушных линий, в особенности для одиночных с односторонним питанием. В сетях 35 кВ и ниже устройства ТАПВ двукратного действия рекомендуется применять в первую очередь для линий, не имеющих резервирования по сети.

    В сетях с изолированной или компенсированной нейтралью, как правило, должна применяться блокировка второго цикла АПВ в случае замыкания на землю после АПВ первого цикла (например, по наличию напряжений нулевой последовательности). Выдержка времени ТАПВ во втором цикле должна быть не менее 15-20 с.

    3.3.7. Для ускорения восстановления нормального режима работы электропередачи выдержка времени устройства ТАПВ (в особенности для первого цикла АПВ двукратного действия на линиях с односторонним питанием) должна приниматься минимально возможной с учетом времени погасания дуги и деионизации среды в месте повреждения, а также с учетом времени готовности выключателя и его привода к повторному включению.

    Выдержка времени устройства ТАПВ на линии с двусторонним питанием должна выбираться также с учетом возможного неодновременного отключения повреждения с обоих концов линии; при этом время действия защит, предназначенных для дальнего резервирования, учитываться не должно. Допускается не учитывать разновременности отключения выключателей по концам линии, когда они отключаются в результате срабатывания высокочастотной защиты.

    С целью повышения эффективности ТАПВ однократного действия допускается увеличивать его выдержку времени (по возможности с учетом работы потребителя).

    3.3.8. На одиночных линиях 110 кВ и выше с односторонним питанием, для которых допустим в случае неуспешного ТАПВ переход на длительную работу двумя фазами, следует предусматривать ТАПВ двукратного действия на питающем конце линии. Перевод линии на работу двумя фазами может производиться персоналом на месте или при помощи телеуправления.

    Для перевода линии после неуспешного АПВ на работу двумя фазами следует предусматривать пофазное управление разъединителями или выключателями на питающем и приемном концах линии.

    При переводе линии на длительную работу двумя фазами следует при необходимости принимать меры к уменьшению помех в работе линий связи из-за неполнофазного режима работы линии. С этой целью допускается ограничение мощности, передаваемой по линии в неполнофазном режиме (если это возможно по условиям работы потребителя).

    В отдельных случаях при наличии специального обоснования допускается также перерыв в работе линии связи на время неполнофазного режима.

    3.3.9. На линиях, отключение которых не приводит к нарушению электрической связи между генерирующими источниками, например на параллельных линиях с односторонним питанием, следует устанавливать устройства ТАПВ без проверки синхронизма.

    3.3.10. На одиночных линиях с двусторонним питанием (при отсутствии шунтирующих связей) должен предусматриваться один из следующих видов трехфазного АПВ (или их комбинаций):

    а) быстродействующее ТАПВ (БАПВ)

    б) несинхронное ТАПВ (НАПВ);

    в) ТАПВ с улавливанием синхронизма (ТАПВ УС).

    Кроме того, может предусматриваться однофазное АПВ (ОАПВ) в сочетании с различными видами ТАПВ, если выключатели оборудованы пофазным управлением и не нарушается устойчивость параллельной работы частей энергосистемы в цикле ОАПВ.

    Выбор видов АПВ производится, исходя из совокупности конкретных условий работы системы и оборудования с учетом указаний 3.3.11-3.3.15.

    3.3.11. Быстродействующее АПВ, или БАПВ (одновременное включение с минимальной выдержкой времени с обоих концов), рекомендуется предусматривать на линиях по 3.3.10 для автоматического повторного включения, как правило, при небольшом расхождении угла между векторами ЭДС соединяемых систем. БАПВ может применяться при наличии выключателей, допускающих БАПВ, если после включения обеспечивается сохранение синхронной параллельной работы систем и максимальный электромагнитный момент синхронных генераторов и компенсаторов меньше (с учетом необходимого запаса) электромагнитного момента, возникающего при трехфазном КЗ на выводах машины.

    Оценка максимального электромагнитного момента должна производиться для предельно возможного расхождения угла за время БАПВ. Соответственно запуск БАПВ должен производиться лишь при срабатывании быстродействующей защиты, зона действия которой охватывает всю линию. БАПВ должно блокироваться при срабатывании резервных защит и блокироваться или задерживаться при работе УРОВ.

    Если для сохранения устойчивости энергосистемы при неуспешном БАПВ требуется большой объем воздействий от противоаварийной автоматики, применение БАПВ не рекомендуется.

    3.3.12. Несинхронное АПВ (НАПВ) может применяться на линиях по 3.3.10 (в основном 110-220 кВ), если:

    а) максимальный электромагнитный момент синхронных генераторов и компенсаторов, возникающий при несинхронном включении, меньше (с учетом необходимого запаса) электромагнитного момента, возникающего при трехфазном КЗ на выводах машины, при этом в качестве практических критериев оценки допустимости НАПВ принимаются расчетные начальные значения периодических составляющих токов статора при угле включения 180°;

    б) максимальный ток через трансформатор (автотрансформатор) при угле включения 180° меньше тока КЗ на его выводах при питании от шин бесконечной мощности;

    в) после АПВ обеспечивается достаточно быстрая ресинхронизация; если в результате несинхронного автоматического повторного включения возможно возникновение длительного асинхронного хода, должны применяться специальные мероприятия для его предотвращения или прекращения.

    При соблюдении этих условий НАПВ допускается применять также в режиме ремонта на параллельных линиях.

    При выполнении НАПВ необходимо принять меры по предотвращению излишнего срабатывания защиты. С этой целью рекомендуется, в частности, осуществлять включение выключателей при НАПВ в определенной последовательности, например выполнением АПВ с одной из сторон линии с контролем наличия напряжения на ней после успешного ТАПВ с противоположной стороны.

    3.3.13. АПВ с улавливанием синхронизма может применяться на линиях по 3.3.10 для включения линии при значительных (примерно до 4%) скольжениях и допустимом угле.

    Возможно также следующее выполнение АПВ. На конце линии, который должен включаться первым, производится ускоренное ТАПВ (с фиксацией срабатывания быстродействующей защиты, зона действия которой охватывает всю линию) без контроля напряжения на линии (УТАПВ БК) или ТАПВ с контролем отсутствия напряжения на линии (ТАПВ ОН), а на другом ее конце - ТАПВ с улавливанием синхронизма. Последнее производится при условии, что включение первого конца было успешным (это может быть определено, например, при помощи контроля наличия напряжения на линии).

    Для улавливания синхронизма могут применяться устройства, построенные по принципу синхронизатора с постоянным углом опережения.

    Устройства АПВ следует выполнять так, чтобы имелась возможность изменять очередность включения выключателей по концам линии.

