1 длительный допустимый ток
- courant permanent admissible, m
- courant admissible, m
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Русско-французский словарь нормативно-технической терминологии > длительный допустимый ток
-
2 шинопровод
система сборных шин
шинопровод
Устройство, представляющее собой систему проводников, состоящее из шин, установленных на опорах из изоляционного материала или в каналах, коробах или подобных оболочках, и прошедшее типовые испытания.
Устройство может состоять из следующих элементов:
- прямые секции с узлами ответвления или без них;
- секции для изменения положения фаз, разветвления, поворота, а также вводные и переходные;
- секции ответвленные.
Примечание — Термин «шинопровод» не определяет геометрическую форму, габариты и размеры проводников.
(МЭС 441-12-07, с изменением)
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]
шинопровод
Жесткий токопровод до 1 кВ заводского изготовления, поставляемый комплектными секциями.
[ПУЭ]
шинопровод
Жесткий токопровод напряжением до 1000 В заводского изготовления, поставляемый комплектными секциями.
[ОСТ 36-115-85]
шинопровод
Жесткий токопровод напряжением до 1 кВ, предназначенный для передачи и распределения электроэнергии, состоящий из неизолированных или изолированных проводников (шин) и относящихся к ним изоляторов, защитных оболочек, ответвительных устройств, поддерживающих и опорных конструкций.
[ ГОСТ Р 53310-2012]EN
busway
A prefabricated assembly of standard lengths of busbars rigidly supported by solid insulation and enclosed in a sheet-metal housing.
[ http://www.answers.com/topic/busway]
busway
Busway is defined by the National Electrical Manufacturers Association (NEMA) as a prefabricated electrical distribution system consisting of bus bars in a protective enclosure, including straight lengths, fittings, devices, and accessories. Busway includes bus bars, an insulating and/or support material, and a housing.
[ http://electrical-engineering-portal.com/siemens-busway-purpose-and-definition]1.1. Шинопроводы по назначению подразделяются на:
- распределительные, предназначенные для распределения электрической энергии;
- магистральные, предназначенные для передачи электрической энергии от источника к месту распределения (распределительным пунктам, распределительным шинопроводам) или мощным приемникам электрической энергии.
1.2. По конструктивному исполнению шинопроводы подразделяются на:
- трехфазные;
- трехфазные с нулевым рабочим проводником;
- трехфазные с нулевым рабочим и нулевым защитным проводником.
2. Основные параметры и размеры
2.1. Основные элементы шинопроводов
2.1.1. Основными элементами распределительных шинопроводов являются:а) прямые секции - для прямолинейных участков линии, имеющие места для присоединения одного или двух ответвительных устройств для секций длиной до 2 м включительно, двух, трех, четырех или более - для секций длиной 3 м;
б) прямые прогоночные секции - для прямолинейных участков линий, где присоединение ответвительных устройств не требуется;
в) угловые секции - для поворотов линии на 90° в горизонтальной и вертикальной плоскостях;
г) вводные секции или вводные коробки с коммутационной, защитной и коммутационной аппаратурой или без нее - для подвода питания к шинопроводам кабелем, проводами или шинопроводом;
д) переходные секции или устройства - для соединения двух шинопроводов на различные номинальные токи или шинопроводов разных конструкций;
е) ответвительные устройства (коробки, штепсели) - для разъемного присоединения приемников электрической энергии. Коробки должны выпускаться с разъединителем, с разъединителем и с предохранителями или с автоматическим выключателем;
з) присоединительные фланцы - для сочленения оболочек шинопроводов с оболочками щитов или шкафов;
и) торцовые крышки (заглушки) - для закрытия торцов крайних секций шинопровода;
к) устройства для крепления шинопроводов к элементам строительных конструкций зданий и сооружений;2.1.2. Основными элементами магистральных шинопроводов являются:
а) прямые секции - для прямолинейных участков линий;
б) угловые секции - для поворотов линий на 90° в горизонтальной и вертикальной плоскостях;
в) тройниковые секции - для разветвления в трех направлениях под углом 90° в горизонтальной и вертикальной плоскостях;
г) подгоночные секции - для подгонки линии шинопроводов до необходимой длины;
д) разделительные секции с разъединителем - для секционирования магистральных линий шинопроводов;
е) компенсационные секции - для компенсации температурных изменений длины линии шинопроводов;
ж) переходные секции - для соединения шинопроводов на разные номинальные токи;
з) ответвительные устройства (секции, коробки) - для неразборного, разборного или разъемного присоединения распределительных пунктов, распределительных шинопроводов или приемников электрической энергии. Коробки должны выпускаться с разъединителем, с разъединителем и предохранителями или с автоматическим выключателем; секции могут выпускаться без указанных аппаратов;
и) присоединительные секции - для присоединения шинопроводов к комплектным трансформаторным подстанциям;
к) проходные секции - для прохода через стены и перекрытия;
л) набор деталей и материалов для изолирования мест соединения секций шинопроводов с изолированными шинами;
м) устройства для крепления шинопроводов к элементам строительных конструкций зданий и сооружений;
н) крышки (заглушки) торцовые и угловые для закрытия торцов концевых секций шинопровода и углов.
