81 главная цепь коммутационного аппарата
главная цепь коммутационного аппарата
Все токоведущие части коммутационного аппарата, входящие в цепь, которую он предназначен замыкать или размыкать.
МЭК 60050(441-15-02).
[ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]
главная цепь аппарата
Токоведущие части аппарата, включенные в электрическую цепь, которую этот аппарат должен коммутировать в соответствии с его основным назначением.
[ ГОСТ 17703-72]
главная цепь
-
[IEV number 442-04-29]EN
main circuit (of a switching device)
all the conductive parts of a switching device included in the circuit which it is designed to close or open
[IEV number 441-15-02]
switching circuit
the circuit which contains the parts which allow the rated current to flow through the switching device
[IEV number 442-04-29]FR
circuit principal (d'un appareil de connexion)
ensemble de pièces conductrices d'un appareil de connexion insérées dans le circuit qu'il a pour fonction de fermer ou d'ouvrir
[IEV number 441-15-02]
circuit de l'interrupteur
circuit comportant les parties permettant le passage du courant assigné dans le dispositif de coupure
[IEV number 442-04-29]Тематики
- аппарат, изделие, устройство...
EN
DE
FR
Русско-французский словарь нормативно-технической терминологии > главная цепь коммутационного аппарата
-
82 переходная секция шинопровода
переходная секция шинопровода
Секция, предназначенная для соединения двух секций одной и той же системы, однако отличающихся по типу или с разными значениями номинального тока.
[ ГОСТ Р 51321. 2-2009EN
busbar trunking adapter unit
busbar trunking unit intended to connect two units of the same system but of different type or of different rated current
[IEC 60439-2, ed. 3.0 (2000-03)]FR
élément de canalisation préfabriquée d'adaptation
élément de canalisation préfabriquée destiné à raccorder deux éléments d'un même système, mais de types ou de courants assignés différents
[IEC 60439-2, ed. 3.0 (2000-03)]Тематики
- изделие электромонтажное
- электропроводка, электромонтаж
EN
FR
Русско-французский словарь нормативно-технической терминологии > переходная секция шинопровода
-
83 номинальный коэффициент трансформации трансформатора тока
номинальный коэффициент трансформации трансформатора тока
-EN
rated transformation ratio of a current transformer
the ratio of the rated primary current to the rated secondary current of a current transformer
[IEV number 321-01-19]FR
rapport de transformation assigné d'un transformateur de courant
rapport entre le courant primaire assigné et le courant secondaire assigné d'un transformateur de courant
[IEV number 321-01-19]Тематики
EN
DE
FR
Русско-английский словарь нормативно-технической терминологии > номинальный коэффициент трансформации трансформатора тока
-
84 номинальный ток термической стойкости
номинальный ток термической стойкости
Действующее (эффективное) значение тока, термическое действие которого должна выдерживать данная электроустановка в течение заданного времени без повреждений, нарушающих ее работоспособность.
[СТ СЭВ 2726-80]
номинальный токпотермической стойкости
—
[В.А.Семенов. Англо-русский словарь по релейной защите]Недопустимые, нерекомендуемые
Тематики
EN
Русско-английский словарь нормативно-технической терминологии > номинальный ток термической стойкости
-
85 номинальное напряжение ОПН
номинальное напряжение
Uн
Действующее значение напряжения промышленной частоты, которое ограничитель может выдерживать в течение 10 с в процессе рабочих испытаний. Номинальное напряжение должно быть не менее 1,25 наибольшего длительно допустимого рабочего напряжения.
[ ГОСТ Р 52725-2007]EN
rated voltage of an arrester
Ur
maximum permissible r.m.s. value of power-frequency voltage between its terminals at which it is designed to operate correctly under temporary overvoltage conditions as established in the operating duty tests
NOTE 1 The rated voltage is used as a reference parameter for the specification of operating characteristics.
NOTE 2 The rated voltage as defined in this standard is the 10 s power-frequency voltage used in the operating duty test after high-current or long-duration impulses. Tests used to establish the voltage rating in IEC 60099-1, as well as some national standards, involve the application of repetitive impulses at nominal current with power-frequency voltage applied. Attention is drawn to the fact that these two methods used to established rating do not necessarily produce equivalent values (a resolution to this discrepancy is under consideration).
[IEC 60099-4, ed. 2.0 (2004-05)]FR
tension assignée d'un parafoudre
Ur
valeur maximale de la tension efficace à fréquence industrielle admissible entre ses bornes pour laquelle le parafoudre est prévu pour fonctionner correctement dans des conditions de surtension temporaires comme il est défini dans les essais de fonctionnement
NOTE 1 La tension assignée est utilisée comme paramètre de référence pour la spécification des caractéristiques de fonctionnement.
