Перевод: с русского на французский

с французского на русский

heat+of+melting

  • 1 длительный допустимый ток

    1. courant permanent admissible, m
    2. courant admissible, m

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-французский словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • Melting — Melt ing a. Causing to melt; becoming melted; used literally or figuratively; as, a melting heat; a melting appeal; a melting mood. {Melt ing*ly}, adv. [1913 Webster] …   The Collaborative International Dictionary of English

  • Melting point depression — is a term referring to the phenomenon of reduction of the melting point of a material with reduction of its size. This phenomenon is very prominent in nanoscale materials which melt at temperatures hundreds of degrees lower than bulk… …   Wikipedia

  • Heat-shrink tubing — (or commonly heat shrink ) is a tube which shrinks in diameter when heated. Its diameter and thickness can vary, and there are three main categories, thin wall, medium wall and thick wall tube. Heat shrink is used to insulate wires, connections,… …   Wikipedia

  • Heat-shrinkable sleeve — (or commonly shrink sleeve ) is a corrosion protective coating for pipelines in the form of a wraparound or tubular sleeve that is field applied. History The first heat shrinkable sleeves were introduced over 35 years ago when polyethylene… …   Wikipedia

  • melting point — melting points N COUNT: oft with poss The melting point of a substance is the temperature at which it melts when you heat it …   English dictionary

  • heat of fusion — n. the amount of heat needed to melt a unit mass of a solid that has just reached the melting point …   English World dictionary

  • Melting point — For the physical processes that takes place at the melting point, see Melting, Freezing and Crystallization The melting point of a solid is the temperature at which it changes state from solid to liquid. At the melting point the solid and liquid… …   Wikipedia

  • Melting tank — A melting tank is a tank used by manufacturing companies to manufacture a variety of products. Contents 1 Melting tank uses 2 Different types of tanks 2.1 Heating variations 3 …   Wikipedia

  • melting point — Physical Chem. the temperature at which a solid substance melts or fuses. [1835 45] * * * Temperature at which the solid and liquid states of a pure substance can exist in equilibrium. As heat is applied to a solid, its temperature increases… …   Universalium

  • Melting-point depression — This article deals with melting/freezing point depression due to very small particle size. For depression due to the mixture of another compound, see freezing point depression. Melting point depression is a term referring to the phenomenon of… …   Wikipedia

  • Melting — Ice melting Molten redirects here. For the Japanese company, see Molten Corporation; or see Molton or Moulton. Melting, or fusion, is a physical process that results in the phase change of a substance from a solid to a liquid. The internal energy …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»