101 circuit breaker
автоматический выключатель
Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
(МЭС 441-14-20)
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
автоматический выключатель
-
[IEV number 442-05-01]EN
circuit breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
circuit breaker
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
[National Electrical Cod]FR
disjoncteur
1) Должно быть контактный коммутационный аппарат
appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
[Интент]КЛАССИФИКАЦИЯ
- По роду тока
- По напряжению
- По числу полюсов
- По виду корпуса
- По месту установки
- По изолирующей среде
- По установленным расцепителям
- По дополнительным защитам
- По назначению
- По категории применения
- По виду привода взвода пружины
- По выполняемой функции
-
По влиянию монтажного положения
Автоматические выключатели ABB Модульные автоматические выключатели
1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).
[Интент]Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
[Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Электромагнитный расцепитель;
5 - Сердечник
6 - Катушка
7 - Контактные зажимы автоматического выключателя
На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).
Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Тепловой расцепитель
5 - Биметаллическая пластина
6 - Нагревательный элемент
7 - Контактные зажимы автоматического выключателя
[Интент]Недопустимые, нерекомендуемые
Тематики
Классификация
>>>Обобщающие термины
Действия
- включение автоматического выключателя
- оперирование автоматического выключателя
- отключение автоматического выключателя
- срабатывание автоматического выключателя
EN
- auto-cutout
- automatic circuit breaker
- automatic cutout
- automatic switch
- breaker
- CB
- circuit breaker
- circuit-breaker
- cutout
DE
FR
Смотри также
выключатель
Коммутационный электрический аппарат, имеющий два коммутационных положения или состояния и предназначенный для включении и отключения тока.
Примечание. Под выключателем обычно понимают контактный аппарат без самовозврата. В остальных случаях термин должен быть дополнен поясняющими словами, например, «выключатель с самовозвратом», «выключатель тиристорный» и т. д.
[ ГОСТ 17703-72]
выключатель
Контактный коммутационный аппарат, способный включать, проводить и отключать токи при нормальных условиях в цепи, а также включать, проводить в течение нормированного времени и отключать токи при нормированных анормальных условиях в цепи, таких как короткое замыкание.
[ ГОСТ Р 52565-2006]
выключатель
Устройство для включения и отключения тока и напряжения в одной или более электрических цепях.
Примечание. При отсутствии других указаний под понятиями «напряжение» и «ток» подразумевают их среднеквадратичные значения.
[ ГОСТ Р 51324.1-2005]
выключатель
Прибор для включения и отключения электрического оборудования и устройств
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]EN
(on-off) switch
switch for alternatively closing and opening one or more electric circuits
Source: 581-10-01 MOD
[IEV number 151-12-23]FR
interrupteur, m
commutateur destiné à fermer et ouvrir alternativement un ou plusieurs circuits électriques
Source: 581-10-01 MOD
[IEV number 151-12-23]При отключении воздушных и кабельных линий тупикового питания первым рекомендуется отключать выключатель со стороны нагрузки, вторым — со стороны питания.
[РД 153-34.0-20.505-2001]
... так чтобы она с меньшей выдержкой времени отключала выключатели с той стороны, на которой защита отсутствует;
[ПУЭ]
б) блокировка между выключателями нагрузки или разъединителем и заземляющим разъединителем, не позволяющая включать выключатель нагрузки или разъединитель при включенном заземляющем разъединителе и включать заземляющий разъединитель при включенном выключателе нагрузки или разъединителе;
[ ГОСТ 12.2.007.4-75]
Испытания изоляции выключателей и разъединителей должны быть проведены при включенном и отключенном положениях.
[ ГОСТ 1516_1-76]
Выключатели предназначены для оперативной и аварийной коммутации в энергосистемах, т.е. выполнения операций включения и отключения отдельных цепей при ручном или автоматическом управлении. Во включенном состоянии выключатели должны беспрепятственно пропускать токи нагрузки. Характер режима работы этих аппаратов несколько необычен: нормальным для них считается как включенное состояние, когда они обтекаются током нагрузки, так и отключенное, при котором они обеспечивают необходимую электрическую изоляцию между разомкнутыми участками цепи. Коммутация цепи, осуществляемая при переключении выключателя из одного положения в другое, производится нерегулярно, время от времени, а выполнение им специфических требований по отключению возникающего в цепи короткого замыкания чрезвычайно редко. Выключатели должны надежно выполнять свои функции в течение срока службы, находясь в любом из указанных состояний, и одновременно быть всегда готовыми к мгновенному эффективному выполнению любых коммутационных операций, часто после длительного пребывания в неподвижном состоянии. Отсюда следует, что они должны иметь очень высокий коэффициент готовности: при малой продолжительности процессов коммутации (несколько минут в год) должна быть обеспечена постоянная готовность к осуществлению коммутаций.