2.2.3. В зависимости от вида проводников токопроводы подразделяются на гибкие (при использовании проводов) и жесткие (при использовании жестких шин).
Жесткий токопровод до 1 кВ заводского изготовления, поставляемый комплектными секциями, называется шинопроводом.
В зависимости от назначения шинопроводы подразделяются на:- магистральные, предназначенные в основном для присоединения к ним распределительных шинопроводов и силовых распределительных пунктов, щитов и отдельных мощных электроприемников;
- распределительные, предназначенные в основном для присоединения к ним электроприемников;
- троллейные, предназначенные для питания передвижных электроприемников;
- осветительные, предназначенные для питания светильников и электроприемников небольшой мощности.
[ПУЭ, часть 2]
[ http://electrical-engineering-portal.com/siemens-busway-purpose-and-definition]
[ http://electrical-engineering-portal.com/standards-and-applications-of-medium-voltage-bus-duct]
Конструкция шинопровода на среднее напряжениеПараллельные тексты EN-RU
A major advantage of busway is the ease in which busway sections are connected together.
Electrical power can be supplied to any area of a building by connecting standard lengths of busway.
It typically takes fewer man-hours to install or change a busway system than cable and conduit assemblies.Основное преимущество шинопровода заключается в легкости соединения его секций.
Соединяя эти стандартные секции можно легко снабдить электроэнергией любую часть здания.
Как правило, установить или изменить систему шинопроводов занимает гораздо меньше времени, чем выполнить аналогичные работы, применяя разводку кабелем в защитных трубах.[ http://electrical-engineering-portal.com/siemens-busway-purpose-and-definition]
The total distribution system frequently consists of a combination of busway and cable and conduit.
In this example power from the utility company is metered and enters the plant through a distribution switchboard.
The switchboard serves as the main disconnecting means.Как правило, распределение электроэнергии производится как через шинопроводы, так и через проложенные в защитных трубах кабели.
В данном примере поступающая от питающей сети электроэнергия измеряется на вводе в главное распределительный щит (ГРЩ).
ГРЩ является главным коммутационным устройством.
The feeder on the left feeds a distribution switchboard, which in turn feeds a panelboard and a 480 volt, three-phase, three-wire (3Ø3W) motor.
Распределительная цепь, изображенная слева, питает распределительный щит, который в свою очередь питает групповой щиток и электродвигатель.
Электродвигатель получает питание через трехфазную трехпроводную линию напряжением 480 В.The middle feeder feeds another switchboard, which divides the power into three, three-phase, three-wire circuits. Each circuit feeds a busway run to 480 volt motors.
Средняя (на чертеже) распределительная цепь питает другой распределительный щит, от которого электроэнергия распределяется через три трехфазные трехпроводные линии на шинопроводы.
Каждый шинопровод используется для питания электродвигателей напряжением 480 В.The feeder on the right supplies 120/208 volt power, through a step-down transformer, to lighting and receptacle panelboards.