    При выполнении устройства АПВ УС необходимо стремиться к обеспечению его действия при возможно большей разности частот. Максимальный допустимый угол включения при применении АПВ УС должен приниматься с учетом условий, указанных в 3.3.12. При применении устройства АПВ УС рекомендуется его использование для включения линии персоналом (полуавтоматическая синхронизация).

    3.3.14. На линиях, оборудованных трансформаторами напряжения, для контроля отсутствия напряжения (КОН) и контроля наличия напряжения (КНН) на линии при различных видах ТАПВ рекомендуется использовать органы, реагирующие на линейное (фазное) напряжение и на напряжения обратной и нулевой последовательностей. В некоторых случаях, например на линиях без шунтирующих реакторов, можно не использовать напряжение нулевой последовательности.

    3.3.15. Однофазное автоматическое повторное включение (ОАПВ) может применяться только в сетях с большим током замыкания на землю. ОАПВ без автоматического перевода линии на длительный неполнофазный режим при устойчивом повреждении фазы следует применять:

    а) на одиночных сильно нагруженных межсистемных или внутрисистемных линиях электропередачи;

    б) на сильно нагруженных межсистемных линиях 220 кВ и выше с двумя и более обходными связями при условии, что отключение одной из них может привести к нарушению динамической устойчивости энергосистемы;

    в) на межсистемных и внутрисистемных линиях разных классов напряжения, если трехфазное отключение линии высшего напряжения может привести к недопустимой перегрузке линий низшего напряжения с возможностью нарушения устойчивости энергосистемы;

    г) на линиях, связывающих с системой крупные блочные электростанции без значительной местной нагрузки;

    д) на линиях электропередачи, где осуществление ТАПВ сопряжено со значительным сбросом нагрузки вследствие понижения напряжения.

    Устройство ОАПВ должно выполняться так, чтобы при выводе его из работы или исчезновении питания автоматически осуществлялся перевод действия защит линии на отключение трех фаз помимо устройства.

    Выбор поврежденных фаз при КЗ на землю должен осуществляться при помощи избирательных органов, которые могут быть также использованы в качестве дополнительной быстродействующей защиты линии в цикле ОАПВ, при ТАПВ, БАПВ и одностороннем включении линии оперативным персоналом.

    Выдержка временем ОАПВ должна отстраиваться от времени погасания дуги и деионизации среды в месте однофазного КЗ в неполнофазном режиме с учетом возможности неодновременного срабатывания защиты по концам линии, а также каскадного действия избирательных органов.

    3.3.16. На линиях по 3.3.15 ОАПВ должно применяться в сочетании с различными видами ТАПВ. При этом должна быть предусмотрена возможность запрета ТАПВ во всех случаях ОАПВ или только при неуспешном ОАПВ. В зависимости от конкретных условий допускается осуществление ТАПВ после неуспешного ОАПВ. В этих случаях предусматривается действие ТАПВ сначала на одном конце линии с контролем отсутствия напряжения на линии и с увеличенной выдержкой времени.

    3.3.17. На одиночных линиях с двусторонним питанием, связывающих систему с электростанцией небольшой мощности, могут применяться ТАПВ с автоматической самосинхронизацией (АПВС) гидрогенераторов для гидроэлектростанций и ТАПВ в сочетании с делительными устройствами - для гидро- и теплоэлектростанций.

    3.3.18. На линиях с двусторонним питанием при наличии нескольких обходных связей следует применять:

    1) при наличии двух связей, а также при наличии трех связей, если вероятно одновременное длительное отключение двух из этих связей (например, двухцепной линии):

    несинхронное АПВ (в основном для линий 110-220 кВ и при соблюдении условий, указанных в 3.3.12, но для случая отключения всех связей);

    АПВ с проверкой синхронизма (при невозможности выполнения несинхронного АПВ по причинам, указанным в 3.3.12, но для случая отключения всех связей).

    Для ответственных линий при наличии двух связей, а также при наличии трех связей, две из которых - двухцепная линия, при невозможности применения НАПВ по причинам, указанным в 3.3.12, разрешается применять устройства ОАПВ, БАПВ или АПВ УС (см. 3.3.11, 3.3.13, 3.3.15). При этом устройства ОАПВ и БАПВ следует дополнять устройством АПВ с проверкой синхронизма;

    2) при наличии четырех и более связей, а также при наличии трех связей, если в последнем случае одновременное длительное отключение двух из этих связей маловероятно (например, если все линии одноцепные), - АПВ без проверки синхронизма.

    3.3.19. Устройства АПВ с проверкой синхронизма следует выполнять на одном конце линии с контролем отсутствия напряжения на линии и с контролем наличия синхронизма, на другом конце - только с контролем наличия синхронизма. Схемы устройства АПВ с проверкой синхронизма линии должны выполняться одинаковыми на обоих концах с учетом возможности изменения очередности включения выключателей линии при АПВ.

    Рекомендуется использовать устройство АПВ с проверкой синхронизма для проверки синхронизма соединяемых систем при включении линии персоналом.

    3.3.20. Допускается совместное применение нескольких видов трехфазного АПВ на линии, например БАПВ и ТАПВ с проверкой синхронизма. Допускается также использовать различные виды устройств АПВ на разных концах линии, например УТАПВ БК (см. 3.3.13) на одном конце линии и ТАПВ с контролем наличия напряжения и синхронизма на другом.

    3.3.21. Допускается сочетание ТАПВ с неселективными быстродействующими защитами для исправления неселективного действия последних. В сетях, состоящих из ряда последовательно включенных линий, при применении для них неселективных быстродействующих защит для исправления их действия рекомендуется применять поочередное АПВ; могут также применяться устройства АПВ с ускорением защиты до АПВ или с кратностью действия (не более трех), возрастающей по направлению к источнику питания.

    3.3.22. При применении трехфазного однократного АПВ линий, питающих трансформаторы, со стороны высшего напряжения которых устанавливаются короткозамыкатели и отделители, для отключения отделителя в бестоковую паузу время действия устройства АПВ должно быть отстроено от суммарного времени включения короткозамыкателя и отключения отделителя. При применении трехфазного АПВ двукратного действия (см. 3.3.6) время действия АПВ в первом цикле по указанному условию не должно увеличиваться, если отключение отделителя предусматривается в бестоковую паузу второго цикла АПВ.

    Для линий, на которые вместо выключателей устанавливаются отделители, отключение отделителей в случае неуспешного АПВ в первом цикле должно производиться в бестоковую паузу второго цикла АПВ.