NOTE 2 La tension assignée comme définie dans la présente norme est la tension à fréquence industrielle de 10 s, utilisée pour vérifier la stabilité après application des chocs de courant de grande amplitude ou de longue durée lors de l'essai de fonctionnement. Les essais utilisés pour définir la tension assignée dans la CEI 60099-1, ainsi que dans certaines normes nationales, impliquent l'application de chocs répétés au courant nominal pendant que la tension à fréquence industrielle est appliquée. On attire l'attention sur le fait que ces deux méthodes utilisées pour définir les valeurs assignées ne produisent pas nécessairement des valeurs équivalentes (une résolution de cette différence est à l'étude).
[IEC 60099-4, ed. 2.0 (2004-05)]Тематики
- высоковольтный аппарат, оборудование...
EN
FR
Русско-английский словарь нормативно-технической терминологии > номинальное напряжение ОПН
-
86 номинальный дифференциальный рабочий ток
номинальный
остаточныйдифференциальный рабочий ток
IΔn
Аварийный ток, на который рассчитано защитное устройство, управляемоеостаточнымдифференциальным током.
[ ГОСТ Р 61557-1-2006]EN
rated residual operating current
IΔN
value of residual current assigned by the manufacturer which causes the RCM to operate under specified conditions
[IEC 61557-11, ed. 1.0 (2009-01)]FR
courant assigné différentiel résiduel de fonctionnement
IΔN
valeur du courant différentiel résiduel fixée par le constructeur qui doit faire fonctionner le RCM dans des conditions spécifiées
[IEC 61557-11, ed. 1.0 (2009-01)]Тематики
EN
FR
Русско-английский словарь нормативно-технической терминологии > номинальный дифференциальный рабочий ток
-
87 испытательное сопротивление
испытательное сопротивление
Rp
Сопротивление, с помощью которого имитируется аварийный ток при проведении испытаний.
[ ГОСТ Р 61557-1-2006]Тематики
EN
3.6.4 испытательное сопротивление (rated residual operating current) Rp: Сопротивление, с помощью которого имитируется аварийный ток при проведении испытаний.
Источник: ГОСТ Р МЭК 61557-1-2005: Сети электрические распределительные низковольтные напряжением до 1000 В переменного тока и 1500 В постоянного тока. Электробезопасность. Аппаратура для испытания, измерения или контроля средств защиты. Часть 1. Общие требования оригинал документа
Русско-английский словарь нормативно-технической терминологии > испытательное сопротивление
-
88 номинальный остаточный рабочий ток
номинальный остаточный рабочий ток
IΔn
Аварийный ток, на который рассчитано защитное устройство, управляемое остаточным током.
[ ГОСТ Р 61557-1-2006]Тематики
EN
3.6.2 номинальный остаточный рабочий ток (rated residual operating current) IΔn: Аварийный ток, на который рассчитано защитное устройство, управляемое остаточным током.
Источник: ГОСТ Р МЭК 61557-1-2005: Сети электрические распределительные низковольтные напряжением до 1000 В переменного тока и 1500 В постоянного тока. Электробезопасность. Аппаратура для испытания, измерения или контроля средств защиты. Часть 1. Общие требования оригинал документа
Русско-английский словарь нормативно-технической терминологии > номинальный остаточный рабочий ток
-
89 номинальный ток управления магнитного усилителя
номинальный ток управления магнитного усилителя
Ток управления магнитного усилителя, необходимый для создания номинального перепада выходной величины, установленного для данного вида магнитных усилителей, при номинальных значениях напряжения и частоты напряжения питания, напряжения нагрузки магнитного усилителя.
[ ГОСТ 17561-84]Тематики
EN
40. Номинальный ток управления магнитного усилителя
Rated control current of transductor
Ток управления магнитного усилителя, необходимый для создания номинального перепада выходной величины, установленного для данного вида магнитных усилителей, при номинальных значениях напряжения и частоты напряжения питания, напряжения нагрузки магнитного усилителя
Источник: ГОСТ 17561-84: Усилители магнитные. Термины и определения оригинал документа
Русско-английский словарь нормативно-технической терминологии > номинальный ток управления магнитного усилителя
-
90 длительный допустимый ток
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Русско-английский словарь нормативно-технической терминологии > длительный допустимый ток
-
91 включаемый номинальный ток короткого замыкания
Русско-английский словарь нормативно-технической терминологии > включаемый номинальный ток короткого замыкания
-
92 допустимый ток по скорости нагрева
допустимый ток по скорости нагрева
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
Русско-английский словарь нормативно-технической терминологии > допустимый ток по скорости нагрева
-
93 максимально допустимый ток (св.)
максимально допустимый ток (св.)
—
[ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > максимально допустимый ток (св.)
-
94 номинальная длительность прохождения кратковременно выдерживаемого тока
Русско-английский словарь нормативно-технической терминологии > номинальная длительность прохождения кратковременно выдерживаемого тока
-
95 номинально допустимый ток (св.)
номинально допустимый ток (св.)
—
[ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > номинально допустимый ток (св.)
-
96 номинальный вторичный ток (трансформатора)
номинальный вторичный ток (трансформатора)
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999]Тематики
- электротехника, основные понятия
EN
Русско-английский словарь нормативно-технической терминологии > номинальный вторичный ток (трансформатора)
-
97 номинальный динамический ток
номинальный динамический ток
Амплитудное значение тока, динамическое воздействие которого электрооборудование может выдержать без повреждения.