Распределительная цепь, изображенная справа, питает напряжением 120/208 В через понижающий трансформатор щитки для отдельных групп светильников и штепсельных розеток.
Branch circuits from the lighting and receptacle panelboards supply power for lighting and outlets throughout the plant.
[ http://electrical-engineering-portal.com/siemens-busway-purpose-and-definition]Групповые электрические цепи, идущие от групповых щитков, предназначены для питания всех светильников и штепсельных розеток предприятия.
[Перевод Интент]Selection of the busbar trunking system based on voltage drop.
[Legrand]Выбор шинопровода по падению напряжения.
[Перевод Интент]
Недопустимые, нерекомендуемые
Примечание(1)- Мнение автора карточкиТематики
- изделие электромонтажное
- электропроводка, электромонтаж
Обобщающие термины
Близкие понятия
- электропроводки, выполненные шинопроводами
Действия
- выбор шинопровода по...
- крепление шинопровода к опорным конструкциям
- монтаж шинопроводов
- применение шинопроводов в пожароопасных зонах
- проектирование шинопровода
- прокладка шинопровода
Сопутствующие термины
- вертикальный участок шинопровода
- горизонтальный участок шинопровода
- прямой участок шинопровода
- устройства для крепления шинопроводов
- шинопровод переменного тока на 1600 А
- электрическая сеть, выполняемая шинопроводами
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > шинопровод
-
3 внутригородской район
внутригородской район
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]EN
inner city
1) Part of a city at or near the centre, especially a slum area where poor people live in bad housing.
2) City centres of many industrialized countries which exhibit environmental degradation. The numerous and highly competitive activities entailing land use overwhelm the limited space and create a situation of overcrowding, functional incompatibility and cultural degradation. Inner city areas have a high level of commercial specialization, a large number of offices and a sizeable daytime population. At the same time, city centres generally remain a sort of ghetto for a permanent, low-income population living in run-down housing and enjoying little in the way of public services and civic amenities. The concentration of service industries inevitably entails the replacement of traditional housing and shops by office blocks, the provision of basic utilities at the expense of civic amenities and the provision of major access roads which eat up urban space. Structures of historic origin are often unable to meet modern requirements and, notwithstanding their value, frequently face demolition.
(Source: PHC / WPR)
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > внутригородской район
-
4 энергия ГЭС
энергия ГЭС
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]EN
hydroelectric energy
The free renewable source of energy provided by falling water that drives the turbines. Hydropower is the most important of the regenerable energy sources because of its highest efficiency at the energy conversion. There are two types of hydroelectric power plants: a) run-of-river power plants for the use of affluent water; b) storage power plants (power stations with reservoir) where the influx can be regulated with the help of a reservoir. Mostly greater differences in altitudes are being used, like mountain creeks. Power stations with reservoirs are generally marked by barrages with earth fill dam or concrete dams. Though hydropower generally can be called environmentally acceptable, there exist also some problems: a) change of groundwater level and fill up of the river bed with rubble. b) Risk of dam breaks. c) Great demand for land space for the reservoir. d) Diminution, but partly also increase of value of recreation areas. As the hydropowers of the world are limited, the world energy demand however is rising, finally the share of hydropower will decrease. (Source: PORT / PHC / PZ)
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > энергия ГЭС
-
5 Всемирная сеть
Всемирная сеть
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]EN
World Wide Web
A graphical, interactive, hypertext information system that is cross-platform and can be run locally or over the global Internet. The Web consists of Web servers offering pages of information to Web browsers who view and interact with the pages. Pages can contain formatted text, background colors, graphics, as well as audio and video clips. Simple links in a Web page can cause the browser to jump to a different part of the same page or to a page on a Web server halfway around the world. Web pages can be used to send mail, read news, and download files. A Web address is called a URL. (Source: CAMER)
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > Всемирная сеть
-
6 максимальная толщина шва
максимальная толщина шва
Значение, измеряемое от самой глубокой точки проплавления углового шва или крайней точки корня стыкового шва до наивысшей точки выпуклости шва.
Примечание
Измерение обычно проводят по поперечному сечению шва.