[ http://relay-protection.ru/content/view/46/8/]Тематики
- выключатель, переключатель
- релейная защита
Действия
Сопутствующие термины
EN
DE
FR
прерыватель цепи
(МСЭ-Т K.66).
[ http://www.iks-media.ru/glossary/index.html?glossid=2400324]Тематики
- электросвязь, основные понятия
EN
рубильник
Выключатель ручного действия с ножеобразными подвижными контактами, входящими в неподвижные пружинящие зажимы-гнёзда
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]Тематики
- выключатель, переключатель
EN
- bladed switch
- bladed-type switch
- circuit breaker
- cutout
- cutout knife switch
- knife switch
- knife-blade switch
- knife-break switch
- lever switch
DE
FR
Англо-русский словарь нормативно-технической терминологии > circuit breaker
102 circuit-breaker
автоматический выключатель
Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
(МЭС 441-14-20)
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
автоматический выключатель
-
[IEV number 442-05-01]EN
circuit breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
circuit breaker
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
[National Electrical Cod]FR
disjoncteur
1) Должно быть контактный коммутационный аппарат
appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
[Интент]КЛАССИФИКАЦИЯ
- По роду тока
- По напряжению
- По числу полюсов
- По виду корпуса
- По месту установки
- По изолирующей среде
- По установленным расцепителям
- По дополнительным защитам
- По назначению
- По категории применения
- По виду привода взвода пружины
- По выполняемой функции
-
По влиянию монтажного положения
Автоматические выключатели ABB Модульные автоматические выключатели
1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).
[Интент]Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
[Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Электромагнитный расцепитель;
5 - Сердечник
6 - Катушка
7 - Контактные зажимы автоматического выключателя
На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).
Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Тепловой расцепитель
5 - Биметаллическая пластина
6 - Нагревательный элемент
7 - Контактные зажимы автоматического выключателя
[Интент]Недопустимые, нерекомендуемые
Тематики
Классификация
>>>Обобщающие термины
Действия
- включение автоматического выключателя
- оперирование автоматического выключателя
- отключение автоматического выключателя
- срабатывание автоматического выключателя
EN
- auto-cutout
- automatic circuit breaker
- automatic cutout
- automatic switch
- breaker
- CB
- circuit breaker
- circuit-breaker
- cutout
DE
FR
Смотри также
силовой выключатель
-
[Интент]EN
circuit-breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit
[IEV ref 441-14-20]FR
disjoncteur
appareil mécanique de connexion capable d'établir, de supporter et d'interrompre des courants dans les conditions normales du circuit, ainsi que d'établir, de supporter pendant une durée spécifiée et d'interrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit
[IEV ref 441-14-20]
Рис. Siemens
Силовой ( баковый элегазовый) выключатель 3AP1 DT
Рис. Siemens
Силовой (колонковый элегазовый) выключательТематики
- высоковольтный аппарат, оборудование...
- комплектное распред. устройство (КРУ)
EN
DE
FR
2.1 выключатель (circuit-breaker): Контактный коммутационный аппарат, способный включать, проводить и отключать токи при нормальных условиях цепи, а также включать, проводить в течение нормированного времени и отключать токи при нормированных ненормальных условиях в цепи, таких, как короткое замыкание.
[МЭС 441-14-20] [1]
Источник: ГОСТ Р 50030.2-2010: Аппаратура распределения и управления низковольтная. Часть 2. Автоматические выключатели оригинал документа
3.3.4 автоматический выключатель (circuit-breaker): Контактный коммутационный аппарат, способный включать, проводить и отключать токи при нормальных условиях в цепи, а также включать, проводить в течение установленного времени и отключать (автоматически) при указанных аномальных условиях в цепи, таких, как короткое замыкание.