    3.3.23. Если в результате действия АПВ возможно несинхронное включение синхронных компенсаторов или синхронных электродвигателей и если такое включение для них недопустимо, а также для исключения подпитки от этих машин места повреждения следует предусматривать автоматическое отключение этих синхронных машин при исчезновении питания или переводить их в асинхронный режим отключением АГП с последующим автоматическим включением или ресинхронизацией после восстановления напряжения в результате успешного АПВ.

    Для подстанций с синхронными компенсаторами или синхронными электродвигателями должны применяться меры, предотвращающие излишние срабатывания АЧР при действии АПВ.

    3.3.24. АПВ шин электростанций и подстанций при наличии специальной защиты шин и выключателей, допускающих АПВ, должно выполняться по одному из двух вариантов:

    1) автоматическим опробованием (постановка шин под напряжение выключателем от АПВ одного из питающих элементов);

    2) автоматической сборкой схемы; при этом первым от устройства АПВ включается один из питающих элементов (например, линия, трансформатор), при успешном включении этого элемента производится последующее, возможно более полное автоматическое восстановление схемы доаварийного режима путем включения других элементов. АПВ шин по этому варианту рекомендуется применять в первую очередь для подстанций без постоянного дежурства персонала.

    При выполнении АПВ шин должны применяться меры, исключающие несинхронное включение (если оно является недопустимым).

    Должна обеспечиваться достаточная чувствительность защиты шин на случай неуспешного АПВ.

    3.3.25. На двухтрансформаторных понижающих подстанциях при раздельной работе трансформаторов, как правило, должны предусматриваться устройства АПВ шин среднего и низшего напряжений в сочетании с устройствами АВР; при внутренних повреждениях трансформаторов должно действовать АВР, при прочих повреждениях - АПВ (см. 3.3.42).

    Допускается для двухтрансформаторной подстанции, в нормальном режиме которой предусматривается параллельная работа трансформаторов на шинах данного напряжения, устанавливать дополнительно к устройству АПВ устройство АВР, предназначенное для режима, когда один из трансформаторов выведен в резерв.

    3.3.26. Устройствами АПВ должны быть оборудованы все одиночные понижающие трансформаторы мощностью более 1 MB·А на подстанциях энергосистем, имеющие выключатель и максимальную токовую защиту с питающей стороны, когда отключение трансформатора приводит к обесточению электроустановок потребителей. Допускается в отдельных случаях действие АПВ и при отключении трансформатора защитой от внутренних повреждений.

    3.3.27. При неуспешном АПВ включаемого первым выключателем элемента, присоединенного двумя или более выключателями, АПВ остальных выключателей этого элемента, как правило, должно запрещаться.

    3.3.28. При наличии на подстанции или электростанции выключателей с электромагнитным приводом, если от устройства АПВ могут быть одновременно включены два или более выключателей, для обеспечения необходимого уровня напряжения аккумуляторной батареи при включении и для снижения сечения кабелей цепей питания электромагнитов включения следует, как правило, выполнять АПВ так, чтобы одновременное включение нескольких выключателей было исключено (например, применением на присоединениях АПВ с различными выдержками времени).

    Допускается в отдельных случаях (преимущественно при напряжении 110 кВ и большом числе присоединений, оборудованных АПВ) одновременное включение от АПВ двух выключателей.

    3.3.29. Действие устройств АПВ должно фиксироваться указательными реле, встроенными в реле указателями срабатывания, счетчиками числа срабатываний или другими устройствами аналогичного назначения.
    [ ПУЭ]

    Тематики

    Обобщающие термины

    Синонимы

    Сопутствующие термины

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > автоматическое повторное включение

  • 8 устройство дифференциального тока с выдержкой времени

    1. dispositif différentiel temporisé

     

    устройство дифференциального тока с выдержкой времени
    -
    [IEV number 442-05-05]

    EN

    time-delay residual current device
    residual current device specially designed to attain a predetermined value of limiting non-actuating time, corresponding to a given value of residual current
    [IEV number 442-05-05]

    FR

    dispositif différentiel temporisé
    dispositif de coupure différentiel spécialement conçu pour obtenir une valeur prédéterminée du temps limite de non-réponse correspondant à une valeur donnée du courant différentiel
    [IEV number 442-05-05]

    Тематики

    Обобщающие термины

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > устройство дифференциального тока с выдержкой времени

  • 9 автоматический выключатель

    1. interrupteur automatique
    2. disjoncteur
    3. coupe-circuit
    4. conjoncteur-disjoncteur

     

    автоматический выключатель
    Механический коммутационный аппарат
    1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
    (МЭС 441-14-20)
    [ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]

    автоматический выключатель
    -
    [IEV number 442-05-01]

    EN

    circuit breaker
    a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

    circuit breaker

    A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
    NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
    Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
    Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
    Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
    Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
    [National Electrical Cod]

    FR

    disjoncteur
    appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
    [IEC 62271-100, ed. 2.0 (2008-04)]
    [IEV number 442-05-01]

      1)  Должно быть контактный коммутационный аппарат
    [Интент] 
    КЛАССИФИКАЦИЯ

      0067 Автоматические выключатели ABB   0068 Модульные автоматические выключатели
    1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
    Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
    Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).

    [Интент]
    Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
    [
    Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Электромагнитный расцепитель;
    5 - Сердечник
    6 - Катушка
    7 - Контактные зажимы автоматического выключателя

    Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
    На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
    Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).

    Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем. 

     

    1 - Пружина (в данном случае во взведенном положении растянута)
    2 - Главный контакт автоматического выключателя
    3 - Удерживающее устройство
    4 - Тепловой расцепитель
    5 - Биметаллическая пластина
    6 - Нагревательный элемент
    7 - Контактные зажимы автоматического выключателя

    Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
    [Интент]

    Недопустимые, нерекомендуемые

    Тематики

    Классификация

    >>>

    Обобщающие термины

    Действия

    EN

    DE

    FR

    Смотри также

    Русско-французский словарь нормативно-технической терминологии > автоматический выключатель

  • 10 орган управления

    1. organe de manoeuvre
    2. organe de commande

     

    орган управления
    Часть системы аппарата управления, к которой прилагается извне усилие управления.
    МЭК 60050(441-15-22).
    Примечание. Орган управления может иметь форму рукоятки, ручки, нажимной кнопки, ролика, плунжера и т. п.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    орган управления

    Часть приводного механизма, к которой прикладывается внешняя сила воздействия.
    Примечание - Орган управления может иметь форму ручки, кнопки, ролика, поршня и т.д.
    [ ГОСТ Р 52726-2007]

    орган управления
    Часть системы привода, подвергаемая внешнему силовому воздействию.
    Примечания
    1. Орган управления может иметь форму ручки, рукоятки, нажимной кнопки, ролика, плунжера и т.д.
    2. Есть несколько способов приведения в действие, которые не требуют внешнего силового воздействия, а только какого-либо действия.
    [ГОСТ ЕН 1070-2003]