[ ГОСТ Р ИСО 17659-2009] [ISO 17659:2002]EN
maximum throat thickness
Dimension measured from the deepest point of the penetration in fillet welds or the extremity of the root run in butt welds to the highest point of the excess weld metal.
Note
This is usually measured from a cross-section.
[ ГОСТ Р ИСО 17659-2009] [ISO 17659:2002]FR
gorge totale (soudures d'angle)
épaisseur totale (soudures bout а bout)
Soudures d'angle distance mesurée entre le point le plus bas de la pénétration et le point le plus haut de la surépaisseur soudures bout а bout distance mesurée entre le point le plus bas de la passe de fond et le point le plus haut de la surépaisseur.
Note
Cette distance est habituellement mesurée sur une coupe transversale.
[ ГОСТ Р ИСО 17659-2009] [ISO 17659:2002]Тематики
- сварка, резка, пайка
EN
FR
Русско-французский словарь нормативно-технической терминологии > максимальная толщина шва
-
7 водная эрозия
водная эрозия
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]EN
water erosion
The breakdown of solid rock into smaller particles and its removal by water. As weathering, erosion is a natural geological process, but more rapid soil erosion results from poor land-use practices, leading to the loss of fertile topsoil and to the silting of dams, lakes, rivers and harbours. There are three classes of erosion by water. a) Splash erosion occurs when raindrops strike bare soil, causing it to splash, as mud, to flow into spaces in the soil and to turn the upper layer of soil into a structureless, compacted mass that dries with a hard, largely impermeable crust. b) Surface flow occurs when soil is removed with surface run-off during heavy rain. c) Channelized flow occurs when a flowing mixture of water and soil cuts a channel, which is then deepened by further scouring. A minor erosion channel is called a rill, a larger channel a gully. (Source: ALL)
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > водная эрозия
-
8 присоединенное положение (выдвижной части)
присоединенное положение
Положение съемной или выдвижной части, в котором она полностью присоединена для выполнения предназначенной функции.
[ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]
присоединенное положение
Положение выдвижной отделяемой части НКУ, при котором она полностью соединена с ним для выполнения заданной ей функции.
[ ГОСТ Р МЭК 61439.1-2013]EN
service position (of a removable part)
connected position (of a removable part)
the position of a removable part in which it is fully connected for its intended function
[IEV number 441-16-25]
connected position
position of a removable part when it is fully connected for its intended function
[IEC 61439-1, ed. 2.0 (2011-08)]FR
position raccordée
position d'une partie amovible lorsque celle-ci est entièrement raccordée pour la fonction à laquelle elle est destinée
[IEC 61439-1, ed. 2.0 (2011-08)]
Параллельные тексты EN-RU
Рис. Schneider Electric
Draw-in
- The functional unit is operational.
- Power and auxiliaries are connected.
[Schneider Electric]Присоединённое положение
- Функциональный блок присоединён для выполнения своей функции.
- Главная и вспомогательные цепи присоединены.
[Перевод Интент]
Рис. Schneider Electric
The withdrawable drawers have 3 positions: connected, disconnected and testing.
The “ plug-in / test / draw-out” positions are mechanically marked by an indexing device associated with a mechanical indicator on the drawer sides.
[Schneider Electric]Выдвижные ящики имеют три положения: присоединенное, отсоединенное и испытательное.
Выдвижные ящики имеют три положения: присоединенное, испытательное и отсоединенное. Указанные положения промаркированы на боковых сторонах выдвижных ящиков и однозначно определяются механическим указателем.
[Перевод Интент]Тематики
- НКУ (шкафы, пульты,...)