[МЭС 441-14-20] [1]
Источник: ГОСТ Р 51327.1-2010: Выключатели автоматические, управляемые дифференциальным током, бытового и аналогичного назначения со встроенной защитой от сверхтоков. Часть 1. Общие требования и методы испытаний оригинал документа
3.2.5 автоматический выключатель (circuit-breaker): Контактный коммутационный аппарат, способный включать, проводить и отключать токи при нормальных условиях в цепи, а также включать, проводить в течение установленного нормированного времени и отключать токи при указанных ненормальных условиях в цепи, таких как короткое замыкание.
[МЭК 60050(441-14-20)]
Источник: ГОСТ Р 51731-2010: Контакторы электромеханические бытового и аналогичного назначения оригинал документа
Англо-русский словарь нормативно-технической терминологии > circuit-breaker
103 delay device
устройство выдержки времени
-
[IEV number 442-04-34]EN
delay device
device consisting of all components which have an influence on the delay time
NOTE 1 – The delay device is energized by means of a pulse into the control circuit in an electrically controlled time-delay switch.
NOTE 2 – The delay time can be adjustable.
[IEV number 442-04-34]FR
dispositif de temporisation
dispositif composé de l'ensemble des constituants qui influencent la temporisation
NOTE 1 – Dans les interrupteurs temporisés à commande électrique, le dispositif de temporisation est excité par une impulsion du circuit de commande.
NOTE 2 – La temporisation peut être réglable.
[IEV number 442-04-34]Тематики
EN
DE
FR
устройство задержки
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > delay device
104 delay multivibrator
моностабильный элемент
одновибратор
-
[ГОСТ 2.743-91]Одновибраторы -"ждущие мультивибраторы" представляют собой микросхемы, которые в ответ на входной сигнал (логический уровень или фронт) формируют выходной импульс заданной длительности.
Длительность определяется внешними времязадающими резисторами и конденсаторами.
То есть можно считать, что у одновибраторов есть внутренняя память, но эта память хранит информацию о входном сигнале строго заданное время, а потом информация исчезает.
В стандартные серии микросхем входят одновибраторы двух основных типов:
- одновибраторы без перезапуска;
- одновибраторы с перезапуском
Одновибратор без перезапуска не реагирует на входной сигнал до окончания своего выходного импульса.
Одновибратор с перезапуском начинает отсчет нового времени выдержки Т с каждым новым входным сигналом независимо от того, закончилось ли предыдущее время выдержки.
В случае, когда период следования входных сигналов меньше времени выдержки Т, выходной импульс одновибратора сперезапуском не прерывается.
Если период следования входных запускающих импульсов больше времени выдержки одновибратора Т, то оба типа одновибраторов работают одинаково.
Одновибратор без перезапуска
Одновибратор с перезапуском
[Ю.В. Новиков. Введение в цифровую схемотехнику]
Параллельные тексты EN-RU
Monostable flip-flop
The output variable will be 1 only if the input variable changes to 1.
The output variable will remain 1 for 100 ms, regardless of the duration of the input value 1 (non-retriggerable).
Without a 1 in the function block, the monostable flip-flop is retriggerable.
The time is 100 ms in this example, but it may be changed to any other duration.
[Schneider Electric]Одновибратор
Значение переменной на выходе равно 1, если входная переменная становится равной 1.
Выходная переменная сохраняет значение 1 в течение 100 мс независимо от времени, в течение которого входная переменная продолжает оставаться равной 1 (без выполнения повторного запуска элемента).
Если в обозначении функции элемента не стоит "1", то это одновибратор с перезапуском.
В данном примере время выходного импульса составляет 100 мс, но его можно изменить на любое другое.
[Перевод Интент]Тематики
- Булева алгебра, элементы цифровой техники
Синонимы
EN
- biased multivibrator
- delay multivibrator
- gate multivibrator
- gated multivibrator
- kipp oscillator
- kipp relay
- latching circuit
- mono
- monoflop
- monostable
- monostable circuit
- monostable flip-flop
- monostable multivibrator
- monostable trigger circuit
- monovibrator
- one-cycle multivibrator
- one-shot
- one-shot generator
- one-shot multivibrator
- single flip-flop oscillator
- single vibrator
- single-shot flip-flop
- single-shot multivibrator
- single-shot trigger
- single-shot trigger circuit
- single-trip multivibrator
- single-trip trigger
- single-trip trigger circuit
- start-stop multivibrator
- trigger circuit
- univibrator
Англо-русский словарь нормативно-технической терминологии > delay multivibrator
105 delay time (of a time-delay switch)
выдержка времени (для выключателя с выдержкой времени)
-
[IEV number 442-04-32]EN
delay time (of a time-delay switch)
the period during which the switching circuit(s) is (are) kept closed
NOTE – Any time taken for the decreasing of the voltage (e.g. to reduce the light) at the end of the delay period is included within the delay time.