    орган управления
    Часть системы управления, которая предназначена непосредственно для воздействия оператором, например путем нажатия.
    [ГОСТ Р ЕН 614-1-2003]

    орган управления

    Часть системы приведения в действие, которая принимает воздействие человека.
    [ ГОСТ Р МЭК 60447-2000]

    орган управления
    Часть системы приведения в действие, которая воспринимает воздействие человека (ГОСТ Р МЭК 60447).
    Примечание
    В настоящем стандарте орган управления в виде интерактивного экранного устройства отображения является частью этого устройства, которое представляет функцию органа управления.
    [ ГОСТ Р МЭК 60073-2000]

    орган управления
    Часть механизма прибора управления, на который оказывается вручную внешнее силовое воздействие.
    Примечание.
    Орган управления может иметь форму ручки, рукоятки, кнопки, ролика, плунжера и т.д.
    Некоторые органы управления не требуют воздействия внешней силы, а только какого-либо действия.
    [ ГОСТ Р МЭК 60204-1-2007]

    органы управления
    Ручки, переключатели, потенциометры и другие органы, служащие для включения и регулировки аппаратуры. Термин относится преимущественно к аналоговым приборам.
    [Система неразрушающего контроля. Виды (методы) и технология неразрушающего контроля. Термины и определения (справочное пособие). Москва 2003 г.]

    орган управления
    -
    [IEV number 442-04-14]

    средства оперирования
    -

    [Интент]

    EN

    actuator
    the part of the actuating system to which an external actuating force is applied
    NOTE – The actuator may take the form of a handle, knob, push-button, roller, plunger, etc.
    [IEV number 441-15-22]

    actuator
    part of a device to which an external manual action is to be applied
    NOTE 1 The actuator may take the form of a handle, knob, push-button, roller, plunger, etc.
    NOTE 2 There are some actuating means that do not require an external actuating force, but only an action.
    NOTE 3 See also 3.34.
    [IEC 60204-1 -2005]

    actuating member
    a part which is pulled, pushed, turned or otherwise moved to cause an operation of the switch
    [IEV number 442-04-14]

    FR

    organe de commande
    partie du mécanisme transmetteur à laquelle un effort extérieur de manoeuvre est appliqué
    NOTE – L'organe de commande peut prendre la forme d'une poignée, d'un bouton, d'un bouton-poussoir, d'une roulette, d'un plongeur, etc.
    [IEV number 441-15-22]

    organe de manoeuvre
    partie qui est tirée, poussée, tournée ou manipulée de toute autre façon pour provoquer le fonctionnement de l'interrupteur
    [IEV number 442-04-14]


    Аппарат должен оставаться механически действующим. Не допускается сваривание контактов, препятствующее операции размыкания при использовании нормальных средств оперирования.
    [ГОСТ  Р 50030.3-99 (МЭК  60947-3-99) ]

    ВДТ следует оперировать как при нормальной эксплуатации. Операции размыкания должны проводиться в следующем порядке:
    для первых 1000 циклов — с использованием ручных средств оперирования;
    ...
    [ ГОСТ Р 51326. 1-99 ( МЭК 61008-1-96)]

    Параллельные тексты EN-RU

    The operating means (for example, a handle) of the supply disconnecting device shall be easily accessible and located between 0,6 m and 1,9 m above the servicing level.
    [IEC 60204-1-2006]

    Органы управления, например, рукоятки аппаратов отключения питания, должны быть легко доступны и располагаться на высоте от 0,6 до 1,9 м от рабочей площадки.
    [Перевод Интент]

    Where the external operating means is not intended for emergency operations, it is recommended that it be coloured BLACK or GREY.
    [IEC 60204-1-2006]

    Если внешние средства оперирования не предназначены для выполнения действий при возникновении аварийных ситуаций, то рекомендуется, применять такие средства ЧЕРНОГО или СЕРОГО цвета.
    [Перевод Интент]

     

    1.2.2. Control devices

    Control devices must be:
    — clearly visible and identifiable and appropriately marked where necessary,
    — positioned for safe operation without hesitation or loss of time, and without ambiguity,
    — designed so that the movement of the control is consistent with its effect,
    — located outside the danger zones, except for certain controls where necessary, such as emergency stop, console for training of robots,
    — positioned so that their operation cannot cause additional risk,
    — designed or protected so that the desired effect, where a risk is involved, cannot occur without an intentional operation,
    — made so as to withstand foreseeable strain; particular attention must be paid to emergency stop devices liable to be subjected to considerable strain.

    1.2.2. Органы управления

    Органы управления должны быть:
    - четко видны, хорошо различимы и, где это необходимо, иметь соответствующее обозначение;
    - расположены так, чтобы ими можно было пользоваться без возникновения сомнений и потерь времени на выяснение их назначения;
    - сконструированы так, чтобы перемещение органа управления согласовывалось с их воздействием;
    - расположены вне опасных зон; исключение, где это необходимо, делается для определенных средств управления, таких, как средство экстренной остановки, пульт управления роботом;
    - расположены так, чтобы их использование не вызывало дополнительных рисков;
    - сконструированы или защищены так, чтобы в случаях, где возможно возникновение рисков, они не могли бы возникнуть без выполнения намеренных действий;
    - сделаны так, чтобы выдерживать предполагаемую нагрузку; при этом особое внимание уделяется органам аварийного останова, которые могут подвергаться значительным нагрузкам.

    Where a control is designed and constructed to perform several different actions, namely where there is no one-to-one correspondence (e.g. keyboards, etc.), the action to be performed must be clearly displayed and subject to confirmation where necessary.

    Если орган управления предназначен для выполнения разных действий, например, если в качестве органа управления используется клавиатура или аналогичное устройство, то должна выводиться четкая информация о предстоящем действии, и, если необходимо, должно выполняться подтверждение на выполнение такого действия.

    Controls must be so arranged that their layout, travel and resistance to operation are compatible with the action to be performed, taking account of ergonomic principles.

    Органы управления должны быть организованы таким образом, чтобы их расположение, перемещение их элементов и усилие, которое оператор затрачивает на их перемещение, соответствовали выполняемым операциям и принципам эргономики.

    Constraints due to the necessary or foreseeable use of personal protection equipment (such as footwear, gloves, etc.) must be taken into account.

    Необходимо учитывать скованность движений операторов при использовании необходимых или предусмотренных средств индивидуальной защиты (таких, как специальная обувь, перчатки и др.).

    Machinery must be fitted with indicators (dials, signals, etc.) as required for safe operation. The operator must be able to read them from the control position.