- выключатель автоматический
Обобщающие термины
Синонимы
EN
- connected position
- connected position (of a removable part)
- draw-in
- plug-in position
- run position
- SERVICE
- service position (of a removable part)
FR
Русско-французский словарь нормативно-технической терминологии > присоединенное положение (выдвижной части)
9 долгосрочное прогнозирование
долгосрочное прогнозирование
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]
долгосрочное прогнозирование
Оценка будущего развития экономики, научно-технического прогресса, социальных изменений в обществе в долгосрочном периоде. В экономико-математических прогнозах эти стороны развития рассматриваются в единстве. Д.п. обычно относится к периоду в 10 - 15 лет, однако есть и так называемые сверхдолгосрочные прогнозы, или, правильнее, дальнесрочные, охватывающие существенно большие промежутки времени. Они, например, относятся к энергетике, градостроительству, лесному хозяйству, к состоянию природной среды. Как правило, подобные прогнозы существенно менее детализированы, чем кратко- и среднесрочные, в них шире применяются вероятностные оценки (см. Вероятность), а часто — и качественные суждения. Строятся научно-технические, социально-экономические и демографические прогнозы, каждый из которых объединяет и взаимоувязывает результаты многих частных прогнозов: развития тех или иных отраслей техники, производства товаров народного потребления, совершенствования экономического механизма и др. Основные методы прогнозирования в экономике, включая долгосрочное, приводятся в статье Прогнозирование.
[ http://slovar-lopatnikov.ru/]EN
long-term forecasting
The act or process of predicting and calculating the likely conditions or occurrences for an extended and future point in time, often involving the study and analysis of pertinent data. (Source: RHW / MHE)
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > долгосрочное прогнозирование
10 разрушение лесного покрова
разрушение лесного покрова
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]EN
forest cover destruction
Destruction of forests is carried out in many countries in order to provide new land for agricultural or livestock purposes. It is often done without factors such as climate and topography having been sufficiently studied and on lands where slope nature of the soil or other physiographic characteristics clearly indicate that the land involved is suitable only for forest. Although these practices may lead to a temporary increase in productivity, there are also many indications that in the long run there is usually a decrease in productivity per unit of surface and that erosion and irreversible soil deterioration often accompany this process. Many factors contribute to forest cover destruction: timber production, clearance for agriculture, cutting for firewood and charcoal, fires, droughts, strip mining, pollution, urban development, population pressures, and warfare. (Source: WPR)
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > разрушение лесного покрова
11 вакуумный контактор (пускатель)
вакуумный контактор (пускатель)
Контактор (пускатель), у которого главные контакты размыкаются и замыкаются внутри оболочки с сильно разреженной атмосферой.
[ ГОСТ Р 50030.4.1-2002 (МЭК 60947-4-1-2000)]EN
vacuum contactor (or starter)
contactor (or starter) in which the main contacts open and close within a highly evacuated envelope
[IEC 60947-4-1, ed. 3.0 (2009-09)]FR
contacteur (ou démarreur) sous vide
contacteur (ou démarreur) dont les contacts principaux s'ouvrent et se ferment à l'intérieur d'une enveloppe à basse pression
[IEC 60947-4-1, ed. 3.0 (2009-09)]Параллельные тексты EN-RU
Vacuum contactors are mainly used for the switching of motors, transformers, capacitors in AC power lines.
They can be installed in multi-stack cubicles.
A vacuum contactor comprises several assemblies such as switching mechanism including vacuum interrupters, magnetic actuator, high strength molded front cover and auxiliary devices.
Actuating is available either at instantaneous or continuous excitation.
[LS Industrial Systems]Вакуумные контакторы предназначены в основном для коммутации силовых цепей переменного тока электродвигателей, трансформаторов и конденсаторов.
Контакторы пригодны для установки в комплектные устройства в несколько ярусов.
Вакуумный контактор состоит из следующих узлов: коммутационный механизм с вакуумной дугогасительной камерой, электромагнитный привод, прочная пластмассовая передняя панель и вспомогательные устройства.
Включение и отключение контактора возможно как подачей кратковременного, так и непрерывного сигнала на электромагнитный привод.
[Перевод Интент]
Вакуумный контактор среднего напряжения выдвижного исполнения с предохранителями
Рис. LS Industrial Systems1
Передняя панель
2
Окно проверки состояния предохранителя
3
Электрический соединитель
4
Unlock button (Interlock lever)
Кнопка разблокировки рычага
5
Ручка (предназначена для того, чтобы вдвигать и выдвигать контактор)
6
ON/OFF indicator
Указатель коммутационного положения контактора (ВКЛ/ОТКЛ.)