[IEV number 442-04-32]FR
temporisation (d'un interrupteur temporisé)
intervalle de temps pendant lequel le ou les circuits de l'interrupteur restent fermés
NOTE – L'intervalle au cours duquel la tension diminue (par exemple pour réduire la lumière) à la fin du temps de temporisation est compris dans la temporisation.
[IEV number 442-04-32]Тематики
- выключатель, переключатель
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > delay time (of a time-delay switch)
106 delay cable
The English-Russian dictionary general scientific > delay cable
107 delay flip-flop
триггер с задержкой; ждущий мультивибраторflip-flop circuit — триггер; триггерная схема
108 delay relay circuit
Железнодорожный термин: цепь реле задержки109 delay-insensitive circuit
схема, не чувствительная к задержке ( сигнала)The New English-Russian Dictionary of Radio-electronics > delay-insensitive circuit
110 delay-sensitive circuit
схема, чувствительная к задержке ( сигнала)The New English-Russian Dictionary of Radio-electronics > delay-sensitive circuit
111 delay relay circuit
112 circuit delay
nELECTRON circuito de retardo m, temporizador de circuito m113 time base circuit
The English-Russian dictionary general scientific > time base circuit
114 phase-lag circuit
фазозадерживающая схема
фазозадерживающая цепь
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
Синонимы
EN
Англо-русский словарь нормативно-технической терминологии > phase-lag circuit
115 short-time delay short-circuit release
- расцепитель токов короткого замыкания с кратковременной выдержкой
- расцепитель тока короткого замыкания с кратковременной выдержкой времени
расцепитель токов короткого замыкания с кратковременной выдержкой времени
Расцепитель токов короткого замыкания, предназначенный для срабатывания по истечении кратковременной выдержки времени (см. 2.5.26 МЭК 60947-1).
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]EN
short-time delay short-circuit release
an over-current release intended to operate at the end of the short-time delay (see 2.5.26 of IEC 60947-1)
[< size="2">IEC 60947-2, ed. 4.0 (2006-05)]FR
déclencheur de court-circuit à retard de courte durée
déclencheur de court-circuit destiné à fonctionner à la fin du retard de courte durée (voir 2.5.26 de la CEI 60947-1)
[< size="2">IEC 60947-2, ed. 4.0 (2006-05)]Тематики
- выключатель автоматический
- расцепитель, тепловое реле
Классификация
>>>EN
FR
2.12 расцепитель токов короткого замыкания с кратковременной выдержкой (short-time delay short-circuit release): Расцепитель токов короткого замыкания, предназначенный для срабатывания по истечении кратковременной выдержки ( см. 2.5.26 ГОСТ Р 50030.1).
Источник: ГОСТ Р 50030.2-2010: Аппаратура распределения и управления низковольтная. Часть 2. Автоматические выключатели оригинал документа
Англо-русский словарь нормативно-технической терминологии > short-time delay short-circuit release
116 automatic circuit breaker
автоматический выключатель
Механический коммутационный аппарат1), способный включать, проводить и отключать токи при нормальном состоянии электрической цепи, а также включать, проводить в течение заданного времени и автоматически отключать токи в указанном аномальном состоянии электрической цепи, например, при коротком замыкании.
(МЭС 441-14-20)
[ ГОСТ Р 50030. 2-99 ( МЭК 60947-2-98)]
автоматический выключатель
-
[IEV number 442-05-01]EN
circuit breaker
a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
circuit breaker
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
NOTE The automatic opening means can be integral, direct acting with the circuit breaker, or remote from the circuit breaker.
Adjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker can be set to trip at various values of current, time, or both within a predetermined range. Instantaneous-trip (as applied to circuit breakers). A qualifying term indicating that no delay is purposely introduced in the tripping action of the circuit breaker.
Inverse-time (as applied to circuit breakers). A qualifying term indicating a delay is purposely introduced in the tripping action of the circuit breaker, which delay decreases as the magnitude of the current increases.