    Для обеспечения безопасной эксплуатации машинное оборудование должно быть оснащено индикаторами (циферблатами, устройствами сигнализации и т. д.). Оператор должен иметь возможность считывать их с места управления.

    From the main control position the operator must be able to ensure that there are no exposed persons in the danger zones.

    Находясь в главном пункте управления, оператор должен иметь возможность контролировать отсутствие незащищенных лиц.

    If this is impossible, the control system must be designed and constructed so that an acoustic and/ or visual warning signal is given whenever the machinery is about to start.

    Если это невозможно, то система управления должна быть разработана и изготовлена так, чтобы перед каждым пуском машинного оборудования подавался звуковой и/или световой предупредительный сигнал.

    The exposed person must have the time and the means to take rapid action to prevent the machinery starting up.

    [DIRECTIVE 98/37/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL]

    Незащищенное лицо должно иметь достаточно времени и средств для быстрого предотвращения пуска машинного оборудования.

    [Перевод Интент]

    Тематики

    Синонимы

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > орган управления

  • 11 условный ток короткого замыкания (в цепи или коммутационном аппарате)

    1. courant de court-circuit conditionnel (d'un circuit ou d'un appareil de connexion)

     

    условный ток короткого замыкания (в цепи или коммутационном аппарате)
    Ожидаемый ток, который цепь или коммутационнный аппарат, защищенные установленным устройством от коротких замыканий, способны удовлетворительно выдерживать в течение всего времени срабатывания этого устройства в указанных условиях эксплуатации и поведения.
    Примечания
    1 В настоящем стандарте устройством для защиты от коротких замыканий служит, как правило, автоматический выключатель или плавкие предохранители.
    2 Это определение отличается от МЭК 60050(441-17-20) расширением понятия токоограничивающего аппарата до устройства для защиты от коротких замыканий, функция которого не сводится только к токоограничению.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    EN

    conditional short-circuit current (of a circuit or a switching device)
    the prospective current that a circuit or a switching device, protected by a specified current limiting device, can satisfactorily withstand for the operating time of that current limiting device under specified conditions of use and behaviour
    [IEV number 441-17-20]

    FR

    courant de court-circuit conditionnel (d'un circuit ou d'un appareil de connexion)
    courant présumé qu'un circuit ou un appareil de connexion, protégé par un dispositif limiteur de courant spécifié, peut supporter de façon satisfaisante pendant la durée de fonctionnement de cet appareil limiteur de courant dans des conditions spécifiées d'emploi et de comportement
    [IEV number 441-17-20]

    Тематики

    EN

    DE

    FR

    • courant de court-circuit conditionnel (d'un circuit ou d'un appareil de connexion)

    Русско-французский словарь нормативно-технической терминологии > условный ток короткого замыкания (в цепи или коммутационном аппарате)

  • 12 время дуги многополюсного аппарата

    1. durée d'arc (d'un appareil de connexion multipolaire)

     

    время дуги многополюсного аппарата
    Интервал времени между моментом появлении первой дуги и моментом окончательного погасания дуги во всех полюсах аппарата.
    [ ГОСТ 17703-72]
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    время горения дуги в многополюсном выключателе
    Интервал между моментом первого появления дуги и моментом окончательного гашения дуг во всех полюсах.
    [ ГОСТ Р 50345-99]

    время дуги

    Интервал времени между моментом первого возникновения дуги и моментом окончательного ее погасания во всех полюсах.
    [ ГОСТ Р 52565-2006]

    EN

    arcing time (of a multipole switching device)
    the interval of time between the instant of the first initiation of an arc and the instant of final arc extinction in all poles
    [IEV number 441-17-38]

    FR

    durée d'arc (d'un appareil de connexion multipolaire)
    intervalle de temps entre l'instant du premier début d'un arc et l'instant de l'extinction finale de l'arc sur tous les pôles
    [IEV number 441-17-38]

    Тематики

    • аппарат, изделие, устройство...
    • выключатель, переключатель
    • высоковольтный аппарат, оборудование...

    Синонимы

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > время дуги многополюсного аппарата

  • 13 время размыкания (контактного коммутационного аппарата)

    1. durée d'ouverture (d'un appareil mécanique de connexion)

     

    время размыкания (контактного коммутационного аппарата)
    Интервал времени между установленным начальным моментом размыкания и моментом разъединения дугогасительных контактов во всех полюсах.
    МЭК 60050 (441-17-36).
    Примечание.  Начальный момент размыкания (например подача сигнала к размыканию на расцепитель и т. п.), устанавливается в стандарте на соответствующий аппарат.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    EN

    opening time (of a mechanical switching device)
    the interval of time between the specified instant of initiation of the opening operation and the instant when the arcing contacts have separated in all poles
    NOTE – The instant of initiation of the opening operation, i.e. the application of the opening command (e.g. energizing the release, etc.) is given in the relevant specifications.
    [IEV number 441-17-36]

    FR

    durée d'ouverture (d'un appareil mécanique de connexion)
    intervalle de temps entre l'instant spécifié de début de la manoeuvre d'ouverture et l'instant de la séparation des contacts d'arc sur tous les pôles
    NOTE – L'instant de début de la manoeuvre d'ouverture, c'est-à-dire l'émission de l'ordre d'ouverture (par exemple l'alimentation d'un déclencheur, etc.) est donné dans les spécifications particulières.
    [IEV number 441-17-36]

     

    Тематики

    • аппарат, изделие, устройство...

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > время размыкания (контактного коммутационного аппарата)

  • 14 реле переключения со звезды на треугольник

    1. relais temporisé à couplage étoile-triangle, m

     

    реле переключения со звезды на треугольник
    -
    [Интент]

    EN

    star-delta relay
    time relay including two delayed outputs switching one after the other, for starting of motors in the star mode and subsequent change to the delta mode (see Figure 6)
    4796
    NOTE – The star and delta connections are defined in IEV 141-02-06 and IEV 141-02-09 respectively.
    [IEV ref 445-01-09]

    FR

    relais temporisé à couplage étoile-triangle, m
    relais temporisé comportant deux sorties temporisées commutant l'une après l'autre conçu pour assurer le démarrage de moteurs dans un couplage en étoile, puis le passage dans un couplage en triangle (voir Figure 6)
    4796
    NOTE – Les couplages en étoile et en triangle sont définis en IEV 141-02-06 et IEV 141-02-09 respectivement.
    [IEV ref 445-01-09]

    Параллельные тексты EN-RU
    4699

    Star-delta relay

    When energy applied to device, star relay is energized until the end of the adjustable tλ, time.

    At the end of the adjusted delay time tλ-Δ, delta relay is energized until the device is powered off.