Обозначение
символ Idyn
[ ГОСТ Р МЭК 60050-426-2006]
Тематики
EN
Русско-английский словарь нормативно-технической терминологии > номинальный динамический ток
-
98 номинальный кратковременно выдерживаемый ток, Icw
номинальный кратковременно выдерживаемый ток
Icw
Это значение кратковременно выдерживаемого тока, установленное для выключателя изготовителем в условиях испытаний по 8.3.6.2.
Для переменного тока — это действующее значение периодической составляющей ожидаемого тока короткого замыкания, который рассматривают как неизменный на протяжении определенного короткого времени.
Длительность прохождения Icw должна составлять по крайней мере 0,05 с. Предпочтительные значения: 0,05; 0,1; 0,25; 0,5; 1 с.
Номинальный кратковременно выдерживаемый ток должен быть не- ниже указанного в таблице 3.
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
кратковременный выдерживаемый ток (ток термической стойкости)
Iт
Ток, который выключатель должен пропускать во включенном положении в течение нормированного короткого промежутка времени при предписанных условиях применения и поведения
[ ГОСТ Р 52565-2006]
номинальный кратковременный выдерживаемый ток (ток термической стойкости) IT, кА
Ток, который цепь или коммутационный аппарат может выдержать во включенном положении в течение нормированного короткого промежутка времени при предписанных условиях применения и поведения.
[ ГОСТ Р 52726-2007]
номинальный кратковременный выдерживаемый выключателем ток является максимальным током (выраженным в кА), который должен выдерживать выключатель в положении с замкнутыми контактами на протяжении заданного времени. Номинальный кратковременный выдерживаемый ток равен номинальному току короткого замыкания при отключении. Стандартные значения промежутка времени равны 1 или 3 с.
[http://forca.ru/info/spravka/nominalnyi-kratkovremennyi-vyderzhivaemyi-vyklyuchatelem-tok.html]Тематики
- выключатель автоматический
- выключатель, переключатель
- высоковольтный аппарат, оборудование...
Синонимы
- кратковременный выдерживаемый ток
- номинальный кратковременный выдерживаемый выключателем ток
- ток термической стойкости
EN
Русско-английский словарь нормативно-технической терминологии > номинальный кратковременно выдерживаемый ток, Icw
-
99 номинальный сварочный ток (св.)
номинальный сварочный ток (св.)
—
[ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > номинальный сварочный ток (св.)
-
100 номинальный термический ток короткого замыкания
номинальный термический ток короткого замыкания
Действующее значение тока, требуемого для нагрева проводника от номинальной рабочей температуры до предельной температуры за 1 с при максимальном значении температуры окружающей среды.
Обозначение
символ Ith
[ ГОСТ Р МЭК 60050-426-2006]
Тематики
EN
Русско-английский словарь нормативно-технической терминологии > номинальный термический ток короткого замыкания
См. также в других словарях:
rated current — vardinė srovė statusas T sritis automatika atitikmenys: angl. current rating; nominal current; rated current vok. Nennstrom, m rus. номинальный ток, m pranc. courant assigné, m; courant de consigne, m; courant nominal, m ryšiai: sinonimas –… … Automatikos terminų žodynas
rated current — vardinė srovė statusas T sritis fizika atitikmenys: angl. nominal current; rated current vok. Nennstrom, m rus. номинальный ток, m pranc. courant assigné, m; courant nominal, m … Fizikos terminų žodynas
rated current — vardinė srovė statusas T sritis Standartizacija ir metrologija apibrėžtis Srovės stipris, pagal kurį nustatomos kai kurios transformatorinio skaitiklio charakteristikos. atitikmenys: angl. rated current vok. Nennstrom, m rus. номинальный ток, m… … Penkiakalbis aiškinamasis metrologijos terminų žodynas
Current transformer — A CT for operation on a 110 kV grid In electrical engineering, a current transformer (CT) is used for measurement of electric currents. Current transformers, together with voltage transformers (VT) (potential transformers (PT)), are known as … Wikipedia
current rating — vardinė srovė statusas T sritis automatika atitikmenys: angl. current rating; nominal current; rated current vok. Nennstrom, m rus. номинальный ток, m pranc. courant assigné, m; courant de consigne, m; courant nominal, m ryšiai: sinonimas –… … Automatikos terminų žodynas
Rated R (Rihanna album) — Rated R Studio album by Rihanna Released November 20, 2009 ( … Wikipedia
Current limiting — is the practice in electrical or electronic circuits of imposing an upper limit on the current that may be delivered to a load with the purpose of protecting the circuit generating or transmitting the current from harmful effects due to a short… … Wikipedia
Current source — Figure 1: An ideal current source, I, driving a resistor, R, and creating a voltage V A current source is an electrical or electronic device that delivers or absorbs electric current. A current source is the dual of a voltage source. The term… … Wikipedia