Nonadjustable (as applied to circuit breakers). A qualifying term indicating that the circuit breaker does not have any adjustment to alter the value of current at which it will trip or the time required for its operation.
Setting (of a circuit breaker). The value of current, time, or both at which an adjustable circuit breaker is set to trip.
[National Electrical Cod]FR
disjoncteur
1) Должно быть контактный коммутационный аппарат
appareil mécanique de connexion capable d’établir, de supporter et d’interrompre des courants dans les conditions normales du circuit, ainsi que d’établir, de supporter pendant une durée spécifiée et d’in- terrompre des courants dans des conditions anormales spécifiées du circuit telles que celles du court-circuit.
[IEC 62271-100, ed. 2.0 (2008-04)]
[IEV number 442-05-01]
[Интент]КЛАССИФИКАЦИЯ
- По роду тока
- По напряжению
- По числу полюсов
- По виду корпуса
- По месту установки
- По изолирующей среде
- По установленным расцепителям
- По дополнительным защитам
- По назначению
- По категории применения
- По виду привода взвода пружины
- По выполняемой функции
-
По влиянию монтажного положения
Автоматические выключатели ABB Модульные автоматические выключатели
1. НЕКОТОРЫЕ СВЕДЕНИЯ ОБ АВТОМАТИЧЕСКИХ ВЫКЛЮЧАТЕЛЯХ Автоматический выключатель — это электрический аппарат, который автоматически отключает (и тем самым защищает) электрическую цепь при возникновении в ней аномального режима. Режим становится аномальным, когда в цепи начинает недопустимо изменяться (т. е. увеличиваться или уменьшаться относительно номинального значения) ток или напряжение.
Другими словами (более "инженерно") можно сказать, что автоматический выключатель защищает от токов короткого замыкания и токов перегрузки отходящую от него питающую линию, например, кабель и приемник(и) электрической энергии (осветительную сеть, розетки, электродвигатель и т. п.).
Как правило, автоматический выключатель может применятся также для нечастого (несколько раз в сутки) включения и отключения защищаемых электроприемников (защищаемой нагрузки).
[Интент]Выключатель предназначен для проведения тока в нормальном режиме и отключения тока при коротких замыканиях, перегрузках, недопустимых снижениях напряжения, а также до 30 оперативных включений и отключений электрических цепей в сутки и рассчитан для эксплуатации в электроустановках с номинальным рабочим напряжением до 660 В переменного тока частоты 50 и 60 Гц и до 440 В постоянного тока.
[Типовая фраза из российской технической документации] 2. ПРИНЦИП ДЕЙСТВИЯ Для защиты цепи от короткого замыкания применяется автоматический выключатель с электромагнитным расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Автоматический выключатель устроен таким образом, что сначала необходимо взвести пружину и только после этого его можно включить. У многих автоматических выключателей для взвода пружины необходимо перевести ручку вниз. После этого ручку переводят вверх. При этом замыкаются главные контакты.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Электромагнитный расцепитель;
5 - Сердечник
6 - Катушка
7 - Контактные зажимы автоматического выключателя
На рисунке показан один полюс автоматического выключателя во включенном положении: пружина 1 взведена, а главный контакт 2 замкнут.
Как только в защищаемой цепи возникнет короткое замыкание, ток, протекающий через соответствующий полюс автоматического выключателя, многократно возрастет. В катушке 6 сразу же возникнет сильное магнитное поле. Сердечник 5 втянется в катушку и освободит удерживающее устройство. Под действием пружины 1 главный контакт 2 разомкнется, в результате чего автоматический выключатель отключит и тем самым защитит цепь, в которой возникло короткое замыкание. Такое срабатывание автоматического выключателя происходит практически мгновенно (за сотые доли секунды).
Для защиты цепи от тока перегрузки применяют автоматические выключатели с тепловым расцепителем.1 - Пружина (в данном случае во взведенном положении растянута)
Принцип действия такой же как и в первом случае, с той лишь разницей, что удерживающее устройство 3 освобождается под действием биметаллической пластины 5, которая изгибается от тепла, выделяемого нагревательным элементом 6. Количество тепла определяется током, протекающим через защищаемую цепь.