    [Klemsan]

    Реле переключения со звезды на треугольник

    При подаче напряжения на реле переключения со звезды на треугольник включается реле включения по схеме "звезда" и остается включенным до окончания заданной задержки tλ.


    По окончании задержки времени tλ-Δ включается реле включения по схеме "треугольник" и остается включенным до прекращения подачи напряжения на реле переключения со звезды на треугольник.

    [Перевод Интент]

       

    Тематики

    EN

    DE

    • Stern-Dreieck-Relais, n

    FR

    • relais temporisé à couplage étoile-triangle, m

    Русско-французский словарь нормативно-технической терминологии > реле переключения со звезды на треугольник

  • 15 аппарат защиты от сверхтока

    1. dispositif de protection contre les surintensités

     

    аппарат защиты от сверхтока
    -

    EN

    overcurrent protection device
    device, such as a fuse or circuit-breaker, designed to interrupt the circuit when the current flow exceeds a predetermined value for a predetermined time
    [IEC 60092-507, ed. 2.0 (2008-01)]

    FR

    dispositif de protection contre les surintensités
    dispositif, fusible ou disjoncteur, conçu pour interrompre le circuit lorsque le flux de courant dépasse une valeur prédéterminée pendant une durée prédéterminée
    [IEC 60092-507, ed. 2.0 (2008-01)]

    Тематики

    • аппарат, изделие, устройство...

    Синонимы

    EN

    FR

    Русско-французский словарь нормативно-технической терминологии > аппарат защиты от сверхтока

  • 16 первичный двигатель

    1. moteur primaire

     

    первичный двигатель
    Любое устройство, обеспечивающее создание механической энергии, необходимой для выполнения управляющим устройством функции передачи; таким устройством может быть электрическое управляющее устройство, электрический клапан, механизм с электрическим приводом или управляющее устройство с отсчетом времени.
    Примечание. Это может быть механизм, накапливающий механическую энергию (например, часовая пружина), электромагнитное устройство (например, электромотор или шаговый соленоид), электротермическое устройство (например, нагревательный элемент регулятора энергии) или любой другой механизм, создающий механическую энергию.
    [ГОСТ IЕС 60730-1-2011]

    EN

    prime mover
    any device used to produce the mechanical energy required to provide the transmission for an automatic control, such as an electrically operated control, an electrically operated valve, an electrically operated mechanism or a timebased control
    Note 1 to entry: It may be a mechanical storage device (for example, a clockwork spring), an electromagnetic device (for example, an electric motor, or stepping solenoid), an electrothermal device (for example, the heating element of an energy regulator) or any other mechanism producing mechanical energy.
    [IEC 60730-1, ed. 5.0 (2013-11)]

    FR

    moteur primaire
    tout dispositif fournissant l'énergie mécanique nécessaire à la transmission pour un dispositif de commande automatique, tel qu'un dispositif de commande à fonctionnement électrique, une électrovanne, un mécanisme à fonctionnement électrique ou un dispositif de commande à base de temps
    Note 1 à l'article: Ce peut être un mécanisme à accumulation d'énergie (tel qu'un moteur à ressort), un dispositif électromagnétique (tel qu'un moteur électrique, un électro-aimant pas à pas), un dispositif électrothermique (tel que l'élément chauffant d'un régulateur d'énergie), ou toute autre source d'énergie mécanique
    [IEC 60730-1, ed. 5.0 (2013-11)]

    Тематики

    • электротехника, основные понятия

    EN

    FR

    Русско-французский словарь нормативно-технической терминологии > первичный двигатель

  • 17 полное время отключения выключателя

    1. durée de coupure

     

    время отключения
    Интервал времени между началом времени размыкания контактного коммутационного аппарата (или преддугового времени плавкого предохранителя) и моментом угасания дуги.
    МЭК 60050(441-17-39).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    полное время отключения
    Интервал времени между началом операции отключения и окончанием погасания дуги во всех полюсах.
    [ ГОСТ Р 52565-2006]

    полное время отключения выключателя
    Время срабатывания расцепителей, механизма выключателя, расхождения силовых контактов и окончания гашения дуги в дугогасительных камерах (используется при проверке селективности защиты).
    [А.В.Беляев. Выбор аппаратуры, защит и кабелей в сетях 0,4 кВ. - Л.: Энергоатомиздат. 1988.]

    EN

    break-time
    the interval of time between the beginning of the opening time of a mechanical switching device (or the pre-arcing time of a fuse) and the end of the arcing time
    [IEV number 441-17-39]

    FR

    durée de coupure
    intervalle de temps entre le début de la durée d'ouverture d'un appareil mécanique de connexion, ou le début de la durée de préarc d'un fusible, et la fin de la durée d'arc
    [IEV number 441-17-39]

    См. также собственное время отключения

    Коммутационный цикл

    0732_1

    Параллельные тексты EN-RU

    1

    Breaker closed - apply auxillary power to activate the release.

    Выключатель во включенном положении. Начинает прикладываться внешнее усилие, направленное на отключение.

    2

    Contact separation - start of arc.

    Наличие зазора между разомкнутыми контактами. Возникновение дуги.

    3

    Extinction of arc.

    Погасание дуги.

    4

    Breacer open - initiation of closing movement.

    Выключатель в отключенном положении. Инициирование включения.

    5

    Current starts to flow in the conducting path (preignition)

    Начало протекания тока (начало горения дуги в изоляционном промежутке между разомкнутыми контактами).

    6

    Contact touch.

    Соприкосновение контактов.

    -

    Opening time.

    Собственное время отключения.

    -

    Arcing time

    Время дуги.

    -

    Make time.

    Время включения.

    -

    Break time/Interrupting time

    Полное время отключения

    -

    Dead time.

    Бестоковая пауза.

    -

    Closing time.

    Собственное время включения.

    -

    Reclosing time.

    Цикл автоматического повторного включения.

     

    [Siemens]

    [Перевод Интент]

    Тематики

    Синонимы

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > полное время отключения выключателя

  • 18 разъединитель

    1. sectionneur

     

    разъединитель
    Контактный коммутационный аппарат, в разомкнутом положении отвечающий требованиям к функции разъединения.
    Примечание.
    1 Это определение отличается от формулировки МЭК 60050(441-14-05), поскольку требования к функции разъединения не ограничиваются соблюдением изолирующего промежутка.
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
    2 Разъединитель способен включать и отключать цепь с незначительным током или при незначительном изменении напряжения на зажимах каждого из полюсов разъединителя.
    Разъединитель может проводить токи в нормальных условиях работы, а также в течение определенного времени в аномальных условиях работы выдерживать токи короткого замыкания.