7
Счетчик операционных циклов
8
Кнопка ручного отключения контактора
10
Выдвижной лоток
11
Блокировочный рычаг
12
Блокировочная кнопка
13
Hole for Interlock lever insertion
Отверстие для вставки блокировочного рычага
14
Test/Run indicator
Индикатор положений Испытательное/Присоединенное
15
Корзина
16
Конденсаторный источник питания
17
Кожух предохранителя
Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- контакторы и пускатели
EN
FR
Русско-французский словарь нормативно-технической терминологии > вакуумный контактор (пускатель)
12 государственный сектор
государственный сектор
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]EN
public sector
Segment of the economy run to some degree by government, including national and local governments, government-owned firms and quasi-autonomous non-government organizations. (Source: ODE)
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > государственный сектор
13 программа сохранения природы
программа сохранения природы
—
[ http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]EN
nature conservation programme
An organized group of activities and procedures, often run by a government agency or a nonprofit organization, to preserve and protect elements of the natural world such as mountains, trees, animals or rivers. (Source: RHW)
[http://www.eionet.europa.eu/gemet/alphabetic?langcode=en]Тематики
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > программа сохранения природы
См. также в других словарях:
The run — Run Run, n. 1. The act of running; as, a long run; a good run; a quick run; to go on the run. [1913 Webster] 2. A small stream; a brook; a creek. [1913 Webster] 3. That which runs or flows in the course of a certain operation, or during a certain … The Collaborative International Dictionary of English
The run of the mill — Run Run, n. 1. The act of running; as, a long run; a good run; a quick run; to go on the run. [1913 Webster] 2. A small stream; a brook; a creek. [1913 Webster] 3. That which runs or flows in the course of a certain operation, or during a certain … The Collaborative International Dictionary of English
The Run Home — The drivetime slot The Run Home is hosted by Francis Leach and David Schwarz. The theme music used is Coming Home by Alex Lloyd.Regular guests include journalist Mark Robinson, Gossip contributor Sergio Paradise, umpire Derek Humphrey Smith as… … Wikipedia
To let go by the run — Run Run, n. 1. The act of running; as, a long run; a good run; a quick run; to go on the run. [1913 Webster] 2. A small stream; a brook; a creek. [1913 Webster] 3. That which runs or flows in the course of a certain operation, or during a certain … The Collaborative International Dictionary of English
Against the run of play — The term against the run of play is used in football (soccer) to describe an event or action against the flow of the game. For example, if team A is having all of the possession, all of the chances and are dictating the game, yet team B have one… … Wikipedia
Band on the Run — For the title song from the album, see Band on the Run (song). Band on the Run Studio album by Paul McCartney & … Wikipedia
On the Run (convenience store) — An Esso branded service station, with On the Run convenience store, in Ottawa, Ontario, Canada. This location, owned by Imperial Oil, includes a Tim Hortons drive thru and an RBC bank machine. On the Run is a flagship convenience store brand… … Wikipedia
On the Run — may refer to: On the run , a phrase often used to describe a fugitive, a person fleeing custody Contents 1 Music 2 Literature 3 … Wikipedia
Reviews on the Run — (formerly known as Judgment Day in the United States) is a video game review TV show hosted by Victor Lucas and Tommy Tallarico, and produced by Lucas production company, Greedy Productions. The two hosts rate games independently on a scale of .5 … Wikipedia
Monty on the Run — Developer(s) Peter Harrap Publisher(s) Gremlin Graphics Distributor(s) … Wikipedia
On the Run (Jay Chou album) — Infobox Album Name = On The Run Type = album Longtype = Artist = Jay Chou Released = November 2, 2007 Recorded = Genre = C pop/Mandopop C rock R B Hip hop/Pop rap Length = 39:10 Label = JVR Music Producer = Reviews = Last album = Still Fantasy… … Wikipedia
Перевод: с русского на французский
с французского на русский- С французского на:
- Русский
- С русского на:
- Все языки
- Английский
- Итальянский
- Немецкий
- Персидский
- Французский