2 - Главный контакт автоматического выключателя
3 - Удерживающее устройство
4 - Тепловой расцепитель
5 - Биметаллическая пластина
6 - Нагревательный элемент
7 - Контактные зажимы автоматического выключателя
[Интент]Недопустимые, нерекомендуемые
Тематики
Классификация
>>>Обобщающие термины
Действия
- включение автоматического выключателя
- оперирование автоматического выключателя
- отключение автоматического выключателя
- срабатывание автоматического выключателя
EN
- auto-cutout
- automatic circuit breaker
- automatic cutout
- automatic switch
- breaker
- CB
- circuit breaker
- circuit-breaker
- cutout
DE
FR
Смотри также
Англо-русский словарь нормативно-технической терминологии > automatic circuit breaker
117 time-delay switch
- электрическое реле времени
- реле времени
- переключатель с выдержкой времени
- выключатель с выдержкой времени
- аппарат с выдержкой времени
аппарат с выдержкой времени
Коммутационный электрический аппарат, имеющий устройство, обеспечивающее специально предусмотренную выдержку времени от момента подачи команды на выполнение коммутационной операции до начала ее выполнения.
[ ГОСТ 17703-72]EN
time-delay switch
TDS
switch provided with a time-delay device which operates for a certain time (the delay time). It may be either manually actuated and/or remotely electrically initiated
[IEC 60669-2-3, ed. 3.0 (2006-08)]
time-delay switch
TDS
a switch provided with a time-delay device, which operates for a certain time (the delay time) and which is operated by hand and/or by remote control by means of pulses
[IEV number 442-04-33]
mechanical time-delay device
device which, through a mechanical auxiliary, operates some time after the instant at which the conditions which cause it to operate are established
NOTE - This definition is only applicable to the switching circuit.
[IEC 60669-2-3, ed. 3.0 (2006-08)]FR
interrupteurs temporisés (minuteries)
interrupteur pourvu d’un dispositif de temporisation qui le fait fonctionner pendant un certain temps (la temporisation). Il peut être commandé manuellement et/ou lancé électriquement à distance
[IEC 60669-2-3, ed. 3.0 (2006-08)]
interrupteur temporisé
interrupteur pourvu d'un dispositif de temporisation qui le fait fonctionner pendant un certain temps (la temporisation) et qui est commandé manuellement et/ou à distance au moyen d'impulsions
[IEV number 442-04-33]
dispositif mécanique à action différée
dispositif qui, par l'effet d'un auxiliaire mécanique, fonctionne un certain temps après l'instant où les conditions prévues pour son fonctionnement sont réalisées
NOTE - Cette définition s’applique seulement au circuit de l’interrupteur.
[IEC 60669-2-3, ed. 3.0 (2006-08)]Тематики
- аппарат, изделие, устройство...
EN
DE
FR
выключатель с выдержкой времени (таймер)
Выключатель, имеющий устройство выдержки времени, которое приводит его в действие на определенное время, по истечении которого автоматически разрывается цепь выключателя, и управляемый вручную и/или дистанционно импульсным методом.
[ ГОСТ Р 51324.2.3-99 (МЭК 60669-2-3-97)]
выключатель с выдержкой времени
-
[IEV number 442-04-33]EN
ime-delay switch
TDS (abbreviation)
a switch provided with a time-delay device, which operates for a certain time (the delay time) and which is operated by hand and/or by remote control by means of pulses
[IEV number 442-04-33]FR
interrupteur temporisé
interrupteur pourvu d'un dispositif de temporisation qui le fait fonctionner pendant un certain temps (la temporisation) et qui est commandé manuellement et/ou à distance au moyen d'impulsions
[IEV number 442-04-33]Тематики
- выключатель, переключатель
EN
DE
FR
переключатель с выдержкой времени
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
реле времени
Управляющее устройство с отсчетом времени, которое начинает следующий цикл после завершения предыдущего.
Примечание - Пример такого устройства - 24-часовое устройство управления аккумуляционным обогревателем.
[ГОСТ IЕС 60730-1-2011]Тематики
EN
электрическое реле времени
Логическое электрическое реле с нормируемой выдержкой времени
[ ГОСТ 16022-83]EN
time relay
specified-time relay (deprecated)
all-or-nothing relay with one or more specified time functions
[IEV number 445-01-01]FR
relais à temps spécifié, m
relais de tout ou rien comportant une ou plusieurs fonctions temporelles spécifiées
[IEV number 445-01-01]
Рис. Schneider ElectricПараллельные тексты EN-RU
A timing relay is a component which is designed to time events in industrial automation systems by closing or opening contacts before, during or after a set timing period.