    0043 Условное обозначение контакта разъединителя

    [ ГОСТ Р 50030. 3-99 ( МЭК 60947-3-99)]

    разъединитель
    Контактный коммутационный аппарат, который обеспечивает в отключенном положении изоляционный промежуток, удовлетворяющий нормированным требованиям.
    Примечания
    1 Разъединитель способен размыкать и замыкать цепь при малом токе или малом изменении напряжения на выводах каждого из его полюсов. Он также способен проводить токи при нормальных условиях в цепи и проводить в течение нормированного времени токи при ненормальных условиях, таких как короткое замыкание.
    2 Малые токи - это такие токи, как емкостные токи вводов, шин, соединений, очень коротких кабелей, токи постоянно соединенных ступенчатых сопротивлений выключателей и токи трансформаторов напряжения и делителей. Для номинальных напряжений до 330 кВ включительно ток, не превышающий 0,5 А, считается малым током по этому определению; для номинального напряжения от 500 кВ и выше и токов, превышающих 0,5 А, необходимо проконсультироваться с изготовителем, если нет особых указаний в руководствах по эксплуатации разъединителей.
    3 К малым изменениям напряжения относятся изменения напряжения, возникающие при шунтировании регуляторов индуктивного напряжения или выключателей.
    4 Для разъединителей номинальным напряжением от 110 кВ и выше может быть установлена коммутация уравнительных токов.
    [ ГОСТ Р 52726-2007]

    EN

    disconnector
    a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements
    NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit.
    [IEV number 441-14-05]

    disconnector

    IEV 441-14-05 is applicable with the following additional notes:
    NOTE 1
    "Negligible current" implies currents such as the capacitive currents of bushings, busbars, connections, very short lengths of cable, currents of permanently connected grading impedances of circuit-breakers and currents of voltage transformers and dividers. For rated voltages of 420 kV and below, a current not exceeding 0,5 A is a negligible current for the purpose of this definition; for rated voltage above 420 kV and currents exceeding 0,5 A, the manufacturer should be consulted.
    "No significant change in voltage" refers to such applications as the by-passing of induction voltage regulators or circuit-breakers.
    NOTE 2
    For a disconnector having a rated voltage of 52 kV and above, a rated ability of bus transfer current switching may be assigned
    [IEC 62271-102]

    FR

    sectionneur
    appareil mécanique de connexion qui assure, en position d'ouverture, une distance de sectionnement satisfaisant à des conditions spécifiées
    NOTE – Un sectionneur est capable d'ouvrir et de fermer un circuit lorsqu'un courant d'intensité négligeable est interrompu ou établi, ou bien lorsqu'il ne se produit aucun changement notable de la tension aux bornes de chacun des pôles du sectionneur. Il est aussi capable de supporter des courants dans les conditions normales du circuit et de supporter des courants pendant une durée spécifiée dans des conditions anormales telles que celles du court-circuit.
    [IEV number 441-14-05]

    Указанные в 5.3.2 перечислениях а)-d) устройства отключения ( выключатель-разъединитель, разъединитель или выключатель) должны:

    • изолировать электрооборудование от цепей питания и иметь только одно положение ОТКЛЮЧЕНО (изоляция) и одно положение ВКЛЮЧЕНО, четко обозначаемые символами «О» и «I» [МЭК 60417-5008 (DB:2002-10) и МЭК 60417-5007 (DB:2002-10), см. 10.2.2];
    • иметь видимое разъединение или индикатор положения, который может указывать положение ОТКЛЮЧЕНО только в случае, если все контакты в действительности открыты, т.е. разомкнуты и удалены друг от друга на расстояние, удовлетворяющее требованиям по изолированию;
    • быть снабжены расположенным снаружи ручным приводом (например, ручкой). Исключение для управляемых внешним источником энергии, когда воздействие вручную невозможно при наличии иного внешнего привода. Если внешние приводы не используются для выполнения аварийных функций управления, то рекомендуется применять ЧЕРНЫЙ и СЕРЫЙ цвета для окраски ручного привода (см. 10.7.4 и 10.8.4);
    • обладать средствами для запирания в положении ОТКЛЮЧЕНО (например, с помощью висячих замков). При таком запирании возможность как дистанционного, так и местного включения должна быть исключена;

    [ ГОСТ Р МЭК 60204-1-2007]


    Разъединители служат для создания видимого разрыва, отделяющего выводимое в ремонт оборудование от токоведущих частей, находящихся под напряжением, для безопасного производства работ.
    Разъединители не имеют дугогасящих устройств и поэтому предназначаются для включения и отключения электрических цепей при отсутствии тока нагрузки и находящихся только под напряжением или даже без напряжения. Лишь в некоторых случаях допускается включение и отключение разъединителями небольших токов, значительно меньше номинальных.
    Разъединители используются также при различного рода переключениях в схемах электрических соединений подстанций, например при переводе присоединений с одной системы шин на другую.
    Требования, предъявляемые к разъединителям с точки зрения оперативного обслуживания, следующие:

    1. Разъединители в отключенном положении должны создавать ясно видимый разрыв цепи, соответствующий классу напряжения установки.
    2. Приводы разъединителей должны иметь устройства фиксации в каждом из двух оперативных положений: включенном и отключенном. Кроме того, они должны иметь надежные упоры, ограничивающие поворот главных ножей на угол больше заданного.
    3. Опорные изоляторы и изолирующие тяги должны выдерживать механическую нагрузки при операциях.
    4. Главные ножи разъединителей должны иметь блокировку с ножами стационарных заземлителей и не допускать возможности одновременного включения тех и других.
    5. Разъединители должны беспрепятственно включаться и отключаться при любых наихудших условиях окружающей среды (например, при обледенении).
    6. Разъединители должны иметь надлежащую изоляцию, обеспечивающую не только надежную работу при возможных перенапряжениях и ухудшении атмосферных условий (гроза, дождь, туман), но и безопасное обслуживание.