[Schneider Electric]Реле времени - это устройства, предназначенные для применения в схемах промышленной автоматизации и в соответствии со своей функцией, реализующие заданные выдержки времени, и замыкающие или размыкающие контакты реле до, в процессе или после отсчета выдержки времени.
[Перевод Интент]
Недопустимые, нерекомендуемые
Тематики
Синонимы
EN
- automatic timer
- automatic timing device
- clock relay
- cycle timer
- delay relay
- delay switch
- preset interval timer
- specified-time relay
- time element
- time limit relay
- time relay
- time switch
- time-delay device
- time-delay relay
- time-delay switch
- timer
- timing device
- timing relay
- timing unit
DE
FR
Англо-русский словарь нормативно-технической терминологии > time-delay switch
118 disconnectable time-delay switch
разъемный выключатель с выдержкой времени
-
[IEV number 442-04-36]EN
disconnectable time-delay switch
disconnectable TDS
a time-delay switch including two parts, the first being used as a base and including the terminals, the other being removable and including the switching and the control circuits, the two parts being resiliently connected together using a means, which allows joining and/or separating with or without the use of a tool
[IEV number 442-04-36]FR
minuterie débrochable
interrupteur temporisé composé de deux parties, l'une servant de base et portant les bornes, l'autre amovible portant le circuit de l'interrupteur et le circuit de commande, les deux parties s'adaptant l'une dans l'autre par des connexions élastiques et pouvant être solidarisées ou séparées avec ou sans l'aide d'un outil
[IEV number 442-04-36]Тематики
- электротехника, основные понятия
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > disconnectable time-delay switch
119 resetting time-delay switch
выключатель с самовозвратом выдержки времени
-
[IEV number 442-04-35]EN
resetting time-delay switch
resetting TDS
a time-delay switch which reverts to the full time delay when the operating means is actuated during a previously stated time delay
[IEV number 442-04-35]FR
minuterie à recyclage
interrupteur temporisé qui revient au début d'une temporisation complète quand son circuit de commande est sollicité au cours d'un précédent cycle de temporisation
[IEV number 442-04-35]Тематики
- выключатель, переключатель
EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > resetting time-delay switch
120 single-shot trigger circuit
моностабильный элемент
одновибратор
-
[ГОСТ 2.743-91]Одновибраторы -"ждущие мультивибраторы" представляют собой микросхемы, которые в ответ на входной сигнал (логический уровень или фронт) формируют выходной импульс заданной длительности.
Длительность определяется внешними времязадающими резисторами и конденсаторами.
То есть можно считать, что у одновибраторов есть внутренняя память, но эта память хранит информацию о входном сигнале строго заданное время, а потом информация исчезает.
В стандартные серии микросхем входят одновибраторы двух основных типов:
- одновибраторы без перезапуска;
- одновибраторы с перезапуском
Одновибратор без перезапуска не реагирует на входной сигнал до окончания своего выходного импульса.
Одновибратор с перезапуском начинает отсчет нового времени выдержки Т с каждым новым входным сигналом независимо от того, закончилось ли предыдущее время выдержки.
В случае, когда период следования входных сигналов меньше времени выдержки Т, выходной импульс одновибратора сперезапуском не прерывается.
Если период следования входных запускающих импульсов больше времени выдержки одновибратора Т, то оба типа одновибраторов работают одинаково.
Одновибратор без перезапуска
Одновибратор с перезапуском
[Ю.В. Новиков. Введение в цифровую схемотехнику]
Параллельные тексты EN-RU
Monostable flip-flop
The output variable will be 1 only if the input variable changes to 1.
The output variable will remain 1 for 100 ms, regardless of the duration of the input value 1 (non-retriggerable).
Without a 1 in the function block, the monostable flip-flop is retriggerable.
The time is 100 ms in this example, but it may be changed to any other duration.
[Schneider Electric]Одновибратор
Значение переменной на выходе равно 1, если входная переменная становится равной 1.
Выходная переменная сохраняет значение 1 в течение 100 мс независимо от времени, в течение которого входная переменная продолжает оставаться равной 1 (без выполнения повторного запуска элемента).
Если в обозначении функции элемента не стоит "1", то это одновибратор с перезапуском.
В данном примере время выходного импульса составляет 100 мс, но его можно изменить на любое другое.
[Перевод Интент]Тематики
- Булева алгебра, элементы цифровой техники
Синонимы
EN
- biased multivibrator
- delay multivibrator
- gate multivibrator
- gated multivibrator
- kipp oscillator
- kipp relay
- latching circuit
- mono
- monoflop
- monostable
- monostable circuit
- monostable flip-flop
- monostable multivibrator
- monostable trigger circuit
- monovibrator
- one-cycle multivibrator
- one-shot
- one-shot generator
- one-shot multivibrator
- single flip-flop oscillator
- single vibrator
- single-shot flip-flop
- single-shot multivibrator
- single-shot trigger
- single-shot trigger circuit
- single-trip multivibrator
- single-trip trigger
- single-trip trigger circuit
- start-stop multivibrator
- trigger circuit
- univibrator
триггерная схема одноразового действия
одновибратор
ждущий мультивибратор
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
Синонимы
EN
Англо-русский словарь нормативно-технической терминологии > single-shot trigger circuit
СтраницыСм. также в других словарях:
delay circuit — vėlinimo grandinė statusas T sritis automatika atitikmenys: angl. delay circuit; time delay circuit vok. Verzögerungskreis, m; Verzögerungsschaltung, f rus. цепь задержки, f pranc. circuit à retard, m; circuit de retard, m … Automatikos terminų žodynas
delay circuit — vėlinimo schema statusas T sritis automatika atitikmenys: angl. delay circuit; time delay circuit vok. Verzögerungsschaltung, f rus. схема задержки, f pranc. circuit de retard, m … Automatikos terminų žodynas
delay circuit — vėlinimo grandinė statusas T sritis fizika atitikmenys: angl. delay circuit; time delay circuit vok. Verzögerungskreis, m; Verzögerungsschaltung, f rus. цепь задержки, f pranc. circuit de retard, m … Fizikos terminų žodynas
time-delay circuit — vėlinimo grandinė statusas T sritis automatika atitikmenys: angl. delay circuit; time delay circuit vok. Verzögerungskreis, m; Verzögerungsschaltung, f rus. цепь задержки, f pranc. circuit à retard, m; circuit de retard, m … Automatikos terminų žodynas
time-delay circuit — vėlinimo schema statusas T sritis automatika atitikmenys: angl. delay circuit; time delay circuit vok. Verzögerungsschaltung, f rus. схема задержки, f pranc. circuit de retard, m … Automatikos terminų žodynas
time-delay circuit — vėlinimo grandinė statusas T sritis fizika atitikmenys: angl. delay circuit; time delay circuit vok. Verzögerungskreis, m; Verzögerungsschaltung, f rus. цепь задержки, f pranc. circuit de retard, m … Fizikos terminų žodynas
pulse delay circuit — impulsų vėlinimo grandinė statusas T sritis automatika atitikmenys: angl. pulse delay circuit; pulse retardation circuit vok. Impulsverzögerungsschaltung, f rus. схема задержки импульсов, f pranc. retardateur d impulsions, m … Automatikos terminų žodynas
circuit de retard — vėlinimo grandinė statusas T sritis automatika atitikmenys: angl. delay circuit; time delay circuit vok. Verzögerungskreis, m; Verzögerungsschaltung, f rus. цепь задержки, f pranc. circuit à retard, m; circuit de retard, m … Automatikos terminų žodynas
circuit à retard — vėlinimo grandinė statusas T sritis automatika atitikmenys: angl. delay circuit; time delay circuit vok. Verzögerungskreis, m; Verzögerungsschaltung, f rus. цепь задержки, f pranc. circuit à retard, m; circuit de retard, m … Automatikos terminų žodynas
circuit de retard — vėlinimo schema statusas T sritis automatika atitikmenys: angl. delay circuit; time delay circuit vok. Verzögerungsschaltung, f rus. схема задержки, f pranc. circuit de retard, m … Automatikos terminų žodynas
circuit de retard — vėlinimo grandinė statusas T sritis fizika atitikmenys: angl. delay circuit; time delay circuit vok. Verzögerungskreis, m; Verzögerungsschaltung, f rus. цепь задержки, f pranc. circuit de retard, m … Fizikos terminų žodynas