    [ http://forca.ru/stati/podstancii/obsluzhivanie-razediniteley-otdeliteley-i-korotkozamykateley.html]


    Разъединители применяются для коммутации обесточенных при помощи выключателей участков токоведущих систем, для переключения РУ с одной ветви на другую, а также для отделения на время ревизии или ремонта силового электротехнического оборудования и создания безопасных условий от смежных частей линии, находящихся под напряжением. Разъединители способны размыкать электрическую цепь только при отсутствии в ней тока или при весьма малом токе. В отличие от выключателей разъединители в отключенном состоянии образуют видимый разрыв цепи. После отключения разъединителей с обеих сторон объекта, например выключателя или трансформатора, они должны заземляться с обеих сторон либо при помощи переносных заземлителей, либо специальных заземляющих ножей, встраиваемых в конструкцию разъединителя.
    [ http://relay-protection.ru/content/view/46/8/1/1/]


    Параллельные тексты EN-RU

    b) disconnector, with or without fuses, in accordance with IEC 60947-3, that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector;
    [IEC 60204-1-2006]

    б) разъединитель с или без предохранителей, соответствующий требованиям МЭК 60947-3 со вспомогательным контактом, срабатывающим до того, как разомкнутся главные контакты разъединителя, используемым для коммутации другого аппарата, отключающего питание цепей нагрузки.
    [Перевод Интент]

    Тематики

    • высоковольтный аппарат, оборудование...
    • релейная защита
    • электротехника, основные понятия

    Классификация

    >>>

    EN

    DE

    FR

    Смотри также

    Русско-французский словарь нормативно-технической терминологии > разъединитель

  • 19 timer

    1) (a person who, or a device which, measures the time taken by anything: a three-minute egg-timer.) chronométreur/-euse; chronomètre
    2) (a clock-like device which sets something off or switches something on or off at a given time.) minuterie

    English-French dictionary > timer

  • 20 предельный ток селективности

    1. courant limite

     

    предельный ток селективности Is Токовая координата точки пересечения полной время-токовой характеристики защитного аппарата со стороны нагрузки и преддуговой (для плавких предохранителей) время-токовой характеристики или время-токовой характеристики расцепления второго защитного аппарата.

    Предельный ток селективности (см. рисунок А.1) — это предельное значение тока:

    • ниже которого при последовательном соединении двух аппаратов защиты от сверхтоков защитный аппарат со стороны нагрузки завершает операцию отключения, чтобы воспрепятствовать началу действия второго защитного аппарата (т. е. обеспечивается селективность);
    • выше которого при последовательном соединении двух аппаратов защиты от сверхтоков защитный аппарат со стороны нагрузки может не успеть вовремя завершить операцию отключения, чтобы воспрепятствовать началу действия второго защитного аппарата (т. е. селективность не обеспечивается).
    0026 I - ожидаемый ток короткого замыкания;
    Is - предельный ток селективности;
    Icu - номинальная предельная наибольшая отключающая способность;
    А - преддуговая характеристика плавкого предохранителя;
    В - рабочая характеристика плавкого предохранителя;
    С - рабочая характеристика нетокоограничивающего выключателя (N) (время отключения/ток и I2t/ток) Примечания.
    1. А считают нижним пределом, В и С - верхними пределами.
    2. Недиабатическая зона для I2t показана пунктиром Рис. А1.
    Координация по сверхтокам между автоматическим выключателем и предохранителем
    или резервной защитой, осуществляемой предохранителем.
    [ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]

    EN

    selectivity-limit current
    the current coordinate of the intersection between the maximum break time-current characteristic of the protective device on the load side and the pre-arcing (for fuses) or tripping (for residual current devices) time-current characteristic of the other protective device
    [IEV number 442-05-60]

    FR

    courant limite
    coordonnée du courant de l'intersection entre la caractéristique de durée maximale de coupure temps-courant du dispositif de protection côté aval et la caractéristique temps-courant de pré-arc (pour les fusibles) ou de déclenchement (pour les dispositifs de coupure différentiels) de l'autre dispositif de protection.
    [IEV number 442-05-60]

    Тематики

    Синонимы

    • Is

    EN

    DE

    FR

    Русско-французский словарь нормативно-технической терминологии > предельный ток селективности

См. также в других словарях:

  • Device independence — is the process of making a software application be able to function on a wide variety of devices regardless of the local hardware on which the software is used. Contents 1 Desktop computing 2 Virtualization and Emulation 3 World Wide Web Usage …   Wikipedia

  • Time travel in fiction — Time travel is a common theme in science fiction and is depicted in a variety of media. Literature Time travel can form the central theme of a book, or it can be simply a plot device. Time travel in fiction can ignore the possible effects of the… …   Wikipedia

  • Time Bokan — Time Fighters (Time Bokan) タイムボカン TV anime Directed by Hiroshi Sasagawa Studio Tatsunoko Productions Network F …   Wikipedia

  • device — 1 Device, contrivance, gadget, contraption mean something usually of a mechanical character which is invented as a means of doing a particular piece of work or of effecting a given end. Device is the most widely applicable of these terms; it may… …   New Dictionary of Synonyms

  • Device Bay — was a standard jointly developed by Compaq, Intel and Microsoft in 1997, as a simple way to add, remove, and share hardware devices. Originally intended to be introduced in the second half of 1998, Device Bay was never finalized and has long… …   Wikipedia

  • Time — Time, n.; pl. {Times}. [OE. time, AS. t[=i]ma, akin to t[=i]d time, and to Icel. t[=i]mi, Dan. time an hour, Sw. timme. [root]58. See {Tide}, n.] 1. Duration, considered independently of any system of measurement or any employment of terms which… …   The Collaborative International Dictionary of English

  • Time ball — Time Time, n.; pl. {Times}. [OE. time, AS. t[=i]ma, akin to t[=i]d time, and to Icel. t[=i]mi, Dan. time an hour, Sw. timme. [root]58. See {Tide}, n.] 1. Duration, considered independently of any system of measurement or any employment of terms… …   The Collaborative International Dictionary of English

  • Time bargain — Time Time, n.; pl. {Times}. [OE. time, AS. t[=i]ma, akin to t[=i]d time, and to Icel. t[=i]mi, Dan. time an hour, Sw. timme. [root]58. See {Tide}, n.] 1. Duration, considered independently of any system of measurement or any employment of terms… …   The Collaborative International Dictionary of English

  • Time bill — Time Time, n.; pl. {Times}. [OE. time, AS. t[=i]ma, akin to t[=i]d time, and to Icel. t[=i]mi, Dan. time an hour, Sw. timme. [root]58. See {Tide}, n.] 1. Duration, considered independently of any system of measurement or any employment of terms… …   The Collaborative International Dictionary of English

  • Time book — Time Time, n.; pl. {Times}. [OE. time, AS. t[=i]ma, akin to t[=i]d time, and to Icel. t[=i]mi, Dan. time an hour, Sw. timme. [root]58. See {Tide}, n.] 1. Duration, considered independently of any system of measurement or any employment of terms… …   The Collaborative International Dictionary of English

  • Time detector — Time Time, n.; pl. {Times}. [OE. time, AS. t[=i]ma, akin to t[=i]d time, and to Icel. t[=i]mi, Dan. time an hour, Sw. timme. [root]58. See {Tide}, n.] 1. Duration, considered independently of any system of measurement or any employment of terms… …   The Collaborative International Dictionary of English

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»